Loading...
HomeMy WebLinkAboutWS 17 - Truss Package6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0017 - Design Code: FBC2020/TPI2014 Wind Code: N/A Wind Speed: 165 mph Roof Load: 37.0 psf Design Program: MiTek 20/20 8.4 1 of 1 This package includes 21 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf Site Information: Lot/Block: 17 Customer Info: K Hovnanian Homes Project Name: WS0017 Model: Eden-A Subdivision: Waterstone Address: 5158 Armina Place, . State: FLCity: Fort Pierce Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: December 10,2020 Finn, Walter The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource (Lady Lake, FL). Truss Design Engineer's Name: Finn, Walter My license renewal date for the state of Florida is February 28, 2021. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. No.Seal#Truss Name 1 T22135789 CJ1 Date 12/10/202T22135790CJ312/10/203T22135791CJ512/10/204T22135792EJ512/10/205T22135793EJ712/10/206T22135794HJ512/10/207T22135795HJ712/10/208T22135796T0112/10/209T22135797T0212/10/2010T22135798T0312/10/2011T22135799T0412/10/2012T22135800T0512/10/2013T22135801T0612/10/2014T22135802T0712/10/20 No.Seal#Truss Name 15 T22135803 T08 Date 12/10/2016T22135804T0912/10/2017T22135805T1012/10/2018T22135806T1112/10/2019T22135807V0112/10/2020T22135808V0212/10/2021T22135809V0312/10/20 This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss CJ1 Truss Type Corner Jack Qty 10 Ply 1 Job Reference (optional) T22135789 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:01:57 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-qAiWV4iNSptzvQTG88AM_DSO6JPW3sVZCUMbFyyAPyO Scale = 1:6.5 1 2 3 4 2x4 ST1.5x8 STP 1-0-0 1-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-4-10-9-10-4-100-9-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.01 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=40(LC 12) Max Uplift 3=-8(LC 1), 2=-97(LC 12) Max Grav 3=18(LC 12), 2=125(LC 1), 4=18(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss CJ3 Truss Type Corner Jack Qty 10 Ply 1 Job Reference (optional) T22135790 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:01:57 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-qAiWV4iNSptzvQTG88AM_DSNvJNk3sVZCUMbFyyAPyO Scale = 1:10.8 1 2 5 3 4 2x4 ST1.5x8 STP 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-4-11-7-11-2-101-7-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=71(LC 12) Max Uplift 3=-32(LC 12), 2=-106(LC 12) Max Grav 3=54(LC 17), 2=187(LC 1), 4=52(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=106. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss CJ5 Truss Type Corner Jack Qty 6 Ply 1 Job Reference (optional) T22135791 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:01:58 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-IMGuiQj?D7?pXa2SirhbXR_UFjhvoJljR859nPyAPyN Scale = 1:15.8 1 2 5 6 3 4 2x4 ST1.5x8 STP 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.45 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=103(LC 12) Max Uplift 3=-77(LC 12), 2=-116(LC 12) Max Grav 3=114(LC 17), 2=253(LC 1), 4=92(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=116. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss EJ5 Truss Type Jack-Open Qty 2 Ply 1 Job Reference (optional) T22135792 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:01:58 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-IMGuiQj?D7?pXa2SirhbXR_UFjhvoJljR859nPyAPyN Scale = 1:14.9 1 2 5 6 3 4 2x4 ST1.5x8 STP 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.45 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=103(LC 12) Max Uplift 3=-77(LC 12), 2=-116(LC 12) Max Grav 3=114(LC 17), 2=253(LC 1), 4=92(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=116. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss EJ7 Truss Type Jack-Open Qty 21 Ply 1 Job Reference (optional) T22135793 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:01:59 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-mZqGwmkdzR7g8kceFZCq4eXcV6_iXm?sfnriKryAPyM Scale = 1:19.8 1 2 5 6 3 43x4 ST1.5x8 STP 7-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 0-4-13-3-12-10-103-3-15.00 12 Plate Offsets (X,Y)-- [2:0-0-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.48 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.10 -0.18 -0.00 (loc) 2-4 2-4 3 l/defl >773 >431 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=136(LC 12) Max Uplift 3=-103(LC 12), 2=-130(LC 12) Max Grav 3=159(LC 1), 2=324(LC 1), 4=121(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=103, 2=130. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss HJ5 Truss Type Diagonal Hip Girder Qty 2 Ply 1 Job Reference (optional) T22135794 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:00 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-ElOe75lFkkFXmuBqpGj3cs4oxWKiGDF0uRaGsHyAPyL Scale = 1:15.7 1 2 5 6 3 7 8 4 3x4 7-0-2 7-0-2 -1-5-0 1-5-0 7-0-2 7-0-2 0-4-12-4-133.54 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.63 0.50 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.17 -0.00 (loc) 2-4 2-4 3 l/defl >975 >470 n/a L/d 240 180 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-10-15, 4=Mechanical Max Horz 2=103(LC 8) Max Uplift 3=-94(LC 8), 2=-193(LC 8) Max Grav 3=153(LC 1), 2=315(LC 1), 4=118(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=193. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 78 lb up at 1-4-15, 78 lb up at 1-4-15, and 44 lb up at 4-2-15, and 44 lb up at 4-2-15 on top chord, and at 1-4-15, at 1-4-15, and at 4-2-15, and at 4-2-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 2-4=-20 Concentrated Loads (lb) Vert: 5=44(F=22, B=22) This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss HJ7 Truss Type Diagonal Hip Girder Qty 3 Ply 1 Job Reference (optional) T22135795 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:00 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-ElOe75lFkkFXmuBqpGj3cs4rjWK3G9l0uRaGsHyAPyL Scale = 1:20.6 1 2 3 7 6 8 9 10 4 11 12 13 52x4 3x4 3x4 2x4 5-2-9 5-2-9 9-10-1 4-7-8 -1-5-0 1-5-0 5-2-9 5-2-9 9-10-1 4-7-8 0-4-13-2-133.54 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.39 0.47 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.08 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-10-15, 5=Mechanical Max Horz 2=135(LC 8) Max Uplift 4=-82(LC 8), 2=-237(LC 8), 5=-87(LC 8) Max Grav 4=124(LC 1), 2=445(LC 1), 5=290(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-763/220 BOT CHORD 2-7=-290/702, 6-7=-290/702 WEBS 3-6=-747/308, 3-7=0/284 NOTES-(9) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5 except (jt=lb) 2=237. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 78 lb up at 1-4-15, 78 lb up at 1-4-15, 44 lb up at 4-2-15, 44 lb up at 4-2-15, and 38 lb down and 99 lb up at 7-0-14, and 38 lb down and 99 lb up at 7-0-14 on top chord, and at 1-4-15, at 1-4-15, at 4-2-15, at 4-2-15, and 36 lb down at 7-0-14, and 36 lb down at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 2-5=-20 Concentrated Loads (lb) Vert: 8=44(F=22, B=22) 10=-75(F=-38, B=-38) 13=-36(F=-18, B=-18) This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T01 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T22135796 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:01 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-ixy1KRmtV2OOO2m1N_EI93c1QwgP?f1975KpOkyAPyK Scale = 1:21.6 1 2 3 4 5 7 6 85x8 ST1.5x8 STP ST1.5x8 STP 4x6 3x4 3x4 2x4 3x4 5-0-0 5-0-0 7-0-0 2-0-0 12-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 7-0-0 2-0-0 12-0-0 5-0-0 0-4-12-5-10-4-12-5-15.00 12 Plate Offsets (X,Y)-- [3:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.33 0.40 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.02 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-8-0, 2=0-8-0 Max Horz 2=59(LC 7) Max Uplift 5=-192(LC 8), 2=-260(LC 8) Max Grav 5=590(LC 1), 2=657(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1055/324, 3-4=-959/351, 4-5=-1098/355 BOT CHORD 2-7=-243/911, 6-7=-240/920, 5-6=-272/951 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=192, 2=260. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 79 lb down and 97 lb up at 5-0-0, and 184 lb down and 219 lb up at 7-0-0 on top chord, and 113 lb down at 5-0-0, and 113 lb down at 6-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-54, 4-5=-54, 2-5=-20 Concentrated Loads (lb) Vert: 3=-60(F) 4=-137(F) 7=-69(F) 6=-69(F) This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T02 Truss Type Common Qty 3 Ply 1 Job Reference (optional) T22135797 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:02 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-A8VPYnmVGMWF?CLDxhlXhH9BwK1Hk69IMl3MwAyAPyJ Scale = 1:21.4 1 2 3 4 5 6 7 8 9 4x6 ST1.5x8 STP ST1.5x8 STP 3x4 3x4 2x4 6-0-0 6-0-0 12-0-0 6-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 12-0-0 6-0-0 0-4-12-10-10-4-15.00 12 Plate Offsets (X,Y)-- [2:0-1-10,Edge], [4:0-1-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.41 0.36 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.04 -0.07 0.01 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-8-12 oc bracing. REACTIONS. (size)4=0-8-0, 2=0-8-0 Max Horz 2=69(LC 11) Max Uplift 4=-133(LC 12), 2=-209(LC 12) Max Grav 4=415(LC 1), 2=496(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-650/434, 3-4=-649/449 BOT CHORD 2-5=-317/536, 4-5=-317/536 WEBS 3-5=-22/266 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-0-0, Exterior(2R) 6-0-0 to 9-0-0, Interior(1) 9-0-0 to 11-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=133, 2=209. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T03 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T22135798 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:03 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-eK3nl7n71fe6dLwPUPHmEUiEukHoTRPSaPpwTcyAPyI Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 5x8 ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 3x6 5x8 3x4 3x6 2x4 3x4 3x4 6x8 3x6 3x4 2x4 3x6 3x4 7-0-0 7-0-0 11-6-3 4-6-3 11-8-0 0-1-13 16-8-0 5-0-0 16-9-4 0-1-4 22-4-0 5-6-12 28-0-0 5-8-0 35-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 14-0-0 7-0-0 21-0-0 7-0-0 28-0-0 7-0-0 35-0-0 7-0-0 36-0-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [3:0-5-12,0-2-8], [7:0-5-12,0-2-8], [8:0-2-0,Edge], [14:0-1-13,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.73 0.61 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.08 -0.16 0.04 (loc) 8-10 8-10 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 *Except* 3-5: 2x4 SP No.1, 5-7: 2x4 SP M 31 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-13 REACTIONS.All bearings 0-8-0. (lb) - Max Horz 2=80(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-163(LC 8), 15=-111(LC 8), 