HomeMy WebLinkAboutSpecs on heater from rheem RBHP-21J06SH2BRheem High Efficiency Air Handler FORM NO. H11-544 REV. 1 • Industry Standard R-410A Refrigerant Applications • Models featuring Electric Heat without Indoor Cooling Coil • Quiet and efficient X-13 (ECM) motor technology • Only 35" tall and 4-way convertible for all those tight spaces • Available from factory in upflow and horizontal configurations • Nominal airflow up to 0.5" external static pressure with reduced airflow up to 1.0" external static pressure • Factory installed MultiFlex ®coils • Sturdy steel construction with 1 inch [25.4 mm] of foil faced insulation for excellent sound and insulating characteristics • Permanent, easily accessible and washable filter furnished standard • Circuit breaker (standard on units with more than 11 kW) meets U.L. and cUL requirements for service disconnect • Factory installed auxiliary electric heat provides exact heat for indoor comfort over a variety of applications •Watt restrictors, standard on RBHP-17 models above 6 kW and on RBHP-21, RBHP-24 & RBHP-25 models above 11 kW, stage supplemental heat so that only the necessary amount is engaged to maintain comfort in the conditioned space • Fan settings for selectable, customized cooling airflow over a wide variety of applications Air Air Handlers RBHP Series RBHP- Series X-13 (ECM) Motor Efficiencies up to 16 SEER Air Table of Contents RBHP Series 2 TABLE OF CONTENTS Engineering Features ......................................................................................3 Model Number Identification ............................................................................4 Dimensional Data ............................................................................................5 Airflow Directional Data ..................................................................................6 Airflow Performance Data ............................................................................7-9 Electrical Data ..............................................................................................10 Electrical Wiring ............................................................................................11 Accessories ............................................................................................................11 Limited Warranty ..........................................................................................12 Air Engineering Features RBHP Series 3 Engineering Features RBHP- Series • Quiet, efficient X-13 (ECM) motor technology providing nomi- nal airflow to 0.5 inch [12 kPa] of external static pressure. • Field selectable airflow to meet the requirements of particular applications. • Low continuous fan speed. • The most compact unit design available. • Attractive pre-painted cabinet exterior. • Rugged steel cabinet construction, designed for added strength and versatility. • 1" foil faced insulation mechanically retained in blower compartment. • Four leg rubber insulated wire motor mount. • Circuit breakers standard on models above 11 kW and optional on models with 11 kW or less. • Models supplied with circuit breakers meet UL and cUL requirements as a service disconnect switch. • Provisions for