HomeMy WebLinkAboutWS 21 - Plans [ds] 1.4.2021K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______THESE PLANS HAVE BEEN PREPARED TO MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, 7th Edition (2020) RESIDENTIAL w/ APPLICABLE SUPPLEMENTS OCCUPANCY: R3 BUILDING TYPE: VB SPRINKLED: NO FLOOD ZONE: ’X’ TERMITE PROBABILITY: VERY HEAVY LOT 021 ABBREVIATIONS MAS MAT MAX MC MIN M.O. MTL N.I.C. (NTS) OHGD OPER OPNG OPT OSB OZ 1/R 1/S PC PNL PLYWD PREFAB PR PROJ PSI PSF P.T. QUAD REF REINF REQ’D RNG R.O. R RND MASONRY ML MATERIAL MAXIMUM MEDICINE CABINET MINIMUM MICRO LAM MASONRY OPENING METAL NOT IN CONTRACT NOT TO SCALE OVERHEAD GARAGE DOOR OPERATOR OPENING OPTIONAL ORIENTED STRAND BOARD OUNCE ONE ROD ONE SHELF PRECAST PANEL PLYWOOD PREFABRICATED PAIR PROJECTED POUNDS PER SQUARE INCH POUNDS PRE SQUARE FOOT PRESSURE TREATED QUADRUPLE REFRIGERATOR REINFORCED REQUIRED RANGE ROUGH OPENING RISER ROUND MECH MECHANICAL MIR MIRROR AB A.F.F. ADJ. ALUM. ANCH @ BD. BLDG. BM. BLKG BRG. BRK. C.J. CMU COL. CONC. COND. CONT. CANT. CLG. CM CR D d DBL. DIA. DIR. DN DR DW DWG D.S. DTL EA. E.J. ELEC. CL BF ANCHOR BOLT ABOVE FINISH FLOOR ADJUSTABLE ALUMINUM ANCHOR ANGLE AT BOARD BI−FOLD BUILDING BEAM BLOCKING BEARING BRICK CONTROL JOINT CENTER LINE CONCRETE MASONRY UNIT COLUMN CONCRETE CONDITION CONTINUOUS CANTILEVER CEILING CROWN MOLDING CHAIR RAIL DRYER PENNY DOUBLE DIAMETER DIRECTION DOWN DOOR DISH WASHER DRAWING DOWNSPOUT DETAIL EACH EXPANSION JOINT ELECTRICAL B.O.BOTTOM OF O.C.ON CENTER PKT POCKET DOOR OBS OBSCUREDB.P.BI−PASS DOOR PDS PULL−DOWN STAIR FD FND. FLR. FP FR FRM FTG GA. GALV. GC GEN GYP. GL HGT. HDR. HB INSUL. INT. LT FLOOR DRAIN FOUNDATION FLOOR FIREPLACE FIRE RATED FRAME FOOTING GAUGE GALVANIZED GENERAL CONTRACTOR GENERAL GYPSUM GLUE LAM HEIGHT HEADER HOSE BIBB INSULATION INTERIOR LAUNDRY TUB HC HOLLOW CORE HORIZ.HORIZONTAL FINISHED FLOORFIN. LAVATORYLAV. ELEV EQ. EQUIP. EXP EXT. EE ELEVATION EQUAL EQUIPMENT EXPANSION EXTERIOR EACH END FXD FIXED GLS GLASS H HIGH R&S SC SCHEM SHLF SHT SIM S.S. STL STRUCT SUSP SGD SQ TB T&G TYP T TR TRPL U.N.O. VERT V.L.I.F. W W/ WD WWM WDW ROD AND SHELF SOLID CORE SCHEMATIC SHELF SHEET SIMILAR STAINLESS STEEL STEEL STRUCTURAL SUSPENSION SLIDING GLASS DOOR SQUARE TOWEL BAR TONGUE AND GROOVE TYPICAL TREAD TOWEL ROD TRIPLE UNLESS NOTED OTHERWISE VERTICAL VERIFY LOCATION IN FIELD WASHER WITH WOOD WELD WIRE MESH WINDOW WC WATER CLOSET SINGLE HUNGSH SHOWERSHWR TEMP TEMPERED T.O.TOP OF RELEASE HISTORY TERMITE PROTECTION SHALL BE PROVIDED BY DOMINION 2L TERMITICIDE/INSECTICIDE. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 90 Matawan Road Matawan, NJ 07747 (732) 383−2200 TM FRONT & REAR ELEVATIONS FIRST FLOOR PLAN COVERSHEET & BUILDING DATA A2.1 A1.1 CS.1 CS.2 A2.2 ROOF PLAN A5.1 BUILDING SECTIONS A5.2 TYPICAL WALL SECTIONS GENERAL NOTES DRAWING INDEX FIRST FLOOR ELECTRICAL PLANE1.1 SLAB PENETRATION PLANP1.1 SIDE ELEVATIONS A3.1 STRUCTURAL NOTESS−0.0 F−1.0 BLOCK PLAN S−1.3 ROOF FRAMING PLAN SD−1 FOUNDATION DETAILS STRUCTURAL DETAILSSD−2 SLAB PLAN F−2.0 STRUCTURAL DETAILSPBSB−1 WP1 WATERPROOFING DETAILS CS1COVER SHEET &BUILDING DATA1,616 SF "A"ELEVATION 1ST FLR/TOTAL A/C ENTRY TOTAL UR LANAI 35 SF 87 SF 2,118 SF GARAGE 380 SF 14,005 CU. FT.TOTAL VOLUME R302.5 DWELLING−GARAGE OPENING AND PENETRATION PROTECTION OPENINGS AND PENETRATIONS THROUGH THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE IN ACCORDANCE WITH SECTIONS R302.5.1 THROUGH R302.5.3. R302.5.1 OPENING PROTECTION OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMBCORE STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR 20−MINUTE FIRE−RATED DOORS. R302.6 DWELLING−GARAGE FIRE SEPARATION THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL COMPLY WITH SECTION R302.5. ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702.3.5. THE WALL SEPARATION PROVISIONS OF TABLE R302.6 SHALL NOT APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL. TABLE R302.6 DWELLING−GARAGE SEPARATION FROM THE RESIDENCE AND ATTICS NOT LESS THAN 1/2−INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE FROM HABITABLE ROOMS ABOVE THE GARAGE NOT LESS THAN 5/8−INCH TYPE X GYPSUM BOARD OR EQUIVALENT STRUCTURE(S) SUPPORTING FLOOR/CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS SECTION NOT LESS THAN 1/2−INCH GYPSUM BOARD OR EQUIVALENT R302.7 UNDER−STAIR PROTECTION ENCLOSED SPACE UNDER STAIRS THAT IS ACCESSED BY A DOOR OR ACCESS PANEL SHALL HAVE WALLS, UNDER−STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2−INCH (12.7 MM) GYPSUM BOARD. R302.9 FLAME SPREAD INDEX AND SMOKE−DEVELOPED INDEX FOR WALL AND CEILING FINISHES FLAME SPREAD AND SMOKE−DEVELOPED INDEXES FOR WALL AND CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS R302.9.1 THROUGH R302.9.4. R302.10 FLAME SPREAD INDEX AND SMOKE−DEVELOPED INDEX FOR INSULATION FLAME SPREAD AND SMOKE−DEVELOPED INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH SECTIONS R302.10.1 THROUGH R302.10.5. R302.11 FIREBLOCKING IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF BOTH VERTICAL AND HORIZONTAL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD−FRAMED CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: 1.1.VERTICALLY AT THE CEILING AND FLOOR LEVELS. 1.2.HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM). 2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM E136 REQUIREMENTS. 5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003.19. 6. FIREBLOCKING OF CORNICES OF A TWO−FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION. R302.11.1 FIREBLOCKING MATERIALS EXCEPT AS PROVIDED IN SECTION R302.11, ITEM 4, FIREBLOCKING SHALL CONSIST OF THE FOLLOWING MATERIALS. 1. TWO−INCH (51 MM) NOMINAL LUMBER. 2. TWO THICKNESSES OF 1−INCH (25.4 MM) NOMINAL LUMBER WITH BROKEN LAP JOINTS. 3. ONE THICKNESS OF 23/32−INCH (18.3 MM) WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY 23/32−INCH (18.3 MM) WOOD STRUCTURAL PANELS. 4. ONE THICKNESS OF 3/4−INCH (19.1 MM) PARTICLEBOARD WITH JOINTS BACKED BY 3/4−INCH (19.1 MM) PARTICLEBOARD. 5. ONE−HALF−INCH (12.7 MM) GYPSUM BOARD. 6. ONE−QUARTER−INCH (6.4 MM) CEMENT−BASED MILLBOARD. 7. BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. 8. CELLULOSE INSULATION INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE SPECIFIC APPLICATION. R302.12 DRAFTSTOPPING IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR−CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR−CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: 1.CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2.FLOOR FRAMING IS CONSTRUCTED OF TRUSS−TYPE OPEN−WEB OR PERFORATED MEMBERS. R302.12.1 MATERIALS DRAFTSTOPPING MATERIALS SHALL BE NOT LESS THAN 1/2−INCH (12.7 MM) GYPSUM BOARD, 3/8−INCH (9.5 MM) WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. : R308.4.1 GLAZING IN DOORS GLAZING IN FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. EXCEPTIONS: 1. GLAZED OPENINGS OF A SIZE THROUGH WHICH A 3−INCH−DIAMETER SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLAZING R308.4.2 GLAZING ADJACENT TO DOORS. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING CONDITIONS: 1. WHERE THE GLAZING IS WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IN THE PLANE OF THE DOOR IN A CLOSED POSITION. 2. WHERE THE GLAZING IS ON A WALL LESS THAN 180 DEGREES FROM THE PLANE OF THE DOOR IN A CLOSED POSITION AND WITHIN 24 INCHES OF THE HINGE SIDE OF AN IN−SWINGING DOOR. EXCEPTIONS: 1. DECORATIVE GLAZING. 2. WHERE THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 3. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH SECTION R308.4.3. 4. GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIO DOORS. R308.4.3 GLAZING IN WINDOWS GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION: 1. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN 9 SQUARE FEET, 2. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES ABOVE THE FLOOR, 3. THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES ABOVE THE FLOOR; AND 4. ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES, 5. MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING. R308.4.5 GLAZING AND WET SURFACES GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING HOT TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. THIS SHALL APPLY TO SINGLE GLAZING AND EACH PANE IN MULTIPLE GLAZING. EXCEPTION: GLAZING THAT IS MORE THAN 60 INCHES, MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, FROM THE WATER’S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR SWIMMING POOL OR FROM THE EDGE OF A SHOWER, SAUNA OR STEAM ROOM. R308.4.6 GLAZING ADJACENT TO STAIRS AND RAMPS GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. R308.4.7 GLAZING ADJACENT TO THE BOTTOM STAIR LANDING GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN A 60−INCH HORIZONTAL ARC LESS THAN 180 DEGREES FROM THE BOTTOM TREAD NOSING SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. : R309.1 FLOOR SURFACE GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. : R310.2.1 MINIMUM OPENING AREA EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES. EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5 SQUARE FEET. R310.2.2 WINDOW SILL HEIGHT WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR. R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM F2090 SHALL BE PERMITTED FOR USE ON WINDOWS SERVING AS A REQUIRED EMERGENCY ESCAPE AND RESCUE OPENING. R312.2.1 WINDOW SILLS IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES (1829 MM) ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING: 1. OPERABLE WINDOWS WITH OPENINGS THAT WILL NOT ALLOW A 4−INCH−DIAMETER (102 MM) SPHERE TO PASS THROUGH THE OPENING WHERE THE OPENING IS IN ITS LARGEST OPENED POSITION. 2. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F2090. 3. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH SECTION R312.2.2. : R311.7.1 WIDTH STAIRWAYS SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. THE CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL BE NOT LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698 MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. R311.7.2 HEADROOM THE HEADROOM IN STAIRWAYS SHALL BE NOT LESS THAN 6 FEET 8 INCHES (2032 MM) MEASURED VERTICALLY FROM THE SLOPED LINE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR PLATFORM ON THAT PORTION OF THE STAIRWAY. R311.7.5 STAIR TREADS AND RISERS STAIR TREADS AND RISERS SHALL MEET THE REQUIREMENTS OF THIS SECTION. FOR THE PURPOSES OF THIS SECTION, DIMENSIONS AND DIMENSIONED SURFACES SHALL BE EXCLUSIVE OF CARPETS, RUGS OR RUNNERS. R311.7.5.1 RISERS THE RISER HEIGHT SHALL BE NOT MORE THAN 73/4 INCHES (196 MM). THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENINGS LOCATED MORE THAN 30 INCHES (762 MM), AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A 4−INCH−DIAMETER (102 MM) SPHERE. R311.7.5.2 TREADS THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD’S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). R311.7.5.3 NOSINGS NOSINGS AT TREADS, LANDINGS AND FLOORS OF STAIRWAYS SHALL HAVE A RADIUS OF CURVATURE AT THE NOSING NOT GREATER THAN 9/16 INCH (14 MM) OR A BEVEL NOT EXCEEDING 1/2 INCH (12.7 MM). A NOSING PROJECTION NOT LESS THAN 3/4 INCH (19 MM) AND NOT MORE THAN 11/4 INCHES (32 MM) SHALL BE PROVIDED ON STAIRWAYS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST NOSING PROJECTION BY MORE THAN 3/8 INCH (9.5 MM) WITHIN A STAIRWAY. EXCEPTION: A NOSING PROJECTION IS NOT REQUIRED WHERE THE TREAD DEPTH IS NOT LESS THAN 11 INCHES (279 MM). R311.7.8 HANDRAILS HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH FLIGHT WITH FOUR OR MORE RISERS. R311.7.8.1 HEIGHT HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM). EXCEPTIONS: 1. THE USE OF A VOLUTE, TURNOUT OR STARTING EASING SHALL BE ALLOWED OVER THE LOWEST TREAD. 2. WHERE HANDRAIL FITTINGS OR BENDINGS ARE USED TO PROVIDE CONTINUOUS TRANSITION BETWEEN FLIGHTS, TRANSITIONS AT WINDER TREADS, THE TRANSITION FROM HANDRAIL TO GUARD, OR USED AT THE START OF A FLIGHT, THE HANDRAIL HEIGHT AT THE FITTINGS OR BENDINGS SHALL BE PERMITTED TO EXCEED 38 INCHES (956 MM). R311.7.8.2 CONTINUITY HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 11/2 INCHES (38 MM) BETWEEN THE WALL AND THE HANDRAILS. EXCEPTIONS: 1. HANDRAILS SHALL BE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AT THE TURN. 2. THE USE OF A VOLUTE, TURNOUT, STARTING EASING OR STARTING NEWEL SHALL BE ALLOWED OVER THE LOWEST TREAD. R311.7.8.3 GRIP−SIZE REQUIRED HANDRAILS SHALL BE OF ONE OF THE FOLLOWING TYPES OR PROVIDE EQUIVALENT GRASPABILITY. 1. TYPE I. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 11/4 INCHES (32 MM) AND NOT GREATER THAN 2 INCHES (51 MM). IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF NOT LESS THAN 4 INCHES (102 MM) AND NOT GREATER THAN 61/4 INCHES (160 MM) WITH A CROSS SECTION OF DIMENSION OF NOT MORE THAN 21/4 INCHES (57 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01 INCH (0.25 MM). 2. TYPE II. HANDRAILS WITH A PERIMETER GREATER THAN 61/4 INCHES (160 MM) SHALL HAVE A GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. THE FINGER RECESS SHALL BEGIN WITHIN A DISTANCE OF 3/4 INCH (19 MM) MEASURED VERTICALLY FROM THE TALLEST PORTION OF THE PROFILE AND ACHIEVE A DEPTH OF NOT LESS THAN 5/16 INCH (8 MM) WITHIN 7/8 INCH (22 MM) BELOW THE WIDEST PORTION OF THE PROFILE. THIS REQUIRED DEPTH SHALL CONTINUE FOR NOT LESS THAN 3/8 INCH (10 MM) TO A LEVEL THAT IS NOT LESS THAN 13/4 INCHES (45 MM) BELOW THE TALLEST PORTION OF THE PROFILE. THE WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE NOT LESS THAN 11/4 INCHES (32 MM) AND NOT MORE THAN 23/4 INCHES (70 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01 INCH (0.25 MM). : R312.1.1 WHERE REQUIRED GUARDS SHALL BE PROVIDED FOR THOSE PORTIONS OF OPEN−SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 24 INCHES (610 MM) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD. R312.1.2 HEIGHT REQUIRED GUARDS AT OPEN−SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS. EXCEPTIONS: 1. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES (864 MM) MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. 2. WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM) AS MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. R312.1.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER. EXCEPTIONS: 1. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR, FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (153 MM) IN DIAMETER. 2. GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 43/8 INCHES (111 MM) IN DIAMETER. : R506.2.3 VAPOR RETARDER A 6−MIL (0.006 INCH; 152 ΜM) POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS. EXCEPTION: THE VAPOR RETARDER IS NOT REQUIRED FOR THE FOLLOWING: 1. GARAGES, UTILITY BUILDINGS AND OTHER UNHEATED ACCESSORY STRUCTURES. 2. FOR UNHEATED STORAGE ROOMS HAVING AN AREA OF LESS THAN 70 SQUARE FEET (6.5 M2) AND CARPORTS. 3. DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOT LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE. 4. WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ON LOCAL SITE CONDITIONS. : R702.4.2 BACKER BOARDS MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS SHALL BE OF MATERIALS LISTED IN TABLE R702.4.2, AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS. TABLE R702.4.2BACKER BOARD MATERIALS GLASS MAT GYPSUM BACKING PANEL (ASTM C1178) FIBER−REINFORCED GYPSUM PANELS (ASTM C1278) NONASBESTOS FIBER−CEMENT BACKER BOARD (ASTM C1288 OR ISO 8336, CATEGORY C) NONASBESTOS FIBER MAT REINFORCED CEMENTITIOUS BACKER UNITS (ASTM C1325) WINDOW INSTALLATION WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. R703.4 FLASHING APPROVED METAL FLASHING, VINYL FLASHING, SELF−ADHERED MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED SHINGLE−FASHION OR IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS. METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID−APPLIED MEMBRANES USED AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF−ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, ASTM C1281, AAMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. FLUID−APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS: 1.EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER−RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING: 1.1. THE FENESTRATION MANUFACTURER’S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER’S INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURER’S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER−RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES. 1.2. IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. 1.3. IN ACCORDANCE WITH OTHER APPROVED METHODS. 