13=-1168(LC 8), 8=-493(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=406(LC 13), 15=510(LC 13), 13=2678(LC 18), 8=1049(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-380/58, 3-4=-124/454, 4-6=-575/1363, 6-7=-1038/529, 7-8=-1946/875 BOT CHORD 2-16=0/340, 15-16=0/347, 13-15=-572/246, 12-13=-353/755, 10-12=-712/1741, 8-10=-710/1715 WEBS 3-15=-750/263, 4-15=-109/332, 4-13=-1203/682, 6-13=-2579/1300, 6-12=-95/786, 7-12=-795/361, 7-10=-56/644 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 163 lb uplift at joint 2, 111 lb uplift at joint 15, 1168 lb uplift at joint 13 and 493 lb uplift at joint 8. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 105 lb down and 125 lb up at 13-0-12, 105 lb down and 125 lb up at 15-0-12, 105 lb down and 125 lb up at 17-0-12, 105 lb down and 125 lb up at 17-11-4, 105 lb down and 125 lb up at 19-11-4, 105 lb down and 125 lb up at 21-11-4, 105 lb down and 125 lb up at 23-11-4, and 105 lb down and 125 lb up at 25-11-4, and 200 lb down and 234 lb up at 28-0-0 on top chord, and 81 lb down at 13-0-12, 81 lb down at 15-0-12 , 81 lb down at 17-0-12, 81 lb down at 17-11-4, 81 lb down at 19-11-4, 81 lb down at 21-11-4, 81 lb down at 23-11-4, and 81 lb down at 25-11-4, and 320 lb down and 130 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T03 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T22135798 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:03 2020 Page 2 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-eK3nl7n71fe6dLwPUPHmEUiEukHoTRPSaPpwTcyAPyI 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54, 2-8=-20 Concentrated Loads (lb) Vert: 7=-153(F) 13=-58(F) 10=-320(F) 17=-105(F) 18=-105(F) 19=-105(F) 20=-105(F) 21=-105(F) 22=-105(F) 23=-105(F) 24=-105(F) 25=-58(F) 26=-58(F) 27=-58(F) 28=-58(F) 29=-58(F) 30=-58(F) 31=-58(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T04 Truss Type Hip Qty 1 Ply 1 Job Reference (optional) T22135799 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:04 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-6Wd9zTomozmzFVVc26o?niEXY7afCtYbp3YT?2yAPyH Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 4x6 ST1.5x8 STP ST1.5x8 STP 3x6 4x6 3x6 4x6 3x8 2x4 3x4 3x4 3x4 3x8 2x4 4x6 3x6 9-0-0 9-0-0 17-6-0 8-6-0 26-0-0 8-6-0 35-0-0 9-0-0 -1-0-0 1-0-0 4-9-14 4-9-14 9-0-0 4-2-2 14-8-0 5-8-0 20-4-0 5-8-0 26-0-0 5-8-0 30-2-2 4-2-2 35-0-0 4-9-14 36-0-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.40 0.94 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.47 0.15 (loc) 14 14-16 10 l/defl >999 >875 n/a L/d 240 180 n/a PLATES MT20 Weight: 167 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 10=0-8-0 Max Horz 2=100(LC 11) Max Uplift 2=-483(LC 12), 10=-483(LC 12) Max Grav 2=1342(LC 1), 10=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2661/1054, 3-4=-2434/934, 4-5=-2229/905, 5-7=-2866/1127, 7-8=-2229/905, 8-9=-2434/934, 9-10=-2661/1053 BOT CHORD 2-16=-889/2393, 14-16=-969/2806, 12-14=-962/2806, 10-12=-899/2393 WEBS 4-16=-188/664, 5-16=-783/307, 7-12=-783/307, 8-12=-188/664 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 13-2-15, Interior(1) 13-2-15 to 26-0-0, Exterior(2R) 26-0-0 to 30-4-6, Interior(1) 30-4-6 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T05 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T22135800 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:05 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-bjBXAppOZHuqsf4ocqJEJvngDX_zxQ0l2jI0XVyAPyG Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 23 24 5x8 ST1.5x8 STP ST1.5x8 STP 5x8 3x6 3x6 3x4 2x4 3x4 3x8 2x4 3x4 3x4 2x4 3x6 3x6 5-9-14 5-9-14 11-0-0 5-2-2 17-6-0 6-6-0 24-0-0 6-6-0 29-2-2 5-2-2 35-0-0 5-9-14 -1-0-0 1-0-0 5-9-14 5-9-14 11-0-0 5-2-2 17-6-0 6-6-0 24-0-0 6-6-0 29-2-2 5-2-2 35-0-0 5-9-14 36-0-0 1-0-0 0-4-14-11-10-4-14-11-15.00 12 Plate Offsets (X,Y)-- [4:0-5-12,0-2-8], [6:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.68 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.38 0.13 (loc) 13 13-15 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 175 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-3-10 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-120(LC 10) Max Uplift 2=-483(LC 12), 8=-483(LC 12) Max Grav 2=1342(LC 1), 8=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2711/1028, 3-4=-2260/903, 4-5=-2408/1011, 5-6=-2408/1011, 6-7=-2260/903, 7-8=-2711/1028 BOT CHORD 2-16=-861/2423, 15-16=-861/2423, 13-15=-653/2042, 11-13=-663/2042, 10-11=-871/2423, 8-10=-871/2423 WEBS 3-15=-441/231, 4-15=-65/367, 4-13=-179/568, 5-13=-398/242, 6-13=-179/568, 6-11=-65/367, 7-11=-442/231 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2R) 11-0-0 to 15-2-15, Interior(1) 15-2-15 to 24-0-0, Exterior(2R) 24-0-0 to 28-2-15, Interior(1) 28-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T06 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T22135801 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:06 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-3vlwO9p0Ka0hUpf_AXqTs7KrbxGxgoAuGN1a3xyAPyF Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 22 23 4x6 ST1.5x8 STP ST1.5x8 STP 4x6 3x6 4x6 3x4 2x4 3x8 3x4 3x8 3x4 2x4 4x6 3x6 6-9-14 6-9-14 13-0-0 6-2-2 22-0-0 9-0-0 28-2-2 6-2-2 35-0-0 6-9-14 -1-0-0 1-0-0 6-9-14 6-9-14 13-0-0 6-2-2 17-6-0 4-6-0 22-0-0 4-6-0 28-2-2 6-2-2 35-0-0 6-9-14 36-0-0 1-0-0 0-4-15-9-10-4-15-9-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.55 0.95 0.61 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.34 -0.59 0.14 (loc) 12-13 12-13 8 l/defl >999 >693 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 8=0-8-0 Max Horz 2=-140(LC 10) Max Uplift 2=-483(LC 12), 8=-483(LC 12) Max Grav 2=1490(LC 17), 8=1490(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2974/1025, 3-4=-2317/856, 4-5=-2109/840, 5-6=-2109/840, 6-7=-2317/856, 7-8=-2974/1025 BOT CHORD 2-15=-851/2768, 13-15=-851/2768, 12-13=-652/2209, 10-12=-861/2663, 8-10=-861/2663 WEBS 3-13=-676/297, 4-13=-150/653, 5-13=-289/111, 5-12=-289/111, 6-12=-150/653, 7-12=-676/297 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2R) 13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0, Exterior(2R) 22-0-0 to 26-2-15, Interior(1) 26-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T07 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T22135802 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:07 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-X5JIbVqe5u8Y6zEBjELiOKszrLdIPAw1V1n7cNyAPyE Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 3x6 ST1.5x8 STP ST1.5x8 STP 5x8 4x6 3x6 3x6 4x6 3x4 2x4 3x4 3x8 3x4 2x4 4x6 3x6 7-9-14 7-9-14 15-0-0 7-2-2 20-0-0 5-0-0 27-2-2 7-2-2 35-0-0 7-9-14 -1-0-0 1-0-0 7-9-14 7-9-14 15-0-0 7-2-2 20-0-0 5-0-0 27-2-2 7-2-2 35-0-0 7-9-14 36-0-0 1-0-0 0-4-16-7-10-4-16-7-15.00 12 Plate Offsets (X,Y)-- [5:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.71 0.82 0.90 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.35 0.13 (loc) 13-14 14-16 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-3-7 oc bracing. REACTIONS. (size)2=0-8-0, 9=0-8-0 Max Horz 2=-160(LC 10) Max Uplift 2=-483(LC 12), 9=-483(LC 12) Max Grav 2=1342(LC 1), 9=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2655/1008, 3-5=-1932/811, 5-6=-1715/803, 6-8=-1933/811, 8-9=-2655/1008 BOT CHORD 2-16=-828/2365, 14-16=-828/2365, 13-14=-514/1714, 11-13=-838/2365, 9-11=-838/2365 WEBS 3-16=0/329, 3-14=-733/347, 5-14=-106/445, 6-13=-113/445, 8-13=-732/347, 8-11=0/328 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2R) 15-0-0 to 19-2-15, Interior(1) 19-2-15 to 20-0-0, Exterior(2R) 20-0-0 to 24-2-15, Interior(1) 24-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T08 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T22135803 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:08 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-?HtgoqrGsBGPj7oNHysxxYPDGlxG8hZBkhWh8qyAPyD Scale = 1:64.8 1 2 3 4 5 6 7 8 9 10 11 12 13 18 17 16 15 14 19 20 21 22 ST1.5x8 STP ST1.5x8 STP 3x4 2x4 3x4 3x8 3x4 3x4 2x4 8-9-14 8-9-14 17-0-0 8-2-2 17-6-0 0-6-0 18-0-0 0-6-0 26-2-2 8-2-2 35-0-0 8-9-14 -1-0-0 1-0-0 6-1-3 6-1-3 12-3-13 6-2-10 17-0-0 4-8-3 17-6-0 0-6-0 18-0-0 0-6-0 22-8-3 4-8-3 28-10-13 6-2-10 35-0-0 6-1-3 36-0-0 1-0-0 0-4-17-5-10-4-17-5-15.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-2-4], [8:0-3-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.42 0.90 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.38 0.12 (loc) 16 16-18 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-4-13 oc bracing. REACTIONS. (size)2=0-8-0, 12=0-8-0 Max Horz 2=180(LC 11) Max Uplift 2=-483(LC 12), 12=-483(LC 12) Max Grav 2=1342(LC 1), 12=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2663/999, 3-5=-2429/928, 5-6=-1695/734, 6-7=-1512/704, 7-8=-1512/704, 8-9=-1695/734, 9-11=-2429/928, 11-12=-2663/999 BOT CHORD 2-18=-832/2396, 16-18=-608/1926, 14-16=-618/1926, 12-14=-843/2396 WEBS 3-18=-299/216, 5-18=-112/493, 5-16=-599/320, 9-16=-599/320, 9-14=-112/493, 11-14=-299/216, 7-16=-381/998 NOTES-(9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2E) 17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 12. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T09 Truss Type Common Qty 12 Ply 1 Job Reference (optional) T22135804 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:09 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-TUQ20AsudVOGLGNZrfNAUlyN48HFt8eKzLGEgGyAPyC Scale = 1:62.4 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 3x6 ST1.5x8 STP ST1.5x8 STP 4x6 3x6 3x6 3x6 3x8 3x4 3x4 2x4 3x4 3x4 2x4 3x6 3x6 8-9-14 8-9-14 17-6-0 8-8-2 25-11-2 8-5-2 35-0-0 9-0-14 -1-0-0 1-0-0 6-1-2 6-1-2 12-3-12 6-2-10 17-6-0 5-2-4 22-8-4 5-2-4 28-8-13 6-0-9 35-0-0 6-3-3 36-0-0 1-0-0 0-4-17-7-90-4-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.47 0.92 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.38 0.12 (loc) 14 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-8-0, 10=0-8-0 Max Horz 2=185(LC 11) Max Uplift 2=-483(LC 12), 10=-483(LC 12) Max Grav 2=1342(LC 1), 10=1342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2663/1003, 3-5=-2429/933, 5-6=-1693/747, 6-7=-1692/747, 7-9=-2411/929, 9-10=-2650/999 BOT CHORD 2-16=-840/2395, 14-16=-619/1929, 12-14=-622/1930, 10-12=-839/2383 WEBS 6-14=-387/1010, 7-14=-610/321, 7-12=-108/484, 9-12=-301/213, 5-14=-609/323, 5-16=-109/493, 3-16=-297/213 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-6-0, Exterior(2R) 17-6-0 to 20-6-0, Interior(1) 20-6-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T10 Truss Type Hip Structural Gable Qty 1 Ply 1 Job Reference (optional) T22135805 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:10 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-xg_QDWsWOpW6zQylPNvP0zUUAYdBcXyUB??nCiyAPyB Scale = 1:62.5 1 2 3 4 5 6 7 8 9 10 11 17 15 14 13 12 18 19 20 21 22 23 16 4x6 ST1.5x8 STP ST1.5x8 STP 3x6 4x6 3x8 3x6 6x8 2x4 3x6 3x4 3x6 6x8 2x4 3x6 3x8 9-0-0 9-0-0 10-0-0 1-0-0 17-6-0 7-6-0 26-0-0 8-6-0 35-0-0 9-0-0 -1-0-0 1-0-0 4-9-14 4-9-14 9-0-0 4-2-2 14-8-0 5-8-0 20-4-0 5-8-0 26-0-0 5-8-0 30-2-2 4-2-2 35-0-0 4-9-14 36-0-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-2], [10:0-0-0,0-0-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.71 0.93 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.28 0.04 (loc) 2-17 10-12 10 l/defl >821 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 167 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 6-8,4-6: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-14 oc purlins. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-17 REACTIONS.All bearings 10-0-0 except (jt=length) 10=0-8-0, 16=0-8-0. (lb) - Max Horz 2=-100(LC 30) Max Uplift All uplift 100 lb or less at joint(s) 16 except 2=-1182(LC 31), 17=-1017(LC 33), 10=-1863(LC 34) Max Grav All reactions 250 lb or less at joint(s) 16 except 2=1143(LC 30), 17=1766(LC 1), 10=2003(LC 31) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2973/3147, 3-4=-1910/2216, 4-5=-1275/1608, 5-7=-1770/1509, 7-8=-2192/1798, 8-9=-3518/2940, 9-10=-4646/4245 BOT CHORD 2-17=-2981/2787, 16-17=-1254/1437, 14-16=-957/1140, 12-14=-2415/2838, 10-12=-3782/4316 WEBS 3-17=-389/305, 4-17=-590/429, 5-17=-2104/1617, 5-14=-919/1242, 7-14=-1048/977, 7-12=-1012/1131, 8-12=-542/729, 9-12=-353/323 NOTES-(9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 13-2-15, Interior(1) 13-2-15 to 26-0-0, Exterior(2R) 26-0-0 to 30-4-6, Interior(1) 30-4-6 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb) 2=1182, 17=1017, 10=1863. 8) This truss has been designed for a total drag load of 250 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 35-0-0 for 250.0 plf. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T11 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T22135806 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:11 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-PsYoRst996ezaaXyy4QeZA1bmy_pL0sdQflLl8yAPyA Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4x10 MT20HS ST1.5x8 STP ST1.5x8 STP ST1.5x8 STP 3x6 5x6 3x4 3x6 2x4 5x8 5x6 3x4 3x4 5x6 WB 3x6 2x4 6x8 7-0-0 7-0-0 10-4-0 3-4-0 19-1-8 8-9-8 28-0-0 8-10-8 35-0-0 7-0-0 -1-0-0 1-0-0 3-8-11 3-8-11 7-0-0 3-3-5 10-4-0 3-4-0 13-9-2 3-5-2 21-2-14 7-5-11 28-0-0 6-9-2 35-0-0 7-0-0 36-0-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge], [3:0-7-0,0-2-4], [8:0-3-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2020/TPI2014 CSI. TC BC WB Matrix-SH 0.97 0.85 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.48 0.04 (loc) 11-13 11-13 9 l/defl >999 >604 n/a L/d 240 180 n/a PLATES MT20 MT20HS Weight: 159 lb FT = 20% GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 3-6: 2x4 SP M 31 BOT CHORD 2x4 SP No.1 *Except* 12-14: 2x4 SP M 31 WEBS 2x4 SP No.3 *Except* 5-13: 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-5-7 oc bracing. WEBS 1 Row at midpt 5-15 REACTIONS. (size)2=0-8-0, 9=0-8-0, 15=0-8-0 Max Horz 2=-80(LC 6) Max Uplift 2=-361(LC 18), 9=-574(LC 8), 15=-1317(LC 8) Max Grav 2=270(LC 6), 9=1502(LC 18), 15=3859(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-364/1209, 3-4=-794/2407, 4-5=-794/2407, 5-7=-2295/766, 7-8=-2792/1019, 8-9=-3092/1062 BOT CHORD 2-16=-1085/404, 15-16=-1066/400, 11-13=-981/2879, 9-11=-879/2760 WEBS 3-16=-76/450, 5-15=-3062/1215, 5-13=-732/2699, 7-13=-1010/605, 8-11=-63/736, 4-15=-275/163, 3-15=-1914/710 