field electrical connections from either side of air handler cabinet. • Tab lock blower housing with integrated electric heaters, controls, motor and blower. Slide out design for service and maintenance convenience. •Exclusive dependable Incoloy sheath type electric heating elements located in the blower housing provide mixed warm air. • Field convertible for vertical upflow, vertical downflow, hori- zontal left hand or right hand air supply. • Common combustible floor base accessory fits all model sizes when required for downflow installations on combus - tible floors. • Durable framed cleanable air filter provided as standard in unit filter rack. • MultiFlex ®indoor coil design provides low air side pressure drop, high performance and extremely compact size. All coils come with PVC condensate elbow standard. • All indoor coils have tinned copper tubing and aluminum fins. • Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. • Both supply and return duct flanges provided as standard on air handler cabinet. • Connection points for both high voltage and low voltage control wiring inside air handler cabinet. • Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [51 mm] for 11/2 inch [38 mm] conduit. • Patented watt restrictor on heat pump models to control electric heat during heating operation. • Internal checked TX valves are used on the RCHL indoor coil for more quiet refrigerant metering. • Front refrigerant and drain connections. [ ] Designates Metric Conversions Watt-restrictor BLOWER SECTION X-13 (ECM) MOTOR Supplemental heat, provided by electric heating elements may be necessary in some areas when heating requirements for indoor comfort exceed the capacity of the heat pump system. When supplemental heat is required, units with the Watt Restrictor will restrict the amount of supplemental electric heat that can be energized dependent on the heat output of the heat pump (temperature of the air leaving the indoor heat pump coil). The Watt-restrictor utilizes sensing devices in the unit to sense the air temperature leaving the indoor coil and disengage unnecessary heating elements when that temperature is at least 85°F [29°C]. (In this mode your system is controlled by the first stage of the wall ther- mostat.) This occurs only when the second stage of the wall thermostat calls for heat. Since the heat output of the heat pump is dependent upon the outdoor air temperature, this control performs the same function as a field installed outdoor thermostat. An additional benefit of the Watt Restrictor is that it can sense a degradation in heat pump performance due to causes other than outdoor temperature and react accordingly to bring on more supplemental electric heat. Coil Code Refrigerant Type 2 Cabinet Width R-410A 17 1 R-410A RCHL-24A2TH17 RCHL-36A1TH21 21 24 25 4 R-410A RCHL-48A1TH24 7 R-410A RCHL-60A1TH24 Air Model Number Identification RBHP Series 4 Model Number Identification J 00 N H D Coil Code A = No Coil Airflow Horizontal Multi-Position Control N = No Circuit Protection (Single Circuit) S = Circuit Breaker (Single Circuit) Electric Heat 00 = No Heat 14 = 14.0 kW 06 = 4.9 kW 18 = 17.5 kW 07 = 7.0 kW 21 = 21.0 kW 11 = 10.0 kW Voltage A = 115V-1-60 J = 208/240V-1-60 R B H