Loading...
HomeMy WebLinkAboutE-1GENERAL ELECTRICAL NOTESUNDER SEPARATE PERMIT.ALARM SYSTEM BY ALARM CONTRACTORALARM NOTE:ELECTRICAL LEGENDTHE USE OF "ROMEX" TYPE WIRE ISACCEPTABLE IF IT IS IN COMPLIANCE:,7+1(&7$%/(%)25ƒ&NOTES:ELECTRICAL RISER DIAGRAMN.T.S.7+((/(&75,&$/3$1(/&211(&7,2160867%(8//,67(')25ƒCONDUCTORS IN COMPLIANCE WITH NEC 110-14(c) "THE TEMPERATURE RATINGASSOCIATED WITH THE AMPACITY OF A CONDUCTOR SHALL BE SELECTED ANDCOORDINATED SO AS NOT TO EXCEED THE LOWEST TEMPERATURE RATING OFANY CONNECTED TERMINATION, CONDUCTOR, OR DEVICE."ALL 120-VOLT, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYINGOUTLETS OR DEVICES INSTALLED IN DWELLING UNIT IN FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, ROOMS,RECREATION ROOMS, CLOSETS, HALLWAYS, KITCHENS, LAUNDRY ROOMS ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULTCIRCUIT INTERRUPTER DEVICE OF THE COMBINATION TYPE AS REQUIRED BY2014 NEC 210-12(A).BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZEOF CKT. BKR. AND FEEDER WITH THE A/C MANUFACTURER'S REQUIREMENTSAND SHALL BE IN COMPLIANCE WITH NEC 424-3, 440-22 AND 440-32.*ALL 125-VOLT, 15A AND 20A, RECEPTACLES IN AREAS SPECIFIED IN NEC 210.52SHALL BE LISTED AS TAMPER RESISTANT RECEPTACLES AS REQUIRED BY2014 NEC 406.12.****OWNER: XX MATANZAS AVENUE FORT PIERCE, FL. 34946 JAMES & YAMILETH POZO 2200 SW 16th. TERRACE MIAMI, FL. 33145 PHONE: (954) 605-7153 ONE STORY RESIDENCE