HomeMy WebLinkAboutEngineering Mle COPY. -D APR 28 2017 T reasure .klaNey E. Koehnen. C Oast r Professional±Engineer#32831 ti :B wilding r �` Architect#AR0009471 ngineers, Certified General Contractor#CGCO24776 Inc. April 27,2017 To: Saint Lucie County Building Department Re: Permit# 1703-0474 Owner: Address: 2504 Isola Bella Dr.Fort.Pierce,FL. Contractor: Treasure Coast Roofing Arch/Eng: TCBE,Harvey Koehnen To Whom It May Concern: This firm was retain to certify the installation of a flat roof that was completed during the re-roof of the above referenced project was done in accordance to our design submitted to your department for review. The following is what our associate found: Plywood Decking All compromised plywood decking removed and replaced with 19/32" plywood. Entire roof plywood decking re-nailed with 8d ringshank nails 6" O.C.thtough-out. Base sheet: Documented proof that low slope CertainTeen Glasbase sheet with min 4" lap fastened with 11 ga.Ringshank nails with 1-5/8"'dia tin caps spaced 4" O.C.in lap and 3 staggered rows 6"O.C. exceeding the requirements of the Florida product approval(FL10497-R5)and our design as submitted to the city. ST.L TCIFE COON'I Y BUIID,;TJG DIVISION ;R.F VIEWED''Ca �IPUkNCE Fcii'I.''.'r`J'G DATE 41 kI4NS AND1'EMITMUST13EA,£E}PT ON JOB, Qar NO INSNXIQN WILL BE T C B E Inc 7205 Elyse Circle Phone (772)466 5509 Fax (772),48973035 a o'.p > a d PortSalnt LUCIe egg � 4 k i x U c eat yr z E-ma�lr ,,,hkoehnen@tcbewebcom a{ h 4w "r�y`ifY yfti j y a}yg tx` ,w Florida 34952 8212 ¢ , ,Web site.http://www.tcbeweb com ? - Cap Sheet: .. Visually inspected Torch applied cap sheet. Not bubbles under cap,no shifting in evidence,or compromised sheets. With these observations we are able to certify that the low slope roof installation of this re-roofing repair meets and/or exceeds our design as submitted to your department,the 2014 FBC 5`"Edition,Florida Product Approval FL-10497-R5,good construction practices, and all local interpretations of the FBC and local ordinances. Addendum: On March 23,2017 your department issued review comments on our last letter. Our responses are as follows:. 1. Corrected spelling of street name on letter above 2. Product approval properly marked and identified has been added to this letter. a. Noted Spacing of base sheet is good for a ASD pressure-90.0 far in excess of the required pressures of-Zone 1: -27.6,Zone 2:46.4,Zone 3:769.8 as required by the 2014 FBC 5t'Edition for flat roofs less than 7 degrees in a 160 exposure B wind zone 3. As per our conversation a pull out test is not required since the entire roof was renailed as observed and listed in our original letter With these corrections and addendums we believe that the work and our description of it now meets all requirements of the 2014 FBC 5t'Edition If you have any questions,please call our office. Respectfully Submitted, ,•`EpWARD� _ �QJV.1.��GEN@F�fy�, TIarvey E. _ehnen,•P.02,831 President - Phone C B E,Inc 7205,0 sb.Circle (772)466 5509 Port in, Lucitn e Faz (772)489,3035 Florida 34952 8212 Email • hkoehnen@tcbeweb _ ! , Web site hftp://www.ttbeweb.'toffi,�'. :�,