1.4. IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD−FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. R903.2 FLASHING FLASHINGS SHALL BE USED TO SEAL ROOFING SYSTEMS, WHERE THE SYSTEM IS INTERRUPTED OR TERMINATED AND SHALL BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. R903.2.1 LOCATIONS FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN PROVIDED IN TABLE R903.2.1 OR IN COMPLIANCE WITH RAS 111. EXCEPTION: FLASHING IS NOT REQUIRED AT HIP AND RIDGE JUNCTIONS. R903.2.3 MEMBRANE FLASHINGS ALL MEMBRANE FLASHING SHALL BE INSTALLED ACCORDING TO THE ROOF ASSEMBLY MANUFACTURER’S PUBLISHED LITERATURE. R905.2.4.1 WIND RESISTANCE OF ASPHALT SHINGLES (IF APPLICABLE) ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS R905.2.6 AND R905.2.6.1. : M1501.1 OUTDOOR DISCHARGE THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS IN ACCORDANCE WITH SECTION M1506.3. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. M1502.4.5 DRYER DUCT LENGTH THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE DETERMINED BY ONE OF THE METHODS SPECIFIED IN SECTIONS M1502.4.5.1 THROUGH M1502.4.5.3. M1502.4.5.1 SPECIFIED LENGTH THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET (10 668 MM) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH TABLE M1502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. M1502.4.5.2 MANUFACTURER’S INSTRUCTIONS THE SIZE AND MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE DETERMINED BY THE DRYER MANUFACTURER’S INSTALLATION INSTRUCTIONS. THE CODE OFFICIAL SHALL BE PROVIDED WITH A COPY OF THE INSTALLATION INSTRUCTIONS FOR THE MAKE AND MODEL OF THE DRYER AT THE CONCEALMENT INSPECTION. IN THE ABSENCE OF FITTING EQUIVALENT LENGTH CALCULATIONS FROM THE CLOTHES DRYER MANUFACTURER, TABLE M1502.4.5.1 SHALL BE USED. M1502.4.5.3 DRYER EXHAUST DUCT POWER VENTILATOR THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE DETERMINED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS FOR THE DRYER EXHAUST DUCT POWER VENTILATOR. ATTENTION GENERAL CONTRACTOR / BUILDER: ISSUANCE OF PLANS FROM THE ARCHITECT SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION CORRECTION / REVISIONS. ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE ARCHITECT, THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE. INSPECTION NOTES: WORK SHALL NOT BE DONE BEYOND THE POINT INDICATED IN EACH SUCCESSIVE INSPECTION WITHOUT FIRST OBTAINING THE APPROVAL OF THE BUILDING OFFICIAL. THE BUILDING OFFICIAL, UPON NOTIFICATION, SHALL MAKE THE REQUESTED INSPECTIONS AND SHALL EITHER INDICATE THE PORTION OF THE CONSTRUCTION THAT IS SATISFACTORY AS COMPLETED, OR NOTIFY THE PERMIT HOLDER OR HIS OR HER AGENT WHEREIN THE SAME FAILS TO COMPLY WITH THIS CODE. ANY PORTIONS THAT DO NOT COMPLY SHALL BE CORRECTED AND SUCH PORTION SHALL NOT BE COVERED OR CONCEALED UNTIL AUTHORIZED BY THE BUILDING OFFICIAL. FOUNDATION INSPECTION NOTES: A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTOR’S USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. EXTERIOR FINISHES: 1. CEMENT PLASTER FINISH OVER MASONRY SHALL BE 5/8" THICK TEXTURED PER COMMUNITY STANDARDS. 2. CEMENT PLASTER FINISH OVER WOOD SUBSTRATE SHALL BE 7/8" THICK (3) COAT STUCCO OVER (2) LAYERS OF WATER RESISTANT BARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL, R703 AND ASTM C926. TEXTURE PER COMMUNITY FLOOD ZONE REQUIREMENTS: PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. MECHANICAL AND HVAC: 1. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. 2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762 mm) DEEP AND 30 INCHES (762 mm) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 mm) ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS M1411.3. GENERAL CONSTRUCTION NOTES CS.2GENERAL NOTESK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ 10’−8"30’−11"2’−4"10’−2"7’−212"14’−112"6’−2"7’−4" 5’−51 2"10’−912"2’−4"10’−912"10’−9"5’−11" 4’−4"18’−8" 5’−41 2"5’−4"58’−8"64’−0"12’−9"12’−6"11’−2" 10’−0" 5’−9"4’−912"6’−0"14’−3"10’−1112"17’−6"55’−4"8’−0"8’−41 2"2’−10 1 2"3’−6"35’−0" 3’−6" 9’−11 2"14’−1"206828682868286828682868286828686068 SGD TEMP35 SH *25 SH 37"x63" EGRESS 16070 GARAGE DOOR 5’−101 2"4’−31 2"20688’−8"3’−1112"1’−81 2"28682868BRKBRKBRKBRKBRK BRK BRK 5’−51 2" 3’−7 1 2" 10’−8 1 2" 8’−91 2"BRK22’−3"33’−1"12’−0" 6’−1"2’−3"2’−1"1’−4"16’−0"1’−4"20’−0"27’−9"4’−3" 6’−1"12’−0" 25’−0" 35’−0"64’−0"DROPPED SOFFIT @ 8’−0"D/W3’−912"2x6 LOW WALLLAV8" BRK 11’−312"28682868LAVLAVBRKBRK 2’−1112"BRK35 SH 4’−5"4’−3"2868 12" SHFLAT SOFFIT AT 7’−4" 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG. 8’−8" CLG.8’−8" CLG. 8’−8" CLG. LINE OF 2" CONC. CURB 1/2" WALL BOARD ON GARAGE SIDE PROVIDE INSULATION AS REQ’D 22’’ X 54’’ ATTIC ACCESS R&S R&S R&S 4’−41 2"7’−10 1 2" (4) 12" SH 10" 36"x60" ACRYLIC PAN SHWR R&S 6"5’−31 2"4’−8" R&S 13’−112"14’−9"TUB PER COMMUNITY SPECS (4)12" SH7’−1"3’−7"2’−1112"16’−412"*25 SH37"x63" EGRESS*35 SH 54"X63" EGRESS *25 SH37"x63" EGRESSR&S HI/LO6’−11" 3’−2" CL 3’−5" CL 1’−1112"CL 3’−11" CL 3’−10"CL AHU ON STAND METAL RAG LOCATION XFER GRILL XFER GRILL XFER GRILL CONCRETE FLAT SOFFIT @ 7’−4"FLAT SOFFIT @ 7’−4"8’−8" CLG. 1’−4"8’−8" 8’−8" CLG. BRK EXT.HB.LOCATION VARIES PER MAIN WATER SERVICE CONNECTION3’−712"28685’−4"3’−412"36" REF 2’−21 2" CL 2X6 WALL BRK RANGE6’−71 2"CL ADD 7 16" OSB TO MECH. CL. CEILING FOR FIRE DRAFT STOP 7’−6"15’−3" 51 2" REF. WATER LINE 2868 SC W/ SELF CLOSER AND METAL THRESHOLD WEATHER STRIPPING METAL THRESHOLD WEATHER STRIPPING MOISTURE RESISTANT DRYWALL CLG. MOISTURE RESISTANT DRYWALL CLG.2’−0"2’−0"3068 SOLIDPANEL DR.EGRESSBRKWASHER BOX DRYER VENT D W REFRIGERANT/ CONDENSATE LINE THROUGH WALL FIRST FLOOR PLAN SCALE: 1/4"=1’−0" * A BRK A1.1FIRST FLOOR PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______2’−11"1’−2" MAX. 2x6 STUD WALL SEE PLANS FOR WALL LAYOUT SUBFLOOR BASE CABINET AS PER SHOP DWG. FINISH FLOOR TOP PLATE 1/2" GYP. BD. WD.BASE MOLDING FINISH FLOOR SOLID SURFACE COUNTERTOP. INSTALLER TO PROVIDE APPROPRIATE COUNTERTOP SUPPORT IF REQUIRED 2x WOOD/STEEL FRAMED PARTITION INTERIOR PARTITION w/ INSULATION CMU WALL CMU WALL w/ FURRING & INSULATION NOTE: INTERIOR WALLS ARE DRAWN TO ROUGH DIMENSIONS DOORS LOCATED ADJACENT TO WALL INTERSECTIONS ARE TO BE PLACED 3" MEASURED FROM INTERSECTION TO DOOR JAMB UNLESS DIMENSIONED OR NOTED OTHERWISE. DOORS LOCATED WITHIN A LENGTH OF WALL ARE TO BE CENTERED UNLESS DIMENSIONED OR NOTED OTHERWISE. A B DOOR ENTRY TRIM DETAIL SCALE: 3/4"=1’−0" 1 REAR ELEVATION SCALE: 1/4"=1’−0" FRONT ELEVATION SCALE: 1/4"=1’−0" NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD & SILL THE TRIM COLOR. PAINT COLOR SCHEME BODY COLOR TRIM COLOR SAND FINISH MEDIUM TEXTURE / SKIP TROWEL FINISH SURFACE TEXTURE / FINISH KEY STUCCO AND PORTLAND CEMENT PLASTER SHALL BE INSTALLED PER THE CURRENT ASTM C926 & C1063 REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE CONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TO DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. OR AT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTS PER ASTM C1063 (CURRENT EDITION) WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY AS REQUIRED BY ASTM C1063 (CURRENT EDITION) STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED OVER METAL OR WIRE LATH AND SHALL NOT BE LESS THAN 2 COATS WHEN APPLIED OVER MASONRY A2.1FRONT & REAR ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ LEFT ELEVATION SCALE: 1/4"=1’−0" NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD & SILL THE TRIM COLOR. PAINT COLOR SCHEME BODY COLOR TRIM COLOR SAND FINISH MEDIUM TEXTURE / SKIP TROWEL FINISH SURFACE TEXTURE / FINISH KEY STUCCO AND PORTLAND CEMENT PLASTER SHALL BE INSTALLED PER THE CURRENT ASTM C926 & C1063 REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE CONTROL JOINTS IN 3−COAT STUCCO SHALL BE USED TO DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. OR AT A MAXIMUM DISTANCE OF 18’ BETWEEN JOINTS PER ASTM C1063 (CURRENT EDITION) WEEP SCREED SHALL BE INSTALLED AT STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY AS REQUIRED BY ASTM C1063 (CURRENT EDITION) STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED OVER METAL OR WIRE LATH AND SHALL NOT BE LESS THAN 2 COATS WHEN APPLIED OVER MASONRY RIGHT ELEVATION SCALE: 1/4"=1’−0" A2.2SIDE ELEVATIONSK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ 5:12 1’−0"1’−0"1’−0"1’−0"1’−0"5:125:125:125:12 1’−0" OFF RIDGE VENT, TYP. R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE VENTED SPACE. EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT LESS THAN 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. ATTIC VENTILATION − AT FIRST FLOOR SQ. FT. ATTIC AREA NET FREE AREA SOFFIT VENTING NET FREE AREA UPPER ROOF VENTING VENTS REQUIRED 48" TAMCO OFF−RIDGE VENT (138 SI NET FREE) − NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL HIPS RIDGES OR VALLEYS, MIN., TYP. TOTAL VENTING REQUIRED ROOF PLAN SCALE: 1/4"=1’−0" UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R905.1.1 FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 FOR TILE ROOFING REFERENCE TO SECTION R905.3 A3.1ROOF PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______ A-5.1 1 A-5.1 1 ROOF SHINGLES PER COMMUNITY SPECS. (TYP.) CONCRETE FOOTING SEE STRUCTURAL PLANS FIN. FLR.8’−8"T.O. M. T.O. WDW 7’−4"PRE−ENGINEERED ROOF TRUSSES SEE FRAMING SHEET FOR DETL’S 12 5 12 5 12 5 TRANSFER GRILL R−30 INSULATION R−11 INSULATION R−4.1 INSULATION FIN. FLR.8’−8"T.O. M. 12 5 PRE−ENGINEERED ROOF TRUSSES SEE FRAMING SHEET FOR DETL’S R−30 INSULATION 12 5 ROOF SHINGLES PER COMMUNITY SPECS. (TYP.) A-5.1 2 A-5.1 2 T.O. WDW 7’−4"CONCRETE FOOTING SEE STRUCTURAL PLANS R−4.1 INSULATION R−4.1 INSULATION K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______A5.1BUILDING SECTIONSBUILDING SECTION SCALE: 1/4"=1’−0" BUILDING SECTION SCALE: 1/4"=1’−0" PROVIDE 2X4 FRAMED ENCLOSURE FOR ELECTRICAL PANEL, FINISH W/ 1 2" GYPSUM BOARD ELECTRICAL PANEL CONCRETE CURB REFER TO PLANS ELECTRICAL PANEL CONCRETE CURB REFER TO PLANS GYPSUM BOARD GYPSUM BOARD GARAGE ELECTRICAL PANEL IS TO BE INSTALLED ACCORDING TO ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES. VERIFY PANEL DIMENSIONS PRIOR TO CONSTRUCTION. CONCRETE SLAB ON GRADE AT GARAGE FLOOR ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS 1 2" GYPSUM BOARD NICHE FOR ELECTRICAL PANEL & WIRING 2’−4"6’−2"2’−4"3’−2"6’−2"8"PER PLAN3"1’−0"3" 1’−6" 3 1/2" EXTERIOR CMU BLOCK WALL EXTERIOR CMU BLOCK WALL STUCCO FINISH ELECTRIC METER LOCATION − SEE PLANS. VERIFY INSTALLATION IN FIELD 3’−2"8"PER PLANT.O. M GRADE ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS 3/4"4" PROVIDE 2X4 FRAMED ENCLOSURE FOR ELECTRICAL PANEL, FINISH W/ 1 2" GYPSUM BOARD ELECTRICAL PANEL CONCRETE CURB REFER TO PLANS ELECTRICAL PANEL CONCRETE CURB REFER TO PLANS GYPSUM BOARD GYPSUM BOARD GARAGE ELECTRICAL PANEL IS TO BE INSTALLED ACCORDING TO ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES. VERIFY PANEL DIMENSIONS PRIOR TO CONSTRUCTION. CONCRETE SLAB ON GRADE AT GARAGE FLOOR ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS 1 2" GYPSUM BOARD NICHE FOR ELECTRICAL PANEL & WIRING 2’−4"6’−2"2’−4"3’−2"6’−2"8"PER PLAN3"1’−0"3" 1’−6" 3 1/2" EXTERIOR CMU BLOCK WALL EXTERIOR CMU BLOCK WALL STUCCO FINISH ELECTRIC METER LOCATION − SEE PLANS. VERIFY INSTALLATION IN FIELD 3’−2"8"PER PLANT.O. M GRADE ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS 3/4"4"K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______A5.2TYPICAL WALL SECTIONS FOLD FOLD @ 45° FOLD @ 77° WATERTIGHT SEAL. FOLD. BOTTOM FLANGE 7 8" THICK, 3 COAT CEMENT PLASTER WRAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WRB 1−1/2" ABOVE SHINGLES 5X5 WALL FLASHING KICK−OUT FLASHING (SEE DTL. BELOW) SHINGLE ROOFING FELT UNDERLAYMENT FASCIA WRAP DRIP EDGE: OVERLAP 3", EXTEND BELOW SHEATHING, MECH. FASTEN 4" O.C. MAX. 60 MIN. GRADE D PAPER BACKED LATH BARRICADE PLUS WRB (OR APPROVED EQUAL)6"6"6"EXTERIOR CMU WALL 1) PROTECTO WRAP LWM200 OR SIMILAR ON WINDOW SILL, JAMBS AND HEAD. APPLY AROUND CORNER AND EXTEND 6" ALL AROUND THE EDGES OF THE WALL 2) SET P.T. WOOD BUCK OVER CMU WATERPROOFING IN URETHANE SEALANT. FASTEN PER PRODUCT APPROVALS. 3) APPLY LIQUID WATERPROOFING MEMBRANE OVER THE TOP AND EXTERIOR FACE OF BUCK AND SILL 4) INSTALL WINDOW OR DOOR. FASTEN PER PRODUCT APPROVALS AND SEAL WINDOW OR DOOR FRAME TO P.T. WOOD BUCK AND MASONRY CMU OPENING WATERPROOFING SCALE: N.T.S. SEAL EDGE OF P.T. WOOD BUCK TO MASONRY PRECAST SILL K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______WP-1WATERPROOFING DETAILS D/WA/C DISCONNECT P.C. ATTIC LIGHT 10’−0"2’−0"PREWIRE FOR GARAGE DOOR OPENER P.B. FOR CHIMES 3ADD BLOCKING AS REQUIRED SD 3−BULB FIXTURE 4ADD BLOCKING AS REQUIRED ADD BLOCKING AS REQUIRED SD 333 ADD BLOCKING AS REQUIRED ADD BLOCKING AS REQUIRED CL ADD BLOCKING AS REQUIRED VP 3−BULB FIXTURE ADD BLOCKING AS REQUIRED 334SWITCH FOR DISPOSAL DISCONNECT SD SD 36" REF 34ELECTRICAL PANEL ON 2X4 WALL M IRRIGATION TIMER LOCATION VARIES PER MAIN WATER SERVICE CONNECTION FIELD VERIFY METER CAT 5 CAT 5 RANGESTRUCTURED WIRE PANEL (SWP) VERIFY LOCATION IN FIELD3 VP VP WH DISCONNECT D W 4’−0"3#3/0 AL, 1#6G 1 12" C 150 A MLO PANEL 42 CIRCUITS N1 150 A METER COMBO 120/240V 1ph. N3R 22K AIC 150A/2P #4 GROUND WIRE BLDG STEEL 2 GROUND ROD 5 8"x8’ GALV. 2" PVC STUB DOWN FOR FLORIDA POWER & LIGHT ELECTRICAL RISER DIAGRAM EDEN LOAD CALCULATIONS PANEL "A" DESCRIPTION LOAD KVA GENERAL LTG. 3Wx1616 S.F.4848 SMALL APPLIANCE SMALL APPLIANCE REFRIGERATOR DISHWASHER DISPOSAL MICROWAVE RANGE WATER HEATER DRYER WASHER LAUNDRY EXTERIOR GFI IRRIGATION GDO TOTAL KVA AHU #1 HEAT FIRST 10KW BALANCE @ 40% AC LOAD TOTAL LOAD KVA/240V 1500 1500 1200 2400 850 1200 8000 4500 5000 1500 1500 1500 800 900 37198 10000 KWx.65 6500 10000 10879 6500 27379 114 AMPS WIRE POLE TRIP DESCRIPTION CKT WIREPOLETRIPDESCRIPTIONCKT 1 5 3 7 9 11 13 15 17 19 21 23 25 27 29 31 35 33 37 39 2 6 4 8 10 12 16 14 18 20 22 26 24 28 30 32 36 34 38 40 #10 #6 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #6 #10 #10 #12 #14 #14 #14 #14 #14 #14 2P 2P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 30A 60A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 2P50A 2P 2P 25A 30A 20A 1P 1P 1P 1P 1P 1P 1P 15A 15A 15A 15A 15A 15A SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE AIR COMPRESSOR AIR HANDLER DISHWASHER (AF/GFI) DISPOSAL (AF/GFI) WASHER (AF/GFI) REFRIGERATOR (AF) SMALL APPLIANCE (AF/GFI) SMALL APPLIANCE (AF/GFI) BATH (GFI) GARAGE DR. OPENER (GFI) GARAGE (GFCI) SPRINKLER SOLENOID EXTERIOR (GFI) RANGE WATER HEATER DRYER MICROWAVE (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) GENERAL LTG. (AF) FIRST FLOOR ELECTRICAL PLAN SCALE: 1/4"=1’−0" FOUR−WAY SWITCH CEILING MOUNTED LED LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE VAPOR PROOF LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN FLUORESCENT LIGHT FIXTURE EXHAUST FAN/LIGHT COMBINATION PUSHBUTTON SWITCH (OPTIONAL) ELECTRIC PANEL NOTES: DISCONNECT SWITCH TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) ELECTRIC METER CHIMES (OPTIONAL) SMOKE DETECTOR EXHAUST FAN KEYLESS LIGHT FIXTURE DUPLEX CONVENIENCE OUTLET WEATHERPROOF DUPLEX OUTLET GROUND FAULT INTERRUPTER DUPLEX OUTLET ELECTRICAL KEY 220 VOLT OUTLET WALL SWITCH THREE−WAY SWITCH COMBINATION SMOKE / CO2 DETECTOR 4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, AND GARAGES, SHALL REQUIRE AFCI PROTECTION. JUNCTION BOX 6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC 406.12. 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. 2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR: SWITCHES...........42" OUTLETS.............14" ABOVE COUNTER OUTLETS......46" TELEPHONE.........14" TELEVISION..........14" 1. PROVIDE AND INSTALL GROUND FAULT CIRCUIT−INTERUPTERS (GFI) AND ARC FAULT CIRCUIT INTERRUPTERS (AFCI) PER 2020 NEC 210.12 STANDARD ELECTRICAL LINE 5. 7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. 8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED PER THE PROVISIONS OF 2020 NEC 410.16(A) & (B) 9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED 10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH−EFFICIENCY LAMPS 11. GFCI DEVICES SHALL BE READILY ACCESSIBLE 12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL INFORMATION. 13. 14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH 2020 NFPA 70, FLORIDA RESIDENTIAL CODE 2020, AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS AND DISCONNECTS IN COMPLIANCE WITH NEC 110.26. E1.1FIRST FLOORELECTRICAL PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______LOAD CALCULATIONS SCALE: N.T.S. PANEL SCHEDULE SCALE: N.T.S. ELECT. RISER DIAGRAM SCALE: N.T.S. D/W16’−212"20’−114"23’−3"8’−5"10’−10" 10’−10"14’−912"17’−312"19’−1034"22’−1014"23’−214"5’−7 1 2"HB.36" REF RANGE8’−11 2" 5’−9" D W K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______SLAB PENETRATION PLAN SCALE: 1/4"=1’−0" P1.1SLAB PENETRATION PLANPLUMBING RISER DIAGRAM SCALE: N.T.S.