Project Name: TARPON FLATS LOT 2 - MODEL A
Project Address: 3933 Shore Side Drive Ft. Pierce, FL.
Permit #:
Occupancy Type: R-3 Construction Type: V-B
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
'certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND. ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph ASD x LRFD End Zone Width: 4.98 ft
5. Mean Roof Height 15.33' ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -44.63 Zone 2: -74.76 Zone 3: -74.76 Zone 4: -45.6 Zone 5: -57.8 Garage:
7. Design, Loads: Floor: 138 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that; to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Farid Abuaattas
Signature, Date, and Seal
Print Name
Project Classic LLC
7318 Texas Trail, Boca Raton, FL.
Company Name & Address
PE 72471
1gABUGgTT%,��