P 17 Rheem Classification B = Blower Unit Application H = Air Handler Design Series P = X-13 (ECM) Motor Cabinet Size 17 = 17.5" [445 mm] 21 = 21.0" [534 mm] 24 = 24.5" [623 mm] 25 = 24.5" [623 mm] [ ] Designates Metric Conversions Available Models (Without Coil) RBHP-17J11SHA RBHP-21J14SHA RBHP-24J18SHA RBHP-25J21SHA Available Models featuring R-410A Refrigerant RBHP-17A00NH1 RBHP-17J06SH1 RBHP-17J07SH1 RBHP-17J11SH1 RBHP-21A00NH2 RBHP-21J06SH2 RBHP-21J07SH2 RBHP-21J11SH2 RBHP-24A00NH4 RBHP-24J06SH4 RBHP-24J07SH4 RBHP-24J11SH4 RBHP-24J18SH4 RBHP-25A00NH7 RBHP-25J11SH7 RBHP-25J18SH7 — 5 Air Dimensional Data RBHP Series [ ] Designates Metric Conversions Model Number Cabinet Size Unit Width “W” In. [mm] Supply Duct “A” In. [mm] Unit Weight/Shipping Weight (Lbs.) [kg] Unit With Coil (Max. kW) 17 171/2 [445]79/16 [192]92/99 [42/45] 21 21 [533]97/16 [240]109/117 [49/53] 24 241/2 [623]113/4 [298]125/134 [57/61] 25 241/2 [623]113/4 [298]125/134 [57/61]88/97 [40/44] Unit Without Coil (Max. kW) 66/75 [30/31] 79/87 [36/39] 88/97 [40/44] Unit Dimensions Unit Dimensions & Weights Air Airflow Directional Data RBHP Series 6 Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW NOTE:Coil and blower section are always in a draw through configuration. Air Airflow Performance Data RBHP Series 7 Airflow Performance Airflow performance data is based on cooling performance with a coil and filter in place.Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows oper- ation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For opti- mum blower performance, operate the unit in the .2" to .5" in. W.C. external static range. In general, the indoor motor speed tap should be as shown in table for the appropriate cooling capacity shown. Always check to make sure proper motor speed tap is connected as units are shipped from the factory connected for high speed operation (Speed Tap 5). Airflow Operating Limits NOTE:See Airflow Performance Data for Recommended Blower Motor Speed. [ ] Designates Metric Conversions Model Cabinet Size 17 21 24 25 Cooling BTUH Cooling Tons Nominal 18,000 1.5 24,000 2 30,000 2.5 36,000 3 42,000 3.5 48,000 4 60,000 5 60,000 5 Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 675 [319] 900 [425] 1125 [531] 1350 [637] 1575 [743] 1800 [850] 2025 [956] 2250 [1062] Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 600 [283] 800 [378] 1000 [472] 1200 [566] 1400 [661] 1600 [755] 1800 [850] 2000 [944] Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 540 [255] 720 [330] 900 [425] 1080 [510] 1260 [595] 1440 [680] 1620 [765] 1800 [850] Maximum KW Electric Heating & Minimum Electric Heat CFM [L/s] 11 560 [264] 11 560 [264] 14 900 [425] 14 900 [425] 18 1220 [576] 18 1220 [576] 21 1460 [689] 21 1460 [689] Maximum Electric Heat Rise °F [°C]85 [29]85 [29]70 [21]70 [21]65 [18]65 [18]65 [18]65 [18] Air Airflow Performance Data RBHP Series 8 Airflow Performance Data Model Cabinet Size Tonnage Blower Motor CFM [L/s] (Watts)/External Static Pressure—Inches W.C. [kPa] with filter and Indoor Coil Nominal Speed Tap Volts .10 [.02].20 [.05].30 [.07].40 [.10].50 [.12].60 [.15].70 [.17].80 [.20].90 [.23]1.0 [.25] -17 1.5 Ton Air Flow 2 208/240 659 [311] (74) 625 [294] (80) 581 [274] (84) 539 [254] (88)—————— 