HomeMy WebLinkAboutEnergy Calcs - HerdAir Calcs, LLC Load Short Form
House
Air Calcs, LLC
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
For: Herd Residence, Air Conditioning Unlimited, LLC
5194 Tree Top Trail, Port St Lucie, FL 34951
Htg Clg
Outside db (°F)
41
90
Inside db (°F)
70
75
Design TD (°F)
29
15
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (gr/Ib)
2
57
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
11.1
kW
37834
Btuh
27
°F
1283
cfm
0.035
cfm/Btuh
0.70
in H2O
Infiltration
Method
Shielding / stories
Pressure /AVF
Blower door
3 (partial) / 1
50 Pa / 0 cfm
COOLING EQUIPMENT
Make Lennox
Trade LENNOX
Cond ML14XC1-041-230A**
Coil CBA27UHE-048-230*++TDR
AHRI ref 10259425
Efficiency
13.0 EER, 16 SEER
Sensible cooling
26950
Btuh
Latent cool i ng
11550
Btuh
Total cooling
38500
Btuh
Actual airflow
1283
cfm
Airflowfactor
0.055
cfm/Btuh
Static pressure
0.70
in H2O
Load sensible heat ratio
0.70
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
CIgAVF
(cfm)
Bath 2
39
174
97
6
5
Bath 4
79
1603
569
56
31
Bed 2
218
5203
2214
182
121
Bed 3
156
1699
1512
59
83
Bed 4
254
5395
3777
189
206
Dining Room
102
1777
805
62
44
Great Room
436
6285
5060
220
277
Kitchen
217
721
2903
25
159
Laundry
74
213
710
7
39
M Bath
126
1938
596
68
33
M Hall
54
0
0
0
0
Master Bedroom
230
4700
2462
164
135
Mud Room
62
1400
352
49
19
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoft"
2021-Jan-04 11:03:44
A .e • - -aw=v —— Right-Sute@universal 2021 21.0.02 RSU27054
ACCP. Page 1
...cumerrts\WrightsoftHVAC\5194TreeTopTrail.rup CaIc=MJ8 Front Door faces: S
Hall
63
0
0
0
0
Sitting Room
138
1287
912
45
50
Storage
30
609
142
21
8
WC/Tub
39
655
238
23
13
WIC
60
390
173
14
9
WIC 3
36
66
51
2
3
WIC 4
48
866
312
30
17
Wtr Clst
27
633
221
22
12
House d
2524
36678
23481
1283
1283
Other equip loads
2000
1062
Equip. @ 0.95 RSM
23414
Latent cool i ng
10416
TOTALS ' 2524 ' 38678 ' 33830 ' 1283 ' 1283
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoft"
2021-Jarr04 11:03:44
A A I.Ik- I 1-k,I,- -naw,v<om,a y Right-Sute®Uriversal2021 21.0.02 RSU27054
ACCP. Page 2
...cumerrts\WrightsoftHVAC\5194TreeTopTrail.rup CaIc=MJ8 Front Door faces: S
Air Calcs, LLC Building Analysis
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.00m
For:
Location:
St Lucie Co Intl, FL, US
Elevation: 26 ft
Latitude: 28 °N
Outdoor:
Dry bulb (°F)
Daily range (°F)
Wet bulb (°F)
Wind speed (mph)
Herd Residence, Air Conditioning Unlimited, LLC
5194 Tree Top Trail, Port St Lucie, FL 34951
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
Indoor:
Heating
Cooling
Indoor temperature (°F)
70
75
Design TD (°F)
29
15
Relative humidity (%)
30
50
Heating Cooling
Moisture difference (grAb)
2.4
56.9
41 90
Infiltration:
- 15 (L )
Method
Blower door
77
Shielding / stories
3 (partial) / 1
15.0 7.5
Pressure /AVF
50 Pa / 0 cfm
Component
Btuh/ft2
Btuh
%of load
Walls
3.1
8260
21.4
Glazing
8.6
3284
8.5
Doors
0
0
0
Ceilings
1.6
4004
10.4
Floors
3.5
8862
22.9
Infiltration
2.7
7237
18.7
Ducts
5030
13.0
Piping
0
0
Humidification
0
0
Ventilation
2000
5.2
Adjustments
0
Total
38678
1 100.0
Component
Btuh/ft2
Btuh
% of load
Walls
1.9
4995
20.4
Glazing
9.6
3656
14.9
Doors
0
0
0
Ceilings
1.2
3085
12.6
Floors
0
0
0
Infiltration
0.8
2155
8.8
Ducts
3339
13.6
Ventilation
1062
4.3
Internal gains
6250
25.5
Blower
0
0
Adjustments
0
Total
24543
100.0
Latent Cooling Load =10416 Btuh
Overall U-value = 0.214 Btuh/ft2-°F
Data entries checked.
