Loading...
HomeMy WebLinkAboutBuilding PlansDocuSign Envelope ID: 7GBE502B-A3C2.45AF-95EO-312B9FOC8235 SLOPE: 5/12 THE METAL OVER 30# FELT OVER 5/8" COX PLY OVER PE TRUSSES @ 24" OC METAL DRIP OVER 1x2 WOOD DRIP OVER 2x6 FASCIA, ATTACH FASCIA TO RAFTER W/ (2)1613, 3.5" HEEL EXTG GRADE EXTG ASPHALT SHINGLE ROOF VALLEY TRUSS TO EXTG W S. VTCR TO EA EXTG EXTG TRUSS TO WALL W/ S. HETA16. SISTER NEW RAFTER TO TRUSS W/ (6)12D. --� TRUSS TO NEW BEAM W/ S. HETA20 CLG: 518" EXTERIOR GWB, �. CERTAINTEED EXT SOFFIT OR SIM BEAM: CASTCRETE BF16 1B/2T CUT BACK EXTG ROOF TRUSS EAVE TAIL FLUSH W/ EXT FACE OF EXTG WALL TRUSS TO EXTG BOND BEAM W/ S. HSTM16 TYP COLUMN: 8x16 CMU W/ #5 VERT EA CELL PE TRU @ 24" OC R EXTG TRUSS TO WALL W/ S. HETA16. EXTG 8" CMU WALL i EXTG 4" SLAB ON GRADE, CUT SQUARE FOR NEW FOOTING 6 `n EXTG SLAB �- 011 i . 36"W x 36"W x 36"D ISOLATED FOOTING @ EA ' COLUMN W/ (3) #6 REBAR EW BOTT. - T:i'Y_� SECTION SCALE: 1/2"= T-O" CAST-CRETE LINTEL DIAGRAM I-- -F = FILLED WITH GROUT I U = UNFILLED — QUANTITY OF #6 FIELD ADDED REBAR AT BOTTOM OF U-LINTEL CAVITY FOR GRAVITY LOAD 8F16-1 B/1T 1 I , NOMINAL WIDTH — QUANTITY OF #5 FIELD ADDED REBAR AT TOP OF NOMINAL HEIGHT COMPOSITE U-LINTEL FOR UPLIFT LOAD #6 FIELD ADDED REBAR AT TOP OF COMPOSITE U - LINTEL MIN. (1) REQ'D 1-1l2' CLEAR i - FIELD PLACED C.M.U. x a � _z m m GROUT z — #6 FIELD ADDED REBAR AT • BOTTOM OF U-LINTEL CAVITY IT -SIB" ACTUALI BOTTOM REINFORCING Y-dPROVIDED IN U-LINTEL S" NOMINAL WIDTH (SEE REINFORCING SCHEDULE) A-1 13'3W _ — ------- 12-9 ---- 12,-9�—=--'---11��_------------'---- — — — — — — — — — -- — — — — — I — — — — — — — — — — — — >. \ ' I NEW COVERED PORCH / TYP TIE IN: END OF BEAM TO EXTG BOND BEAM W/ (1) #5 T/B. END OF / FOOTING TO EXTG FOOTING W/12) #5. EPDXY EMBED STEEL 5" / I \ I \ EXTG RESIDENCE \ \ \ / I \ \ I / \ I / I I \ -------- I I I ---------------� I ' ---- PROPOSED FLOOR PLAN SCALE: 1/4"= V-0" SHEETINDEX PROJECT DESCRIPTION New rear porch addition to an existing 1 story SF residence ZONING INFORMATION: parcel id:1301-605-0374-000-6 RS-4 (St Lucie County) flood zone: X UTILITY INFORMATION: gas: n/a sewage: septic potable water: well AREA CALCULATIONS: extg total bldg area 2,240 sf demolished front porch 16 sf added covered front porch 181 sf added covered rear porch 312 sf new total bldg area 2,717 sf EXTG CONC PATIO / / / / / / / i / EXTG RESIDENCE / / i / / / - ----- -------�LE-cop \\ fi�vitwtlu _ k OODE COMPLIANCE �fTlyl \ \ \ 'EXTG FRONT 130C V \ \ PORCH , I \ \ I I \\ \\ 1-------- / I I I / \ \ / I I I I I I i I I I I I I I I I I I I \ I I \I EXTG FLOOR/DEMO PLAN SCALE: 1/4"= T-O" r E ti o 0 G1 ` Q E = U V M d C (� C ON "t O'C a co S+'A a COD tm @)� Iv . - w04 Q) V tm O M I` to 2+N'�Y0 O V co m LL U. U af U U w O C a U LL w a N u, x F 0 0 W 0 J ❑ Z❑ Q ❑ W J W Qw W U r Lo 3 m IL cow m J 9 LL m Z Z O U W ❑ _ L I- a 0 r) ® V W O W w LL U � ` w r w O N Z CL m o a /(U W U o Z N z w co W 0 m < 3 a z (D w ❑ 9 a 0 z w O W 0 0 floor plan 9/24/20 SHEET A-1 E Docu&gned by: Y'A4t.�c E935FAF3OE92486... 9/24/2020 co OIS P. LIFe� F . AR97108 / . �� E5D2B-A3C2-45AF-95EO-312B9FOG5235 92.01Y (W90"00-01I \ // 1 � I v NEW COVERED PORCH A / I i I \ /EXTG RESIDENCE \ I \ � 1 K/ �� I I� I I EXTG CONC DRIVEWAY 00-0I ARCHITECTURAL SITE PLAN SCALE: 3/32"= 1'-0" CD O O O (n O O N O '.0 FOUNDATION PLAN SCALE: 3/16"= 1'-0" PRODUCT r GLASS,, a". urns TYPE ID, B ILQINGDpz PpQDUCTDP TyP�s` MFI <, � MQDEL APPROVAL#I•, � FA�7NERSe ,.. .., 1 '�® OB Y f 1 • ,0 1. ID as per door &window schedule, or all meaning worst case of all similar items of that type. - 2. If building dp are left blank- see door & window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted for verification by contractor,. they are assumed. S. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7, 1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. IiEvltweu FUh CODE COMPLIANCE ST. LUCIE COUNTY BOC.0 t0 E ti O V d O U 3 E .� 0 N Nye— !Z C w O�O'� fn 0 C dMol) E �a ao + M (0 m C c N N L m C`�N Z.� co N Y Q O C M C J J O m (LO LL LL V U �- U r U W 0 a U lL U w a ul F 0 O LL W W a O J W 0 z Q W J W aO W U /� L J W W (M a a VM�y� U \'J a J Z Z LL 0 z m 6 ® U W o _ f L ® O Q W o O o! a w T W K 1 U w ry elf w w O L 01 � a 1rr ❑ Z N Z w 2 cocooM o Q z Z Z z g a vi z O rn 0 �J Q F- Z W O U Ud 0 0 site plan 9/24/20 SHEET A Eoocusiened by: �" ut�� E935FAF3OE92486_. 9/24/2020 OF FOR Nets P. L AR97108 �F C� `.444G FRED ARG DocuSign Envelope ID: 7GBE5D28-A3C245AF-95EO-312B9FOC8235 1 BASIS OF STRUCTURAL DESIGN: SOIL BEARING: 2500 psf (assumed) WIND: 157mph (ult), risk cat 2, exp B, wind borne debri region, .18 enclosed design FROST DEPTH: 12" - THE STRUCTURAL DESIGN APPROACH FOR MASONRY, ROLLED STEEL, AND LIGHT WEIGHT STEEL IS WORKING STRESS DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE IS ULTIMATE STRENGTH DESIGN. THE DESIGN SERVICE LOADS ARE AS FOLLOWS: ROOF LIVE LOAD 20 PSF(slope<4:12) ROOF DEAD LOAD 7 PSF TC ROOF WIND LOAD DRAWINGS) SEE ( G ) CEILING DEAD LOAD 5 PSF BC WALL WIND LOADS (SEE DRAWINGS) FLOOR DEAD LOADS 15 PSF TC, 5 PSF BC FLOOR LIVE LOADS SEE BELOW 711.161:a4►•I:111toy-A Uninhabitable attics without storage 10 psf Uninhabitable attics with limited storage 20 psf Habitable attics and attics served with fixed stairs 30 psf Balconies (exterior) and decks 40 psf Fire escapes 40 psf Guardrails and handrails 200 lb Guardrail in -fill components 50 plf Passenger vehicle garages 50 psf Rooms other than sleeping room 40 psf Sleeping rooms 30 psf Stairs 40 psf WIND PRESSURES asd FCOMPONENT AND CLADDING LOADS... FROM TABLE FBC R301.2(2) ZONE EFFECTIVE WIND AREA (SF) PSF 157 mph 1 10.0 10.8 -26.1 1 20.0 10.2 -25.1 1 50.0 9.6 -24.8 1 100.0 9.3 -24.1 Roof > 0 to 7 degrees 2 10.0 10.8 -44.2 2 20.0 10.2 -39.5 2 50.0 9.6 -32.8 2 100.0 1 9.3 -28.8 3 10.0 10.8 -66.6 3 20.0 10.2 -54.9 3 50.0 9.6 -39.5 3 100.0 9.3 -28.8 1 10.0 15.3 -24.1 Roof > 7 1 20.0 14.0 -23.1 1 50.0 12.2 -22.1 1 100.0 10.8 -21.4 2 10.0 15.3 -42.2 to 27 degrees 2 20.0 14.0 -38.5 2 50.0 12.2 -33.8 2 100.0 10.8 -30.8 3 10.0 1 15.3 -62.6 3 20.0 14.0 -57.9 3 50.0 12.2 -52.9 3 100.0 10.8 -48.9 4 10.0 26.7 -28.8 4 20.0 25.4 -27.1 4 50.0 23.8 -25.8 4 100.0 22.6 -24.1 4 500.0 19.9 -21.4 Wall 5 10.0 26.7 -35.5 5 20.0 25.4 -32.8 5 50.0 23.8 -29.8 5 100.0 22.6 -27.1 5 500.0 19.9 21.4 1 adjustment factor used WALk6 �-Pf- ( I . , 0 5 10° GABLE ROOFS 0S10' I $ ;mI a#oo n t r I , ( 101-0545' ... AAGABLE ROOFS 10'<:0 5 45' Note:. a=4feet n:aIIcwms.. 7` �ml i 10 <0530" #411 HIP ROOFS 10' < D s: 30' GENERAL NOTES- residential 1. CODE COMPLIANCE: 1.1. This project was designed under the following p 1 g e g codes. The construction documents cannot reference all of the codes require for the construction of this building. B submitting these g y g construction documents for permit or commencing work, the contractor, hereby agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing codes includingbut not limit t t limited o, he most current editions as adopted by the stale of Florida, of the following: 2017 FBC: RESIDENTIAL, 6th ad - 2017 FBC: ENERGY CONSERVATION, 6th ad 2014 NATIONAL ELECTRIC CODE 2. ALL GENERAL NOTES 2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF CONFLICT, NOTIFY ARCHITECT. THESE DRAWINGS, INI CONJUNCTION WITH OTHER SUBMITTALS, REPORTS, OR WRITTEN INSTRUCTIONS BYARCHITECT OR CONSULTANTS,SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION DOCUMENTS. 2.2. THE FOLLOWING GENERAL &SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS, SUBCONTRACTORS, AND SUPPLIERS ENGAGED IN EXECUTION OF WORK 6N THESE PLANS. _. 2.3. GENERAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF DRAWINGS AND ADDENDUM'S TO ALL SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIES AND/OR H N /OR CONFLICTS IN THE DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY. 2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS ,WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECTAND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. 3. ARCHITECT & CONTRACTOR RELATIONSHIP 3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE ACCEPTING LIABILITY THAT MAYARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR'S INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REF EREN91E SOMETHING THAT IS REQUIRED BY THE CODES MENTIONED, THE CONTRACTOR AND SUBS ARE REQU RED TO: UNDERSTAND AND ADHERE THE BLDG CODES NO DIFFERENT THAN THE ARCHITECT. 4. WORKMANSHIP: 4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. 5. COORDINATION: 5.1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES. 5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FARAS IT AFFECTS THE TRADES. ALL TRADES SHALL INCLUDE EVERYTHING NECESSARY FORA COMPLETE AND PROPERLY FUNCTIONING CODE -ACCEPTABLE PROJECT, UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). 6. ABBREVIATIONS: 6.1. SEE ABBREVIATION LIST FOR DEFINITIONS WHICH ARE', USED IN THESE DRAWINGS AND SPECIFICATIONS. 7. CONDITIONS NOT DETAILED: 7.1. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL' ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE A DETAILED SPECIFICATION FOR A CERTAIN PRODUCT, CONTRACTOR MAY REQUEST A SUBSTITUTION APPROVAL BY ARCHITECT. IF DRAWINGS HAVEA GENERIC SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL BYARCHITECT. 8. VERIFY SITE INFORMATION: 8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. 9. PRIOR TO ANY EXCAVATION WORK: 9.1. THE CONTRACTOR I REQ UIRED QU IRED TO LOCATE ANY AND ALL UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, UTILITIES AND OWNER. CONTACT ALL AFFECTED UTILITY COMPANIES AND INFORM THEM OF THE IMPENDING CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES. 10. DIMENSIONS: 10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAYBE "ROUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED DIMENSIONS. NOTES TAKE PRECEDENCE OVER GRAPHICS. CONTRACTOR TO VERIFYALL EXISTING CONDITIONS FOR WORK TO EXISITING BUILDINGS. 11. HEIGHT ELEVATIONS: 11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION 0'-0" (BUILDING ELEVATIONS MAY BE NOTED AS "BLDG EL. -"OR "EL. _" OR "AFF. _") ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE ELEVATION IS ON ANY PLANS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION SITE ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A REFERENCE DATUM. SITE ELEVATIONS MAY BE NOTED',AS: "SEL " OR "_ NAVD" OR "+X.X"'. CONSULTARCHITECT FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING_ 12. AMBIGUITY: 12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT SHALL INTERPRET THE CONSTRUCTION DOCUMENTS, 12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS,. CONSULT WITH ARCHITECT. 13.. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS: 13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE (NOA)/ PRODUCT APPROVALS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLEAT TIME OF INSPECTION. EVEN IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO DIFFERENT PRODUCT THAT MEETS THE SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE IS A DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATIONAND ARCHITECT'S SPECS, VERIFY W/ ARCHITECT. 13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR; DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS ATJOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSES/TECHNIQUES OF CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION .DOCUMENTS. 14. GENERAL STRUCTURAL 14.1. ONCE SIGNED & SEALED BYARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED. 14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION. PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL - ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO RESIST S ST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION PHASE LOADS. 14.3. THE CONTRACTOR IS TO VERIFYALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATIONAND START OF CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. 14.4. SPECIFIC PRODUCT DATAMUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE ROOFS OR STONE ON RAISED FLOORS. 15. CAST -IN -PLACE CONCRETE 46.1. ARGI 'ITEGT- OR ENGINEER OF REGORD TO BE NOTIFIED IN WRITING PRIOR TO POUR, TO GIVE ARGI 'ITEGT-:Fl E OPTION TO lNSPEGT TF= c N F E , . FOR. OVERHEAD BEAMST SLABS 15.2. CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PICA MANUAL LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN STRENGTH. OVERHEAD SLAB_ AND BEAMS Tn BE 4009 PSI GONGRET-In MIN UNG , G06UMN AMID WALL GONGRETE TO BE 3000 PSI GONGRETE MIN UNO -FOOTINGS AND SLAB -ON -GRADE TO BE 3000 PSI CONCRETE MIN UNO -AUGERGAST PILE TO BE 5000 PSI CONCRETE MIN UNO 15.3. CONCRETE, WHEN PLACED, SHALL HAVE SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS ON -GRADE WHICH SHALL HAVE MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH. 15.4. COMPLY WITH ALL REQUIREMENTS OF ACI 117-10, ACI 318-14, ACI-315 15.5. ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTMA-185. ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE ACI DETAILING MANUAL AND THE CONCRETE REINFORCING STEEL INSTITUTE. DON'T SPLICE IN MIDDLE 113 OF BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMENT LENGTH/LAP DISTANCE IF NOT NOTED VERIFY W/ ARCHITECT 15.6. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE. 15.7. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301 PROCEDURES. PERFORM CURING OF THE CONCRETELY CURING AND SEALING COMPOUND, BY MOIST CURING, BY MOISTURE RETAINING COVER CURING OR BY COMBIN TION THEREOF. 15.8. SEE THE DRAWINGS FOR CONCRETE COVER FOR REINFORCING STEEL, BUT IN NO CASE SHALL THE COVER BE LESS THAN THAT REQUIRED BY ACI318: -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3" -CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2" 15.9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY KEYED, DOWELED OR SAW -CUT CONTROL JOINTS SUCH THAT THE ENCLOSED AREA DOES NOT EXCEED 260 SQUARE FEET. POST -TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON -EXTRUDED PREMOLDED MATERIAL OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751) 15.10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS, ETC.) NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIOR APPROVAL OF THE ARCHITECT, CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING. PROPOSED JOINTS TO ENGINEER FOR APPROVAL, 15.11. ALL CONCRETE SHALL UTILIZE A MINIMUM OF 20% FLYASH CONTENT. 15.12. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL REINFORCING BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS. FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PERACI 318 OR FQO UNO. -TIES/STIRRUPS TO STARTATA DISTANCE FROM SUPPORT OF 1/2 TIE SPACING 15.13. NO HOLES, CHASES, OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT ARCHITECT'S APPROVAL. 16. CONCRETE MASONRY: 16.1. CMU DESIGNED AND TO BE IN ACCORDANCE ACI 530-13/ASCE 5-13/TMS 402-13, "BUILDING CODE REQ FOR MASONRY STRUCTURES", "COMMENTARY ON BUILDING REQ FOR MASONRY STRUCTURES' 16.2. MASONRY STRENGTH (Pm DESIGN) UNO: -BLOCK STRENGTH = 1900, ASTM C90 -MORTAR STRENGTH = 1800, TYPE S -GROUT STRENGTH = 2000 16.3. GROUT SHALL HAVE A SLUMP OF 8 TO 11 INCHES, BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN A COMPRESSIVE STRENGTH OF 3000 PSI. GROUT SHALL CONFORM TO REQUIREMENTS OF FLBC STANDARDS. USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT DOWN 1-1/2" BELOW TOP OF BLOCK AT GROUT LIFT JOINTS AND AT CONCRETE PLACED OVER MASONRY. 16.4. CONCRETE MASONRY UNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED AND BUILT TO THE THICKNESS AND IN A RUNNING BOND AS INDICATED AND CONFORMING TO THE TOLERANCES SPECIFIED IN ACI 531.1 AND 530.1. 16.5. REINFORCING BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS UNLESS NOTED OTHERWISE AND D TIED OR OTHERWISE SECURELY SUPPORTED AT THE TOP AND BOTTOM TO ENSURE THAT THE BAR DOES NOT MOVE DURING GROUTING. 16.6. MORTAR DROPPINGS AND OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. 16.7. GONTROL AIGINTS SHALL BE PROVIDED IN AGGORDIAINGE WIT! 1 Tl E 619GAkTIONS AND DETAILS SHOWN ON THE DRAWINGS. GONTon n N Tc ON BOTH SIDES OF 16.8. WALL REINFORCEMENT: VERTICALAND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SPECIFIED ON THE DRAWINGS. DESPITE IF SHOWN ON DRAWINGS- PLACE VERTICAL REINFORCING BARS AT CORNERS,. EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WITHIN IT OF JAMBS FOR OPENINGS WIDER THAN 12', BELOW BEAM BEARING, BELOW GIRDER TRUSS BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. IF NOT SPECIFIED IN TEXT ON DRAWINGS USE #5 @ 48" OC. WALL/COLUMN REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. 8" TOLERANCE ALLOWED FOR WALL REINF PACING. SEE DOWEL NOTE 17.2 BELOW. 16.9. REINFORCED. MAE ONRY LINTELS SUCH AS CAST CRETE TO BE INSTALLEDAS PER MFR INSTRUCTIONS. USE #6 BOTTOM FIELD BAR IN LIEU OF #5 FOR ALL OPENINGS WIDER THAN 12'. LINTELS TO HAVE 4" MINIMUM BEARING. CONTIt IUOUS REIN ACROSS COLUMNS. IF SPECIFIED, CA LINTEL LENGTH IS +/- AS LONG AS MIN BRG IS MET. )OOR/WINDOW LINTELS CAN BE DEEPER(TALLER) THAN SPECIFIED BUT NOT SHORTER. 16.11. BOND/TIE BEAMS/kINTELS- CONTINUE REINFORCING BARS CONT (UNINTERRUPTED) AROUND ALL CORNERS, OVER OPENINGS, ACROSS WALL INTERSECTIONS, THROUGH TIE COLUMNS, AND UP/DOWN AT CHANGES IN BOND BEAM ELEVATION. 17. FOUNDATIONS: 17.1. BUILDING AREA TO BE STRIPPED/GRUBBED OF SURFACE DEBRISIVEGITATION. FILL TO BE CLEAN GRANULAR & UNIFORMLY COMPACTED TO 95% DENSITY (ASTM D 1557) AND MEASURED IN 12" LIFTS. AT DISCRETION OF CONTRACTOR OR BLDG INSPECTOR, ARCHITECT RECOMENDS SOIL TO BE TESTED BY GEOTECH ENGINEER TO ENSURE MINIMUM SOIL BEARING PRESSURE CAPACITY & RECOMEND SITE PREP. 17.2. DOWEL VERTICAL. REINFORCING BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF THE SAME SIZE AND SPACING OF WALL ABOVE. THERE SHALL BE A DOWEL FOR EACH VERTICAL REINFORCING BAI Z. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. For#5: MINIMUM 3)" LAP W/ 10" HOOK UNO. SEE WALL REINFORCEMENT NOTE 16.8 ABOVE. FOR MISSED EMBEDDED DOWE L, EPDXY EMBED W/ 1/8" OVERSIZED HOLE DIA:, 6" EMBED W/ CLEAN HOLE. 17.3. BUILDING SLABS -ON -GRADE TO BE REINFORCED WITH 6x6 10/10 WWF MIN WITH MESH UP CHAIRS OVER 6- MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED GRADE UNO. 17.4. CONTINUOUS FO TINGS, STEM OR MONOLITHIC, TO BE REINFORCED CONTINUOUS, WITH LAPS AS. PER STATED DEVELOPMENT LENGTH IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO MATCH LONGITUD NAL REBAR. 17.6. SOILAND SUBGRADE IS TO BE TERMITE TREATED. 17.7. SLAB FINISHES UNO: MAIN Bo n N.G: STEEL-T-ROWELFrt ' AP.4-oriro,GEi STOTcc-E TROWEL, T-I'lRE6l 9LBB: LIGHT BRE)O or -DRIVEWAY, DRIVEWAY APRON PORCHES/PATIOS: LIGHT BROOM 17.8. GARAGE, AND ALL, EXTERIOR HARD SURFACES TO SLOPE AWAYFROM BLDG MIN 1/8"/FT. 17.11. COLUMN[WALLA JOOTING CENTERLINES SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 17.12. SLOPE GRADES YFROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 10', 4:1 SLOPE MAX. 18. STRUCTURALSTEa ll . GROUT FOR GGLL4MN BASE PLATES SuALL BE NON 81 lRI K _RQt_I..,_PRI ..........A........ 19. LIGHT GAGE METAL STUDS &MISC. METAL FRAMING: 4B 1 A. ^" D.r DI WnN!ZEn 25 rn nn,nunn, . "SE 7n rn CTI IOC 6FV 20. HVAC:II. 21. FRS WOOD FRAMING 21.1. ALL STRUCTURAL LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KID 19%: (Fb FC LUMBER SIZES NO ED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM T THE NATIONAL G DING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN F O WALLS) TO BE #2 S REST PRODUCTS ASSOCIATION. ALL NON -LOAD BEARING FRAMING LUMBER (INTERIOF P.F. OR BETTER. 21.2. ALL WOOD MEMBEI 6lN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL WOOD EXPOSED T THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO W CCA 21.3. SPLICING FOR MU L T I -PLY HEADERS/BEAMS/COLUMNS: -2x4- 10d COMMON MAIL @ 6" OC EACH LAYER STAGGERED. -2x6-2 ROWS 10d C DMMON NAIL @ 12" OC EACH LAYER. -2x8- 3 ROWS 10d C OMMON NAIL @ 12" OC EACH LAYER. -2x10-4 ROWS 10d, OMMON NAIL @ 12" OC EACH LAYER. -2x12- 5 ROWS 1 Od OMMON NAIL @ 12" OC EACH LAYER. -LOCATE SPLICES nnTEn T I.T VER ERG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLY SPACER USED.A!, WITH MINIMUM GA PE,. S..TrED,�E. 21.6. LAMINATEDLUMBHRAND IN&FRUGTION& 24.7. END STUDS OF EXTERIOR FRA00E VA8,66 OR DESIGNATED INTERIGR 81 'EAR WALLS TO ATTAGHTe GONG AG/8=ENDS. 21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO. 22. PLYWOOD SHEATHING: 22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. UPPER PANELS TO Br n TAnurn TO T HE TOP MEMBER OF Ti !I= UPPER DOUI36E TOP P6ATS AND TG RIPA n ST T-BOTTnNe OF Bonv Ain S 6" r r n G" 6DGS n" EDGE WITHIN COF GORNERS. 22.4. FOR ROOF USE 50PLYWOOD AND 8d RINGSHANK GALV NAILS, SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF EAVES/RIDGES/GABLES SPADE FASTENERS S FIELD, ONu v Pnirn WHERE ToENQN�FFRING 5 R D M 23. PE TRUSSES: 23.1. FIELD VERIFY WITH ARCHITECT EXACT LOCATION AND CONFIGURATION BEFORE MODIFYING EXISTING TRUSSES. DO NOT CUT ANY FRAMING MEMBERS OR TRUSSES WITHOUT EXPRESS WRITTEN AUTHORITY FROM THE ENGINEER AND ARCHITECT. 23.2. FIELD VERIFY DIMENSIONS OF NEW PRE-ENGINEERED TRUSSES PRIOR TO CONSTRUCTING. 23.3. CONTRACTOR TO SUBMIT THE TRUSS ENGINEERING TO ARCHITECT TO REVIEW FOR ADHERENCE WITH DRAWINGS PRIOR TO CONSTRUCTION. ARCHITECT'S SEAL WILL NOT BE APPLIED. 23.4. TRUSS CONFIGURATION DRAWN ARE SCHEMATIC ONLY, HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMI G SCHEME SHOWN WILL CLOSELY PARALLEL FINAL LAYOUT MY MFR. EXACT TRUSS WEB, CHORD SIZES AND LAYOUTARETO BE DETERMINED BY THE MFR. TRUSS MFR TO DESIGN ANY PERMANENT BRACIN D REQUIRED FOR STABILITY. 23.5. ALL TRUSSES FURNISHED SHALL BE SUPPLIED WITH SI 3 NED AND SEALED TRUSS DIAGRAMS PROVIDING THE MFR'S TRUSS SPECIFIC REQUIREMENTS FOR BRACING AND LATERAL MOVEMENT. ALL TRUSS -TO - TRUSS CONNECTORS TO BE SUPPLIED BY THE TRUSS MFR. VERIFY THAT THE CAPACITY OF THE TRUSS ANCHORS CALLED OUT ON THE CONSTRUCTION DRAWINGS MEET OR EXCEED THE UPLIFT VALUES ON THE TRUSS ENGINEERING. ANY TRUSS ANCHORS CALLED OUT THATARE OF INSUFFICIENT CAPACITY SHALL BE BROUG HT TO THE ATTENTION OF TH E ARCHITECT FORSUBSTITUTION, U STITUTION. 23.6. BRACE BOTTOM CHORD AS PER MFR SPECS, IF NOT PROVIDED, PROVIDE CONTINUOUS'RAT RUN' LATERAL BRACE PERPENDICULAR TO BC 2x4 @ 12' OC (2) 12d NAILS EA BC. 23.7.. PREFABRICATED WOOD TRUSSES, JOISTS, AND GIRDER TRUSSES SHALL BE DESIGNED TO SUPPORT THEIR SELF -WEIGHT, PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. INCLUDING, BUT NOT LIMITED TO, WALLS EITHER PARALLEL OR PERPENDICULAR TO THE SPAN, ALL MECHANICAL AND OTHER EQUIPMENT, AND SHALL DESIGNED TO RESIST ALL DRAG FORCES, SHEARWALL UPLIFT AND DOWNWARD LOADS, AND OTHER SPECIAL LOADS NOTED ON STRUCTURAL, MECHANICAL, PLUMBING, OR ARCHITECTURAL DRAWINGS OR CALCULATIONS. MINIMUM ALLOWABLE' SHEAR SHALL BE 95 PSI, BRIDGING SIZE AND SPACING SHALL BE AS DESIGNATED BY TRUSS MFR UNLESS NOTES OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS SEALED BY REGISTERED ENGINEER. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICBO APPROVAL. THE MFR SHALL DESIGN CONNECTION OF TRUSS REQUIRING PREFA91RICATEDHARDWARE HANGER OR OTHER. 23.8. FABRICATORTO SUBMIT SHOP DRAWINGS AND CALC' " TONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINE R). SPECIALTY ENGINEER MAY SUBMIT PREFERRED CONNECTION AND OTHER DETAILS IF OF ERENT FROM SAME ON DRAWINGS FOR APPROVAL, 24. CONNECTORS/FASTENERS: 24.1. CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO WEATHER AND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION. 24.2. UPLIFT CONNECTORS MAY BE SUBSTITUTED WITH CONNECTORS WITH a THE DOCUMENTED UPLIFT VALUE IS a SPECIFIED CONNECTOR. UNLESS SPECIFIED UPLIFT CONNECTORS ARE NOT REQUIRED ON LOADBEARING WALLS THATARE NOT SUBJECT TO UPLIFT OR SHEAR. SPACE NAILS AT STRAPS AS TO NOT SPLIT WOOD, USE MINIMUM NAIL QTY REQUIRED. BY MFR. IF MULTIPLE FASTENER OPTIONS USE EITHER UNLESS SPECIFIED. BY ARCHITECT 2& DOORS AND WINDOWS: BFB BB�g2_o l • 26.8. G60,68TO Hnvc O n, F GT n 26.9 SIZES RE Annn n Ann GANVERY '1 2" IN SIZE IF EGRESS 18 NOT EFFEG:FEID, 27. ELECTRICAL & LIGHTING NOTES 27.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND EQUIPMENT, SHALL BE DETERMINED BYAN ELECTRICAL CONTRACTOR AND APPROVED BY THE ARCHITECT. IF LAYOUT/SIZING IS PROVIDED ELECTRICALC CO NTRACTOR TRACTOR TO VERIFY . 27.2. ALL 120V 15A AND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT TYPE. 27.3. PROVIDE AFIC AS DETERMINED BY NEC210.12 OR FBC R 3902. 27.4. PROVIDE GFIC AS DETERMINED BY NEC 210.8 OR FBC -R 3902. 27.5. ALL EXTERIOR OUTLETS TO BE GFIC WITH WEATHER TIGHT PROTECTIVE COVER. 31. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: 31.1. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: -< 31.2. FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9- 302.10 31.3. INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450 31.4. WALUCLG FLAME SPREAD: <200, WALUCLG SMOKE DEVELOPED: <450 32. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: 32.1. WEATHERING: NEGLIGIBLE, TERMITE AREA: VERY HEAVY 33. MISC: 34. FINISHES PER FBn R8 W� 1 8/4" FpAprn,NTA TYP TRANSITION FROM WGGD T-G GC)NG (I E. @ GABLE END) TO I IAVEA 34.3. EXTERIOR T&G WOOD CEILING. ATTACH.tx4 OR 1x6 BOARD W/ 2" 16GA FINISH NAIL EA RAFTER/JOIST/BC. TO CHANGE ORIENTATION USE 2x4 FLAT PURLINS ATTACHED TO EA RAFTER/JOIST/BC W/ (2)16D NAIL. REVIEWER,' f-UH BODE COMPLIANCE ST.' LUCIIE COUNTY 13a.ACC ABBREVIATIONS: AS ANCHOR BOLT AIC AIR CONDITIONER AHU AIRHANDLING UNIT AT ACOUSTICAL TILE B.M. BENCH MARK BM BEAM BC BOTTOM CHORD BILK BLOCK SO BY OWNER BOTT BOTTOM BP BOTTOM PLATE CAI CONTROL (CONSTRUCTION) JOINT CL CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CO CONNECTOR COL.. COLUMN CONIC CONCRETE CONT CONTINUOUS ICU CONDENSING UNIT OR COPPER CW COLD WATER CXN CONNECTION D NAIL SIZE (PENNY) DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DISP DISPOSAL DN DOWN DR DRYER DTL DETAIL DW DRIVEWAY 'E' EXISTING EA EACH EJ EXPANSION JOINT EL BUILDING ELEVATION ELECT ELECTRICAL ELEV ELEVATOR OR ELEVATION EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXP EXPOSED EXT EXTERIOR EXTG EXISTING F1 FOOTING #1 FA FASTENER FD FIELD (FLOOR) DRAIN FE FIRE EXTINGUISHER - FF FINISH FLOOR FIN FINISH FLR FLOOR FP FIRE PROTECTION EPS EXPANDED POLYSTYRENE FTG FOOTING FT FOOT (OR FEET) GALV GALVANIZED GFI GROUND FAULT INDICATOR GSF GROSS SQUARE FEET GWH GAS WATER HEATER GWB GYPSUM WALLBOARD HB HOSE BIB HC HOLLOW CORE HDG HOT DIPPED GALVANIZED HORIZ HORIZONTAL HW HOT WATER HWH HOT WATER HEATER IN INCH INT INTERIOR JT JOINT MAX MAXIMUM MEP MECH/ELECT/PLUMB MFR. MANUFACTURER MIN MINIMUM. MID MASONRYOPENING MW MICROWAVE NIC NOT IN CONTRACT NTS NOT TO SCALE NSF NET SQUARE FEET L-1 LINTEL #1 LF LINEAL FOOT OA OVERALL - OC ON CENTER OAS OR APPROVED SIMILAR. PL PROPERTY LINE OR PLATE PLY PLYWOOD PT PRESSURE TREATED PVC POLYVINYL CHLORIDE R RADIUS R/A RETURNAIR RCB REINFORCED CONCRETE BEAM RCC REINFORCED CONCRETE COLUMN RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCING REQ REQUIRED. R/W RIGHT-OF-WAY RTU ROOF TOP UNIT S. SIMPSON (MFR) SBS STYRENE BUTADIENE STYRENE SEL SITE ELEVATION SF SQUARE FOOT SIM SIMILAR SK SINK SOG SLAB ON GRADE ss STAINLESS STEEL STAG STAGGERED TBD TO BE DETERMINED TC TOP CHORD THE TO MATCH EXISTING TOB TOP OF BEAM TOB TOP OF COLUMN TOS TOP OF SLAB TP TOP PLATE TPO THERMO PLASTIC OLEFIN TYP TYPICAL UG UNDER GROUND UNO UNLESS NOTED OTHERWISE VB VAPORBARRIER VERT VERTICAL VTR VENT THRUROOF W/ WITH WA WASHER MACHINE WP WATERPROOF WD WOOD WWF WELDED WIRE FABRIC/MESH # POUND OR NUMBER E no �d 0 U 00 Ad C 3 - _ a 0 t; U tn„c _ n C = O�O'� N CD - Q U) m C517D O 4) M tD C = t71 E -0 co CV m .0 U) 2 N 1,-_ W 0 Y Cl C M M LLLL ILLU Of U U w z U W a N N F K 0 0 ❑ ❑z a J 0 d U r Lo 3 M ❑ a C") a J tD H Zz m ® U w ❑ l' J LL o n ® ® ° K Q O a w L. Z z U w �-/ LJ� w N O N x f_ i o I m U s y L0 z z w 0 a CO At z¢ z a z 0 v; 9 �d O F- Z W O U W Q 0 general notes 9/24/20' SHEET -1 EDocuSiened by: /I� �� V'AtA.(c ut,l,U E935FAF3GE92486.. 9/24/2020 rSe FF(ORCIP. LIFe AR97108