3 208/240 790 [372] (98) 759 [358] (105) 722 [340] (113) 687 [324] (119) 650 [306] (126) 615 [290] (131) 573 [270] (139) 552 [260] (145) 507 [239] (150) 460 [217] (155) 2 208/240 649 [306] (79) 615 [290] (84) 571 [269] (88) 529 [249] (92)—————— 3 208/240 773 [365] (110) 736 [347] (113) 699 [330] (118) 677 [320] (126) 640 [302] (132) 605 [286] (141) 563 [266] (146) 542 [256] (154) 497 [235] (157) 450 [212] (162) 2 115 651 [307] (76) 627 [295] (82) 583 [275] (86) 541 [255] (90)—————— 3 115 776 [366] (105) 743 [351] (109) 724 [342] (118) 687 [324] (122) 658 [311] (131) 617 [291] (136) 595 [281] (144) 555 [262] (148) 517 [244] (152) 460 [217] (162) 4 115 846 [399] (143) 821 [387] (148) 801 [378] (157) 766 [361] (162)———— 2.0 Ton Air Flow 4 208/240 844 [398] (141) 819 [386] (146 799 [377] (155) 764 [360] (160)—————— 4 208/240 834 [393] (146) 809 [831] (150) 789 [372] (159) 754 [355] (164)—————— 5 208/240 946 [446] (179) 922 [435] (189) 902 [426] (193) 876 [413] (203) 843 [398] (206) 804 [380] (216) 773 [365] (221) 748 [353] (231) 696 [328] (240) 660 [311] (243) —— 5 115 964 [455] (167) 945 [446] (178) 914 [431] (181) 888 [419] (191) 861 [406] (196) 821 [387] (205) 787 [372] (210) 761 [359] (218) 726 [342] (220) 690 [326] (230) 2 208/240 1068 [504] (138) 1041 [491] (147) 1001 [472] (153) 972 [458] (161)—————— 3 115 1138 [537] (175) 1113 [525] (186) 1075 [507] (191) 1053 [497] (203) 1004 [474] (210) 957 [451] (216) 932 [440] (226) 901 [425] (231) 2 208/240 1035 [488] (143) 1007 [475] (152) 966 [455] (158) 936 [441] (169)—————— 3 208/240 1157 [546] (182) 1132 [534] (192) 1095 [517] (198) 1069 [505] (209) 1028 [485] (218) 983 [464] (228) 952 [449] (239) 921 [435] (250) 869 [410] (255) 825 [389] (262) 2 115 1070 [504] (138) 1043 [492] (147) 1004 [473] (153) 974 [459] (161)—————— 855 [404] (242) 800 [378] (252) 4 208/240 1269 [598] (207) 1236 [583] (219) 1174 [554] (226) 1149 [542] (236)—————— 5 208/240 1397 [659] (287) 1377 [649] (307) 1346 [635] (317) 1318 [622] (320) 1291 [609] (322) 1264 [596] (319) 1234 [582] (312) 1190 [561] (326) 1155 [545] (351) 1126 [531] (368) Electric Heaters none 3 (max.) none none 3 (max.) none none none 3 (max.) 3 (max.) none none none 4 (max.) 4 (max.) none none none 4 208/240 1241 [585] (222) 1208 [570] (234) 1174 [554] (241) 1149 [542] (251)—————— 4 115 1269 [598] (207) 1236 [583] (219) 1174 [554] (226) 1149 [542] (236)—————— 5 115 1370 [646] (292) 1343 [634] (302) 1309 [618] (309) 1285 [607] (319) 1258 [594] (330) 1221 [576] (336) 1182 [558] (348) 1147 [542] (357) 1117 [527] (366) 1080 [510] (375) 4 (max.) none none 5 208/240 958 [452] (162) 934 [440] (172) 914 [431] (176) 888 [419] (186) 855 [403] (189) 816 [380] (210) 785 [370] (204) 760 [358] (214) 708 [334] (223) 672 [317] (226)none 5 208/240 1366 [645] (302) 1346 [635] (313) 1315 [621] (323) 1287 [608] (331) 1260 [595] (341) 1233 [582] (346) 1203 [568] (358) 1159 [547] (371) 1124 [530] (381) 1095 [517] (387)4 (max.) 3 208/240 1187 [560] (180) 1162 [548] (188) 1125 [530] (192) 1099 [518] (200) 1058 [499] (208) 1013 [478] (215) 982 [463] (223) 951 [448] (232) 899 [424] (234) 855 [403] (237)none 2.5 Ton Air Flow -21 3.0 Ton Air Flow NOTES: X-13 (ECM) NOTES (X-13 (ECM) Motor Speed Changes) X-13 (ECM) Motors require no voltage change between 208 and 240 volts. If application exceeds 0.5" of static, adjust the motor speed to the high static speed as described below: All X-13 (ECM) motors have 5 speed tabs. Speed tab 1 is for continuous fan. Speed 2 (Low Static) and speed tab 3 (High Static) are lower tonnage. Speed tab 4 (Low Static) and Speed tab 5 (High Static) are for higher tonnage. The lower static speed 2 (lower tonnage) and speed tab 4 (Higher tonnage) are used for external static below 0.5". For external static exceeding 0.5", move the blue wire from the X-13 (ECM) motor to appropriate high static speed tab 3 (Lower tonnage) or speed tab 5 (Higher tonnage) [ ] Designates Metric Conversions Air Airflow Performance Data RBHP Series 9 Airflow Performance Data (con’t.) Model Cabinet Size Tonnage Blower Motor CFM [L/s] (Watts)/External Static Pressure—Inches W.C. [kPa] with filter and Indoor Coil Nominal Speed Tap Volts .10 [.02].20 [.05].30 [.07].40 [.10].50 [.12].60 [.15].70 [.17].80 [.20].90 [.23]1.0 [.25] -24 3.5 Ton Air Flow 2 208/240 1438 [678] (205) 1409 [664] (217) 1375 [648] (229) 1341 [632] (252)—————— 3 208/240 1568 [740] (279) 1538 [725] (290) 1507 [711] (303) 1471 [694] (313) 1435 [677] (333) 1403 [662] (338) 1362 [642] (358) 1318 [622] (365) 1287 [607] (374) 1250 [589] (405) 2 208/240 1414 [667] (230) 1384 [653] (242) 1350 [637] (254) 1315 [620] (277)—————— 3 208/240 1548 [730] (304) 1518 [716] (316) 1487 [701] (328) 1451 [684] (338) 1415 [667] (358) 1383 [653] (368) 1342 [633] (388) 1298 [612] (395) 1267 [597] (409) 1230 [580] (455) 2 115 1448 [683] (205) 1419 [669] (217) 1385 [653] (229) 1351 [637] (252)—————— 3 115 1559 [735] (294) 1527 [720] (308) 1497 [706] (322) 1466 [691] (335) 1431 [675] (349) 1378 [650] (367) 1349 [636] (379) 1306 [606] (393) 1271 [599] (406) 1250 [589] (417) 4 115 1642 [774] (311) 1606 [757] (326) 1589 [749] (335) 1561 [736] (376)———— 4 208/240 1640 [773] (311) 1604 [757] (326) 1587 [748] (335) 1559 [735] (376)—————— 4 208/240 1613 [761] (331) 1574 [742] (346) 1557 [734] (355) 1529 [721] (396)—————— 5 208/240 1759 [830] (433) 1732 [817] (447) 1701 [802] (453) 1669 [787] (469) 1637 [772] (482) 1605 [757] (502) 1572 [741] (518) 1516 [715] (536) 1485 [700] (549) 1435 [677] (562) —— 5 115 1811 [854] (423) 1791 [845] (436) 1760 [830] (451) 1730 [816] (464) 1700 [802] (479) 1669 [787] (492) 1606 [757] (516) 1573 [742] (529) 1538 [725] (542) 1462 [689] (555) 2 208/240 1872 [883] (373) 1837 [866] (393) 1798 [848] (407) 1763 [832] (419)—————— 3 115 2075 [979] (497) 2036 [960] (511) 2017 [951] (533) 1984 [936] (553) 1944 [917] (563) 1910 [901] (582) 1889 [891] (599) 1846 [871] (617) 2 208/240 1831 [854] (393) 1795 [847] (413) 1756 [828] (427) 1720 [811] (439)—————— 3 208/240 2043 [964] (517) 2004 [945] (531) 1985 [936] (553) 1951 [920] (573) 1912 [901] (583) 1878[886] (602) 1857 [876] (619) 1814 [856] (637) 1773 836] (646) 1751[826] (658) 2 115 1872 [883] (373) 1837 [866] (393) 1798 [848] (407) 1763 [832] (419)—————— 1805 [851] (626) 1783 [841] (638) 4 or 5 208/240 2102 [992] (550) 2072 [977](568) 2042 [963] (584) 2011 [949] (593) 1974 [931] (610) 1949 [919] (631) 1916 [904] (644) 1884 [889] (662) 1851 [873] (669) 1810 [854] (692) 4 or 5 208/240 2070 [976] (560) 2040 [962](578) 2010 [948] (594) 1979 [933] (613) 1942 [916] (620) 1917 [904] (641) 1884 [889] (654) 1852 [874] (672) 1819 [858] (679) 1778 [839] (702) Electric Heaters none 5 (max.) none none 5 (max.) none none none 5 (max.) 5 (max.) none none none 5 (max.) 5 (max.) none none 5 (max.) 4 or 5 115 2102 [992] (550) 2072 [977](568) 2042 [963] (584) 2011 [949] (593) 1974 [931] (610) 1949 [919] (631) 1916 [904] (644) 1884 [889] (662) 1851 [873] (669) 1810 [854] (692)none 5 208/240 1789 [844] (413) 1762 [831] (427) 1731 [816] (433) 1699 [801] (449) 1667 [786] (462) 1635 [771] (482) 1602 [756] (498) 1546 [729] (516) 1515 [715] (529) 1465 [691] (542)none 3 208/240 2075 [979] (497) 2036 [960] (511) 2017 [951] (533) 1984 [936] (553) 1944 [917] (563) 1910 [901] (582) 1889 [891] (599) 1846 [871] (617) 1805 [851] (626) 1783 [841] (638)none 4.0 Ton Air Flow 5.0 Ton Air Flow-25 NOTES: X-13 (ECM) NOTES (X-13 (ECM) Motor Speed Changes) X-13 (ECM) Motors require no voltage change between 208 and 240 volts. If application exceeds 0.5" of static, adjust the motor speed to the high static speed as described below: All X-13 (ECM) motors have 5 speed tabs. Speed tab 1 is for continuous fan. Speed 2 (Low Static) and speed tab 3 (High Static) are lower tonnage. Speed tab 4 (Low Static) and Speed tab 5 (High Static) are for higher tonnage. The lower static speed 2 (lower tonnage) and speed tab 4 (Higher tonnage) are used for external static below 0.5". For external static exceeding 0.5", move the blue wire from the X-13 (ECM) motor to appropriate high static speed tab 3 (Lower tonnage) or speed tab 5 (Higher tonnage) [ ] Designates Metric Conversions Air Electrical Data RBHP Series 10 Blower Motor Electrical Data: A Voltage (115V) Electric Heat Electrical Data Blower Motor Electrical Data: J Voltage (208/240V) Model Size/Elec. Designation Voltage Phase Hertz HP [W]RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector RBHP-17A00NH*115 1 60 1/3 [249]300-1100 5 3.3 5.0 15 RBHP-21A00NH*115 1 60 1/2 [373]300-1100 5 5.0 7.0 15 RBHP-24A00NH*115 1 60 3/4 [559]300-1100 5 5.8 8.0 15 RBHP-25A00NH*115 1 60 3/4 [559]300-1100 5 7.7 10.0 15 Model Elec./KW Designation PH/HZ Type Supply Circuit Single Circuit Multiple Circuit Minimum Circuit Ampacity RBHP-17J06SH*1/60 Single Circuit 25/29 Heater KW Volts 208/240 3.7/4.9 Heater No./KW & 240V 2/2.5 Circuit Amps. 19.8/22.4 Maximum Circuit Protector 25/30 RBHP-17J07SH*1/60 Single Circuit 35/395.3/7.0 2/3.5 27.5/31.2 40/40 RBHP-17J11SH*1/60 Single Circuit 48/557.5/10.0 3/3.3 38.1/43.7 50/60 RBHP-21J06SH*1/60 Single Circuit 27/303.7/4.9 2/2.5 20.9/23.5 30/30 RBHP-21J07SH*1/60 Single Circuit 36/415.3/7.0 2/3.5 28.6/32.3 40/45 RBHP-21J11SH*1/60 Single Circuit 49/567.5/10.0 3/3.3 39.2/44.8 50/60 RBHP-21J14SH*1/60 Single Circuit 68/7710.5/14.0 4/3.5 54.1/61.4 70/80 Multiple Ckt. 1 36/415.3/7.0 2/3.5 28.6/32.3 40/45 Multiple Ckt. 2 32/375.3/7.0 2/3.5 25.5/29.2 35/40 RBHP-24J06SH*1/60 Single Circuit 28/313.7/4.9 2/2.5 22.0/24.6 30/35 RBHP-24J07SH*1/60 Single Circuit 38/425.3/7.0 2/3.5 29.7/33.4 40/45 RBHP-24J11SH*1/60 Single Circuit 51/587.5/10.0 3/3.3 40.3/45.9 60/60 RBHP-24J18SH*1/60 Single Circuit 85/9713.2/17.5 5/3.5 67.7/77.1 90/100 Multiple Ckt. 1 38/425.3/7.0 2/3.5 29.7/33.4 40/45 Multiple Ckt. 2 48/557.9/10.5 3/3.5 38.0/43.8 50/60 RBHP-25J11SH*1/60 Single Circuit 53/607.5/10.0 3/3.3 41.8/47.4 60/60 RBHP-25J18SH*1/60 Single Circuit 87/9913.2/17.5 5/3.5 69.2/78.6 90/100 Multiple Ckt. 1 39/445.3/7.0 2/3.5 31.2/34.9 40/45 Multiple Ckt. 2 48/557.9/10.5 3/3.5 38.0/43.8 50/60 RBHP-25J21SH*1/60 Single Circuit 98/11215.0/20.0 6/3.3 77.8/89.0 100/125 Multiple Ckt. 1 53/607.5/10.0 3/3.3 41.8/47.4 60/70 Multiple Ckt. 2 46/537.5/10.0 3/3.3 36.1/41.7 50/60 Supply circuit protective devices may be fuses or “HACR” type circuit breakers. Largest motor load is included in single circuit and circuit 1 multiple circuit. If non-standard fuse size is specified, use next size larger standard fuse size. [ ] Designates Metric Conversions Model Size/Elec. Designation Voltage Phase Hertz HP [W]RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector RBHP-17A00NH*115 1 60 1/3 [249]300-1100 5 3.3 5.0 15 RBHP-21A00NH*115 1 60 1/2 [373]300-1100 5 5.0 7.0 15 RBHP-24A00NH*115 1 60 3/4 [559]300-1100 5 5.8 8.0 15 RBHP-25A00NH*115 1 60 3/4 [559]300-1100 5 7.7 10.0 15 Air Electrical Wiring RBHP Series 11 Electrical Wiring Combustible Floor Base for Downflow Installations Model Cabinet Size Combustible Floor Base Model Number Opening Front of Unit “W” Width-Inches [mm] Opening Side of Unit “D” Depth-Inches [mm] All Models RXBB-AA 143/8" [365]205/8" [524] ACCESSORIES—KITS—PARTS •Combustible Floor Base RXBB-AA for downflow applications. •Jumper Bar Kit 3 Ckt. to 1 Ckt. RXBJ-A31 is used to convert single phase multiple three circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. •Jumper Bar Kit 2 Ckt. to 1 Ckt. RXBJ-A21 is used to convert single phase multiple two circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. •Note:No jumper bar kit is available to convert three phase multiple two circuit units to a single supply circuit. •Finger Safe Circuit Breaker Cover—Part Number 45-23203-01. One is required for each circuit breaker pole, if jumper bar is removed to provide multiple supply circuits. •Evaporator Horizontal Drain Pan Model RXBD-CB:all unit sizes. •External Auxiliary Horizontal Drain Pan. RXBM-AA06—Fits all models. •Replacement Filters Model Cabinet Size Filter Size In. [mm] Part Number 17 16.25 x 21 [413 x 533] 54-23217-02 21 19.75 x 21 [502 x 533] 54-23217-03 24 23.25 x 21 [591 x 533] 54-23217-04 25 23.25 x 21 [591 x 533] 54-23217-04 [ ] Designates Metric Conversions Power Wiring • Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. •Supply wiring must be 75°C minimum copper conductors only. •See electrical data for product Ampacity rating and Circuit Protector requirement. Grounding • This product must be sufficiently grounded in accordance with National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. •A grounding lug is provided. Air Limited Warranty RBHP Series 12 GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required)..........Ten (10) Years *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Air Notes RBHP Series 13 Air Notes RBHP Series 14 Air Notes RBHP Series 15 The new degree of comfort.™ Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A 1/18 QG FORM NO. H11-544 REV. 1 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5