Loading...
HomeMy WebLinkAboutNotice of AcceptanceIF& Copy MAR 2 7 2017 PERMITTING MI14MI- St. Lucie County, FL MIAMI-DADE COUNTY DtADP • PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA),-I-IESE PLANS AND A►.L PRUPOSEO WOE Kwww. iamidade.eov/economy Interwrap, Inc. . ARE SUBJECT TO ANY CORRECTIONS 32923 Mission Way HEMMED BY FIELD INSPECTORS THAT Mission, BC, Canada V2V-6E4 MA OE SCOPE• This NOA is being issued under the applicable rules'andtegulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Titanium® UDL-30 / Titanium® PSU-30, Titanium® UD1-25 PLUS / Titanium® PSU-30, and UDL-MD (2 ply) / Titanium® PSU-30 Underlayment System LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 13-0730.01 and consists of pages I through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0603.19 MIAMI•DADE COUNTY �� 03 Ott,-) �( Expiration Date: 01/26/22 ''' • • T. LT CIE COUIi'TY B1J1T Pr,.TC_�_ ION Approval Date: 02/02/17 ?2�;V TWED iF0R R1N!P ,L-VNCE RFIV :1I� ;3�%'` f••Lt�� Page l of 7 DATE S -•1 / l FLANS AID PERMIT MUST BE KEPT ON J0113 On NO INSPECTION WILL ;aE &WEL ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: Polypropylene TRADE NAMES OF PRODUCTS MANUFACTURED BY APPLICANT TABLE 1 Product Dimensions Test Product Specification Description Titanium® UDL-25 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with one PLUS Type I & II side coated with UV protected and slip resistant Manufacturing Location #1& #2 UDL-MD (2P1y system) Manufacturing Location #2 Titanium® UDL-30 Manufacturing Location #1& #2 Titanium® PSU-30 Manufacturing Location #3 polymer stabilized polypropylene on both sides. 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with a Type I & H chemical slip resistant and UV protected coating on both sides. 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with two Type I & H sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. 36" x 72' rolls TAS 103 Unreinforced polymer modified bitumen material adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. MANUFACTURING LOCATIONS: 1. MLl 2. ML3 3. ML4 NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/Q2/17 Page 2'of 7 EVIDENCE SUBMITTED: TestAgency Intertek Testing Services Trinity I ERD Test Identifier Test Name/Report #3031783 TAS 104 3124826-01 ASTM E108 3119607COQ-003B ICC-ES AC48 3130639COQ-002A ASTM D226 3124826MID-007 ASTM E108 3146738COQ-003B ASTM D 1876/ TAS 117 3146738COQ-003A ASTM D226 135520.06.11 TAS 103 / TAS 104 I35520.06.11 TAS 103 / TAS 104 138010.08.11 ASTM D226 135520.08.11-1 TAS 114 I35520.08.11 ASTM D2523 / D1781 I44970.07.13-R1 ASTM D226, ASTM D1876 and TAS 114(C) Date 02/19/03 02/19/08 02/20/08 02/20/08 02/25/08 03/28/08 04/22/08 06/15/11 06/15/11 08/11/11 08/12/11 08/17/11 09/09/13 NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 3;of 7 APPROVED TITANIUM UNDERLAYMENT SYSTEM ASSEMBLIES: Deck Type 1: Wood Deck Description; 19/32" or greater plywood or wood plank System E(1): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. Base sheet: One or more plies of Titanium® UDL-25 PLUS or Titanium® UDL-30 applied with minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as noted. below. Note: Titanium® UDL-30 shall be inverted to provide a smooth bonding surface. Primer is not required when Titanium® UDL-30 is installed inverted (printed side facing down) Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three,. equally spaced, staggered rows in the field of the sheet. Primer: Metal/Tin caps shall be primed with ASTM D41 primer Ply Sheet: (Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. _ Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH460 and Dow TILE BOND Roof Tile Adhesive: . NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/62/17 Page 4 of 7 Deck Type 1: Wood Deck Description: 19/32' or greater plywood or wood plank System E (2): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. Base sheet: One or more plies. Titanium® UDL-30 applied with minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as noted below. Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. Primer: Titanium® UDL-30 shall be primed on the printed side with ASTM D41 primer, prior to placement -of cap sheet. Ply Sheet: (Optional) Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile' foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies, Note: For tide roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For foam=on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow TILE BOND Roof Tile Adhesive: NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 5 of 7 Deck Type 1: Wood Deck Description: 19/32' or greater plywood or wood plank System E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. . All General and System Limitations shall apply. Base sheet: One or more plies of UDL-MD (2Ply system) applied with minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as noted below. Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. Ply Sheet: (Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the first course of Titanium® PSU-30 parallel to -the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the file manufacturer's NOA. For foam -on file roof assemblies, approved use with ICE Adhesives Polyset AH-160 and Dow TILE BOND Roof Tile Adhesive. NOA No.: 14-0603.19 ' MIAMI-DAD, COUNTY Expiration Date: 01/26/22 Approval Date: 02/92/17 Page 6 of 7 BUILDING PERMIT REQUIREMENTS Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Titanium Synthetic Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30 / Titanium® PSU-30, UDL-MD (2P1y system) / Titanium® PSU-30 two-ply underlayment system, may be used in asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. 5. The standard maximum roof pitch for the Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30 / Titanium® PSU-30, UDL-MD (2Ply system) / Titanium® PSU-30 two-ply underlayment system shall be 5:12 for flat tiles and 6:12 on profiled tiles with lugs. For flat tile applications at slopes exceeding 5:12, flat tiles shall be staged 2 base tiles perpendicular to slope behind a mechanically attached batten or toe board with maximum 7 tiles high on the slope atop base tiles (Total of stack not to exceed 9 tiles). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. 6. Titanium Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system. 7. Titanium® UDL-30 / Titanium& PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30, UDL-MD (2Ply system) / Titanium® PSU-30 two-ply underlayment system shall not be left, exposed as a temporary roof for longer than 90 days of application. 8. Titanium Synthetic Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing System Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 9. Titanium Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If Titanium Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.: 14-0603.19 Expiration Date: 01/26/22 Approval Date: 02/02/17 Page 7 of 7 . _ ��. .� k, ; v_ � .. .. rt ._ .. it .. '7. ., $� {` .. ., .. _ - '" 12/14/2016 Florida Building Code Online Ls A0 9i BCIS Home Log In I User Registration Hot Topic Submit Surcharge Stats & Fads I Publications FBC Staff I BCIS Site Map I Links Search Florida K00% ��1333 or °.'� Product Approval (.� USER: Puse blic Ur +� File COPL1 qqyy EIP.crNJAr��FLim Product Approval Menu > Product or Application Search > Application List pis q7� Search Criteria Refine Search Code Version 2014 FL# 14645.3 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL FL# Type Manufacturer Validated Status By FL14645- Revision Metal Sales Manufacturing Corporation, FL#: FL14645.3 Yoosef Lavi, P.E. Approved R2 History Model:5V-Crimp Description: Min. 26 ga., 24" wide through fastened roof panel over min. 19/32" (214) 340-0049 thick plywood deck with fasteners through panel rib. Category: Roofing Subcategory: Metal Roofing ;Approves oy urtrlk. Approvals Dy Ursrrc snap De reviewea ano ranneu oy me tvi- ano/or me tommisslon a necessary. Contact us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in'response to a public records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: 1 R_*_1 e—Clsct W CreditCard Saf securitym F•rRres hops://www.floridabuildirig.orgtpr/pr_ppp Ist.aspx 1/1 EVALUATION REPORT OF METAL_ SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA-PRODUCT APPROVAL FL 14645.3-R2 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 31 Street, Suite 200 Louisville, KY 40202 Telephone: (502) 8554300 Fax: (502) 8554290 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer ##62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation. Report (3 Pages including cover) Installation Details (1 Page) Report No. C2010-3 Date: 3.27.15 `01111a1n1#111 No 62'240 =-0 gyp.• STATE OF kl� 'O 3.3cr .20t!�,- FL 14645.3-R2 C2010-3 3.27.15 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and @ 4" o.c. at edges New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 . Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. . Refer to FBC 2014 Section 1505 and current � U� FL 14645.3-R2 C2010-3 3.27.15 Page 3 of 3 approved roofing materials directory or ASTM E108/JL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/l/09 EXISTING SHINGLES (OPTIONAL) NEW UNDERLAYMENT - (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) SEE DETAIL 2 SEE DETAIL 1 NEW URED ONLY FO R �� (PANEL OVERLAP) NEW CONSTRUCTION) EXISTING UNDERLAYMENT (OPTIONAL) MINIMUM ATTACHMENT: 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS SPACED ® 6" O.C. IN THE FIELD & FASTENER AT PANEL FLAT REQUIRED FOR PANEL ENDS ONLY. MIN. 2X- WOOD RAFTER/JOIST/--/ 4" O.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X-SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. �— PLYWOOD DETAIL 1 19/32" THICK (MIN.) #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. PLYWOOD DETAIL 2 19/32" THICK (MIN.) PANEL FASTENER PER ALLOWABLE PRESSURE TABLE ON THIS SHEET. 5V-CRIMP ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 36 41.6 16 74.8 8 196.75 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. d U Cf U' WN z ro N�o lai V7y N W to ro J aD N Noto 05 un Ln 1 OF 1