HomeMy WebLinkAboutAPPROVED, Extreme Metal FL17022_R7_II_FL 17022.1_5 V CRIMP1/13/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvOQveeg%3d%3d 1/3
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
LOCKE BOWDEN
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL17022_R7_COI_FL 17022.1_5 V CRIMP_ssr.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
1/13/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvOQveeg%3d%3d 2/3
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FL #Model, Number or Name Description
17022.1 1 - "5V Crimp" (R6)26 Gauge steel, 3/8" rib height, 24” wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.1_5 V CRIMP_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.1_5 V CRIMP_ssr.pdf
Created by Independent Third Party: Yes
17022.2 2 - "5V Crimp" (R6)0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions.Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.2_5 V CRIMP 0.032 ALUM_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.2_5 V CRIMP 0.032 ALUM_ssr.pdf
Created by Independent Third Party: Yes
17022.3 3 - "1.5" Mechanical Seam" (R5)1.5” rib height, 16” wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.3_1.5 MECHANICAL
seam_24ga_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.3_1.5 MECHANICAL
seam_24ga_ssr.pdf
Created by Independent Third Party: Yes
17022.4 4 - "1.5" Mechanical Seam" (R5)1.5” rib height, 16” wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.4 MECHANCIAL SEAM
ALUMINUM_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.4 MECHANCIAL SEAM
ALUMINUM_ssr.pdf
Created by Independent Third Party: Yes
17022.5 5 - "1 in. Nail Strip" (R5)1” rib height, 16” wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.5_1.0 NAILSTRIP_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.5_1.0 NAILSTRIP_ssr.pdf
Created by Independent Third Party: Yes
1/13/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvOQveeg%3d%3d 3/3
17022.6 6 - "1 in. Nail Strip" (R5)1” rib height, 16” wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.6 _1.0 NAIL STRIP_0.032
ALUM_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.6 _1.0 NAIL STRIP_0.032
ALUM_ssr.pdf
Created by Independent Third Party: Yes
17022.7 7 - "1.5 in. Nail Strip" (R5)1.5” rib height, 19” wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.7_1.5 Nail Strip 26GA_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.7_1.5 Nail Strip 26GA_ssr.pdf
Created by Independent Third Party: Yes
17022.8 8 - "EMAX Rib" (R5)29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 177022.8 EMAX Rib_ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 177022.8 EMAX Rib_ssr.pdf
Created by Independent Third Party: Yes
17022.9 9 - " PBR MAX" (R5)26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer’s installation instructions.
Installation Instructions
FL17022_R7_II_FL 17022.9 PBR RIB_ ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7_AE_FL 17022.9 PBR RIB_ ssr.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Product Report Manufacturer: Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
772 872-8034
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Lo ads METHOD 1 METHOD2 METHOD 3 METHOD4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF
ROW SPACING 16" o.c. 16" o.c. 8" o.c. 6" o.c.
FASTENER SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c.
FASTENER SIZE #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 152 7
UL 580-06 & 1897-041
TAS 125-0 3
05/02/14 Test Report D05893.0l-450-18
Test Report F3366.0l-450-18
Test Report D05893.02-450-18
12/18/15
0 7/22/14 ··'''""''''·' ,, ,,'�x.. 0. BO �V: ,,., Locke Bowden, P.E. does not have, not will acquire a finan cial in��l�-eili'; fqmJla11.V, �;�facturing or distributing products .. .. \,� ., l .:i',t:' • / / ,,. under this evaluation. :-'v • � • ' �Locke Bowden, P.E. is not owned, operated, or controlled by ai, co�parl'lprrnithJfKtur;,, ord.istributing products under this
report.
;�,1. (Mj·�
:: :f"': :•:: �,... .? � � /'·. . s" · :,"-i�ilo
-;,,C!<-;_ • .;:-l OH\0 � • • ·�J, "',, ,:s ,· •.•• • .... �{) .. ·
l,,: 10NAL t-\ ,.;,•l:itt::. 11\\\\•'
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12.*Design pressure margin of safety 2:1
See Fastener attachment specifications above
Fasten
r #9 × 1-1/2" Min. or #10 × 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Refer to Table "A" for Spacing Along Panel
Length
Nominal 12"
o.c.
Nominal 12"
o.c.
Panel
Overlap
Deck- 15/32" or greater
:Plywood, or
-Wood plank
Fasteners -
#9 × 1-1/2" Min. or
#10 × 1-1/2" Min. per Table "A" for Row
Spacing and Design Pressures
Hex Washer Head Wood Screws
Refer to Table "A"Deck:
- 15/32" or greater Plywood, or
- Wood plank
5-V Crimp Roof Panel
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference.
3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.