Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's APR 2 a 7017 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Fgject Name: RENAR SCHWARTZB G t� Builder Name: RENAR HOMES File C®1W sheet: �i'i 3C� 6A .4J IC,�J�t - Permit Office: ST LUCIE COUNTY �lsr Pty,,�State,Zip: FT.PIERCE,FL, Permit Number: Cvrier: Jurisdiction: 661000 Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2) 1. New construction or existing .New(From Plans) 9. Wall Types(1504.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Conc ete Block-Int Insul,Exterior R=4.1 1344.00 ft2 b. Frame-Wood,Adjacent R=11.0 160.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1763.0 sgft.) Insulation Area 5. Is this a worst case? No. a.Under Attic(Vented) R=30.0 1763.00 ft2 6. Conditioned floor area above grade(ft2) 1763 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(190.5 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 370 a. U-Factor: Sgl,U=0.96 190.50 ft2 SHGC: SHGC=0.42 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 35.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.0 HSPF:8.50 SHGC:. Area.Weighted Average Overhang Depth: 1.333 ft. 4 14.Hot water systems rea Weighted Average SHGC: 0.420 a.Electric Cap:40 gallons 8." _16or Types (1763.0 sgft.) Insulation Area EF:0.920 Slab-On-Grade Edge Insulation R=0.0 1763.00 ft2 b. Conservation features R= ft2 None c.'N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.108 Total Proposed Modified Loads: 57.96 PASS CS Total Baseline Loads: 60.01 �"�'1�7 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with•the F orida Energy specifications covered by this Code. calculation indicates compliance =Af with the Florida Energy Code. H + ,` ' '•- e`arQ PREPARED BY: -15-e7bre construction is completed DATE: this building will be inspected for compliance with Section 553.908 Florida Statutes. 1 c I hereby certify that this building, as designed, is in compliance +CAD WE , with the Florida Energy Cod -� ' BUILDING OFFICIAL: OWNER/AGENT: A - DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. i 4135/2017 1:49 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: RENAR SCHWARTZBERG Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1763 Lot# 3 Owner: Total Stories: 1 Block/SubDivision: 10 #Units: 1 Worst Case: Yes PlatBook: Bauder Name: RENAR HOMES Rotate Angle: 225 Street: q-930 _ Pgrmit Office: ST LUCIE COUNTY Cross Ventilation: County: St.Lucie ` diction: 661000 Whole House Fan: City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO .BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1763 17630 SPACES Number Name Area Volume Kitchen Occupants Bedrooms, InfilID Finished Cooled Heated 1 Main 1763 17630 Yes 8 4 1 Yes Yes. Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 188 ft 0 1763 ft2 ---- 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1910 ft2 366 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1763 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1763 ft2 0.11 Wood 4/26/2017 1:20 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 r FORM R405-20-14 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below R-Value -Et In Pt In Area R-11211le Fraction Ah-cznr 0 _ 1 N=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.35 0 2 E=>NW Exterior Concrete Block-Int Insul Main 4.0999 41 8 328.0 ft2 0 0.35 0 _ =3 S=>NE Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.35 0 =i4 W=>SE Exterior Concrete Block-Int Insul Main 4.0999 41 8 328.0 ft2 0 0.35 0 5 S=>NE Garage Frame-Wood Main 11 • 20 8 160.0 ft2 0 0.35 0 WINDOWS Orientation shown is the entered orientation =>)changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Metal Single(Tinted) Yes 0.96 0.42 8.0 ft2 1 ft 4 in 0 ft 6 in None None 2 N=>SW 1 Metal Single(Tinted) Yes 0.96 0.42 45.0 ft2 1 ft 4 in 0 ft 6 in None None 3 N=>SW 1 Metal Single(Tinged) Yes 0.96 0.42 40.0 ft2 1 ft 4 in 0 ft 6 in None None 4 E=>NW 2 Metal Single(Tinted) Yes 0.96 . 0.42 22.5 ft2 1 ft 4 in 0 ft 6 in None None 5 S=>NE 3 Metal Single(Tinted) Yes 0.96 0.42 30.0 ft2 1 ft 4 in 0 ft 6 in None None 6 W=>SE 4 Metal Single(Tinted) Yes 0.96 0.42 45.0 ft2 1 ft 4 in 0 ft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 64 ft 8 ft 1 INFILTRATION 4 Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 �;Wholehouse Proposed ACH(50) .000191 881.5 48.39 91.01 .1392 3 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 35.6 kBtu/hr 1068 cfm 0.75 1 sys#1 i HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 60 gal 120 deg None 4/26/2017 1:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-201+4 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ---Supply---- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 370 ft2 Attic 92.5 ft2 Prop.Leak Free Garage --cfm 52.9 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [ ]Jan Feb [[ ]]Mar [ ]Apr [[ ]Ma X Jun �Xj Jul ri Au Se [ ]Oct [[ ]]Nov ]Dec Heatin [ j Jan Feb [X]Mar []Apr E ]May l Jun Jul Au �Xj Sep []Oct (X]Nov f X]Dec Ventin [ l Jan Feb [[X]]Mar [X]A r ]Ma [ Jun Jul Aug Se [X]Oct [[X]]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Tye Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit `v M' 4/26/2017 1:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 Y ' FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD' . ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. :J� y FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1344.00 ft2. b.Frame-Wood,Adjacent R=11.0 160.00 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1763.00 ft2 6. Conditioned floor area(ft2) 1763 b, N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Sgl, U=0.96 190.50 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 370 SHGC: SHGC=0.42 ; b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft2 a.Central Unit 35.6 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.0 HSPF:8.50 Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.420 8..1yp loor Types Insulation Area 14.Hot water systems Cap:40 gallons _�Slab-On-Grade Edge Insulation R=0.0 1763.00 ft2 a.Electric EF:0.92 b.N/A R= ft2 \ N/A R= ft2 None b Conservation features 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building o�.tKE sr�r� Construction through the above energy saving features which will be installed (or exceeded) ti - _ _, o in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code•compliantfeatures =-- Builder Signature: f Date: �' I_ Address of New Home: -,636 BA a) -w--amity/FL Zip, FP FL �- 5`� " c0D N*L L�t� -*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/26/2017 1:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1