Loading...
HomeMy WebLinkAboutEnergy Codey J FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 17 Block 1 Waterstone 1820 BGR Builder Name: ADAMS HOMES Street: 5384 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2120.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ftZ b. Frame - Wood, Adjacent R=13.0 270.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedroom's 4 d. N/A R= ftZ 5. Is this a worst case? No 10. Ceiling Types (1820.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ftZ) 1820 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows(239.3 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 364 a. U-Factor: Dbl, U=0.33 136.36 ftZ SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.30 32.38 ftZ SHGC: SHGC=0.23 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 38.19 ftZ a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.251 ft. Area Weighted Average SHGC: 0.269 14. Hot water systems 8. Floor Types (1820.0 sqft.) Insulation Area a. Electric Cap: 40 gallonsEF: a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftZ b. Conservation features 0.940 b. N/A R= ftZ None c. N/A R= ftZ 15. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 62.37 PASS Total Baseline Loads: 68.66 I hereby certify that the plans ications covered _R_e-v'NV of the plans and ��'CKfi S74,7, this calculation are in comp ' n h the Flori rgy specifications covered by this Code. calculation indicates compliance �j ii,, ' `' ' ' .�, with the Florida Energy Code. PREPARED BY: Before construction is completed r DATE: 10-91-2090 Winn KPnmany this building will be inspected for compliance with Section 553.908 - - X * I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Code. OWNER/AGEW. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FIL,e cop, 10/21/2020 9:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPf)RT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 17 Block 1 Waterstone 18 Bedrooms: 4 User Conditioned Area: 1820 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 17 Block/Subdivision: Waterstone PlatBook: Street: 5384 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ftZ ---- 0.42 0 0.58 ROOF / # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ftz 456 ftZ Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING , # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ftz 0.11 Wood 10/21/2020 9:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 NW Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ftz 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 ftz 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ftz 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ftz 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ftz 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .25 3 6 8 20 ftz 2 Wood Main None .25 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ftz 1 ft 4 in 0 ft 10 in None Exterior 5 2 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft' 1 ft 4 in 0 ft 10 in None Exterior 5 3 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ftz 9 ft 4 in 0 ft 0 in None None 4 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ftz 1 ft 4 in 1 ft 0 in None None 5 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ftz 1 ft 4 in 1 ft 0 in None Exterior 5 6 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 9 ft 4 in 1 ft 6 in None None 7 SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftz 1 ft 4 in 0 ft 10 in None Exterior 5 8 SW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftz 12 ft 0 in 0 ft 6 in None None 9 SW 4 Vinyl Low-E Double Yes 0.3 0.23 N 32.4 ftz 1 ft 4 in 0 ft 10 in None Exterior 5 10 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftz 12 ft 0 in 0 ft 6 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 596 ftz 596 ftz 64 ft aft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 10/21/2020 9:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY IC'I-IFCKI IST RFPC)RT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinX Jan Feb Mar Mar Apr Apr Jul May Jun Jul May r�Jun rl u u Mug Se Se rlSep Oct Oct Nov Nov HX Dec Dec H LX Ventin Jan [ Feb X Mar lX� A r [ L Ma Jun Jul [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 10/21/2020 9:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1820 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor: (weighted average) 7a. 0.342 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 34.6 c) Area 7c. 239.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Sign Date: Address of New Home: 5384 Lugo Street City/FL Zip: Fort Pierce, FL 34951 10/21/2020 9:48:12 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1