Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's Page 1 Residential Heat Loss and-Heat Gain Calculation 10/24/2017e2a' ) In accordance with ACCA Manual J Report Prepared By: R C E I�V9 E Central Air Systems Inc. _ OCT 2 5 201d For: Kyes 99 Nettles Blvd PERMITTING St. Lucie County, FLJensen Beach, fl Design Conditions: Fort Pierce Indoor: Outdoor: Summer temperature: 70 Summer temperature: 90 Winter temperature: 70 Winter temperature: 42 Relative humidity: 55 Summer grains of moisture: 127 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH)' . Duct 2,116 0 2,116 938 Floors 497 0 497 893 Walls 1,085 0 1,085 1,287 Ceilings 11781 0 1,781 1,133 People 1,500 1,150 2,650 0 Fireplaces 0 0 0 0 Misc 1,200 0 1,200 0 Windows 4,023 0 4,023 1,462 Doors 529 0 529 628 Glassdoors 2,592 0 2,592 964 Skylights 0 0 0 0 Infiltration 899 1,862 2,761 3,010 Whole House 16,222 3,012 19,234 10,315 ( 1.5tons ) _ Y' F ILF 1« HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences.