HomeMy WebLinkAboutEnergy Calculation Form & Manual J's • 1+
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
1+
Project Name: Lot2TarponFlats Builder Name: Phoenix Realty Homes Inc
Street: - 3933 shore side drive Permit Office:
City,State,Zip: fort pierce,FL, Permit Number:
Owner. Jurisdiction: 151000
Design Location: FL,MELBOURNE REGIONAL_AP County:: Brevard(Florida Climate Zone 2)
1., New construction or existing New(From Plans) 9. Wall Types(2072.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1736.00 ftz
b.Frame-Wood,Exterior R=13.0 336.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? 10.Ceiling Types (1976.0 sgft.) Insulation Area
No a.Roof Deck(Unvented) R=20.0 1976.00 ftz
6. Conditioned floor area above grade(ftz) 1976 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(397.4 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 395.2
a. U-Factor: Dbl,U=0.66 301.44 ftz
SHGC: SHGC=0.32
b. U-Factor: Dbl,U=1.01 96.00 ftz 12.Cooling systems kBtu/hr .Efficiency
SHGC: SHGC=0.30 a.Central Unit 47.0 SEER:16.00
J c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 47.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 5.766 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (1976.0 sgft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1976.00 ftz b. Conservation features
b.WA R= ftz None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.201
Total Proposed Modified Loads: 66.77 PASS
Total Baseline Loads: 69.06
I hereby certify that the plans and specifications covered by Review of the plans and �')< s�'A�,.
this calculation are in compliance with the Florida Energy specifications covered by this
Cade. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: 3/10/2017 this building will be inspected for
compliance with Section 553.908 ,,`
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida EnerMyode.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: p'7-o) DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house.
RE
3/10/2017 4:52 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of�4
FORM R405-2014
PROJECT
Title: Lot2TarponFlats Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1976 Lot#
Owner. Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Phoenix Realty Homes Inc Rotate Angle: 0 Street: 3933 shore side drive
Permit Office: Cross Ventilation: No County: Brevard
Jurisdiction: 151000 Whole House Fan: No City,State,Zip: fort pierce,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,MELBOURNE_REGI FL_MELBOURNE_REGI 2 45 90 70 75 369 69 Medium
BLOCKS
Number Name Area Volume
1 Block1 1976 18376.8
5
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Intl ID Finished Cooled Heated
1 Main 1976 18376.8 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 186 ft 1976 f12 ---- 0.31 0 0.69
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Metal 2210 ft2 494 f12 Medium 0.65 N 0.65 No 20 26.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 1976 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) Main 0 Blown 1976 ft2 0.11 Wood
3/10/2017 4:52 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
^y - -
1 NE Exterior• Concrete Block-Int Insul Main 4.1 32 0 9 4 298.7 ft' 0 0. 0.6 0
2 SE Exterior Concrete Block-Int Insul Main 4.1 48 6 9 4 452.7 f12 0 0 0.6 0
3 SW Exterior Concrete Block-Int Insul Main 4.1 41 0 9 4 382.7 ft2 0 0 0.6 0
4 NW Exterior Concrete Block-Int Insul Main 4.1 31 6 9 4 294.0 ft2 0 0 0.6 0
5 - Exterior Frame-Wood Main 13 36 0 9 4 336.0,ft2 0 0.23 0.3 0
6 SW Exterior Concrete Block-Int Insul Main 4.1 18 0 9 4 168.0 ft2 0 0 0.6 0
7 NW Exterior Concrete Block-Int Insul Main 4.1 10 0 9 4 93.3 1112 0 0 0.6 0
8 NE Exterior Concrete Block-Int Insul Main 4.1 5 0 9 4 46.7 111:2 0 0 0.6 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 NE Insulated Main None .25 3 8 24 ft2
2 - Wood Main None 25 2 8 8 21.3 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 NE 1 Metal Low-E Double Yes 0.66 0.32 8.3 ft2 2 ft 0 in 0 ft 2 in None None
2 NE 1 Metal Low-E Double Yes 0.66 0.32 31.0 ft2 3 ft 0 in 11114 in None Exterior 5
3 NE 1 Metal Low-E Double Yes 0.66 0.32 31.0 ft2 2 ft 0 in 0 ft 2 in None Exterior 5
4 NE 8 Metal Low-E Double Yes 0.66 0.32 10.7 ft2 9 ft 2 in 1 ft 4 in None None
5 SE 2 Metal Low-E Double Yes 0.66 0.32 13.3 ft2 2 ft 0 in 0 It 2 in None None
6 SE 2 Metal Low-E Double Yes 0.66 0.32 26.7 ft2 2 ft 0 in 0 ft 2 in None None
7 SW 3 Metal Low-E Double Yes 0.66 0.32 84.4 ft2 2 ft 0 in 0 ft 2 in None None
8 SW 3 Metal Low-E Double Yes 0.66 0.32 31.7 1112 2 ft 0 in 0 ft 2 in None None
9 SW 3 Metal Low-E Double Yes 0.66 0.32 38.0 ft2 2 ft 0 in 0 ft 2 in None Exterior 5
10 SW 6 Metal Low-E Double Yes 1.01 0.3 96.0 f12 13 ft 0 in 0 ft 1 in None None
11 NW 7 Metal Low-E Double Yes 0.66 0.32 20.0 ft2 18 ft 8 in Oft 1 in None None
12 NW 4 Metal Low-E Double Yes 0.66 0.32 6.3 ft2 2 It 0 in 0 ft 2 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 483 1112 384 ft2 57 ft 9.3 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess .0005 2591.5 142.27 267.56 .365 8.4613
3/10/2017 4:62 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
HEATING SYSTEM
# .System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:9 47 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:16 47 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
' DUCTS
—Supply-- --Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool
1 Attic 6 395.2 ft Attic 98.8 ft2 Proposed Qn Attic —cfm 118.6 cfm 0.06 0.50 1 1
TEMPERATURES
Programabl[e]Thermosta[[t:]]Y Ceiling Fans: rl
[]
Nov Dec
Heating [X]Jan [X]Feb Mar Apr May MJ Apr May un ri
Jul rl Aug Sep Oct lX Nov Dec
Venting [ ]Jan [ ]Feb X Mar Jun Jul Aug Sep
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
Runtime Vent 58 0 0 1-Electric Heat Pump % 1-Central Unit
3/10/2017 4:52 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
laTr
Manual S Compliance Report Job: Lot 2 Tarpon Flats(Mod...
DEL,"'" iR; Date: 3/10/2017
• xro�o Entire House By: fjf
DEL-AIR HEATING &AIR CONDITIONING
o
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Mb:WWW.DEL-AIR.COM
Project • •
For: Phoenix Realty Homes Inc
FL
Cooling Equipment
Design Conditions
Outdoor design DB: 90.6°F Sensible gain: 32566 Btuh Entering coil DB: 75.8°F
Outdoor design WB: 77.8°F Latent gain: 7696 Btuh Entering coil WB: 63.8°F
Indoor design DB: 75.0'F Total gain: 40262 Btuh
Indoor RH: 50% Estimated airflow: 1567 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Trane Model: 4TWR6048H1+TEM6AOD48H41++TDR
Actual airflow: 1567 cfm
Sensible capacity: 35381 Btuh 109%of load
Latent capacity: 10492 Btuh 136%of load
Total capacity: 45873 Btuh 114% of load SHR: 77%
Heating Equipment
Design Conditions
Outdoor design DB: 43.1'F Heat loss: 32162 Btuh Entering coil DB: 68.8°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Trane Model: 4TWR6048H1+TEM6AOD48H41++TDR
Actual airflow: 1567 cfm
Output capacity: 47000 Btuh 146% of load Capacity balance: 34 'F
Supplemental heat required: 0 Btuh Economic balance: -99 'F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1567 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 'F
Meets are all requirements ofACCA Manual S.
W ' 2017-Mar-10 17:18:07
Right-Suite®Universal 2017 17.0.16 RSU24019 Page 1
..nstruction)\Lot2TarponFlatslLot2TarponFlats.rup Calc=MJ8 House faces:NE
�� .i
I 1
1 j
DEL"'
.. Component Constructions Job: Lot 2 Tarpon Flats(Mod...
L.AIR.
Date: 3/70/2017
l + � Entire House By: fif
DEL-AIR HEATING &AIR CONDITIONING
7 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-W53 Nkb:WWW.DEL-AIR.COM
Project • •
For: Phoenix Realty Homes Inc
FL
Design Conditions )
Location:` Indoor: Heating Cooling
Melbourne Regional, FL, US Indoor temperature(T) 70 75
Elevation: 26 ft Design TD (T) 27 16
Latitude: 28°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) -0.2 59.2
Dry bulb(°F) 43 91 Infiltration:
Daily range(T) - 15 ( L ) Method Simplified
Wet bulb(T) - 78 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg-HTM Loss Clg HTM Gain
tP BWh/ft'-T fF-°F/9Wh Bluhff BWh BWhff Btuh
Walls
13A-2ocs:Blk wall,stucco ext,r-2 ext bd ins,8"thk,1/2"gypsum ne 240 0.201 0 5.41 1298 5.07 1218
board int fish se 413 0.201 0 5.41 2230 5.07 2093
sw 300 0.201 0 5.41 1624 5.07 1524
nw 361 0.201 0 5.41 1951 5.07 1831
all 1314 0.201 0 5.41 7103 5.07 6665
Partitions
12C-Osw:Frm wall,r-13 cav ins,1/2"gypsum board int fish,2"x4" 315 0.091 13.0 2.45 770 1.66 522
wood frm,16"o.c.stud
Windows
2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, ne 8 0.660 0 17.8 148 32.2 268
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(4.17 It
window ht,0.17 ft sep.);6.67 It head ht
2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, ne 31 0.660 0 17.8 550 32.2 998
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);3 It overhang(5.17 ft
window ht,1.33 ft sep.);6.67 ft.head ht
2A-2om:2 glazing,clr low-e outr,air gas,mg no brk frm mat,clr innr, ne 31 0.660 0 17.8 554 32.2 1005
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(5.2 ft
window ht,0.17 It sep.);6.67 ft head ht
2B-2fm:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, ne 11 0.660 0 17.8 189 32.2 343
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);9.17 ft overhang(8 ft
window ht,1.33 ft sep.);6.67 ft head ht
2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, se 13 0.660 0 17.8 237 22.9 305
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(5 It se 27 0.660 0 17.8 473 22.9 611
window ht,0.17 It sep.);6.67 ft head ht all 40 0.660 0 17.8 710 22.9 916
2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, sw 84 0.660 0 17.8 1499 24.9 2104
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(6.33 ft sw 32 0.660 0 17.8 562 24.9 789
window ht,0.17 ft sep.);6.67 ft head ht sw 38 0.660 0 17.8 675 24.9 947
all 154 0.660 0 17.8 2736 24.9 3841
2A-2omd:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, sw 96 1.010 0 27.2 2608 22.0 2116
1/4"gap,1/8"thk;NFRC rated(SHGC=0.30);13 ft overhang(8 ft
window ht,0.08 ft sep.);6.67 ft head ht
Wrightsaw
2017-Mar-1017:18:07
- Right-Suite®Universal 2017 17.0.16 RSU24019 Page 1
...nstruction)1Lot2TarponFlats%Lot2TarponFlats.rup Calc=MJ8 House faces:NE
1
IOC-m:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, nw, 20 0.660 0 17.8 355 22.5 451
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);18.67 ft overhang(8 ft
window ht,0.08 ft sep.);6.67 ft head ht
2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, nw, 6 0.660 0 17.8 112 32.2 204
1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(3.17 ft
window ht,0.17 ft sep.);6.67 ft head ht
Doors
11 DO:Door,wd sc type ne 24 0.390 0 10.5 252 11.6 278
n 21 0.390 0 10.5 224 11.6 248
all 45 0.390 0 10.5 476 11.6 526
Ceilings
16X19-Omd:Attic ceiling,mtl roof mat,r-20 roof ins,1/2"gypsum board 1976 0.408 19.0 1.52 3009 1.53 3017
int fish
Floors
22A-tpl:Bg floor,light dry soil,on grade depth 186 0.989 0 26.6 4948 0 0
2017-Mar-1017:18:07
Right-Suite®Universal 2017 17.0.16 RSU24019 Page 2
...nstruction)\Lot2TarponFlats\Lot2TarponFlats.rup Cale=MJ8 House faces:NE
A
Pro ect Summa Job: Lot 2 Tarpon Flats(Mod...
