HomeMy WebLinkAboutCarports Anywhere - K Wurtenberg - 403012-Rev8 - Digital Sealed0 0 I r7 m m m m m FRAME FRAME ----- - - - - - ---------- - ---- ---------- ---------------------------------------------------------------- ------ 12"x12" REINFORCED FOOTER m -0" 3'-0" FRAME f3tr�----------------------------------------- -TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION CONCRETE: -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS -ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS: -MINIMUM GRADE 40 STEEL -REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: -THE REBAR IS BENT COLD -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. -COVER: -3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 14" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }" FOR FINE GROUT, AND }" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM Al003/A1003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OLB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. 4"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END -WALL POST 12%12" REINFORCED 2" MIN. BASE RAIL FOOTER PERIMETER GRADE -III [M�INIMUM III (2) #5 REBAR 0 6" O.C. SOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 500 PSF (TYP.) 25" OVERLAP SPLICE CONCRETE FOOTER/BASE RAIL ANCHOR DETAIL CODE VERSION IFBC 2020 7th Edition,ll BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph EXPOSURE B ENCLOSURE OPEN INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE INO SQUARE FOOTAGE 11,110 SQ. FT. REV I DESCRIPTON I DATE IBY 1 1EXISTING BUILDING/FRAME OUTS 7/10/20 1 MTB 2 IREVISED FOOTER I 7/23/20 MTB z O LL 5 IMOVED COMPONENTS BACK 9/' 6 371, NO PARTITION WALL 12/1 7 E.T.'s, SHIFTED RUD's & F/O 12/1 8 OPEN, F/0's, 1 RUD 12/� 2 5" PLAN VIEW DOOR FRAMING " RECESS 4 DOOR WIDTH — ELEVATION VIEW DOOR FRAMING RECESS •75'T 4„ OOR WIDT OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 12"x12" REINFORCED ------- /- FOOTER-------FRAME--------------------------------------------------------------------------- F-RAMF---------------------- OUT ----------- ---------------f20Lt=�f'----------------------------------------- OUT DOOR �-2'-0" I 7'-0" L 9'-0" I 8'-0" _ I. 2'-0" -I- 7'-0" G MTB 7/7/20 S. Indian River Dr., Ft. Pierce 371 X 30'W X 12'H \,\CENS, NO. 64608 t 2 i % STATE OF :•441 L 0 R I 0 011lllll��� Digitally signed bI Matthew Baldwin Date:2020.12.29 W 09:58:53-05'00' z Matthew T. Baldwin P.E. Q Florida License #64608 Cj a_ Sheet: CA-1 OF 4 12 3[::�— 1 FRONT/REAR END WALL o FRAME �r'b ROLL -UP T OUT T DOOR LEFT SIDE WALL _14- FRAME OUT N 3._O'. 3._Q'. 3-01 3._Q'. 3._e].^ 3. ].^ 3 �.^ 3._Q'. 3._e]• 3•_al• FRAME OUT 0 0 FRAME OUT 6 FRAME OUT 3'-0" 2' 0" [2' 3'-0" 10j" 10J" 10`1" 2'-9+j" RIGHT SIDE WALL PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES Ice CODE VERSION FBC 2020 7th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM INONE OCCUPANCY JUTILITY, U WIND SPEED Vult-165mph INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,110 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 1 EXISTING BUILDING/FRAME OUTS 7/10/20 MTB 2 REVISED FOOTER 7/23/20 MTB 3 NO SLAB, ONLY FOOTER 7/24/20 MTB 4 391, MOVED COMPONENTS 8/27/20 MTB 5 MOVED COMPONENTS BACK 9/2/20 MTB 6 371, NO PARTITION WALL 12/11/20 MTB 7 E.T.'s, SHIFTED RUD's & F/O 12/17/20 MTB 8 OPEN, F/0's, 1 RUD 12/29/20 MTB DRAWN BY: MTB DATE: 7/7/20 LOCATIO 603 S. Indian River Dr., Ft. Pierce SIZE: 371 X 30'W X 12'H u> i LLJ 5: 0 Z Q LL C� z LLJ Matthew T. Baldwin P.E. LLJ Florida License #64608 Sheet: CA-2 OF 4 FRAME OUT N FRAME OUT CODE VERSION FBC 2020 7th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B o RISK CATEGORY I a FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph EXPOSURE B ENCLOSURE OPEN INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 30,-0" ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FRONT/REAR END WALL FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,110 