Loading...
HomeMy WebLinkAbout12.31.20 Revision Design Pressure Report Property Information Building Information Owner: Brown Wind Zone: 160 MPH. Address: 152 Calle de Lagos Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 26 38 7 32.5 -35.2 2 Int 52 55 7 31.0 -33.8 3 Int 52 55 7 31.0 -33.8 4 End 108 83 7 28.6 -35.8 5 End 108 83 7 28.6 -35.8 6 Int 108 83 7 28.6 -31.4 7 End 74 62 7 30.0 -38.6 8 Int 26 38 7 32.5 -35.2 9 Int 37 62 7 31.5 -34.2 10 Int 37 62 7 31.5 -34.2 11 Int 26 38 7 32.5 -35.2 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1