NOTES-(11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=361, 9=574, 15=1317. Continued on page 2 This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss T11 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T22135806 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:11 2020 Page 2 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-PsYoRst996ezaaXyy4QeZA1bmy_pL0sdQflLl8yAPyA NOTES-(11) 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 122 lb up at 7-0-0, 105 lb down and 118 lb up at 9-0-12, 105 lb down and 118 lb up at 11-0-12, 105 lb down and 118 lb up at 13-0-12, 105 lb down and 118 lb up at 15-0-12, 105 lb down and 118 lb up at 17-0-12, 105 lb down and 118 lb up at 17-11-4, 105 lb down and 118 lb up at 19-11-4, 105 lb down and 118 lb up at 21-11-4, 105 lb down and 118 lb up at 23-11-4, and 105 lb down and 118 lb up at 25-11-4, and 200 lb down and 232 lb up at 28-0-0 on top chord, and 320 lb down and 115 lb up at 7-0-0, 81 lb down at 9-0-12, 81 lb down at 11-0-12, 81 lb down at 13-0-12, 81 lb down at 15-0-12, 81 lb down at 17-0-12, 81 lb down at 17-11-4, 81 lb down at 19-11-4, 81 lb down at 21-11-4, 81 lb down at 23-11-4, and 81 lb down at 25-11-4, and 320 lb down and 115 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-10=-54, 2-9=-20 Concentrated Loads (lb) Vert: 3=-105(B) 8=-153(B) 16=-320(B) 11=-320(B) 17=-105(B) 18=-105(B) 19=-105(B) 20=-105(B) 21=-105(B) 22=-105(B) 23=-105(B) 24=-105(B) 25=-105(B) 26=-105(B) 27=-58(B) 28=-58(B) 29=-58(B) 30=-58(B) 31=-58(B) 32=-58(B) 33=-58(B) 34=-58(B) 35=-58(B) 36=-58(B) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss V01 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T22135807 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:12 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-t36BeCunwQmqCk68Woxt5OaxjMWT4dsnfJUuHbyAPy9 Scale = 1:15.6 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 6-0-0 6-0-0 0-0-42-6-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.11 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-11-6, 4=5-11-6, 5=5-11-6 Max Horz 1=104(LC 9) Max Uplift 1=-3(LC 13), 4=-30(LC 9), 5=-100(LC 12) Max Grav 1=60(LC 18), 4=86(LC 17), 5=238(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-177/295 NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss V02 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T22135808 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:12 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-t36BeCunwQmqCk68Woxt5OavOMVK4eDnfJUuHbyAPy9 Scale = 1:11.1 1 2 3 2x4 2x4 2x4 4-0-0 4-0-0 0-0-41-8-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.34 0.19 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-11-6, 3=3-11-6 Max Horz 1=63(LC 9) Max Uplift 1=-36(LC 12), 3=-39(LC 12) Max Grav 1=115(LC 1), 3=116(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0017 Truss V03 Truss Type Valley Qty 1 Ply 1 Job Reference (optional) T22135809 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Dec 10 09:02:13 2020 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472, ID:ts67lOCZ21Eq4xvrhYAIX3yhPJt-MFgZsYvPgkuhquhK4VS6eb699mtAp5SwtzESp1yAPy8 Scale = 1:6.9 1 2 3 2x4 4x6 2-0-0 2-0-0 0-0-40-10-05.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2020/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=1-11-6, 3=1-11-6 Max Horz 1=23(LC 9) Max Uplift 1=-13(LC 12), 3=-14(LC 12) Max Grav 1=41(LC 1), 3=41(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Finn, Walter, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. December 10,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths