Loading...
HomeMy WebLinkAboutQuinlan_Engineering_1ILI NEASbALUMINUM SCREEN DiS14.' I , A.lurninum & Construction Engic._ i,;, � .ra *Plan Types: ❑ Screen Room ❑ Pool Screen/Cage (Removable Screen - Remove screen when wind speed exceeds 75 MPH) ❑ Pool Screen/Cage (Non -Removable Screen — Designed to withstand actual Wind Speed) ❑✓ Car Port ❑ Patio Cover ❑ Other: *Reference: QUINLAN New❑✓ Revisions Date:2/22/2017 *Project Address: 7932 Meadowlark Ln *City: Port St Lucie *Contractor Name: WESCON CONSTRUCTION *Address: 5130 Commercial Dr Suite H *City: Melbourne *Zip Code:32940 *Phone/Fax : 321-259-6789 *Email: snovo@wescon.construction *Choose One: Mail❑ Pick Up❑ Fed Ex*F- 2 No of Copies *For FedEx option got to www.aluminumscreendesign.com and provide FedEx account #) *Payment: Check ❑ Credit Card *0 *(For Credit Card option go to www.aluminumscreendesign.com to pay by credit card) Engineering prepared by: ::ASS Engineer: Michael Thompson, MSc, P.E. (P.E. #47509) 4401 Vineland Road — Suite A6, Orlando, FL 32811 Office:407-734-1470 Cell:407-721-2292 Project Manager: Paul Thomas 386-479-9504 Fax: 888-923-8181 Email: aluminumscreendesign@yahoo.com Website: www.aluminumscreendesign.com CA#30930 ■■ ALUMINUM SCREEN DESIGN MEASDAluminum & Consiruction Engineering *Ultimate Wind Speed (mph): 150 Exposed Category: C Risk Category: Screen Room: Insulated ❑ Pan Roof ❑ Fascia ❑ Wall: Block ❑ Conventional ❑ Uprights _ x Top Plate x Kick Plate Pool Screen/Cage: Dome ❑ Gable❑ Mansard ❑ Gutter❑ Wall: Block❑ Conventional ❑ Beams x I Uprights x Purlin x Car Port: Insulated ❑ Pan ❑✓ Fascia ❑ Wall: Block ❑ Conventional ❑ Beams 2 x 7 Post 3 x 3 Patio Cover: Insulated ❑ Pan ❑ Fascia ❑ Wall: Block❑ Conventional[-] Beams x Post x i Concrete: Existing New: 4" Slab❑ Pier❑Ribbon Footer x Pavers[] Other: Note: In the event that there is a conflict with the design plans and general notes and design standard, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and the general notes and design standard. Engineer: Michael Thompson, MSc, P.E. (PE#47509) 4401 Vineland Road Suite A6, Orlando, FL 32811 (CA#30930)-Ph 407-734-1470/ Fax 407-734-1790. ■■ ALUMINUM SCREEN DESIGN EENEA . _ 1 General Notes & Design Standards (Unscreened Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2014 (51 Edition) Aluminum Design Manual 2010 ASCE 7-10 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -150 MPH (FBC Table 2002.4) (45 psj) Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements: Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com ■■AS D � r'. ALUMINUM SyiiEEN... - - '. "; DESIGN Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum design. All aluminum shall be 6005-T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B18.6.4 specification. Self —tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro-galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be %" Reinforcine Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A185 Welded Wire Fabric shall be ASTM Al85 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Hole Alignment: Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips and foreign matter between contacting surfaces shall be removed before assembly. 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com ENEMAS ■ ALUMINUM SCREEN rFSIG-N ■■AD. _ , Beams & Uprights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 150 MPH PRIMARY HEADER BEAM MEMBERS -OPEN COVERED PATIO -(No Screen Insert) SIZE 3" Pan Roof Span Maximum Roof Span = 6-0" 3" Pan Roof Span Maximum Roof Span = V-0" 3" Pan Roof Span Maximum Roof Span =10' 0" 3" Pan Roof Span Maximum Roof Span=12'-0" 3" Pan Roof Span Maximum Roof Span = 15'-0" 2 X 4 9'-0" 9'-0" 8'-0" 7'-0" 7'-0" 2 X 5 12'-0" 11'-0" 10'-0" 9'-0" 8'-0" 2 X 6 13'-0" 12'-0" 11'-0" 11'-0" 10'-0" 2 X 7 15'-0" 14'-0" 13'-0" 12'-0" 11'-0" 2 X 8 15'-0" * 15'-0" 15'-0" 15'-0" 13'-0" 2 X 9 15'-0" * 15'-0" * 15'-0" * 15'-0" ' 13'-0" 2 X 10 15'-0" ' 15'-0" * 15'-0" * 15'-0" ' 13'-0" Column size is 3 x 3 x 0.13" (1/8") unless noted otherwise with a max height of 9'-0" = (CSR) control < 1.0. Larger span req larger column sae. Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater than 30'. Intermediate/Header Beam: Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds 15 feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of F-0" along the side, 3'-0" along the front and 1/2" along the front interface between the super gutter and the attached pool cage knee riser wall. Edge Distance: Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer. 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com GuiAJLAOJ1 IVAway iv SALt, POO � � �r- kp'r"I_ LAGCr �s,t�S �10 / a���XA o"iui scIff f 4tl rye 7a Nam, Tv 5f— s - Robe," o *J 0 , n ors 4 PkOO-Z' 1 i� pp°,�r�,�► �s 247 w 3� f.001C NPJ�c TO Ste. 1S''-&0 4-MADVErt- TO 3" Ae-*'> bra- Ge ``7 �,p0✓ti- 5-� a DfJ 6oTTN--t 4 r-Asc-I-A- Tr) 14 ATr4 .