Loading...
HomeMy WebLinkAboutProduct Approval % File Copy,_ Business & Professional Regulation, r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map I Links I Search I Florida 1.9 Product Approval USER:Public User tP.SsarlFeStap+ Product Acoroval Menu>Product or Aoollcation Search>Application List>Application Detail ;�OFFJCEOFTHE FL#SEPRETARY FL10497-R5, Application Type Revision Code Version 2014 Application Status Approved Comments Archived O Product Manufacturer Mule-Hide Products Co., Inc. Address/Phone/Email 1195 Prince Hall Dr Beloit,WI 53511-5481 (608)365-3111 Ext 809 lindareith@trinityerd.com Authorized Signature Timothy McFarland lindareith@trinityerd.corri Technical Representative Tim McFarland Address/Phone/Email 1195 Prince Hall Dr Suite A Beloit,WI 535115481 (608)365-3111 tim.mcfarland@mulehlde.como Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer . O Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/28/2017 Validated By John W.Knezevich, PE © Validation Checklist-Hardcopy Received Certificate of Independence FL10497 R5 COI 2015 01 COI Nleminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D6163 2000 ASTM-kQ6164 2005? ASTM D6222 2008 FM 4470 1992 FM 4474 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/16/2015 Date Validated 12/16/201S Date Pending FBC Approval 12/17/2015 Date Approved 02/10/2016 Summary of Products Model,Number or Name Description 10497.1' Mule-Hide SBS and APP Modified _Self-adhering mo_dified_b_itumen roof sys_te s Bitumen Roof_Syste-ms, Limits of Use iInstallation Instructions) Approved for use in HVHZ:No :Fl 10497 R5 II 2015 12 FINAL Al ER MULE-HIDE FLID497 Approved for use outside HVHZ:Yes 'RS.Ddf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-480 Created by Independent Third Party: Yes Other: 1.)The design pressure in this application relates to Evaluation Reports one particular assembly over concrete deck. Refer to the ER FL10497 R5 AE 2015 12 FINAL ER MULE-HIDE FL10497- Appendix for other systems and deck types,2.)Refer to ER, R5.Ddf Section 5 for other Limits of Use. Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department.with an email address which can be made available to the pu61Tc To determine If you are a licensee under Cfiapter 455,F.S.,please dick ere. Product Approval Accepts: M RPM Credit.Cdi d_ ' k, .y�.Sid ': QOTPJNIIYIERD 'APPENpUt1:;ATrA AMENTREQUM64ENMFORWIND,;UPUFi{RESISTANCE, Table: D¢ck. Application r Type Descriptioit 11, 1A, Wood New.OrReroof'(Tear--off) A=1 Sonded?lnsulatian,.Bonded:Roo€Cover 3 1871 Wood New=or Reroof,(Tear-0f1 A 2' _ Mech-:AttadieitrAnchar Sheet,Bofitledjlnsulation Bortded Roof Cover 113-2 W.00ii New;;Reroof,(Tear Off),ar Recover A=2 Md ;Attached-Arc iorSheet.Bond"ed+Insulation Boniied�Roof'Cover S IC Wood New;;Reroof(Tear-Off)�gr Recover 