Glazing
Ventilation
!rnal Gains
_ -pp- wrightsoft- 2021-Jan-0411:03:44
MCA M, r • dr, -.. Right -Suite@ Universal 2021 21.0.02 RSU27054 Page 1
cuments\WrightsoftHVAC\5194TreeTopTrail.rup Calc=MJ8 Front Door faces: S
Air Calcs, LLC Component Constructions
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
For:
Location:
St Lucie Co Intl, FL, US
Elevation: 26 ft
Latitude: 28°N
Outdoor:
Dry bulb (°F)
Daily range (°F)
Wet bulb (°F)
Wind speed (mph)
Herd Residence, Air Conditioning Unlimited, LLC
5194 Tree Top Trail, Port St Lucie, FL 34951
Indoor:
Indoor temperature (°F)
Design TD (°F)
Relative humidity (%)
Heating Cooling
Moisture difference (gr/lb)
41 90
Infiltration:
- 15 (L )
Method
77
Shielding / stories
15.0 7.5
Pressure /AVF
Construction descriptions
or
Area
U value
ft,
Btuh/ft"F
Walls
Blk Wall, Stuc Ext, R-4.1 Ext Bd Ins, 8" Thk, 1/2" Gyp Bd Int Fnsh
n
332
0.109
e
642
0.109
s
563
0.109
w
742
0.109
all
2280
0.109
Partitions
Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2N4" Wd 367 0.101
Frm, 16" OC Stud
Windows
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.21); n
4 0.250
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (1.2 ft Wndow ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.21); n
6 0.250
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (1.2 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19); n
30 0.290
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.19); n
108 0.310
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (9 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Low-e; NFRC rated (SHGC=0.19); n
20 0.310
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (6.7 ft Wndow ht, 1.5 ft sep.); 8 ft head ht
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
Heating Cooling
70
75
29
15
30
50
2.4
56.9
Blower door
3 (partial) / 1
50 Pa / 0 cfm
Insul R
Htg HTM
Loss Clg HTM
Gain
ftz°F/Btuh
Btuh/ft'
Btuh
Btuh/ft'
Btuh
5.1
3.15
1047
2.02
670
5.1
3.15
2023
2.02
1294
5.1
3.15
1774
2.02
1135
5.1
3.15
2338
2.02
1496
5.1
3.15
7183
2.02
4594
11.0
2.94
1077
1.09
401
0
7.25
26
6.47
23
0
7.25
44
6.47
39
0
8.41
252
6.74
202
0
8.99
971
7.02
758
0
8.99
181
7.02
141
�- wrightsoft, 2021-Jarr0411:03:44
.M.CAM„ek•,de, •,- „a,n=-av o, Na„ Right-SUte@Universal 2021 21.0.02 RSU27054 Page 1
cumerds\WrightoftHVAC\5194TreeTopTrail.rup Calc=MJ8 FrontDoorfaces: S
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.19);
a 12 0.290
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (4 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.19);
a 18 0.290
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 9 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.21);
s 12 0.250
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (2 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.19);
s 54 0.290
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
w 30 0.290
grass (0.23); 1.4 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
w 18 0.290
all 102 0.290
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.19);
s 30 0.290
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 5.3 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
Impact, Clear, Lowe: Impact, Clear, Lowe; NFRC rated (SHGC=0.19);
s 40 0.310
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (6.7 ft window ht, 1.5 ft sep.); 8 ft head ht
Doors
(none)
Ceilings
Attic, Shngl Roof, R-20 Roof Deck Ins, 112" Gyp Bd 2524 0.405
Floors
DftFlor: On Grade Depth, Carpet 108 0.989
DftFlor: On Grade Depth, Tile Flr Fnsh 201 0.989
wrightsoft®
Rig1t-Sute®Urrversa1202121.0.02RSU27054
...amends\WrigfisoftHVAC\5194Tree Top Trail.rrp Calc=MJ8 FrordDoorfaces: S
0 8.41
101
20.3
244
0 8.41
151
8.80
158
0 7.25
87
8.47
102
0 8.41
454
8.74
472
0 8.41
252
20.3
610
0 8.41
151
20.3
366
0 8.41
858
14.2
1449
0 8.41
252
8.74
262
0 8.99
361
6.91
278
21.0 1.59 4004 1.22 3085
0 28.7 3098 0 0
0 28.7 5765 0 0
2021-Jarr04 11:03:44
Page 2
Pro ect Summa Job:
Air Calcs, LLC 1 rY Dec Date: Dec 30, 2020
House By: Vicki Lynne Nisa
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
For: Herd Residence, Air Conditioning Unlimited, LLC
5194 Tree Top Trail, Port St Lucie, FL 34951
Notes:
Weather: St Lucie Co Intl, FL, US
Winter Design Conditions
Outside db
Inside db
Design TD
Summer Design Conditions
41 °F Outside db
70 °F Inside db
29 °F Design TD
Daily range
Relative humidity
Moisture difference
Heating Summary
Structure 31648 Btuh
Ducts 5030 Btuh
Central vent (63 cfm) 2000 Btuh
Outside air
Humidification
Piping
Equipment load
Infiltration
Method
Shielding / stories
Pressure /AVF
0 Btuh
0 Btuh
38678 Btuh
Blower door
3 (ppartial) / 1
50 (partial)
0 cfm
Heating Cooling
Area (ft2)
2524
2524
Volume (ft3)
25690
25690
Airchanges/hour
0.53
0.30
Equiv.AVF (cfm)
227
127
Heating Equipment
Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
11.1 kW
37834 Btuh
27 °F
1283 cfrn
0.035 cfi71/Btuh
0.70 in H2O
90 °F
75 °F
15 °F
L
50 %
57 gr/lb
Sensible Cooling Equipment Load Sizing
Structure 20142 Btuh
Ducts 3339 Btuh
Central vent (63 cfm) 1062 Btuh
Outside air
Blower 0 Btuh
Use manufacturer's data
n
Rate/swin multipplier
Equipmen1sensibleload
0.95
23414 Btuh
Latent Cooling Equipment Load Sizing
Structure
5921 Btuh
Ducts
2071 Btuh
Central vent (63 cfm)
2424 Btuh
Outside air
Equipment latent load
10416 Btuh
Equipment Total Load (Sen+Lat)
33830 Btuh
Req. total capacity at 0.70 SHR
2.8 ton
Cooling Equipment Summary
Make Lennox
Trade LENNOX
Cond ML14XC1-041-230A**
Coil CBA27UHE-048-230*++TDR
AHRI ref 10259425
Efficiency
13.0 EER, 16 SEER
Sensible cooling
26950
Btuh
Latent cool i ng
11550
Btuh
Total cooling
38500
Btuh
Actual airflow
1283
cfm
Airflowfactor
0.055
cfm/Btuh
Static pressure
0.70
in H2O
Load sensible heat ratio
0.70
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
w rig htsoft`a 2021-Jan-04 11:03:44
Right-Suite(D Universal 2021 21.0.02 RSU27054 Page 1
.4CCA g
...cumer><s\WrigtisoftHVAC\5194TreeTopTrail.rup CaIc=MJ8 From Door faces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
House
Bath 2
2
Exposed wall
309.0 ft
0 ft
3
Room height
10.2 ft d
9.4 ft heat/000l
4
Room dimensions
6.5 x 6.0 ft
5
Room area
2524.0 ft2
39.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Bluh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Low-e
Impact, Clear, Low-e
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
500
4
6
332
0
0
1047
26
44
670
23
39
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Low-e
Impact, Clear, Low-e
0.290
0.310
n
n
8.41
8.99
6.74
7.02
30
108
0
0
252
971
202
758
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.310
n
8.99
7.02
20
0
181
141
0
0
0
0
W
G
Blk Wall, StucExt,
Impact, Clear, Low-e
0.109
0.290
e
a
3.15
8.41
2.02
20.34
672
12
642
0
2023
101
1294
244
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
18
699
18
563
151
1774
158
1135
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.250
s
7.25
8.47
12
12
87
102
0
0
0
0
Impact, Clear, Low-e
0.290
s
8.41
8.74
54
54
454
472
0
0
0
0
G
Impact, Clear, Low-e
0.290
s
8.41
8.74
30
30
252
262
0
0
0
0
Impact, Clear, Low-e
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
40
790
40
742
361
2338
278
1496
0
0
0
0
0
0
0
0
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
30
18
0
0
252
151
610
366
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
367
367
1077
401
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
2524
2524
4004
3085
39
39
62
48
F
DftRor
0.989
28.68
0.00
851
108
3098
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
1673
201
5765
0
39
0
0
0
6
c) AED excursion
0
-1
Envelope loss/gain
24411
11736
62
47
12
a) Infiltration
7237
2155
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Ocwpants@ 230
5
1150
0
0
Appliancestother
5100
0
Subtotal (lines 6 to 13)
31648
20142
62
47
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
88
36
14
Subtotal
31648
20142
150
83
15
Dudloads
16%
17%
5030
3339
16%
17%
24
14
Total room load
36678
23481
174
97
Air required (dm)
1283
12831
6
5
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft
w°-""""" 1-l'-, Right-Suite®Universal2021 21.0.02 RSU27054
,4CC,K Page 1
moments\WrightsoftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
Bath 4
Bed 2
2
Exposed wall
15.0 ft
47.5 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/000l
4
Room dimensions
1.0 x 78.8 ft
1.0 x 217.5 ft
5
Room area
78.8 ft2
217.5 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
14
0
0
14
0
0
44
0
0
28
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
a
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
141
0
141
0
444
0
284
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
14
0
14
0
44
0
28
0
164
0
146
0
462
0
295
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
18
18
151
157
G
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
113
0
113
0
355
0
227
0
141
0
141
0
444
0
284
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
79
79
125
96
218
218
345
266
F
DflHlor
0.989
28.68
0.00
0
0
0
0
218
48
1362
0
F
DflHlor
0.989
28.68
0.00
79
15
430
0
0
0
0
0
6
c) AED excursion
-7
-26
Envelope loss/gain
999
374
3209
1261
12
a) Infiltration
383
114
1214
362
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
0
250
Subtotal (lines 6 to 13)
1383
488
4423
1872
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
66
27
14
Subtotal
1383
488
4489
1899
15
Dudloads
16%
17%
220
81
16%
17%
713
315
Total room load
1603
569
5203
2214
Air required (cfm)
56
31
182
121
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- rightsoft 2021 -Jan-04 11:03:44
w°-""""" 1-l'-, Right -Suite@ Universal2021 21.0.02 RSU27054
gCC,K Page 2
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By. Vicki Lynne Nisa
1
Room name
Bed 3
Bed 4
2
Exposed wall
12.0 ft
46.5 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/000l
4
Room dimensions
13.0 x 12.0 ft
17.5 x 14.5 ft
5
Room area
156.0 ft2
253.8 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
164
4
0
141
0
0
444
26
0
284
23
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
20
0
181
141
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
a
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
136
12
124
0
392
101
251
244
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
113
0
95
0
299
0
191
0
136
0
106
0
335
0
214
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
18
0
0
0
151
0
366
30
0
0
0
252
0
610
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
156
156
247
191
254
254
403
310
F
DftRor
0.989
28.68
0.00
156
12
344
0
0
0
0
0
F
Mor
0.989
28.68
0.00
0
0
0
0
254
47
1334
0
6
c) AED excursion
160
58
Envelope loss/gain
1042
908
3466
2136
12
a) Infiltration
307
91
1189
354
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
250
750
Subtotal (lines 6 to 13)
1348
1249
4655
3240
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
117
48
0
0
14
Subtotal
1466
1297
4655
3240
15
Dudloads
16%
17%
233
215
16%
17%
740
537
Total room load
1699
1512
5395
3777
Air required (cfm)
59
83
189
206
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right-Suite®Universal2021 21.0.02 RSU27054
,4CC,K Page 3
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
Dining Room
Great Room
2
Exposed wall
12.0 ft
35.5 ft
3
Room height
12.0 ft heat/cool
12.0 ft heat/cool
4
Room dimensions
12.0 x 8.5 ft
1.0 x 436.3 ft
5
Room area
102.0 ft2
436.3 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
144
0
6
108
0
0
340
0
44
218
0
39
168
0
0
60
0
0
189
0
0
121
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
30
0
0
0
252
0
202
0
0
108
0
0
0
971
0
758
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
a
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
0
0
0
0
0
0
0
0
234
0
152
0
478
0
306
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
12
12
87
102
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
30
30
252
262
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
40
24
40
24
361
76
278
48
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
102
102
162
125
436
436
692
533
F
DftRor
0.989
28.68
0.00
0
0
0
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
102
12
344
0
436
36
1018
0
6
c) AED excursion
-10
-60
Envelope loss/gain
1142
574
4125
2349
12
a) Infiltration
392
117
1158
345
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
3
690
Appliancestother
0
900
Subtotal (lines 6 to 13)
1534
690
5283
4284
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
140
57
14
Subtotal
1534
690
5423
4340
15
Dudloads
16%
17%
244
114
16%
17%
862
720
Total room load
1777
805
6285
5060
Air required (dm)
62
44
220
277
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right-Suite®Universal2021 21.0.02 RSU27054
,4CC,K Page 4
cuments\WrightsoftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
Kitchen
Laundry
2
Exposed wall
O ft
O ft
3
Room height
12.0 ft heat/cool
9.4 ft heat/cool
4
Room dimensions
1.0 x 217.3 ft
1.0 x 74.0 ft
5
Room area
217.3 ft2
74.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
e
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
217
217
345
266
74
74
117
90
F
DftRor
0.989
28.68
0.00
0
0
0
0
74
0
0
0
F
DftRor
0.989
28.68
0.00
217
0
0
0
0
0
0
0
6
c) AED excursion
-33
-8
Envelope loss/gain
345
232
117
82
12
a) Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
2
460
0
0
Appliancestother
1700
500
Subtotal (lines 6 to 13)
345
2392
117
582
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
277
98
66
27
14
Subtotal
622
2490
183
609
15
Dudloads
16%
17%
99
413
16%
17%
29
101
Total room load
721
2903
213
710
Air required (cfm)
251
159
7
39
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right -Suite® Universal2021 21.0.02 RSU27054
,4Ccr. Page 5
cuments\WrightsoftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
M Bath
M Hall
2
Exposed wall
22.0 ft
10.0 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/cool
4
Room dimensions
1.0 x 125.8 ft
6.0 x 9.0 ft
5
Room area
125.8 ft2
54.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
e
a
3.15
8.41
2.02
20.34
80
0
80
0
252
0
161
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
0
0
0
0
0
0
0
0
56
0
56
0
178
0
114
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
0
38
0
38
0
118
0
76
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
127
127
373
139
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
126
126
200
154
54
54
86
66
F
DftRor
0.989
28.68
0.00
0
0
0
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
126
22
631
0
54
10
287
0
6
c) AED excursion
-7
-5
Envelope loss/gain
1455
446
669
251
12
a) Infiltration
217
65
256
76
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
0
0
Subtotal (lines 6 to 13)
1672
511
924
327
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
-924
-327
14
Subtotal
1672
511
0
0
15
Dudloads
16%
17%
266
85
16%
17%
0
0
Total room load
1938
596
0
0
Air required (cfm)
68
33
0
0
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right -Suite@ Universal2021 21.0.02 RSU27054
,4CC,K Page 6
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
Master Bedroom
Mud Room
2
Exposed wall
39.0 ft
18.5 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/000l
4
Room dimensions
17.0 x 13.5 ft
1.0 x 61.8 ft
5
Room area
229.5 ft2
61.8 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
9
0
0
9
0
0
30
0
0
19
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
e
a
3.15
8.41
2.02
20.34
127
0
127
0
400
0
256
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
160
0
124
0
390
0
250
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
36
36
303
315
0
0
0
0
G
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
80
0
80
0
252
0
161
0
14
0
14
0
44
0
28
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
150
150
442
165
C
Attic, Shnql Roof,
0.405
1.59
1.22
230
230
364
280
62
62
98
75
F
DftRor
0.989
28.68
0.00
230
39
1119
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
0
0
0
0
62
19
531
0
6
c) AED excursion
-28
-4
Envelope loss/gain
2827
1233
1144
283
12
a) Infiltration
997
297
64
19
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
500
0
Subtotal (lines 6 to 13)
3824
2030
1208
302
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
231
82
0
0
14
Subtotal
4055
2112
1208
302
15
Dudloads
16%
17%
644
350
16%
17%
192
50
Total room load
4700
2462
1400
352
Air required (cfm)
164
135
49
19
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right -Suite® Universal2021 21.0.02 RSU27054
,4CC,K Page 7
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
Pantry
Hall
2
Exposed wall
7.5 ft
4.5 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/000l
4
Room dimensions
7.5 x 5.0 ft
4.5 x 14.0 ft
5
Room area
37.5 ft'
63.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
e
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
42
0
42
0
133
0
85
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
70
0
70
0
222
0
142
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
38
38
59
46
63
63
100
77
F
DftRor
0.989
28.68
0.00
0
0
0
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
38
8
215
0
63
5
129
0
6
c) AED excursion
-3
-3
Envelope loss/gain
497
185
362
160
12
a) Infiltration
192
57
115
34
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
0
0
Subtotal (lines 6 to 13)
688
242
477
194
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
231
82
-477
-194
14
Subtotal
920
323
0
0
15
Dudloads
16%
17%
146
54
16%
17%
0
0
Total room load
1066
377
0
0
Air required (cfm)
37
21
0
0
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right -Suite@ Universal2021 21.0.02 RSU27054
,4CC,K Page 8
moments\WrightsoftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
Sitting Room
Storage
2
Exposed wall
9.5 ft
8.5 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/cool
4
Room dimensions
11.5 x 12.0 ft
3.5 x 8.5 ft
5
Room area
138.0 ft2
29.8 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Lowe
Impact, Clear, Lowe
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Lowe
Impact, Clear, Lowe
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Lowe
0.109
0.290
e
a
3.15
8.41
2.02
20.34
89
0
71
0
225
0
144
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
18
0
18
0
151
0
158
0
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
G
Impact, Clear, Lowe
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Lowe
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
80
80
235
87
C
Attic, Shnql Roof,
0.405
1.59
1.22
138
138
219
169
30
30
47
36
F
DftRor
0.989
28.68
0.00
138
10
272
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
0
0
0
0
30
9
244
0
6
c) AED excursion
-11
-2
Envelope loss/gain
867
460
526
122
12
a) Infiltration
243
72
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
250
0
Subtotal (lines 6 to 13)
1110
782
526
122
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1110
782
526
122
15
Dudloads
16%
17%
176
130
16%
17%
84
20
Total room load
1287
912
609
142
Air required (cfm)
45
501
21
8
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right-Suite®Universal2021 21.0.02 RSU27054
,4CC,K Page 9
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
WC/Tub
WIC
2
Exposed wall
6.0 ft
1.0 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/cool
4
Room dimensions
6.5 x 6.0 ft
1.0 x 60.3 ft
5
Room area
39.0 ft2
60.3 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Low-e
Impact, Clear, Low-e
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Low-e
Impact, Clear, Low-e
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Low-e
0.109
0.290
e
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Low-e
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
G
Impact, Clear, Low-e
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
56
0
56
0
178
0
114
0
0
0
0
0
0
0
0
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
9
9
28
10
C
Attic, Shnql Roof,
0.405
1.59
1.22
39
39
62
48
60
60
96
74
F
DflHlor
0.989
28.68
0.00
0
0
0
0
0
0
0
0
F
DflHlor
0.989
28.68
0.00
39
6
172
0
60
1
29
0
6
c) AED excursion
-3
-1
Envelope loss/gain
412
158
152
83
12
a) Infiltration
153
46
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
0
0
Subtotal (lines 6 to 13)
565
204
152
83
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
185
65
14
Subtotal
565
204
337
148
15
Dudloads
16%
17%
90
34
16%
17%
54
25
Total room load
655
238
390
173
Air required (cfm)
23
131
14
9
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- 2021 -Jan-04 11:03:44
rightsoft w°-""""" 1-l'-, Right -Suite® Universal2021 21.0.02 RSU27054
,4CC,K Page 10
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
WIC 3
WIC 4
2
Exposed wall
0 ft
8.0 ft
3
Room height
9.4 ft heat/cool
9.4 ft heat/000l
4
Room dimensions
4.5 x 8.0 ft
6.0 x 8.0 ft
5
Room area
36.0 ft2
48.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft)
Load
number
(Btuh/f -°F)
(Btuh/IE)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Blk Wall, StucExt,
Impact, Clear, Low-e
Impact, Clear, Low-e
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Low-e
Impact, Clear, Low-e
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.310
n
8.99
7.02
0
0
0
0
0
0
0
0
W
LG
Blk Wall, StucExt,
Impact, Clear, Low-e
0.109
0.290
a
a
3.15
8.41
2.02
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
G
Impact, Clear, Low-e
Blk Wall, StucExt,
0.290
0.109
a
s
8.41
3.15
8.80
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.250
s
7.25
8.47
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
0.290
s
8.41
8.74
0
0
0
0
0
0
0
0
Impact, Clear, Low-e
Blk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
0
75
0
75
0
237
0
152
Impad, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
�G
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
0
0
0
0
C
Attic, Shnql Roof,
0.405
1.59
1.22
36
36
57
44
48
48
76
59
F
DftRor
0.989
28.68
0.00
36
0
0
0
0
0
0
0
F
DftRor
0.989
28.68
0.00
0
0
0
0
48
8
229
0
6
c) AED excursion
-1
-4
Envelope loss/gain
57
43
543
207
12
a) Infiltration
0
0
204
61
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
0
0
Subtotal (lines 6 to 13)
57
43
747
267
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
57
43
747
267
15
Dudloads
16%
17%
9
7
16%
17%
119
44
Total room load
66
51
866
312
Air required (cfm)
2
31
30
17
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- rightsoft 2021-Jan-0411:03:44
w°-""""" 1-l'-, Right-Suite®Universal2021 21.0.02 RSU27054
,4CC,K Page 11
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC
Right-J® Worksheet
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynm@aircalcs.com
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
1
Room name
WtrClst
2
Exposed wall
6.0 ft
3
Room height
9.4 ft heat/cool
4
Room dimensions
4.5 x 6.0 ft
5
Room area
27.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area
Load
number
(Btuh/ft---°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
G
G
Bilk Wall, StucExt,
Impact, Clear, Low-e
Impact, Clear, Low-e
0.109
0.250
0.250
n
n
n
3.15
7.25
7.25
2.02
6.47
6.47
0
0
0
0
0
0
0
0
0
0
0
0
11
Impact, Clear, Low-e
Impact, Clear, Low-e
0.290
0.310
n
n
8.41
8.99
6.74
7.02
0
0
0
0
0
0
0
0
G
Impact, Clear, Low-e
0.310
n
8.99
7.02
0
0
0
0
W
LG
BlkWall, StucEA,
Impact, Clear, Low-e
0.109
0.290
e
e
3.15
8.41
2.02
20.34
56
0
56
0
178
0
114
0
G
Inn pad, Clear, Low-e
Bilk Wall, StucExt,
Impad, Clear, Low-e
0.290
0.109
0.250
e
s
s
8.41
3.15
7.25
8.80
2.02
8.47
0
0
0
0
0
0
0
0
0
0
0
0
W
Impact, Clear, Low-e
0.290
s
8.41
8.74
0
0
0
0
G
Impact, Clear, Low-e
0.290
s
8.41
8.74
0
0
0
0
Impact, Clear, Low-e
Bilk Wall, StucExt,
0.310
0.109
s
w
8.99
3.15
6.91
2.02
0
0
0
0
0
0
0
0
W
Impact, Clear, Lowe
Impad, Clear, Lowe
0.290
0.290
w
w
8.41
8.41
20.34
20.34
0
0
0
0
0
0
0
0
C.
P
Frm Wall,1/2" Gyp B
0.101
2.94
1.09
0
0
0
0
C
Attic, Shnal Roof,
0.405
1.59
1.22
27
27
43
33
F
DftFlor
0.989
28.68
0.00
0
0
0
0
F
DftFlor
0.989
28.68
0.00
27
6
172
0
6
c) AED excursion
-3
Envelope loss/gain
393
144
12
a) Infiltration
153
46
b) Room ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
Appliancestother
0
Subtotal (lines 6 to 13)
546
190
Less external load
0
0
Lesstransfer
0
0
Redistribution
0
0
14
Subtotal
546
190
15
Ductloads
16%
17%
87
31
Total room load
633
221
Air required (cfm)
22
12
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-ri- rightsoft 2021-Jarr0411:03:44
w.-""1.1.1 "`" __ Right-Suite®Universal2021 21.0.02 RSU27054
,4CC,K Page 12
cuments\Wrig%oftHVAC\5194Tree Top Trail.rp Calc=MJ8 FrontDoorfaces: S
Air Calcs, LLC Duct System Summary
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
For: Herd Residence, Air Conditioning Unlimited, LLC
5194 Tree Top Trail, Port St Lucie, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply/return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.70
in H2O
0
in H2O
0.70
in H2O
0.535 / 0.165
in H2O
0.092
i n/100ft
1283
cfm
757 ft
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
Cooling
0.70
in H2O
0
in H2O
0.70
in H2O
0.535 / 0.165
in H2O
0.092
in/100ft
1283
cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath
h 174
7
6
0.095
4.0
Ox0
VIFx
64.4
500.0
St6
Bath
h 1603
67
37
0.095
5.0
Ox0
VIFx
62.9
500.0
st5
Bed 2
h 5203
218
145
0.093
10.0
Ox 0
VI Fx
75.8
500.0
St6
Bed 3
c 1512
71
99
0.095
6.0
Ox 0
VI Fx
62.9
500.0
St6
Bed 4
c 3777
227
248
0.092
10.0
Ox 0
VI Fx
78.7
500.0
st5
Dining Room
h 1777
75
53
0.236
5.0
Ox 0
VIFx
26.4
200.0
SO
Great Room
c 2530
132
166
0.159
8.0
Ox0
VIFx
37.2
300.0
st3
Great Room -A
c 2530
132
166
0.159
8.0
Ox0
VIFx
36.7
300.0
st3
Kitchen
c 1452
15
95
0.246
6.0
Ox0
VIFx
17.5
200.0
st1
Kitche A
c 1452
15
95
0.247
6.0
Ox0
VIFx
16.2
200.0
st1
Laundry
c 710
9
47
0.119
4.0
Ox0
VIFx
48.2
400.0
st4
M Bath
h 1938
81
39
0.242
6.0
Ox 0
VI Fx
16.2
205.0
st2
Master Bedroom
h 2350
99
81
0.233
6.0
Ox 0
VI Fx
24.5
205.0
St2
Master Bedroom -A
h 2350
99
81
0.235
6.0
Ox 0
VI Fx
22.9
205.0
st2
Mud Room
h 1400
59
23
0.238
5.0
Ox 0
VI Fx
24.6
200.0
st1
Pantry
h 1066
45
25
0.241
4.0
Ox0
VIFx
21.5
200.0
st1
Sitting Room
c 912
54
60
0.095
5.0
Ox 0
VIFx
65.4
500.0
St5
Storage
h 609
26
9
0.239
4.0
Ox0
VIFx
24.1
200.0
st1
W C/Tub
h 655
27
16
0.095
4.0
Ox 0
VI Fx
65.7
500.0
St6
W Ic
h 390
16
11
0.244
4.0
Ox 0
VI Fx
14.3
205.0
St2
WIC 3
c 51
3
3
0.119
4.0
Ox 0
VI Fx
48.8
400.0
St4
WIC 4
h 866
36
20
0.094
4.0
Ox 0
VI Fx
67.8
500.0
st5
WtrClst
h 633
27
15
0.237
4.0
Ox0
VIFx
20.5
205.0
st2
wrightsoft®
M=e •I a b =.- -,I—— Right-Sute@Universal 2021 21.0.02 RSU27054
�CA...cuments\WrigWoftHVAC\5194Tree Top Trail.rup Calc=MJ8 FrontDoorfaces: S
2021-Jarr04 11:03:46
Page 1
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st5
PeakAVF
384
365
0.092
489
12.0
0 x 0
VinlFlx
st4
st6
PeakAVF
325
266
0.093
413
12.0
0 x 0
VinlFlx
st4
st4
PeakAVF
720
681
0.092
516
16.0
0 x 0
VinlFlx
st3
st3
PeakAVF
984
1013
0.092
573
18.0
0 x 0
VinlFlx
st1
st1
PeakAVF
1218
1314
0.092
743
18.0
0 x 0
VinlFlx
st2
PeakAVF
322
226
0.233
728
9.0
0 x 0
VinlFlx
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb2
Ox0
717
792
178.7
0.092
567
16.0
Ox 0
VIFx
rt1
rb1
Ox0
214
173
175.4
0.094
484
9.0
Ox 0
VIFx
rt1
rb6
Ox 0
263
268
0
0
0
0
Ox 0
VI Fx
rb5
Ox 0
54
60
0
0
0
0
Ox 0
VI Fx
rb4
Ox 0
74
102
0
0
0
0
Ox 0
VI Fx
rb3
Ox 0
218
145
0
0
0
0
Ox 0
VI Fx
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
rt1
PeakAVF
931
964
0.092
546
18.0
0 x 0
VinlFlx
wrightsoft®
A.. • I a b =-1—,1—— Right-Sute®Urrversal2021 21.0.02 RSU27054
�CA...cuments\WrigWoftHVAC\5194Tree Top Trail.rup Calc=MJ8 FrordDoorfaces: S
2021-Jarr04 11:03:46
Page 2
Air Calcs, LLC Manual S Compliance Report
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
For: Herd Residence, Air Conditioning Unlimited, LLC
5194 Tree Top Trail, Port St Lucie, FL 34951
Design Conditions
Job: 1403
Date: Dec 30, 2020
By: Vicki Lynne Nisa
Outdoor design DB:
90.4°F
Sensible gain: 24543
Btuh Entering coil DB: 75.9°F
Outdoor design WB:
77.4°F
Latent gain: 10416
Btuh Entering coil WB: 63.8°F
Indoor design DB:
75.0°F
Total gain: 34959
Btuh
Indoor RH:
50%
Estimated airflow: 1283
cfm
Manufacturer's Performance Data
at Actual Design Conditions
Equipmenttype:
SplitAC
Manufacturer:
Lennox
Model: ML14XC1-041-230A**+CBA27UHE-048-230*++TDR
Actual airflow:
1283
cfm
Sensible capacity:
26950
Btuh
110% of load
Latent capacity:
11550
Btuh
111 % of load
Total capacity:
38500
Btuh
110% of load SHR: 70%
Design Conditions
Outdoor design DB: 41.0°F Heat loss: 38678 Btuh
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: Elecstrip
Manufacturer: Model:
Actual airflow: 1283 cfm
Output capacity: 11.1 kW 98% of load
Meets all requirements ofACCA Manual S.
Entering coil DB: 68.4°F
Temp. rise: 50 °F
wrightsoft© 2021-Jarr0411:03:46
AM,.ek•Iae,.n„��„naw,1—p , Right-Sute®Universal2021 21.0.02 RSU27054
�CA Page 1
...cumerrts\WrightsoftHVAC\5194Tree Top Trail.rup CaIc=MJ8 Front Door faces: S
Job M 1403
Performed by Vicki Lynne Nisa for:
Herd Residence
5194 Tree Top Trail
Port St Lucie, FL 34951
Level 1
Air Calcs, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
vickilynne@aircalcs.com
Scale: 1 : 243
Page 1
Right-Suite(g) Universal 2021
21.0.02 RSU27054
2021-Jan-04 11:04:07
...oft HVAC\5194 Tree Top Trail.rup