HomeMy WebLinkAboutEnergy Calculation Form & Manual J's APR 2 a 7017
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Fgject Name: RENAR SCHWARTZB G t� Builder Name: RENAR HOMES File C®1W
sheet: �i'i 3C� 6A .4J IC,�J�t - Permit Office: ST LUCIE COUNTY �lsr
Pty,,�State,Zip: FT.PIERCE,FL, Permit Number:
Cvrier: Jurisdiction: 661000
Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2)
1. New construction or existing .New(From Plans) 9. Wall Types(1504.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Conc ete Block-Int Insul,Exterior R=4.1 1344.00 ft2
b. Frame-Wood,Adjacent R=11.0 160.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1763.0 sgft.) Insulation Area
5. Is this a worst case? No. a.Under Attic(Vented) R=30.0 1763.00 ft2
6. Conditioned floor area above grade(ft2) 1763 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(190.5 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 370
a. U-Factor: Sgl,U=0.96 190.50 ft2
SHGC: SHGC=0.42
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 35.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 34.0 HSPF:8.50
SHGC:.
Area.Weighted Average Overhang Depth: 1.333 ft.
4 14.Hot water systems
rea Weighted Average SHGC: 0.420
a.Electric Cap:40 gallons
8." _16or Types (1763.0 sgft.) Insulation Area EF:0.920
Slab-On-Grade Edge Insulation R=0.0 1763.00 ft2 b. Conservation features
R= ft2 None
c.'N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.108 Total Proposed Modified Loads: 57.96 PASS
CS
Total Baseline Loads: 60.01 �"�'1�7
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with•the F orida Energy specifications covered by this
Code. calculation indicates compliance =Af
with the Florida Energy Code. H + ,` ' '•- e`arQ
PREPARED BY: -15-e7bre construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
Florida Statutes. 1 c
I hereby certify that this building, as designed, is in compliance +CAD WE
,
with the Florida Energy Cod
-� ' BUILDING OFFICIAL:
OWNER/AGENT: A -
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
i
4135/2017 1:49 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title: RENAR SCHWARTZBERG Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 1763 Lot# 3
Owner: Total Stories: 1 Block/SubDivision: 10
#Units: 1 Worst Case: Yes PlatBook:
Bauder Name: RENAR HOMES Rotate Angle: 225 Street: q-930
_ Pgrmit Office: ST LUCIE COUNTY Cross Ventilation: County: St.Lucie
` diction: 661000 Whole House Fan: City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO .BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Blockl 1763 17630
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms, InfilID Finished Cooled Heated
1 Main 1763 17630 Yes 8 4 1 Yes Yes. Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 188 ft 0 1763 ft2 ---- 0 0 1
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 1910 ft2 366 ft2 Medium 0.96 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1763 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1763 ft2 0.11 Wood
4/26/2017 1:20 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
r
FORM R405-20-14
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
R-Value -Et In Pt In Area R-11211le Fraction Ah-cznr 0
_ 1 N=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.35 0
2 E=>NW Exterior Concrete Block-Int Insul Main 4.0999 41 8 328.0 ft2 0 0.35 0
_ =3 S=>NE Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.35 0
=i4 W=>SE Exterior Concrete Block-Int Insul Main 4.0999 41 8 328.0 ft2 0 0.35 0
5 S=>NE Garage Frame-Wood Main 11 • 20 8 160.0 ft2 0 0.35 0
WINDOWS
Orientation shown is the entered orientation =>)changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>SW 1 Metal Single(Tinted) Yes 0.96 0.42 8.0 ft2 1 ft 4 in 0 ft 6 in None None
2 N=>SW 1 Metal Single(Tinted) Yes 0.96 0.42 45.0 ft2 1 ft 4 in 0 ft 6 in None None
3 N=>SW 1 Metal Single(Tinged) Yes 0.96 0.42 40.0 ft2 1 ft 4 in 0 ft 6 in None None
4 E=>NW 2 Metal Single(Tinted) Yes 0.96 . 0.42 22.5 ft2 1 ft 4 in 0 ft 6 in None None
5 S=>NE 3 Metal Single(Tinted) Yes 0.96 0.42 30.0 ft2 1 ft 4 in 0 ft 6 in None None
6 W=>SE 4 Metal Single(Tinted) Yes 0.96 0.42 45.0 ft2 1 ft 4 in 0 ft 6 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 400 ft2 400 ft2 64 ft 8 ft 1
INFILTRATION
4 Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
�;Wholehouse Proposed ACH(50) .000191 881.5 48.39 91.01 .1392 3
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 34 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 35.6 kBtu/hr 1068 cfm 0.75 1 sys#1
i
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 40 gal 60 gal 120 deg None
4/26/2017 1:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-201+4
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
---Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 370 ft2 Attic 92.5 ft2 Prop.Leak Free Garage --cfm 52.9 cfm 0.03 0.50 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling [ ]Jan Feb [[ ]]Mar [ ]Apr [[ ]Ma X Jun �Xj Jul ri Au Se [ ]Oct [[ ]]Nov ]Dec
Heatin [ j Jan Feb [X]Mar []Apr E ]May l Jun Jul Au �Xj
Sep []Oct (X]Nov f X]Dec
Ventin [ l Jan Feb [[X]]Mar [X]A r ]Ma [ Jun Jul Aug Se [X]Oct [[X]]Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Tye Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit
`v
M'
4/26/2017 1:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
Y '
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD' .
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
:J� y
FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1344.00 ft2.
b.Frame-Wood,Adjacent R=11.0 160.00 ft
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1763.00 ft2
6. Conditioned floor area(ft2) 1763 b, N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor: Sgl, U=0.96 190.50 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Garage 6 370
SHGC: SHGC=0.42 ;
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: NIA ft2 a.Central Unit 35.6 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.0 HSPF:8.50
Area Weighted Average Overhang Depth: 1.333 ft.
Area Weighted Average SHGC: 0.420
8..1yp loor Types Insulation Area 14.Hot water systems
Cap:40 gallons
_�Slab-On-Grade Edge Insulation R=0.0 1763.00 ft2 a.Electric EF:0.92
b.N/A R= ft2
\ N/A R= ft2 None
b Conservation features
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building o�.tKE sr�r�
Construction through the above energy saving features which will be installed (or exceeded) ti - _ _, o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code•compliantfeatures =--
Builder Signature: f Date: �' I_
Address of New Home: -,636 BA a) -w--amity/FL Zip, FP FL �- 5`� "
c0D N*L L�t�
-*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/26/2017 1:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1