6,.. Mech:Attacfred;ti►sulatFon;'Bontletl Roof Cover 6 1p 1Nood New;Reroof(Tear Off)a r;_Recover D PreU►n Attathed}lnsulation,[uSech 1LCacthedrBase Sheet BondedxRo'of Cos!er :...,_ 3E=1 1Nood New or Reroof(TeaKOff)- E Non=lnsulated,,,Mech Attached Base Sheet:(nails) Bonded Roof.Cover g Gyooi New "cover B1E2 AgrofarOor ase Sheet(screws&plates),Bondiwi!'Roof CoWrr 9 1F . wood Newpr Reroofi(Tear,Offl f Non=lnsulated,•Bonded.Roof Caver 2A. Steel orConc. New;Reroof:Tear-0 9 ( ff),or Recover C. Mech.Attached Insulation,;Bonded.Roof Cover_ 3p 28 Steel orConc., New':Reroof(Tear Off►,or.Recover _ D Prelim AttachedllnsuWtion,llAech Attached Base Sheet,;BondedtRoof Cover 3A-1 Concrete Newior Reroof'(tearOffij_ _ A4 BondedJnsuletioh,Bonded-.Roof Cover 3A-2 Concrete.. Newor Reroof'+ear 0. ff)._ _ - ..__ A-1, Bonded Temporary Roof Bonded lnsu4atwn,,BondedRoofCover_ 1$�14 15 3B Concrete Newior Reroof(Tear Off),. F Non-Insulated,Bonded-Roo#Cover 15 __ 4A LWIE Newror Reroof(TearOff) Al BontledansulationBonded.Roof Cover 36-17 48 tiN(C New or Reroof_(Tear Off) A-2 Mech::Attaehed Anchor'Sheet,Banded L6nwlation,8onded:Roof Cover 17- 4C WIC NeworReroof,(Tear Ofn E Non+lnsulateil;_Ntech.AttachL!d-Ba"e.Sheet,-B(? ed•Roof,'Cover tg 5A CWF New or Reroof(TearOfQ A4 Bonde&lnsulation;Bonded-Roof Cover 26 513 CWF New;,Reroof:(Tear-Off)or Recover Ae2• Mech-,Attached:Anchor,Sheet,Bonded4nsulation,13bnded Roof.Cover 20 5C CWF New_or Reroof(Tear-Off) E Non=lnsulatedi•Mech.,AMehedBaseShee%:Bo(Oed.Roof'Cover 20 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded;ROof Ever 23 - _ 68. GypsuM Reroof(Tear-0ff) E Non-lnsulated,_Medi.Attached.Base Sheet,:8onded-Roof.Cover 22 7A Various Ree9ver' A4 Bonded;Insula. . tion,.eandetl RooECover 22:23 The followina:notes apply to the systems•outlined herein: I. The roof.system evaluation herein pertains to above-deck roof components. Roof-decks and.structural-members shall-be•in:accordance with FBC requirements-to the satisfaction•of the:AW, Load+resistance-of the roof deck shallibe documented through proper codified and/or FBC Approval documentation. 2. Insulation,/base sheetfasteners shall be of sufficient length for the following deck:engagement: ➢Wood: Minimum 0.75;,inch penetration. ➢Steel: Minimum:0.75.inch penetration and engage the top flute-of the:steel-deck. ➢Concrete: Minimum.1-inch embedment:into pilot holedn.accordance with fastener manufacturers pubUshed:instailation-instructions, 3. Unless otherwise noted;.insulation may be any one layer or combination o-polyisoc, nurate,polystyrene,•wood-fiberboard, perUte,gypsum-based roof board or mineca!wool roof board that meets the tJ/1 requirements ofF:A:C,Rule 61G20 3andis-documented•as meeting FBC25053 ap_d,for foam:plastic,'FBC Chapter26;•wherninstalled with+thetroof cover. 4. Minimum Z00'ps1,minimum 2-inch thick.lightweight�insulating:concrete maybe substituted forrigid,-insulatiomboard-forSystem•Type D(mechanically attached base sbee't;Wn'8ed=roof coWr ),,'*htreloyAfre-tiase sheet fasteners:are installed through the IWlC to=engage the structwral;steel-orconcrete<deck. lb'erttru-ctui l� ditk,shaU'tie-of egtiaAorgr.eotet-corifituratibn�tosthe-,steel;and dbnd.,de:deck�ii's'ti ftg L Roottedm and structural members shallibe,ln•aecordance with FBClrequirements,tothe.satisfaction ofthe AHJ. load resistance,of the:=roohdeck,shallUyddcutneiitedithrou hi ro• rcodifWd g p Pe atrd/..ai%FBCrAoo�.oatil doarinetitition. ExterlorResearchand!Design,LLC.d/b/a Trinity IERD EvaluaUont eport•M10000A3:08-RS=ferFUD:497-R5 Certificate of Authorization#9503 Revlsion.5:12/14/2015 Prepared:by RobertNieminen,PE 59166 APpeiid X-:4 Page rdf23 QOTRINIWIE.RD S. Unless otherwise noted,insulation adhesive:ap;Oicationrates areas follows. Ribbon or bead widfhis at the of-application;the:ribbons/beads shal4expand asnoted!in'.thetmanub&"ees:published inctrucUons ➢Hot,aspha►t: Full coverage at 25-30 lbs/square. ,a ➢Dow lnsta4tik Roofing.Adhesive(134S): Continuous;0:75 to.1-inchwide ribbons,1 inch o.c. ➢.tidWenniumOneStep:Foamable Adlfesive(M-OSFA): Continuous'0-25 to OS-Inch wideribbons,•124ndt:o.c. ➢.DMG:OIyBond 500(08500): Continuous.0:75-to i-inch,wlde tibbons,12-inch•o.c.(P.bceC3ttor SpW6hot). Note:OlyBand,Green-moyhe used where O1yBand'50D.&referenced ➢OlyBond;Classic(OB Classic): Full coverage:at 1 gal/square. ➢3.M:CR-20: Continuous2S=3 S-in&wide ribbons 12-inch o.c ➢Note: When:multiplelayers(s):afinsulatlon:and/orcoverboardareinstalledln:ribbon-appged.adhesive,boardlalntsshall be staggered. ➢Note: The.maximum edge distance from the:adhesive ribbon:to:the edge gf the lnsula'tion:boardshall'be not'less-than:one=half thespecjftedrlbbonsspacing. 6. Unless.otherwise noted,:alljinsulations are flat stock or taper board-of the minimum-thickness:noted. Tapered polyisocyanurate at-the following thickness limitations maybe substituted.with�the followlna,MM dmtun } Design:Pressure(MDP):Ilmltatlons.lnno.case shall these values:be used to:increase tho`MDP•listingslin'the;tables,-rrtherif:MDP Iistingtelow meets or exceeds that listed'fora pardtular sy5teman•ttieaaWes,then the thinner board listed below maybe used asa drop=lnforthe equivalent thicker material listed.in:the table:. Millennium One Step�Foamable Adhesive•.(M=OSFA): MDP -157 5;psf (Min.0:5-Inch-thick) IOMGZ.OIyBond 500(08500): MDP 45.0:psf (Min.05-1nch•thick-MultiWax FA-3) ➢OMG..OIyBond,500(08500): MDP -187S;psf (Min.0S=lnch•thick:1S0;95+GL) ➢OMGtOlyBond.500(OB500)i MDP -315.0'psf (Min.0.5=inch•thick ENRGY 3) ➢.OMGAIyeond500(08500): MDP a187.5psf (Min.0.5-lnch thick ACFoamll,Poly ISO 2) ➢3M CR-20: MDP -1175 psf (Mim 1.0=lnch,thick) C�8Bonded.polyisocyanurate insulation.boards-shall be maximum 4 x•4 ft. Fa 6m0chanIcaIly attached_components'or partially-bondedj nsulationT_tW,maximum'design pressur_esfar the-eIected_assembly-'shall meet or exceedthe 2one desigWpressureldetermInedan--accord ance with;F.BC . Chapter_36,_and__Zones:2_and;3_sliall_ernpioyanrattachment_density=designed-�by_a--qualifleddesign:professional:.to resist_the elevated;pressure_criteria:':'Commonly,used mettiods--are RAS'117 and'F,M:LP_DS°1=29: Assem6ltes markeif with an:asterisky carry the Itmitattons set forth in_Section 2 2,1;5_1(a)_of;FIVhLPDS_3�29_forZone 2.3 enhancements; 9 For fully+bondedassembltes,the maximum-designpressurefor the selected assembly shall:meet orexceed•critical:designpressure:determined Inaccordance with.FBC Chapter 16,aridinc�rational;201ysts,ls:pennitted- 10. For:Median I call y attached"components:over.-existing d ec ks7,fasteners 9 h-a 115 Wtestedan the ez(sting-deck,for,withdrawaI-resIstancb. A.qualified--design-professIa rig I-shaILreview;.the=datalorcom parison'wthe minlmurfi requlremenu forthesysst'em Testing an`d analysls'shalljg.in accordance with TA5N105 or'ANSI/SPRI FO 1-1. For existing;substrates in:a bondedrecoverinstallation,the existing roofsystem shall.be examined.for compatibilityand bondiperfonnance•with,the•selected adhesive,aWa the extstingzroofsystemshaiiibe caps w:of resisting,project;design:pressuresiomits own meritto the satkfacticn.of the AliJ,as!documentedthmugh;fleid;upiift'•testing;in:accord"ancewithASTMt907 PMILPDS,lS2,:ANSI/gPklilA=16rTAS, 24. 12. For.Recover Applications using System T,ype:D,the insulation is:optional7 however„the existing-roof system shalllbesuitabie for a recoverapplication. 13. WIC shall be cast4h,accordance with+BC Section.191-7 tothe satisfaction.of the.Aathority Having4utisdietion. Fotsystems.where spedfle LWICas:referenced,:refer-to:current LWIC:P.roduCCApprovaliferspedf eideck �- construction:atid lirimitations. F.orsysterns where spedfic�LWICds not=teferenceii,the-minirimum,design,mix shall;be 300cpsL In:alltcases tftetminimumttbp;rroat+ttitcknesssis,24ndus. Fot�IWlC-dveraitnktrrtai�concrei2, reference°ls.madeto FBC Section 1917:41,Point.1. Exterior Research,and;Design,LLGd/b/aTrinitylERD EvaluationtReport:M10000:03,"& forFL10497-RS Certificate of Authorizationft9503 Rewision5:13/14/20L5 Preparedby: Rmbet'Nierninen;,PE-59166 Apperid1*4,fte 2W 23 QOTRINITYIERD 14. Unless otherwise noted,refer to the;.following references for bonded•base,ply_or cep sheet;appllcations. 1i►eLe is Mule-HBERooF COVERS' _ Reference Uyer_ Material- -Base ply, One or,more plies SA•."Sheey;SA Brie Sheet:Fft): SBS-SA- P SA=SBS CapSheet SA SBS_Cap Sheet,{FR)__ l Stlf:Adbdit (SBS,:Self-Adhering) No te:• ,Self adherlgg memtrranes steal!notrtre'JnstoUed overAPP-IAmsmbrones APP TA Base Plyor Piy One or,more.pltesAPP Torch"Base,.APP Torth'S Tom. (APP TorchrApplietl). Cap APP Torch S,APP TorchGy_APP Torch G FR,APp Torch•,KootCap G;rkPP TorchKaofCapIG+FR__. _ .. .