FL #FL30343-R0
Application Type New
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Premier Metal
Address/Phone/Email 17613 South Hwy. 475
Summerfield, FL 34491
(352) 356-1609
flvalidation@yahoo.com
Authorized Signature Ray Bowen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
LOCKE BOWDEN, P.E.
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 08/03/2022
Validated By Diane Marotta, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL30343_R0_COI_CERT OF INDEPEND LOCKE.pdf
Referenced Standard and Year (of Standard)Standard Year
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
9/10/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvH%2bffZfjpUCYkVDshJc8dKip0T60Tm28CUJ5HNQkoL2A%3d%3d 2/3
Date Submitted 08/16/2019
Date Validated 08/16/2019
Date Pending FBC Approval 08/21/2019
Date Approved 10/15/2019
Date Revised 08/13/2020
Summary of Products
FL #Model, Number or Name Description
30343.1 5 V CRIMP 26GA Steel over Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--86psf
Other: -63.5PSF@16"o.c. -86psf@12"o.c. Install per
manufacturer's details and in accordance with FBC. Not for use
in HVHZ,
Installation Instructions
FL30343_R0_II_5 V CRIMP-ssn.pdf
Verified By: Intertek Testing Services NA Inc (Elm)
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R0_AE_5 V CRIMP-ssn.pdf
Created by Independent Third Party: Yes
30343.2 PL-100 Nailstrip 26GA Nailstrip Steel over Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-86psf
Other: -86psf @ 5-1/4" o.c. w/adhesive -57.62psf@5-/4" o.c.
w/out adhesive Install per manufacturer's detail and in
accordance with FBC. Not for use in HVHZ.
Installation Instructions
FL30343_R0_II_PL-100 26GA Steel Nailstrip-ssn.pdf
Verified By: Intertek Testing Services NA Inc (Elm)
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R0_AE_PL-100 26GA Steel Nailstrip-ssn.pdf
Created by Independent Third Party: Yes
30343.3 PL-100 Nailstrip .029 ALUMINUM NAILSTRIP over plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--153.5
Other: -153.5 @5-1/4 O.C.w/adhesive -57.62PSF@5-1/4O.C.
w/out adhesive.Install per manufacturer's detail and in
accordance with FBC. Not for use in HVHZ,
Installation Instructions
FL30343_R0_II_PL-100 NAIL STRIP ALUM-ssn.pdf
Verified By: Intertek Testing Services NA Inc (Elm)
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R0_AE_PL-100 NAIL STRIP ALUM-ssn.pdf
Created by Independent Third Party: Yes
30343.4 PR-5 RIB 26 GA RIB PANEL over plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5
Other: -108.5PSF @ 18" o.c. clip spacing. Install per
manufacturer's details and in compliance with FBC. Not for use
in HVHZ.
Installation Instructions
FL30343_R0_II_PREMIER METAL PL-75 RIB REPORT-ssn.pdf
Verified By: LOCKE BOWDEN, P.E. FL 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R0_AE_PREMIER METAL PL-75 RIB REPORT-ssn.pdf
Created by Independent Third Party: Yes
30343.5 PS-175 .032 ALUMINUM SNAP LOCK over plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--108.5
Other: -108.5PSF@18"Oo.c. clip spacing. Install per
manufacturer's detail and in accordance with FBC. Not for use
in HVHZ,
Installation Instructions
FL30343_R0_II_PS-175-.032 ALUMIN SNAP LOCK-ssn.pdf
Verified By: Intertek Testing Services NA Inc (Elm)
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R0_AE_PS-175-.032 ALUMIN SNAP LOCK-ssn.pdf
Created by Independent Third Party: Yes
30343.6 PS-175 26GA Steel Snap Lock over plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/--93.5
Other: -93.5psf@12"o.c. clip spacing -63.5psf@16"o.c. clip
spacing Install per manufacturer's detail and in accordance with
FBC. Not for use in HVHZ,
Installation Instructions
FL30343_R0_II_PS-175 26GA SNAP LOCK Steel -ssn.pdf
Verified By: Intertek Testing Services NA Inc (Elm)
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R0_AE_PS-175 26GA SNAP LOCK Steel -ssn.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
9/10/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvH%2bffZfjpUCYkVDshJc8dKip0T60Tm28CUJ5HNQkoL2A%3d%3d 3/3
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: