Loading...
HomeMy WebLinkAboutNotice of Acceptance (2) i MIAMI-Ol�El r -MIANII=DADS COUNTY PRODUCT CONTROL SECiION 11805 SW 26 Street.Room 208 DEPARTMENT OP REGULATORY AND LCON01-11C RESOURCES(RFR) Miami,Plorida 33175-2474 13OARD AND CODE ADA4INISTRATION DIVISION T(786)3 1 5-2590 17(786)31525-99 NOTICE OF ACCEPTANCE (NOA) �s«�y.in�a«ia li�C.f?OyICI'OI101➢1Y' CertainTeed Corporation 18 Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade Cotanty RER-Product-Confrol Section to be used in Miami Dade County and other areas where allowed by the Authority Having.lurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below.The Mianii-Dade County Product Control Section (In Miarni Dade County)and/or the AHJ(in areas other ti�an:Miami Dade County)reserve the right to have this product of material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves die right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements.of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including.the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Nlianii-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMMATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT:The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy'of this entire NOA shall be provided to the user-by the manufacturer.or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 414-0224.03 and consists of pages l through 42. The submitted documentation was reviewed by Alex TiQera. WIIAMI-DADECOUNTr j NOA No.: 14-0529.02 �FJJUXITSI Expiration Date: 06/19/1 Y Approval Date: 09/21/15 Page 1 of 42 ROOFING SYSTEM APPROVAL Catmorv: Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -127.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1. Test Product Product Dimensions Specification Description All Weather/Empire Base 39 3/s" x 65'10"; ASTM D 4601,Type Asphalt coated, fiberglass reinforced Sheet Roll weight: 70 lbs. 11 base sheet. (2 squares) UL Type G2 Flexiglas Base Sheet 39'/8" 98'9"; Roll ASTM D 46011 Type Modified Bitumen coated fiberglass weight: 90 lbs. II base sheet. (3 squares) UL Type G2 Flintlastic Base 20 39 3/8" x 49' 6";Roll ASTM D 6163. Iviodified Bitumen coated fiberglass weight: 90 lbs. Grade S,Type I base sheet. (1.5 squares) Plintglas Ply Sheet Type IV 393/s" 1647';Roll ASTM D 2178,Type Fiberglass,asphalt impregnated ply sheet. weight: 38 lbs. IV (5�squares) UL Type G 1 Flint;las Premium Ply Sheet 39 3/e N 164'7";Roll ASTM D 2178,Type Fiberglass, asphalt impregnated ply Type VI weight: 40 lbs. VI sheet. (5 squares) UL Type G I Flintlastic STA 39=/s"x 32' 10"; Roll ASTNI D 6222, Smooth surfaced APP Modified weight: 87 lbs. Grade S,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA 39 3/S" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven (I square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39'/s"x 32' 10"; Roll ASTM D 6222. Granule surfaced APP Modified weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS 39 3/8" x 32' 10";Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. NOA No.: 14-0529.02 MIAMI•DADE COUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 2 of 42 TRADE NAMES OF PRODUCTS MANUFACTURED.OR,LABELED BY A.PPLiCANT: TABLE:1 ' Test Product Product- Dimensions Stiecification Description Flintlastic Premium GMS 39'/s"x 32; 10"; Roll ASTM D 6164, " Granule surfaced SBS Modified weight: 101 lbs. Grade G, Type If Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. Flintlastic FR-P , 393/8" x 32' 10";Roll . ASTM D 6164, Fire resistant,granule surfaced SBS, weight: 101 lbs. Grade G,Type I Modified Bitumen Membrane with (1 square)' non-woven polyester mat reinforcement for mop application. Flintlastic Premium FR-P 39'/s" x 32' 10";Roll . ASTM D 6164, Fire resistant,granule surfaced SBS weight: 101 lbs. Grade G,Type Ii Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcement for mop applications. Flintlastic FR Dual Cap 39 3/8"x 32'-10"; Roll ASTM D 61.62. Granule surfaced SBS modified weight: 103 tbs. Grade G.Type I bitumen membrane %with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or inop applications. Flintlastic-FR Cap 30 39 3/8" x 32' 10";Roll ASTM D 6163, Fire resistant-, granule surfaced SBS weight: 86 Ibs: Grade G;Type I Modified Bitumen membrane with (I square) fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T 39-3/8"x 32' 10';Roll ASTM D 6163. Granule surfaced SBS Modified weight: 100 tbs. Grade G,Type.I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Flintlastic Base 20-T 3.9-3/8"x 33r'; Roll ASTM D 6163; Modified Bitumen, coated fiberglass Weight: 81 lbs. Grade S,Type i base sheet for torch application.- (I square) Flintlastic FR Cap 30 CoolStar 393/s"x 32' '10"; Rol ASTM D 6163, Fire resistant,granule surfaced SBS weight: 88 lbs. Grade G.Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered w6th reflective ' r Cool Star Coating. Flintlastic FR Cap 30 T 39 /s".x 32' 10"; Roll ASTM D 6163, Fire resistant,granule surfaced SBS CoolStar weight: 1021bs. Grade G,Type I Modified Bitumen membrane with Q"square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. MIAM4DADECOUIVTY NOA No.: 1445,29.02 :1 I Expiration Date: 06/19/13 Approval Date: 09/24/15 Page 3 of 42 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE Test Product Product Dimensions Specification Description Flintlastic GTA CoolStar 39'/s" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G,Type I Bitumen-membrane with non-woven (1 square) polyester mat reinforcement for torch application_ Covered with reflective CoolStar Coating. Flintlastic GTA-FR CoolStar 39'/s" x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GVIS CoolStar 39'/s" 32' 10"; Roll ASTM D 6164 Granule surfaced SBS Modified weight: 97 lbs. Grade G,Type I Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium GMS 39 3/s" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified CoolStar weiQht:103 lbs. Grade G, Type I1 Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating' Flintlastic FR-P CoolStar 393/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, Granule surfaced SBS weiaht: 103 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium FR-P -39 '/s" x 327 10"; Roll ASTM D 6164, Fire resistant,granule surfaced SBS CoolStar weight: 103 lbs. Grade G,Type it Modified Bitumen Membrane with (l square) non-woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Ultra Poly SMS 39'/s" x 32' 10'; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 90 lbs. (1 Grade S.Type i Bitumen Membrane with non-woven squares) polyester mat reinforcement for mop applications. Glasbase Base Sheet 36" x 98' 9"; Roll ASTM D 4601, Type Asphalt coated,fiberglass base sheet. weight: 75 lbs. it, (3 squares) UL Type G2 MIAMI•DADE COUNTY [VOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 4 of 42 TRADE DAMES OF]PRODUCTS MANUFACTURED OR LABELED By APPLICANT: TABi.,E I Test Product Product Dimensions Specification Description Flintlastic Poly SMS Base 39'/s" x 64'3";Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight: 90 lbs. Grade S, Type 71 base sheet. (2 squares) UL Type G2 Yosemite Venting Base Sheet 39'/s" x 32'10"; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 85 lbs. ASTM D 4897.Type buffer sheet. (] square) 11 UL Type G3 Flintlastic APP Base T 39'/s"x 65' 4", Roll ASTM D 6509 Modified Bitumen coated fiberglass weight: 100 lbs. base sheet. (2 squares) Flintlastic Ultra Glass SA 39 3/s"x 33'1 1";Roll ASTM D 1970 Self-adhering,fiberglass reinforced, «-eight: 73 lbs. SBS modified bitumen base/ply sheet. (1 square) Black DiannondT`! Base Sheet 36" x 68'7': Roll ASTM D 1970 Self-adhering fiberglass reinforced iveipht: 78 lbs. modified bitumen base sheet (2 squares) APPROVED INSULATIONS: T,'LBLE 2 Product Name Product Description Manufacturer (With Current NOA) FlintBoard ISO Polyisocyanu rate foam insulation CertainTeed Corporation FlintBoardH iSO Polyisocyanurate foam insulation CertainTeed Corp. ACFoam-11 Polyisocyanurate foam insulation Atlas Rooting Corp. High Density Wood Fiberboard Wood fiber insulation board Generic Perlite Insulation Perlite insulation board Generic DensDeck, DensDeck Prime Water resistant gypsum board' Georgia Pacific Gypsum LLC i-I-•Shield Polyisocyanurate foam insulation Hunter Panels LLC ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp. ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate roam insulation RMax Operating,LLC SECUROCK Gypsum-Fiber Roof Board homogenous fiber reinforced USG Cop. MlAMI•DADE COUNTY NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 5 of 42 APPROVED FASTENERS: TASLE3 Fastener Pi-oduct Product Manufacturer Number Name Description Dimensions (With Currcnt NOA) I. Trufast#12 DP Fastener Insulation fastener for wood various Altenlob, Brinch &Co. U.S., and steel decks Tnc. 2. Trufast 3"Metal Galvalume steel plate 3" round Altenloh,Brinch &Co.U.S., Insulation Plate Inc. 3. FlintFast#12 Coated, carbon steel screw various CertainTeed Corp. 4. FlintFast 3"Tnsulation Galvalume AZ50 steel plate 3" round CertainTeed Corp. Plate 5. FlintFast#14 lnsulation fastener for wood various CertainTeed Corp. and steel decks 6. Simplex MAXX Cap Polymer Fastner 1" long Simplex Nails, Inc. 7. OMG 412 Standard Insulation fastener for wood various ONIG_, Inc. Roofgrip and steel. S. OMG 3"Galvanized Steel Galvalume stress plate 3" round OMG, Inc. Plates 9. Trufast 414 HD Fastener Insulation fastener for wood various Altenloh.Brinch &Co.U.S., and steel decks Inc. 10. OMG Heavy Duty Tnsulation and membrane Various ONIG. Inc. fastener H. OMG 3 in. Round Metal Galvalume AZ50 steel plate 3" round OMG, Inc. Plates 12. AccutTrac Hestra Carbon steel fastener Various OMG,Inc. 13. AccuTrac Plates Galvalume stress plate. 3"square OMG, inc. 14. AccuTrac Flat Bottom A2-SS aluminized steel plate 3"square OMG, Inc. Plates . MIAMI•DADE COUNTY NOA No.: 14-0529.02 "'O Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 6 or42 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing,must be listed within a current NOA. System Number Manufacturer Application l. Generic Gravel applied at 400 ibs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnali Corp. Karnali(497 AF) Fibrated Aluminum Roof Coatin'o applied at an application rate of 1.5 gal/sq. 4. CertainTeed Corp. FlintCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC 4212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal./sq. MIAMI•DADE COUNTY NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 7 of 42 EVIDENCE SUBMITTED: Test Menev/Identifier Name Report Date Factory Mutual Research Corp. FM 4470 3Y8A l.AM 03/23/96 FM 4470 OD3A3.AM 04/04/97 FM 4470 2DOAO.AM 12/23/98 FM 4470 1 D7A4.AM l 1/09/98 FM 4470 3039046 06/15/10 FM 4470 3048520 09/19/13 Underwriters Laboratories..Inc. UL 790 R1 1656 01/11/13 United States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 N/lomentum Technologies,Inc. ASTM D 4601 AX31 G8D 09/05/08 ASTM D6164 AX3 I G8F 06/05/09 ASTM D6722 AX31G8G 06/05/09 ASTM D 3909/D 4897 AX3 I G8C 09/05/08 TrinityJERD TAS I14(J) 3504.06.01-1 06/05/01 TAS 114(J) 3507.08.99-1 04/18/01 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R 1 06/27/07 TAS 114(H) Letter 04/05/06 TAS 114 3533.01.06 01/06/06 TAS 114 3521.07.04 07/29/04 TAS 117(B)/ASTM D 6862 C8500SC.1 1.07 11/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C I 0080.09.08-R4 03/25/10 ASTM D6164/D4798 C31410.01.1 1-2 01/10/1 1 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D 1970 C40050.09.12-2 09/28/12 ASTM D5147/D4798 C31410.10.10-R 1 11/01/12 ASTM D5147/D4798 C31410.01.1 1-1-RI 11/01/12 ASTM D1876 C35460.05.1 1 06/16/1 1 ASTM D 1876, TAS 1 14(14), C421 10.08.12 08/13/12 TAS 117 (B) FM 4474/TAS 114 C39670.08.12 08/20/12 TAS 1 17B C35500.02.1 1 02/09/11 ASTM D4798 C31410.01.1 1-2A-R 1 02/21/13 ASTIVI D4798 C31410.12.13 12/05/13 ASTM D6222 C40050.12.13-R 1 12/31/13 TAS 117, TAS 114 C30310.12.09-RI 03/07/14 ASTM D1876, TAS 114 (14), C45620.03.14 03/27/14 FM 4474 ASTNI D 1876. TAS 114 (H), C47320.03.14-R 1 04101/15 FM 4474 PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08 Technologies LLC ASTNI D6163 CTC-066-02-01 08/09/11 ASTM D6222 CTC-070-02-01 08/09/11 MIAMI•DADE COUNTY NOA No.: 14-0529.02 "' Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 8 of 42 EVIDENCE SUBMITTED: Test A6ency/ldentifier Name Report Date AS,rM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02-01 03/13/12 ASTM D2.178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTNI D6164 CTC-132-02-01 06/1 1/12 ASTM D6164 CTC-162-02-01 05/09/13 AST1\,i D6164 CTC-161-02-01 05/09/13 ASTM D6162 CTC-183-02-01 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D1970 CTC-199-02-01 01/22/14 NOA No.: 14-0529.02 MIAMI•DADE COUNTY Expiration Date: 06/19/18 • • Approval Date: 09/24/15 Page 9 of 42 Membrane Type: APP Modified Deck Type 11: Wood,Non-Insulated Deck Description: I9/32" or greater plywood or wood plank System Type E(3): Base sheet mechanically fastened. All General and Svstein Limitations apply:. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Glasbase Base Sheet or Flintglas Premium Ply Sheet Type V1 mechanically attached as detailed below. ]Fastening: Base sheet shall be lapped 4" and fastened with 1 I ea. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rotes staggered in the center of the sheet 8"o.c. Plv Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet; Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20. Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of"20-40 Ibs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar,Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar torch adhered to base/ply sheet. Surfacing: Any of the approved surfacing? coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation 47) Pressure: MIAMI•DADECOUNTY NOA No.: 14-0529.02 ' Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 23 of 42 WOOD DECK SYSTEM LIMITATIONS: I. A slip sheet is required with Ply 4 and.My 6 when used as a mechanically fastened base.or anchor sheet. GENERAL LIMITATIONS: i. Fire classification is'not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at rate of20-40 1bs./s'q., cr mechanically attached using the fastening pattern of the top layer ;. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' nlaximunl. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the, base sheef is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping,-Nvith approved asphalt, IT' diameter circles;24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation: Encircling of the strips is not:acceptable: A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asollalt application of either system shall be at a_minimwn rate of 12 lbs./sq. Note: Spot attached systems shall belinii.fed to a inaaimuni design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 Ibf,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested, are below -275 Ibf. insulation attachment shall not be acceptable.. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value iii conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing, l prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect, or-Registered Roof Consultant play be submitted. Said revised fastener'spacing shall utilize the withdrawal resistance value taken from Testing Application-Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced.uplift pressure requirements of these areas. Fastener densities shall be increased for both, insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional E-ngineer,,Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation 99 will not be applicable:) 8. All attachment and sizing of periineter nailers, metal profile,and/or flashing termination designs shall conform to Roofing Application StandardRAS 1 1 1 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.field, perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at j enhanced pressure zones (i.e.perimeters,extended corners and corners). (When this limitation is.'specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance Nvith the Florida Building Code and Rule 61 G20-3 of theFlorida-Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-0529.02 MIAM1•DADE COUNTY � � Expiration Date: 06/19/13 Approval Date: 09/24/15 Page 42 of 42