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 1 EXISTING BUILDING/FRAME OUTS 7/10/20 MTB 2 REVISED FOOTER 7/23/20 MTB 3 NO SLAB, ONLY FOOTER 7/24/20 MTB 4 391, MOVED COMPONENTS 8/27/20 MTB 5 MOVED COMPONENTS BACK 9/2/20 MTB 6 1371, NO PARTITION WALL 12/11/20 1 MTB ROLL-UPROLL-UP FRAME 7 E.T.'s, SHIFTED RUD's & F/O 12/17/20 MTB DOOR UT 1 8 JOPEN, F/0's, 1 RUD 12/29/20 1 MTB MTB 7/7/20 S. Indian River Dr., Ft. Pierce 37'L X 30'W X 12'H LEFT SIDE WALL PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA w AUTHENTICATION CODE MUST BE VERIFIED ON j FRAME FRAME ANY ELECTRONIC COPIES OUT OUT z W Matthew T. Baldwin P.E. W Florida License #64608 37'-0" Q RIGHT SIDE WALL Sheet: CA-3 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SCREWS 14xi" SELF —DRILLING / NIPPLE TO V � BASE RAIL NIPPLE BASE f POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) # 12-14xj" SELF —DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL I I INTERII MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xi" SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS END POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS VARIES N —1.1 1.1 TO 1 MAX. SPACIN r-3" MIN. }STD. MAX. SPACING OVARIES > SIDE WALL ROLL —UP 1 DOOR/FRAME OUT 1 HEADER DETAIL STALL PER MANUFACTURERS INSTRUCTIONS # 12-14xi" SELF —DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALLY 18" EXTERIOR It 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS INTERMEDIATE POST TO HEADER/BASE RAIL/OR WINDOW RAIL DETAIL MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)# 12-14xj" SELF —DRILLING SCREWS POST TO TRUSS CONNECTION 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14xi" SELF —DRILLING SCREWS '2-1-2-1' (6" O.C. (9" O.C. MAX.)) #14x1" SELF —DRILLING SCREWS ® 6" O.C. MAX. & 6" MAX. FROM CORNERS DOOR FRAME TO POST CONNECTION ROLL —UP DOOR TO POST CONNECTION 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-14x1" SELF —DRILLING SCREWS TO EACH RAFTER. 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS SINGLE OR DOUBLETS HEADER HEADER CONNECTION DETAIL OPTION 1 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14xi" SELF —DRILLING SCREWS '2-1-2-1' (6" O.C. (9" O.C. MAX.)) 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-14x1" SELF —DRILLING SCREWS TO EACH RAFTER. ROOF PANEL CONNECTIO VERTICAL SHEATHING OPTION 001 M Max. EAVE & RIDGE REINFORCED ROOF PANEL CONNECTION (RIDGE 3r AND EAVE 3e� Design Pressures - 165 mph Basic Wind Speed Zone Roof Wall 1 2n 2r 2e 3r 3e 4 5 18.1 20.5 18.1 18.1 26.0 26.0 26.0 29.5 -22.0 -51.3 -42.7 -22.0 -83.1 -71.3 -27.9 :-34.9:] PPLE MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH 12-14xi" SELF -DRILLING EWS SINGLE OR DOUBLETS HEADER HEADER CONNECTION DETAIL OPTION 2 NIPPLE TRUSSED RAFTER CONNECTION DETAIL PPLE TO 1 "x2j" 16 GA. U—CHANNEL BRACE, MII J_ 24" UP TO 7' POST, M 48" OVER 7' POST. MR 45' TO MAX. 60° FROM HORIZ. (EXCLUDE END —WALLS). SECURED WITH (4)#12-14xi" SELF —DRILLING SCREWS MINIMUM 6" TS NIPPLE. NIPPL SECURED TO WALL POST WITH (4)#12-14xj" SELF —DRILLING SCREWS BOX EAVE RAFTER TO APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 — R 1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 L :Ls 'L Ilk � ps'," CODE VERSION FBC 2020 7th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,110 SQ. FT. REVISIONS DESCRIPTON DATE BY 1 EXISTING BUILDING/FRAME OUTS 7/10/20 MTB 2 REVISED FOOTER 7/23/20 MTB rREV 3 NO SLAB, ONLY FOOTER 7/24/20 MTB 4 39'L, MOVED COMPONENTS 8/27/20 MTB 5 MOVED COMPONENTS BACK 9/2/20 MTB 6 371, NO PARTITION WALL 112/11/201 MTB 7 E.T.'s, SHIFTED RUD's & F/0 112/17/201 MTB 8 IOPEN, F/0's, 1 RUD 12/29/20 MTB Cn J_ Q PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND L�j w THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 0 MTB 7/7/20 S. Indian River Dr., Ft. Pierce 371 X 30'W X 12'H Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA-4 OF 4