___._ _. _.. ._._ .. _.. APP-SA Cap SA:A.PP Cap Sheet SA.APP Cap Sheet{FR)SA--APP KoolCap G SA-APe�1560 Cap G(FR),. SelfeAdhe irig (APP,Se1f-Adhering) Note:., Self-adheringmembranesshollnot'btinstolitdovOAPP,TWTe! tunes. 15. Any FBC Approvedacoating,listed;forusewith SBS,or APP modified bitumen400fing may:be.appiled to:the:topsroof+meriibrane without advers2'effect on,the system Wiird:bad:performance. Refer to currenvRooflng Materials Directory for-,flre ratings associated with coatigg.usage. 16. The foilowingrepresent,priming;requirements:forgypsum=based coverboards: Y D,ens0eekand Dens:Deck Prime;shall.be field=primedwlth.MulesHide 1.21 prior to,seifadhering ortorch�applied membrane application. A SECURO.CK;Gypsuw.FiberRoof Board does nottegwire field,priming4dranyimemlir2ne application. 17. 'MOP'=Maximum Design-Pressure isthe result of testing'forwindYoad resistance-based omallowable-windeloads.Refer totFBC 1609;fordeterminaUonofdesign°wind:loads. TAj3L. __L WOODDetO-NEWICDNSTRUETION�oR-REROOF((TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck, Base Insulation-Layer { Tbp:kwWation:Layer Reot:Covcr(SeerTabk•3')' FW No. (SeeNote 1) ry,pe Attach Type Attach Base.P.ly PIY C..0 ( ) ',SELP%ADHERNO.BASE PLtwnR,BASEM=to WANDgPnoNA TOP,INSULA'hGN;ojTHESAM¢:T'Pfc:; • Min.fiS/32- min;;15InchACFoamIl ACFoam=111,ENRGX-3,H- DIS M-0SFA,. `(Optional):add[tio�rai DIS.M=OSFA, _ SBSS7I, P1SA; W-1 inch plywood Sh1eId,:H-Shield CG,iNlulti"Max:FA3 OBSOO&CR-20 (ayers(s)`of base!insulation OBS00 or CR=20 �P'fiA j P=TA •52'S . _. . __.__. .. . _ _ _... _. _. SBS•SA (Optxx�at);SBS.SA AP � i Exterior Research:and Design,LLC:d/b/a Trinity.)ERD Evaluatlon,Report M10000:03A$RS for:FUD497;RS Certificate of puthoruadon.#9503 kevision'•5:-12/14/30TS Prepared`.by: Robert Nleminen;RE-59166 Appendix 1.Page lof>33 Q0TRJN1-rYj:ERD . TABLESE-1:WOOD,DECKS�—NEW!CONSTRUE.TIONioa;REROOF'(TEWOFl): SYSTEM TYPE:E:NON-INSULATED;MECHANICALLYATTACHED BASE SHEET(NAus),BONDED ROOF COVER - _ BaseSheet _ _ RoofCowr:(SwTiiblia) System. Deck(See IufFiw;(piiq' No. Note.1) Base, Fasten Attach ToRaYArruto;Br►sEPtlrs: - . - , ;' � ' - MIn.15/32- 9-Inch o:c:at 2-inchilap�and B-inch:o:a intwo,(2), O tlon5l APP=TA APP=TA -45 0• W-19 NaiWase :. SlmplexMAWCap ( :P ) inch p(ywood equally spaced,!staggered center rows Mln."15/33- 94nch o,c at 2 inchap and 1271nch_o:cin two(2),W-20 NalhBase Simplex MAXX•CaP - rows (OPtionSl)APP-TA APR=TA -535 inchplywood a B $ cedsggercd center Min.:15/32- -Original SimplexCap+Malls.(1-fnclt.metd1 heo0:dit7n?&ter, 6-Inch o:c at 3-inch,Ib :and:6dncho a in four44), (Optional):—PP—TA ARP-TA -525 W-21 inch plywood APP Torch-Base,NalWase 31 ou e 9 . a a.11 _s aced,staBgeridcenterrowsshank Nail Base,-Polyglass,G2 Base;. W-� Min.S9/32= CertainTeed�Glazbasei Firestone 32 ga:,1 5/8=inchtdiameter.tin.caps wrtltil`ge.;annular, &inch o:c'in 4 inchJap antl 8iinch o C'iinzthree:(3; Inch;plywood .NI8:8ase,lM.Perma-P-N>28;Tamko nng'shank7nalis equaliy_spaced,:staggered center_rows (m P`TA s4RP 7A 60:0 Glass:8ase or GAFGLAS#75 W-23 Min.15/32- Polyglass G2 Base,Nail Base 32 ga.,1-5/8-lnch•diameter t1n,caps.with.11,ga.-annular 8-Inch o.ain -Inch lap;and;84nch;o.c.In•fouri(4), (Optional)APP-TA APP-TA -67.5 Inch plywood ringshank:nalls equally spaced,:staggered center rows Min.15/32- 10=mch o:c.in 4anch lap4nd.10-inch•o.e.inthree tlonal)A P-TA ARP=TA -75:0 W 24 inchp O;:lywood Polyglas&G2 Base,Nall Base Simplex MAXX Cap eq .uall ysPaced;:staggere (O A 3 d:center�rows Min.15/32 94nch o.ca in 4-Inch lap and:9-inch o:a In four 14)' tiona :APP=TA AP,P-TA -90i0 W-25 Polyglass.G2 Base,Nag Base Simplex MAXX Cap (Go Inch,plywood equagyspaced,staggered center rows MIn.15/32 NaI1:Baze Simplex MAXX Cap 6-inch o.e.at 24nch lap and•6-inch,o:c in•two,(2), W-26 Ineh,plywood equally spaced,.staggered center rows (Optlonal):APP4A APO-TA -90i0 _. V1127 Min.1 Elastobase Slmplex•MAXX{ap (Optional).5/32- 6-Inch o.c.at 2-inch4ap and 6-Inch:o:c.in,three:(3), 0 AP.P TA APP TA -1010 ) Ineh.plywood _-. .._- - _. _ . . - _ _...,equallyspacedstaggercdreenterrows Vi1.4 Inch-plywood Elastobaze or Elastobaze Poly ngshank/nallsc dmeterUn,caps.wlth-li.ga.amular equally spaced staggered eente rows m fouP(4) (Optional)APP-TA APP-TA -113 5 J Min.15/32- Original Simpiex.Cap Nails.(.14nch:metdihead,diameter, 6 inch o.e at 3-inchdap.aniJ.6 lnch:o:c in#our, SBS SA,APP- 1N-29 Ndil:Base, (Optloml)SB5-SA -525 inch+piywood 31 gauge,xmin:1251rtcNrbng anaular,groogedislwnkJ equally'spaced,Staggered center rows SA,7WP TA Min.19/32- 32 ga,.1-5/8-Inch diameter tin:caps:with 11 ga.annular 8=inch o:c in 4-inch•lap and�85inch.o.c.in'•three; SBS+SA,ARP- W-30 Nail Base (Optional):585=SA -60i0 ineh.plywood ringshank:nails equallyspaeed,staggered center rows SA,;APP-TA MIn.19/32- 32 ga.,1.5/8-Inch diametertin:ca s withal a=annular 4-inch o.c.In 4-Inch.la and4einch.o: .In:four, (gptional)SBSeSA SBS*S,A. -OP- -975 W-31 NaiWase Inch plywood ring shank nails. egwallyapaced,_Ftaggered:centerrows SA}1PP TA Min.19/32- 32ga.,15/8itVch diameter tin,apswiUfllga.,annular 6anch,o:ain4-inch.l ap+and 6?ineh:au inrfour, O'fonal)5§5=SA �'A' P- -113 5 W 32 inch 19/32-3 NAII,Base dog'shanknails:dote TIncapsaretd,beprimed+with equally-spaced,.staggeredceriterrows ( Pt Sq,AOPTA Mule.'-tilde in- .ASTNLD41.primer, ExtedorResearch and:Design,LLC.d/b/a Trinity ERD Evalu2tion+RepoitM10000:03i0&R5`forFL10497-RS Certificate of Authorization 119903 hevlsionS':1Z/11/20t$ Prepared by: RobervNieminen,PE-S9266 A pperdixa'Paga It of 33