HomeMy WebLinkAbout12-14-2020 Dorothea Ufner-Final12/22/2020 E-1 1 OF 3GENERATORADDITION RISERDIAGRAMNEW GENERATOR FOR:DOROTHEA UFNER9409 POINCIANA CT.FORT PIERCE, FL. 34951LOAD MANAGEMENT "LCM" LOAD SHED LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). GENERAL NOTES: ·THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. ·THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). ·ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. ·THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. ·PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. ·ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. ·GROUNDING PER NEC ARTICLE 250. ·STANDBY SYSTEM INSTALLATION PER NEC ARTICLE 702, AND MANUFACTURER INSTALLATION INSTRUCTIONS. NTS 1 GENERATOR ADDITION RISER DIAGRAM DATEREVISIONMARKDATE: SHEET DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911SCOPE OF WORK: ·HOMEOWNER TO HAVE EXISTING TELE/COMM BOX RELOCATED TO MAKE ROOM FOR NEW ATS. ·INSTALL 200AMP SE RATED ATS NEXT TO UTILITY METER CAN ON EXTERIOR WALL. ·RE-FEED INTERIOR PANEL FROM NEW ATS. SEPARATE NEUTRALS AND GROUNDS IN PANEL IF REQUIRED. ·INSTALL COLD WATER BOND FROM ATS TO NEAREST CU WATER PIPING. ·UTILIZE A PRE-FABRICATED GENERATOR PAD. ·PROVIDE AND INSTALL (1) 22kW GENERAC GENERATOR. ·PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FROM ATS TO GENERATOR. ·PROVIDE (2) LOAD SHED DEVICES PER SIZING DATA THIS SHEET. ·NEW LP TANK TO BE PROVIDED AND INSTALLED BY FERRELLGAS UNDER A SEPARATE PERMIT. ·NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK. GENERAL NOTES: 1. 2. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. ELECTRICAL LEGEND: SURFACE MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD FLUSH MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD SURFACE MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD FLUSH MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD UTILITY METER CAN OR METER/MAIN COMBO UNIT GENERATOR AND GENERATOR PAD GAS STORAGE TANK SURFACE MOUNT AUTOMATIC TRANSFER SWITCH NON-FUSED DISCONNECT FUSED DISCONNECT 30AR NF 3R FRAME SIZE NEMA RATING NON FUSED 30AR 30AF 3R FRAME SIZE NEMA RATING FUSE SIZE CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION EXISTING 2"PVC UNDERGROUND SERVICE FEEDER EXISTING OVERHEAD SERVICE RISER, WEATHERHEAD, AND UTILITY FEEDERS EXISTING 1/2"PVC W/ (1) #4 BARE CU 2"PVC W/ (3) #4/0 THWN AL 2"PVC SLEEVE W/ #4/0 SER AL CABLE 1-1/4"PVC SLEEVE W/ GENERAC CABLE W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND, (5) #14THHN CU #4/0 SER AL CABLE 3/4"PVC W/ (7) #14 THHN CU 1/2"PVC W/ (1) #4 BARE CU A B C D E F G H I POINT OF NEW CONNECTION AC ALTERNATING CURRENT A/C AIR CONDITIONING AFG ABOVE FINISHED GRADE AL ALUMINUM (CONDUCTOR) AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE C CONDUIT CU COPPER (CONDUCTOR) COVB CITY OF VERO BEACH DC DIRECT CURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER & LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER IRC INDIAN RIVER COUNTY KVA KILOVOLT AMPERE KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANELBOARD MTS MANUAL TRANSFER SWITCH MSB MAIN SWITCHBOARD MLO MAIN LUGS ONLY NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NTS NOT TO SCALE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NON-SE NON SERVICE ENTRANCE RATED PLCS PLACES (QUANTITY) PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT RMC RIGID METAL CONDUIT RTU ROOF TOP UNIT SE SERVICE ENTRANCE RATED TYP TYPICAL TEMP TEMPORARY TRANS, TX TRANSFORMER UG UNDERGROUND UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERE W WATT XFMR TRANSFORMER ABBREVIATIONS: NATURAL GAS METER NOTE: NOT ALL CONDUIT AND WIRE SHOWN ON THIS SCHEDULE MAY PERTAIN TO THIS PROJECT. (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) GROUND ROD EXISTING 200 AMP METER CAN 120/240 1Ø NEW 200 AMP GENERAC SE RATED ATS 100AMP BREAKER EXISTING (2) 5/8" X 8' CU GROUND RODS NEW GENERATOR: AIR COOLED GENERAC 22KW GRADE ATTICATTIC GRADE D EXISTING WATER LINE INTERIOREXTERIOR INTERIOREXTERIOR EXTERIORINTERIOR EXTERIORINTERIOR FINISHED FLOOR CA EXISTING 200 AMP PANEL EXISTING PANEL IS BACK TO BACK FROM EXISTING METER CAN IF E G E F:\Generator Drawings\12-14-2020 Dorothea Ufner\12-14-2020 Dorothea Ufner.dwg, 12/22/2020 8:39:00 AM POINCIANA COURT CL WINDOW EXISTING PANEL EXISTING UTILITY METER NEW ATS 10'-0" 10'-0" 5'-0" 2'-0" NEW GENERATOR AND PAD NEW 500 GAL. LP TANK (BY OTHERS) SINGLE FAMILY RESIDENCE 9409 POINCIANA CT. FORT PIERCE, FL. 34951 SCREENED POOL ENCLOSURE DRIVEWAY GARAGE 10.0' UTILITY & DRAINAGE EASEMENT PROPERTY LINE 50.00' 10.0' UTILITY EASEMENT PROPERTY LINE 50.00'PROPERTY LINE 150.89'PROPERTY LINE 150.89'12/22/2020 2 OF 3GENERATORSITE PLANDATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 00019111" = 10'-0" 1 GENERATOR SITE PLAN DATEREVISIONMARKDATE: SHEET N W S E E-2 0'2.5'5'10'20' SCALE: 1" = 10'-0"NEW GENERATOR FOR:DOROTHEA UFNER9409 POINCIANA CT.FORT PIERCE, FL. 34951F:\Generator Drawings\12-14-2020 Dorothea Ufner\12-14-2020 Dorothea Ufner.dwg, 12/22/2020 8:39:19 AM 12/22/2020 3 OF 3 DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911DATEREVISIONMARKDATE: SHEET E-3PRE-FABRICATEDGENERATORPAD DETAILNO SCALE 1 PRE-FABRICATED GENERATOR PAD DETAIL NEW GENERATOR FOR:DOROTHEA UFNER9409 POINCIANA CT.FORT PIERCE, FL. 34951F:\Generator Drawings\12-14-2020 Dorothea Ufner\12-14-2020 Dorothea Ufner.dwg, 12/22/2020 8:39:30 AM