Date: 3/10/2017
Entire House By: fjf
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax,407-333-3653 Mb:WWW.DEL-AIR.COM
Project • •
For: Phoenix Realty Homes Inc
FL
Notes:
Design Information
Weather: Melbourne Regional, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 43 °F Outside db 91 'F
Inside db 70 °F Inside db 75 'F
Design TD 27 'F Design TD 16 'F
Daily range L
Relative humidity 50 %
Moisture difference 59 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26631 Btuh Structure 28864 Btuh
Ducts 3816 Btuh Ducts 2708 Btuh
Central vent(58 cfm) 1715 Btuh Central vent(58 cfm) 994 Btuh
Outside air Outside air
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 32162 Btuh Use manufacturer's data _
Rate/swingg multiplier 1.00
Infiltration Equipmenfsensible load 32566 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2729 Btuh
Ducts 2635 Btuh
Central vent(58 cfm) 2332 Btuh
Heatingg Cooling Outside air
Area(ft2) 1976 1976 Equipment latent load 7696 Btuh
Volume(ft3) 18431 18431
Air changes/hour 0.26 0.14 Equipment total load 40262 Btuh
Equiv.AVF(cfm) 80 43 Req. total capacity at 0.76 SHR 3.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade TRAN E Trade TRAN E
Model 4TWR6048H 1 Cond 4TWR6048H 1
AHRI ref 7563627 Coil TEM6AOD48H41++TDR
AHRI ref 7563627
Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER
Heating input Sensible cooling 35720 Btuh
Heating output 45500 Btuh @ 47°F Latent cooling 11280 Btuh
Temperature rise 26 'F Total cooling 47000 Btuh
Actual air flow 1567 cfm Actual air flow 1567 cfm
Air flow factor 0.051 cfm/Btuh Air flow factor 0.050 cfm/Btuh
Static pressure 0.44 in H2O Static pressure 0.44 in H2O
Space thermostat Load sensible heat ratio 0.81
Capacity balance point=34°F
Backup:
Input=0 kW, Output=0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wM'r tt0ft' Right-Suite®Universal 17.0.16 RSU24019 2017-Mar-10 17:18:07
Ah
Pagel
...nstruction)1Lot2TarponFlats\Lot2TarponFlats.rup Cale=MJ8 House faces:NE
Job: Lot 2 Tarpon Flats(Model A)
pIL�-r Right-J®Works heet Date: 3/10/2017
Entire House
By: fjf
DEL-AIR HEATING &AIR
531 CODISCO WAY,SANFORD,FL32 COND4o ION66655C'Fax 407-333-3853 Mb:WWW.DEL-AIR.COM
1 Room name Entire House Mstr Bdr n
2 Exposed wall 186.0 ft 41.0 ft
3 Room height 9.3 ft 9.3 ft heat/cool
4 Room dimensions 16.0 x 15.0 ft
5 Room area 1975.5 ft2 240.0 112
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-°F) (BtutVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gnus N/P/S Heat Cool
6 - 13A-2ocs 0:201 ne' S.41 , S 61 345 24b 71298 .'1218 '' .0 0 m 0 D
2A 2om o;sso ne- y�7s s 32zb v. a o 148 268 0 0 0 0
2A tom 065tl nee= ,. 47.7b 32:20 31 0 550 998 D 0 0 0
2A 2orr 0660 ne:` 17,75` '32.2D' 31' 0 554 1005 0 0 0 0
11 2B 2fm 0.660 'nw 17 75 32.20 11 .0 189 343 0 0 0 0
11Q.Q-�...-..:,.. �Q'.394_ner _10,49.'. AIL60'_ ..e 24 24_ 252 0
W 13A-2ocs 0.201 se 5.41 5.07 453 413 2230 2093 140 140 757 710
2A-2om 0.660 se 17.75 22.91 13 16 237 305 0 0 0 0
2A-2om 0.660 se 17.75 22.91 27 33 473 611 0 0 0 0
' 13A--2oes; ' Oz201 `sw: 7775.4"T-6V 550 300'1624__1524 ' 149 84 7777469 .425
2A tom w 0.660 swv 17.75 F -24 92', 64 82 1499 2104 34 16 I 600 842
2A om .;P 0.'M isw 17.75 _ 24.82`. 32 31 _;'S52 �789_ 32 15 562 789
2A-2om - 0.660 sw 17:75'--`"24.92 036 -... ,-37 -676 =947 - 0 . 0, 0 D
;P.A-2omd __ t 010-sw__.._,27..17. -: 2204 96.�.:.�. J92 2608 w' 2116 0 ..�Q .L.Lb �0
IW 13A-2ocs 0.201 nw 5.41 5.07 387 361 1951 1831 93 73 396 372
IOC-m 0.660 nw 17.75 22.54 20 0 355 451 20 0 355 451
2A tom 0.660 nw 17.75 32.20 6 0 112 204 0 0 0 0
� 12C-0sw 0 091 777146 7 1A 336�-''"""37b 70 -522
.11D .`0 _ 0390_nL_10.49 s_...lm- 21 �_ 21 224 248 0 _.W`-0 x 0_ 0.
C 16X19-0md 0.408 1.52 153 1976 1976 3009 - 3017 240 240 366 367
2 �Q969..
- -
--
777777
- -
--a .�=..
6 c)AED excursion 2474 810
Envelope loss/gain 24270 23347 4580 4765
12 a) Infiltration 2361 737 520 163
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 5 1150 1 230
Appliances/other 3630 600
Subtotal Qines 6 to 13) 26631 28864 5100 5758
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 26631 28864 5100 5758
15 Duct loads 14% 90/0 3816 2708 14% 9% 731 540
Total room load 30447 31572 5831 6298
Air required(cfm) 1567 1567 3W 313
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrlu111ttager Right-Suite®Universal 2017 17.0.16 RSU24019 2017-Mar-1017:18:08
Aft Pagel
...nstruction)1Lot2TarponFlats%Lot2TarponFlats.rup Calc=MJ8 House faces:NE
= II:�E .�- i Right-J®Worksheet Job: Lot 2 Tarpon Flats(Model A)
"`�"'''"� Entire House Date: 3no/2g17
DEL-AIR HEATING &AIR By: fjf
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:WWW.DEL-AIR.COM
1 Room name Mstr WC Mstr WIC
2 Exposed wall 6.0 ft 0 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 4.0 x 6.0 ft 6.0 x 11.5 ft
5 Room area 24.0 ft' 69.0 ft'
Ty Construction U-value Or HTM Area (ft� Load Area (ftl Load
number (Btuh/ffl-°F) (Btuh/ft5 or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gnus N/P/S Heat Cool
6 n 13A 2ocs 0 201 ne 5 41 5 07"'� d ""'.'�'0 0 0 0 0-0 rk
2A2om ar � 0660, de 1775 '3Z20� �{1 e0 0 0 0 0 0 �-0
2A 2om 0.680'_ne 17.75 �.3220 00 0 = 0 0 : - 0 0 0
ZA tom '0.660 �e. 17.75 32.20 0 0 0 0 0 0 q 0
11 26 2fm 0.660 pe` ---17.75 32.20 0 D D 0 0 0 0 _ 0'
p ;° p.• Q per, =.q,
IW 13A-20cs 0.201 se 5.41 5.07 56 43 231 216 0 0 0 0
2A-2om 0.660 se 17.75 22.91 13 8 237 305 0 0 0 0
2A 2om 0.660 se 17.75 22.91 0 0 0 0 0 0 0 0
13A 2ocs' 0.2Di_�sw 6- 5.-- ..0 • ,0- 0 ; D `�0- 0 -.U 0'
2A 2om 0.660 "sw 17.75 24.92 0 0 0 0 0 0 0 t?
2A2om 066D sw�. 1775; 24.92` 0 00 0 0 0 0 '0;
ZA:2omd 1 �sw 177b:. •24.92_ �.;Q 0 0 0 0 0 0 0
2A 2om,a a 0. .
01D sttt_ _ 27,.17` 2204 -0 0 �'a`6 0 D D -• D �4
W 13A-2ocs b 0.201 nw 5.41 5.07 0 0 0 0 0 0 0 0
10C-m 0.660 nw 17 75 22.54 0 0 0 0 0 0 0 0
2A-2om 0.660 nw, 17.75 32.20 0 0 0 0 0 0 0 0
12C w OA91 245-1.66 ;0 0 0 0 0 0 6 0
0:3g0. n 10.49 L,��:11.60 w ..0 L..,.w..:_:::,:.:.0.__. `'D
C 16X19-0md 0.408 1.52 1.53 24 24 37 37 69 69 105 105
F 22A tp1 `° Q.989 �26.60. O.OD 24 6 t60 . . 069 b 0 0
777 -~
'7-7
-- -7 7-
M _ x
6 c)AED excursion 35 -3
Envelope loss/gain 663 593 105 102
12 a) Infiltration 76 24 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 01 0
Subtotal(lines 6to 13) 740 617 105 102
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 740 617 105 102
15 Duct loads 14-A 9%1 106 58 140/0 91/0 15 10
Total room load 846 675 120 112
Air required(cfm) 44 331 6 6
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
w I kolt waft- 2017-Mar-10 17:18:08
Right-Suite®Universal 2017 17.0.16 RSU24019 Page 2
...nstruction)\Lot2TarponFlats%Lot2TarponFlats.rup Cale=MJ8 House faces:NE
L'
<< Job: Lot 2 Tarpon Flats(Model A)
UAL-A �'' Right-M Worksheet
'`' "11`` ' Entire House Date: 3Y10/2017
• By: fjf
DEL-AIR HEATING &AIR
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:WWW.DEL-AIR.COM
i
1 Room name Mstr Bthrm Great
2 Exposed wall 12.5 ft 24.5 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 1.0 x 157.5 ft 1.0 x 503.5 ft
5 Room area 157.5 ft' 503.5 ftz
Ty Construction U-value Or HTM Area
number (Btuh/ftz°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 ' 13A=2ocs a°0 20 e 5 41' S.07` "`-'a '-0 0 0 61 26 140 132
2A tom' 0 660 `ne 17.75 32 20 0 0 s 0 0 0 0 0 0
?A 2oni Q660 :ne_t 17.75 32.20 "p, ;0 0 0 c 0 0 0 , Q
2A 2om '+ t)&60 ne' 17:75 322D00 0 0 0 0 0 0
1 i 26 2fm r 0 660 ne 17.75 32 20 0 0 0 0 11 0 189 343
116.0 ��w. .,'Q _"0� �0�.. O. � 24 =�a 24
IW 13A-2ocs 0.201 se 5.41 5.07 117 90 486 'im 0 0 0 0
2A-2om 0.660 se 17.75 22.91 0 0 0 0 0 0 0 0
2A 2om 0.660 se 17.75 22,91 27 16 473 611 0 0 0 0
13A-2acs` 6.201=sw �&M 5.07 i"77 , ',0 0 0 f68 72
2A 2om &660 sw 17.75 24-62` 0 0
2A 2om 0 0 0 0 0 0.
0:660 swr 17 75 ,24.92 6 b �� �0 0 0 0 04
2A 2om 0.660 sW 17 75 24.92 0 0 0 0 0 0 0
:.2A2omd' 1:010_sws_.._.27.A7 ii. 22.64 LLL0 L w 0 D 0 ,96 __ 96 2608 s2116
W 13A-2ocs 0.201 nw 5.41 5.07 0 0 0 0 0 0 0 0
10Gm 0.660 rtw 17.75 22.54 0 0 0 0 0 0 0 0
2A 2om 0.660 nw 17.75 32.20 0 0 0 0 0 0 0 0
120-Osw 7`7 °_ Q.091 2 45'ry 1 66=- U 0-'..'.."s. .,;0 0 7=77b
11D0 _ 0.390_n .___1o.49 -11.60 d "-0 0 0 w ' _0 0 _0 p
C 16X19-0md 0.408 152 153 158 158 240 241 504 504 _ 767 769
-- --- -. -- - --
^z^' „.,.q-fw �..ro':-'-- v�,..�-erne-•---.-,y.....--'--•-
�.w.. '�� ._...- '.....'.:;1,".«-.... ..., " ���'_.+ ram.. �..x.................-..e.,.S»,...•....w...,. .......-::-.........:...-tw �..._.L.._.�w.-
,....tY..s..K._;.
.xq'.""."� 'e' »i .""^r`--^-"- arrrr^•a+- �..-..,..«+tea
-" s.._w..::` w._us.; y.a..... ..,..w..._._
6 c)AED excursion 64 764
Envelope loss/gain 1532 1371 4998 4767
12 a) Infiltration 159 50 311 97
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 3 690
Appliances/other 0 1230
Subtotal(lines 6to 13) 1691 1421 5309 6785
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1691 1421 5309 6785
15 Duct loads 14% 9% 242 133 14% 99/c 761 636
Total room load 1933 1554 6069 7421
Air required(cfm) 99 77 312 3W
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
5 � 2017 Mar-10 17:
Right-Suite®Universal2017 17.0.16 RSU24019 Page 3age 3
...nstruction)1Lot2TarponFlatslLot2TarponFlats.rup Catc=MJ8 House faces:NE
1
s Job: Lot 2 Tarpon Flats(Model A)
AIL-�/4► Right-JO Worksheet
Entire House Date: 311 012 01 7
• DEL-AIR HEATING&AIR By: fjf
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:WWW.DEL-AIR.COM
1 Room name Nook Bdnn 3
2 Exposed wall 18.0 ft 26.5 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 1.0 x 127.0 ft 1.0 x 199.0 ft
5 Room area 127.0 ftz 199.0 ftz
Ty Construction U-value Or HTM Area (ftl Load Area (ftz Load
number (Btuh/ftMF) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
w�_.,.,...... -,. W
6 13A 2ocs y 0201 °ne: 5.4 SD7 0 0 0 0 0 0 0`�� 0
2A2om 0.660 nea_ 1k75 3226 0 0 0 0 0 0 0 °w 0
2A tom F_ r e 0 660 6e- 17:7F' 32 20 .Q :� f 0 0 ', 0 0 0 - b
2A tom ` p"660 net 17;75 ° 3220` 0 0 0 0 0'. 0 0 0
11 2B 2 rn CL660 --he 17.75 32.20 0 0 0 0
_ne-._j0.49 - p �o_w o
W 13A-2ocs 0.201 se 5.41 5.07 0 0 0 0 0 0 0 0
2A-2om 0.660 se 17.75 22.91 0 0 0 0 0 0 0 / 0
2A-2om �0,660 se_ 17.75 22.91 0 0 0 0
w 13A-2ocs;! : 0:201,sw 5:4'(; 5.07 :112 = ,339 -i311 rt 121 83 � 423
2A 2om -, 0,660 '§w 17.Z5 24.92: 51' 25 900 1263 0 0 0 0
2A 2om .,t 60 'sue' �17:75 `,24.92, �0 -0 0 r 0 0 0 0 m= �0
06
2A-2om = O.M sw 17.'M 24.92- 0 0 !o 0;- 38 19 675 a r 24
.2A-2omd-' , 4.010-sw-_: 27.17. _22.04 0_ . - 0 `0
IW •13A-2ocs 0.201 nw 5.41 5.07 56 56 303 284 126 126 681 639
10C-m 0.660 nw 17.75 22.54 0 0 0 0 0 0 0 0
2A 2om 0.660 nw 17.75 32.20 0 0 0 0 0 0 0 0
12C Osw 0. 1 245
11D0 ' - -0.390_n.......10.49 _11.60 0 A 0 0 0 0 Z__0 :;:0
C 16X19-0md 0.408 - 1.52 1.53 127 127 193 194 199 199 303 304
F 72�tp1 U,989 26,6p. O;OL! '`.12Z 1s ,.479 0=0,___,__27='.Z*=6
, - - - -
.._. �,.. 72==': :..:.....:�;. �,-� .__'-.-a`�- as:c:._.m_»�..�..'.a.. ,...
777- _.
--- - -- -
777777-7
g-
- a
6 c)AED excursion 577 411
Envelope loss/gain 2206 2629 2906 2786
12 a) Infiltration 228 71 336 105
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 1 230 0 0
Appliances/other 0 0
Subtotal Qines 6 to 13) 2434 2930 3242 2891
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2434 2930 3242 2891
15 Duct loads 14% 9% 349 275 '140A 9% 465 271
Total roan load 2783 3205 3706 3162
Air required(cfm) 143 159 191 157
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
AW 4Slriglasoft 201741Aar-10 17: e 4
Right-Suite®Universal 2017 17.0.16 RSU24019 Page
...nstruction)%Lot2TarponFlats%Lot2TarponFlats.rup Calc=MJ8 House faces:NE
( Job: Lot Tarpon Flats(Model A
�E .- Right-M Worksheet
Entire House Date: 3/10/2017 .
DEL-AIR HEATING &AIR BY fjf
531 CODISCO WAY,SANFORD,FL 327711CONDITIONINGPh : 073-- 665ax 407-333-3853 Mb:WWW.DEL-AIR.COM
1 Roan name Bthrm 2 Kitchen
2 Exposed wall 6.0 ft 0 ft
3 Room height 9.3 ft heat/cool 9.3 It heat/cool
4 Room dimensions 10.0 x 6.0 ft 11.0 x 14.5 ft
5 Roan area 60.0 ft' 159.5 ft'
Ty Construction U-value Or HTM Area (ftj Load Area (ftl Load
number (Btuh/ft'-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cool Gross WP/S Heat Cool
• "--
6 13A 2oCa3 4.201_ne 5.41:":5.U2 ;0 0 0 , 0 0 =0 0 ,.;< p;
2A-2om o-R 0.66D ne.` 17.75 ZE20 0 0 0 0 0 0 ... 0 '. �': 0
?A tom 0.(60 ne J7.75 3220 0 �0 0 0 0 0 0 0
2A2om D:660 ;ne`a 1Zr75 3220 `� .. t7 �t) "`0 0 0 - 0 0
11 2B 2fm 0.660 ne 17 75 32.20 0 0 0 0 0 p p p
�_. .
10:49; 11,60
W 13A-20cs 0.201 se 5.41 5.07 0 0 0 0 0 0 0 0
2A-2om Q660 se 17.75 22.91 0 0 0 0 0 0 0 0
2A-2om Q660 se 17.75 22.91 0 0 0 0 0 0 0 0
13A- 0,20E sw 541`„ 5.07 0 0 D D 0 0 0_-: 70
�j2A2om �` 4;660`sw=.' -17.75` 24.92.` 'Q 0 0 0 0 D 0 0
2A 2om "s O'66p `sw 1775 ° 24A2-: 0 0 0 0 . 0 `"� 0 0 t7
2A2omO.S60 sw 17.75 2492 0 % 0 0 0 0 0 0
2A:26md_ 7.0101sww....._.27:.17`�°"g22.04 .0 0 D
IW 13A-2ocs 0.201 nw 5.41 5.07 56 50 268 252 0 0 0 0
10C-m 0.660 nw 17.75 22 54 0 0 0 0 0 0 0 0
0.660 nw 17.75 32 20 6 0 112 204 0 0 0 0
12C-0sw: 0.0 2.4
_ 5 1 i% 126�7771 6 308 209 =107 107 :263 178
�1Dp �..�-0:390 z..nr�i0.49 11:6D _ 4 _ 0_ 0 0 0 _ 0 _.� ,:y....._.D.-0
C 16X19.Omd 0_408 - 1.52.1.53 60 60 .91 92 160 160 243 244
.. 160 :a 0 °_ . Ito
7-7777-77
�.
7-
p -" -� _ w
6 c)AED excursion 52 -49
Envelope loss/gain 940 809 506 373
12 a) Infiltration 76 24 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 D
Applianceslather 0 1200
Subtotal(lines 6to 13) 1016 833 5051 1573
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1016 833 506 1573
15 Duct loads 14% 9°/a 146 78 14% 9% 72 148
Total room load 1162 911 578 1720
Air required(cfm) 60 45 30 85
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_� Wr'gh"Cft 2017 Mar-1017: ge 5
Right-Suite®Universal 2017 17.0.16 RSU24019 Page
...nstruction)1Lot2TarponFlats\Lot2TarponFlats.rup Calc=MJ8 House faces:NE
1
R
Job: Lot 2 Tarpon Flats(Model A)
DElr-�4► F Right-JO Worksheet
' Mantra-auec� Entire House y Date: 3/10/2017
DEL-AIR HEATING&AIR By: fjf
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Mb:WWW.DEL-AIR.COM
1 Room name Utility Bdrm 2
2 Exposed wall 6.5 ft 27.0 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 1.0 x 52.5 ft 1.0 x 178.5 ft
5 Room area 52.5 ftz 178.5 ftz
Ty Construction U-value Or HTM Area (ftz Load Area (ft5 Load
number (Btuh/ftl-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 =. 265� 112 •;"-"81 437 7777W
2A 2om ` 0 660 ne, 17 75 32:20; al f -`0 148 268 0 D 0 U.
2A 2om = Q 660 tie: 17:75 z 32 20; 0 0 fl 0 0 0 0 e 0
2A26m s �;` 066D h'e 1775 37-, DM 0 0 0 0 31 0 554 100.4
11 26 2fm 0 660 tie` 17.75 32 20 0 0 0 0 0 0 0 - 0
_iD 0 __ `_0. 0 _.r_.:Q
W 13A-2ocs Q201 se 5.41 5.07 0 0 0 0 140 140 757 710
2A-2om 0.660 se 17.75 22.91 0 0 0 0 0 0 0 0
2A 2om 0.660 se 17.75 22.91 0 0 0 0 0 0 0 0
13A 2ocs" Q2D1 sw 54�' 5 07 0 A 0 0 0 0 0 0
2A 2om 0 660 sw 17*75 24 92 0 0 0 0 0 0 0 .0
2A 2om 0.660 sw= 77 75 24 92 0 e 0 _0 0 0. 0 0 _ 0
2A 2om°: t).680 swr; 17 75 24i92" 0 ',0 0 0 0 0 0 -= A
�7.070-sw---.'27.;17: °22Q4•• U_._�. 0 m_0-� D
IW 13A-2ocs 0.201 nw 5.41 5.07 0 0 0 0 0 0 0 0
10C-m 0.660 nw 17.75 22.54 0 0 0 0 0 0 0 0
—G 2A 2om 0.660 nw 17.75 32.20 0 0 0 0 0 0 0 0
12C-0sw= "` b.091 245 166 c'�6 'y:44 108 7 7 7 73 0 0 0 A
11D0 _ 0.390 _n 34.43:�7.60 _ 2a. 21 224 Y4g 0,_. ~} 6 .;:0
C 16X19-0md 0.408 - 152 153 53 53 80 80 179 179 272 273
F7 =26..6tl,u DA=50 27=T 0.�,: �m 179 2Z 7-18 D:
-.._ wr_ 77777
E77—
w...�..._
'77777777
`— _...,....._.,...,... ..,..._..gym'..,.-. ..M.......,:.Huw...w:_.,.. ��-'.`�'..'. .._: ........ ce:ea._...,;....,
-77
.,.�_..«,,...oxe.. .,.. ----. ....e
6 c)AED excursion -47 -76
Envelope loss/gain 1015 887 2737 2321
12 a) Infiltration 83 26 343 107
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 6001 0
Subtotal(lines 6 to 13) 1098 1513 3080 2428
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
109
14 Subtotal 8 1513 3080 2428
15 Duct loads 14% 9% 157 142 14a/a 9a/a 441 228
Total room load 1255 IW5 3522 2656
Air required(cfm) 65 82 181 132
}- Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. )
• vwrj..mhftolV Right-Suite(g)Universal 2017 17.0.16 RSU24019 2017-Mar-10 17:18:08
...nstruction)\Lot2TarponFlats\Lot2TarponFlats.rup Cale=MJ8 House faces:NE
Page 6
p . Right-JO Worksheet Job: Lot 2 Tarpon Flats(Model A)
' "``"" Entire House Date: 3/10/2017
DEL-AIR HEATING&AIR By: fjf
531 CODISCO WAY,SANFORD,FL 3277111 PPhhND400771O3-26665CFax 407-333-3853 Web:WWW.DEL-AIR.COM
1 Room name Bdrm 4/Den Bthnn 3
2 Exposed wall 18.0 ft 0 ft
3 Room height 9.3 ft heat/cool 9.3 ft heat/cool
4 Room dimensions 12.0 x 12.5 ft 10.0 x 5.5 ft
5 Room area 150.0 ft' 55.0 W
Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load
number (Btuh/ft�°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat I Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 13A 2ocs` _... ..0201— 5W 5 U7''""77 112 81 438 411 0 0
2A tom 0 660 ne 17.75, 32 20 0 0 0 0 0 0 0 0
2A 2om 0 660 ne E 17:7 32 20` 3t 0 5�0 998 0 0 ti 0 d
2A Tom 0 660 ne 17.76 32 20 0 0 0 0 0 0 0 �0
11 262fm Q660 ne 17.75 3220 0 00 0 0 0 0 0
_neW LLA6.49: ._
W 13A-2ocs 0.201 se 5.41 5.07 0 0 0 0 0 0 0 0
2A-2om 0.660 se 17.75 22.91 0 0 0 0 0 0 0 0
2A 2om 0.660 se 17.75 D �" 0 22.9..1 0 0 0 0 0 0 0 0
13A toes 6,201 §w $a1` -'5 07 0 .0 0 0 6" 0
2A tom 0.660 sw 17 75 24 32. 0 0 0 0 0 0 0 0
2A 2om 0.860 sw° 1775- 24 92' 0 0 ° .0 0 0 0 0 0
2A 2om `- 0.680'-sti i 7 75- 24 92, 0 0 0 0 0 0 0 0
_ 2A-2omd-. 1070-sw..........27A7.,,-L:22.04 Q, p 0 D ° _0 0
IW 13A-2ocs 0.201 nw 5.41 5.07 56 56 303 284 0 0 0 0
10C-m 0.660 nw 17.75 22.54 0 0 0 0 0 0 0 0
�-G 2A 2om 0.660 nw 17.75 32.20 0 0 0 0 0 0 0 0
�( 12C Osw 0:091 2 45 168'� ;0 '07'7-7 0 0 D 0 , ,. "0 `" 0
�-D:11D0 ._._0.390_n _..10.49. .11.60 0Q 0 0 0, 0
C 16X19-Qmd 0 408 1.52 1.53 150 150 228 229 55 55 84 84
F_ 2?A-tpl09$9 ___;26.60
µ.. .
7-7 .
77777
w Fa z
s a n
--`-.,,.g.�,°.., ..-,_�--�� emu--•..., ..-..K.�. --;,:�.,- n,..x �;gr .-�-�r,k�.-�.»-7w ,-;-*� ,..._,.,
a ,�,.„.��._
.................-
^-
6 c)AED excursion .60 -3
Envelope loss/gain 1998 1862 84 81
12 a) Infiltration 228 71 0 0
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2227 1933 84 81
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2227 1933 84 81
15 Duct loads 14% 9% 319 181 149/6 9% 12 8
Total mom load 2546 2114 96 89
Air required(cfm) 131 105 5 4
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wrlsh" - 2017-Mar-1017:18:08
Right-Suite®Universal 2017 17.0.16 RSU24019 Page 7
...nstruction)\Lot2TarponFlats%Lot2TarponFlats.rup Calc=MJB House faces:NE
31' ' Duct System Summary Job: Lot2TarponFlats(Mod...
EL'-. ■� Date: 3/10/2017
$� ��'� Entire House By: fjf
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax 407-333-3853 Web:WWW.DEL-AIR.COM
Project • •
For: Phoenix Realty Homes Inc
FL
Heating Cooling
External static pressure 0.44 in H2O 0.44 in H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure 0.38 in H2O 0.38 in H2O
Supply/return available pressure 0.190/0.190 in H2O 0.190/0.190 in H2O
Lowest friction rate 0.217 in/100ft 0.217 in/100ft
Actual air flow 1567 cfm 1567 cfm
Total effective length(TEL) 175 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk
Bdrm 2 h 3522 181 132 0.248 7.0 0x'0 VIFx 53.5 100.0 st3
Bdrm 3 h 3706 191 157 0.342 8.0 Ox0 VIFx 26.2 85.0 st1
Bdrm 4/Den h 2546 131- 105 0.261 7.0 Ox 0 VIFx 45.3 100.0 st3
Bthrm2 h 1162 60 45 0.336 5.0 OxO VIFx 28.1 85.0 st1
ethrm 3 h 96 5 4 0.272 4.0 OxO VIFx 39.8 100.0 st3
Great c 3711 156 184 0.289 8.0 OxO VIFx 31.6 100.0 st3
Great-A c 3711 156 184 0.278 8.0 OxO VIFx 36.5 100.0 st3
Kitchen c 1720 30 85 0.365 6.0 Ox 0 VIFx 19.0 85.0 st1
Mstr Bdrm c 3149 150 156 0.218 7.0 Ox 0 VIFx 59.5 115.0 st4
Mstr Bdrm-A c 3149 150 156 0.217 7.0 OxO VIFx 60.3 115.6 st4
Mstr Bthrrn h 1933 99 77 0.225 6.0 OxO VIFx 53.6 115.0 st4
Mstr WC h 846 44 33 0.221 4.0 Ox O VIFx 56.8 115.0 st4
Mstr WIG h 120 6 6 0.224 4.0 Ox 0 VIFx 54.4 115.0 st4
Nook c 3205 143 159 0.337 7.0 Ox 0 VIFx 27.7 85.0 st1
Utility c 1655 65 82 0.343 5.0 OxO VIFx 25.6 85.0 st1
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st4 Peak AVF 449 429 0.217 572 12.0 0 x 0 VinlFlx st3
st3 Peak AVF 1079 1038 0.217 611 18.0 0 x 0 VinlFlx st1
SO Peak AVF 1567 1567 0.217 718 20.0 0 x 0 VinlFlx
Wrl
2017-Mar-1017:18:08
k
Right-Suite®Universal 2017 17.0.16 RSU24019
Pagel
...nstruction)\Lot2TarponFlatslLot2TarponFlats.rup Calo=MJ8 House faces:NE
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk
rb1 Ox0 1567 1567 0 0 0 0 Ox 0 VIFx
i
WriOtSlCft
2017-Mar-10 17:18:08
Right-Suite®Universal 2017 17.0.18 RSU24019 page 2
...nstruction)\Lot2TarponFlats\Lot2TarponFlats.rup Calc=MJ8 House faces:NE
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
.ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index,the more efficient the home.
3933 shore side drive, fort pierce, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1736.00 ft'
b.Frame-Wood,Exterior R=13.0 336.00 ftZ
3. Number of units,if multiple family 1 c.WA R= ftZ
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Roof Deck(Unvented) R=20.0 1976.00 fN
6. Conditioned floor area(ftz 1976 b.N/A R= ftZ
7. Windows"' Description Area c.N/A R= ft
a. U-Factor: Dbl,U=0.66 301.44 ft' 11.Ducts R ftZ
SHGC: SHGC=0.32 a.Sup:Attic,Ret:Attic,AH:Attic 6 395.2
b. U-Factor: Dbl,U=1.01 96.00 ftZ
SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 47.0 SEER:16.00
3 SHGC:
d. U-Factor: N/A ft' 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 47.0 HSPF:9.00
Area Weighted Average Overhang Depth: 5.766 ft.
Area Weighted Average SHGC: 0.315
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1976.00 ft EF:0.95
b.N/A R= ftz
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building „ass
Construction through the above energy saving features which will be installed(or exceeded) a `
in this home before final inspection. Otherwise; a new EPL Display Card will be completed
,• c' ..
based on installed Code compliant features.
Builder Signature: Date: - )7
Address of New Home: City/FL Zip: &V9 � * g�
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/10/2017 4:62 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: 3933 shore side drive Permit Number:
fort pierce,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code ;
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces.New wood-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
`O R402.4.3 Fenestration air IeakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/ VDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.2.2 Sealing(MandatoryAll ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(2513a)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code. r {-
3/10/2017 4:52 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page'1�f'3 l�
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
' ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3%:inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from.the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times•greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
3/10/2017 4:52 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be'adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may'be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
R403.6.1.2.3 Fossil fuel heating equipment The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
e 1.. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55'F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. . Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid.cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting'equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
3/10/2017 4:52 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Lot2TarponFlats Builder Name: Phoenix Realty Homes Inc
Street: 3933 shore side drive Permit Office:
City,State,Zip: fort pierce,FL, Permit Number:
Design Location: FL,MELBOURNE_REGIONAL_AP Jurisdiction: 151000
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
w„
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Leakage Divide by
(Total Conditioned Floor Area)
(Qn,Out)
I certify the tested duct leakage to outside,Qn, is
not greater than the proposed duct leakage Qn Duct tightness shall be verified by
testing to Section 803 of the RESNET
specified on Form R405-2014. g
Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes. ,
SIGNATURE:
PRINTED NAME: ,pD,
DATE: BUILDING OFFICIAL:
DATE:
3/10/2017 4:53 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant J�(C.fagPW(
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance)Method
Applications for compliance with the 2014 Florida Building Code,Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page)and an input summary checklist that can
be used for field verification(usually 4 pages/may be greater).
❑ Energy Performance Level(EPL)Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1-
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage° then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge®-USRCSB v5.1
3/10/2017 4:50:41 PM Page 1 of 1
1
FORM R405-2014
4� TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot2TarponFlats Builder Name: Phoenix Realty Homes Inc
Street: 3933 shore side drive Permit Office:
City,State,Zip: ' fort pierce,FL, Permit Number:
Owner: Jurisdiction: 151000
Design Location: FL,MELBOURNE_REGIONAL_AP
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls.adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have
gasketed doors
3/10/2017 4:53 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
- HONEYWELL Y8150 FpESH
AIR VENTILATIGN SYSTEM ,
SNAP orx, .ABLE -x �'� '
• nwar"MIT
NWcmm
Y61a6 FRESH AIR IM-01 WALL\6P a g U SD
INSULATE W LS IN LIT
gurslPE AIR ncrAa TO 7a1.EAP
. ss IeLLe ray
.cd IEai
I �a2�d, 1 ]'RltNen vent
. ]. ]• W raoP mp .
4• �� 14.14
I 7s bca e14 1.ca 1ia6✓'bca Vl
a ductIV 4.14 ray to
to roof cap c1.w ] m
w/fan-light fig` 14A . 14.9 . Z
Nutone 763RLNB
1.. 3' bath duct �
to roof cap
�-rl a6LL61aray a w/fan w EU -
m 1m61.rd Nutone 696RNB
3' bath duct - 4 Ilya en, s' fo.a 1.aa a
to.roof cap 4 107. 45
w/fan s.
Nutone 696RNB ILI rway - 42X42 A/C SLAB
BY BLDR MIN
]• Ie Para ]• .. - f6 2' FROM WALL
ua ea• su W .-
6• f
Y mpaF to a64 -
- - -
Ln
• Traner.r N W Nl.e el..d In ..r W d .
a.nPua�..nh nand Re.W.nyal eJldnyy COM- ¢*d
4.0 taN V/eNV eHOV IPH
HI6024 jl.
R.tvn Air .nPlloru l-3 Bidder IgLL6 plan
eS provdle unrotrlalea 1 hch E416 lad N S_O
mro.!on ao.r.m namtm4 axu�nxu 811;s,p Attsc Z J O N
W
row • .. O �L�
xo. a��
.. EL f N F-P')LL.
Rating o r
4 � m
9 Z •• o ..
• Sg'o � a �
Must hay..o NMnun clearance aF 4 Inches around the air hdndler per th..Stat.Energy code..' All.duct has on r-6 Insulation volue•
RECEIVED
V APR 1.3 2017
St.Lucie G_ 11t„FL