HomeMy WebLinkAbout2026605_Premier metal 26GA SNAP LOCK (1) PS-175 26GA SNAP LOCK Steel Panel over Plywood
Florida Building Code 2017 6th ed.
Compliance: Per Rule 61G20-3 Method: 1-D
Category: Roofing -Subcategory: Metal Roofing NON-HVHZ
9450 AJysbury Place
Montgomery, AL 36117
Premier Metal
17613 South Hwy. 475
Summerfied, FL. 34491
352-356-1609
Engineer Validator
Diane Marotta, P.E.
555 Prospect Road
Oakland, FL 33309
Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code
Product Description:
Material:
Panel Dimensions:
Fastener: 2017
Section 1506.7.
26ga steel conforming to Florida Building Code 2017 Section 1507.4.3
Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3
Panel Widths: 18” width panels 49ksi . Plywood supports at maximum 24' O.C.
#10-12 X 1" PANCLIP fastener Wood screw Corrosion Resistant per Florida Building Code 1/4" min.
penetration through bottom of plywood. CLIPS: 3-12" LONG 18GA G-90 Galvanized OR Stainless steel
Design of plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017.
Minimum Slope :
Installation:
Underlayment:
Fire Classification:
Shear Diaphragm:
Design Procedure:
Range Slope per Florida Building Code 2017 6th ed., in accordance with Manufacturers recommendations.
Install per manufacturer's recommended details.
Per Manufacturer's installation guidelines per Florida Building Code 2017, CHAPTER 1507, CHART 1507.1.1
Classification not part of this report.
Values are outside the scope of this report.
Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the
Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are
Compared to the allowable pressure listed above. The design professional shall select the applicable
erection details to reference in drawings for correct fastener attachment to his structure and analyze the
panel fasteners for pullout and pullover. Support framing must be compliant with Florida Building Code
2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
Florida Product Approval # FL 30343
Locke Bowden, P.E.
FL # 49704
Panel restrained with fasteners.
2017 6th ed., Sections 1504.3.2, 1507.4.3, 1507.1.1
PS-175 26 GA Steel SNAP LOCK Panel, 18" Width Roof panels. over 15/32" 4-ply
CDX plywood over supports@ 24" O.C. MAX. 49ksi rib height 1-3/4"
Engineer Evaluator
Locke Bowden, P.E.
_______________________________________________________________________________________
Design Uplift Pressures: Uplift Design Pressure: with Safety Factor of 2
-63.5psf 16"o.c. clip spacing
-93.5psf 12"o.c. clip spacing
__________________________________________________________
_ Test References: -I4625.03-450-44-R0
UL 580-06-Test for Uplift Resistance of Roof Assemblies
Integrity Metal authorizes sharing this report.
Certificate of Independence: Locke Bowden, P.E. does not have nor will acquire financial interest in any company
manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned or operated or
controlled by any company manufacturing or distributing product under this report.
INSTALL DETAILS PER MANUFACTURER'S DETAILS AND IN ACCORDANCE WITH FBC 2017.
PS-175 SNAP LOCK 26GA STEEL PANEL_____________________________________________________
______________________________________________________
1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6TH ed.. see Chart 1507.1.1
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference.
3.Products are compliant with State of Florida product approval per Rule 61G20‐3. Compliance Method: 1‐D
4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.