HomeMy WebLinkAboutProduct Approval (2) a
*` Florida Building Code C}''.ne Page 1 of 5
F
t'OPY
en+�
BCIS Home i Log In User Registration i Hot Topics Submit Surcharge i Stats&Facts i Publications FBC Staff f BCIS Site Map i L
d lorid 11401-wk OProduct Approval
. r USER:Public User
a e_ ^.3s,ttcs.
Product Approval Menu>Product or Application Search>Application List>Application Detail
€(}_
FL# FL11651-R2
Application Type Revision
Code Version 2014 A RE 4U CT"10AIdY1i0Ri"i206;C 5
Application Status Approved "NEOLMIRIr0 SY HtE D If,Si"ECTORS TIIAT
t•r i'�"`:'#'
Comments Archived ns,g` L� n. r,gr� �� > � COMS.
❑
Product Manufacturer Gulf Coast Supply&Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-7852
ray@gulfcoastsupply.com
Authorized Signature Ray Bowen
ray@gulfcoastsupply.com
Technical Representative f`H8108OlAft-ACHM Address/Phone/Email fIG kP8PO ) -M
Quality Assurance RepresentativeIBIpQoe�ry1��
Address/Phone/EmailJflii/y�
Category Roofing
Subcategory -Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licen
Professional Engineer
2 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Daniel S. Kuhn
Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
2 Validation Checklist- Hardcopy Received
Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Ena.odf
FL11651 R2 COI Letter of Name chanoe.pdf
Referenced Standard and Year(of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgs... 3/22/2017
Florida Building Code G '' ae = Page 2 of 5
Sections from the Code COPY
Product Approval Method Method 1 Option D
Date Submitted 07/01/2015
Date Validated 07/10/2015
Date Pending FBC Approval 07/18/2015
Date Approved 08/18/2015
Summary of Products
Go to Page ° Pag
FL# Model,Number or Name Description
11651.1 0.032"Aluminum 5V Crimp 0.032"5 V Crimp Aluminum Roof Panel over 15/32"1
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 1 R2 0325vCrimp 15-
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.odf
Impact Resistant: N/A FL11651 R2 II 14FL11651 1 R2 Metal Roof Pane
Design Pressure: +N/A/-108.5PSF Verified By: Dan Kuhn, P.E. 75519
Other: -108.5 psf @ 12"o.c. Install per manufacturers details. Created by Independent Third Party: Yes
Not for use in HVHZ Zones. Evaluation Reports
FL11651 R2 AE 14FL11651 1 R2 0325vCrimo 15
32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.2 0.032"Aluminum Gulf Lok 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 =
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 14FL11651 2 R2 Metal Roof Pane
Design Pressure: +N/A/-116.OPSF Verified By: Dan Kuhn, P.E. 75519
Other:-52.5 psf @ 5 3/16"o.c. fastener spacing. -116.0 psf @ Created by Independent Third Party: Yes
5 3/16"o.c.fastener spacing. Install per manufacturers details. Evaluation Reports
Not for use in HVHZ Zones. FL11651 R2 AE 14FL11651 2 R2 032Gulfl-ok 16
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.3 1"24ga. Gulf Snap 1"Gulf Snap 24 Ga. 17"wide Roof Panel over 15/32''
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 2 R2 Metal Roof Pane
Approved for use outside HVHZ:Yes FL11651 R2 II 14FL11651 3 R2 1 24GulfSnap 1'
Impact Resistant: N/A 32Plvwood HVHZ..odf
Design Pressure: +N/A/--131.OPS Verified By: Dan Kuhn, P.E. 75519
Other:-67.3 psf @ 24"o.c.clip spacing. -131 psf @ 6"o.c. clip Created by Independent Third Party: Yes
spacing. Install per manufacturers details. For use in HVHZ Evaluation Reports
Zones. FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnap I
32Plywood HVHZ..pdf
Created by Independent Third Party: Yes
11651.4 1" 24ga. VersaLoc 1"VersaLoc 24ga 16.5"Wide Roof Panel over 15/32"
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR I
Approved for use outside HVHZ:Yes 32Plvwood HVHZ..odf
Impact Resistant: N/A FL11651 R2 II 14FL11651 4 R2 Metal Roof Pane
Design Pressure: +N/A/-138.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-71 psf @ 24"o.c. clip spacing. -138.5 psf @ 6"o.c. clip Created by Independent Third Party: Yes
spacing. Install per manufacturers details. For use in HVHZ Evaluation Reports
Zones. FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR
32Plywood HVHZ..odf
Created by Independent Third Party: Yes
11651.5 1"VersaLoc.032"Aluminum 1"VersaLoc.032"Aluminum over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc
Approved for use outside HVHZ:Yes 32Plywood HVHZ..odf
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs... 3/22/2017
Florida Building Code C ie - Page 3 of 5
\ 0FL1',l 51 R2FL11651 5 R2 Metal Roof Pane
Impact Resistant. N/A ;L
r.
Design Pressure: +N/A/-101.OPSF LVE&ified-By:.Dan=Kuhn, P.E. 75519
Other: -63.3 psf @ 24"o.c. clip spacing. -101.0 psf @ 6"o.c. Created by Independent Third Party: Yes
clip spacing. Install per manufacturers details. For use in HVHZ Evaluation Reports
Zones. FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLo
32Plywood HVHZ..pdf
Created by Independent Third Party: Yes
11651.E 1.5" 24ga. Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/3:
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnao
Approved for use outside HVHZ:Yes 32Plvwood HVHZ..odf
Impact Resistant: N/A FL11651 R2 II 14FL11651 6 R2 Metal Roof Pane
Design Pressure: +N/A/-116.OPSF Verified By: Dan Kuhn, P.E. 75519
Other:-86.0 psf @ 24"o.c.clip spacing. -108.5 psf @ 12"o.c. Created by Independent Third Party: Yes
clip spacing. -116.0 psf @ 6"o.c. clip spacing. Install per Evaluation Reports
manufacturers detals. For use in HVHZ Zones. FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnao
32Plvwood HVHZ..pdf
Created by Independent Third Party: Yes
11651.7 1.5" 24ga.VersaLoc 1.5"VersaLoc 24ga. 16"wide Roof Panel over 15/32'
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc
Approved for use outside HVHZ:Yes 32Plvwood HVHZ..pdf
Impact Resistant: N/A FL11651 R2 II 14FL11651 7 R2 Metal Roof Pane
Design Pressure: +N/A/-123.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-59.75 psf @ 24"o.c. clip spacing. -123.5 psf @ 12" Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. For use in Evaluation Reports
HVHZ Zones. FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.8 2" 24ga. MegaLoc 24 Ga. 2" MegaLoc 18"wide Roof Panel over 15/32"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 8 R2 24MegaLoc 18 1
Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 14FL11651 8 R2 Metal Roof Pane
Design Pressure: +N/A/-108.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-71.0 psf @ 24"o.c. clip spacing. -108.5 psf @ 12"o.c. Created by Independent Third Party: Yes
clip spacing. Install per manufacturers details. Not for use in Evaluation Reports
HVHZ Zones. FL11651 R2 AE 14FL11651 8 R2 24MegaLoc 18
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.9 24 Ga. Gulf Lok 24 Ga. Gulf Lok 16"Wide over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 11
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 14FL11651 9 R2 Metal Roof Pane
Design Pressure: +N/A/-96.7PSF Verified By: Dan Kuhn, P.E. 75519
Other:-81.75 psf @ 10-1/4"o.c.fastener spacing. -96.76 psf Created by Independent Third Party: Yes
@ 5-1/8"o.c. fastener spacing. -121.75 psf @ 5-1/8"fastener Evaluation Reports
spacing. -161 psf @ 5-1/8"fastener spacing. Install per FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 1
manufacturers details. Not for use in HVHZ Zones. 32Plywood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.10 24 Ga. Gulf Seam 24 Ga. Gulf Seam 16"Wide Roof Panel over 1x4 Woc
over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 10 R2 24GulfSeam 1E
Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.Ddf
Impact Resistant: N/A FL11651 R2 II 14FL11651 10 R2 Metal Roof Par
Design Pressure: +N/A/-93.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-93.5 psf @ 18"o.c. Install per manufacturers details. Created by Independent Third Party: Yes
Not for use in HVHZ Zones. Evaluation Reports
FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 1
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.11 24 Ga. Gulf Seam 24 Ga. Gulf Seam, 1 3/4"Snap Lock, 18"Wide Roof I
15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs... 3/22/2017
Florida Building Code O"ie Page 4 of 5
Impact Resistant: N/A FL11651 R2 II 14FL11651 11 R2 Metal Roof Par
Design Pressure: +N/A/-108.513SF Verified By: Dan Kuhn, P.E. 75519
Other:-69.25 psf @ 24"o.c. clip spacing. -108.5 psf @ 12" Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. Not for use Evaluation Reports
in HVHZ Zones. FL11651 R2 AE 14FL11651 11 R2 24GulfSeam 1
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.12 26 Ga. 5V Crimp 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 12 R2 265vCrimp 15-
Approved for use outside HVHZ:Yes 32Plywood HVHZ.Ddf
Impact Resistant: N/A FL11651 R2 II 14FL11651 12 R2 Metal Roof Par
Design Pressure: +N/A/-156.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-108.5 psf @ 12"o.c. fastener spacing. -156.5 psf @ 6" Created by Independent Third Party: Yes
o.c. fastener spacing. Install per manufacturers details. For use Evaluation Reports
in HVHZ Zones. FL11651 R2 AE 14FL11651 12 R2 265vCrimp 15
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
11651.13 26 Ga. 5V Crimp 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 13 R2 265vCrimp 15-
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 14FL11651 13 R2 Metal Roof Par
Design Pressure: +N/A/-131.PSF Verified By: Dan Kuhn, P.E. 75519
Other:-94.25 psf @ 16"o.c.fastener pattern. -131.0 psf @ Created by Independent Third Party: Yes
16"o.c.fastener pattern. Install per manufacturers details. Not Evaluation Reports
for use in HV Z-Z s. FL11651 R2 AE 14FL11651 13 R2 265vCrimp 15
i�0lvwood NonHVHZ.Ddf
;� �� ' Created by Independent Third Party: Yes
n l 4'1 t•1 f^9 l'1 /..1 l i •'I
11651.14 U Ll L'-261Ga V CrimpJ L 126 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins o
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 14 R2 265vCrimp 1x4
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.odf
Impact Resistant: N/A FL11651 R2 II 14FL11651 14 R2 Metal Roof Par
Design Pressure: +N/A/-156.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-108.5 psf @ 12"o.c. fastener spacing. -156.5 psf @ 6" Created by Independent Third Party: Yes
o.c. fastener spacing. Install per manufacturers details. For use Evaluation Reports
in HVHZ Zones. FL11651 R2 AE 14FL11651 14 R2 265vCrimp ix.
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.15 26 Ga. Gulf Lok 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32" Ply-
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 15 R2 26GulfLok 16
Approved for use outside HVHZ:Yes 32Plvwood HVHZ.odf
Impact Resistant: N/A FL11651 R2 II 14FL11651 15 R2 Metal Roof Par
Design Pressure: +N/A/-161.OPSF Verified By: Dan Kuhn, P.E. 75519
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing. -121.75 psf Created by Independent Third Party: Yes
@ 5 3/16"spacing. -161.0 psf @ 5 3/16"o.c.fastener spacing. Evaluation Reports
Install per manufacturers details. For use in HVHZ Zones. FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16
32Plywood HVHZ.pdf
Created by Independent Third Party: Yes
11651.16 26 Ga. Gulf Lok 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32" Ply-
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 14FL11651 16 R2 26GulfLok 16
Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 14FL11651 16 R2 Metal Roof Par
Design Pressure: +N/A/-63.5PSF Verified By: Dan Kuhn, P.E. 75519
Other:-63.5 psf @ 5 3/16"o.c. fastener spacing. -121.75 psf Created by Independent Third Party: Yes
@ 5 3/16"fastener spacing. -161 psf @ 5 3/16"fastener Evaluation Reports
spacing. Install per manufacturers details. Not for use in HVHZ FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16
Zones. 32Plywood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.17 26 Ga. GulfPBR 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 17 R2 26GulfPBR 15-32Plywood I`
Approved for use outside HVHZ:Yes FL11651 R2 II 17 R2 Metal Roof Panel Detail.pd
Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs... 3/22/2017
Florida Building Code C e Page 5 of 5
Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes
Other:-59.25 psf @ 24"o.c. fastener pattern. -154.75 psf @ Evaluation Reports
12"o.c. fastener pattern. Install per manufacturer details. Not FL11651 R2 AE 17 R2 26GulfPBR 15-
for use in HVHZ 32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.18 26 Ga. GuIfPBR 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins ov.
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 18 R2 26GuIfPBR 1x4
Approved for use outside HVHZ:Yes 32Plywood HVHZ.odf
Impact Resistant: N/A FL11651 R2 II 18 R2 Metal Roof Panel Detail.pd
Design Pressure: +N/A/-151.7PSF Verified By: Dan Kuhn, P.E. 75519
Other:-100.5 psf-@ 24"o.c. fastener spacing. -151.75 psf @ Created by Independent Third Party: Yes
12"fastener spacing. Install per manufacturer's details. For use Evaluation Reports
in HVHZ Zones FL11651 R2 AE 14FL11651 18 R2 26Gu1fPBR ixz
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
11651.19 26 Ga. GuIfPBR 26 Ga. GulfPBR over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15-
Approved for use outside HVHZ:Yes 32131vwood HVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 19 R2 Metal Roof Panel Detail.od
Design,Pressure: +N/A/-154.7PSF Verified By: Dan Kuhn, P.E. 75519
Other:-60.5 psf @ 24"o.c.fastener spacing. -154.75 psf @ Created by Independent Third Party: Yes
12"o.c.fastener spacing. Install per manufacturer's details. For Evaluation Reports
use in HVHZ Zones. FL11651 R2 AE 14FL11651 19 R2 26GuIfPBR 15-
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
11651.20 26 Ga. GuIfPBR 26 Ga. GuIfPBR over 1x4 Wood Purlins over 15/32"P
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11651 R2 II 20 R2 26GuIfPBR 1x4 15-
Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.pdf
Impact Resistant: N/A FL11651 R2 II 20 R2 Metal Roof Panel Detail.od
Design Pressure: +N/A/-151.7PSF Verified By: Dan Kuhn, P.E. 75519
Other:-94.25 psf @ 24"o.c'.fastener spacing. -151.75 psf @ Created by Independent Third Party: Yes
12"fastener spacing. Install per manufacturer's details. Not for Evaluation Reports
use in HVHZ Zones FL11651 R2 AE 20 R2 26GuIfPBR 1x4 15-
32Plvwood NonHVHZ.pdf
,Created by Independent Third Party: Yes
Go to Page i3a1 Pag
Back Next
Contact Us:: 2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refun
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records reque<_
electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.13E
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department"
address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public rr
not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To de
are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® 'E,::::.. M
_m ..... ............
Credit Card
Safe
F LE COPY
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?p aram=wGEVXQwtDgs... 3/22/2017