Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 23 Block 5 Waterstone 1835 BGR Builder Name: ADAMS HOMES Street: 5368 Vespera Street Permit Office: City, State, Zip: Fort Pierce , FL, 34951 r Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1727.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1554.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 173.33 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1961.0 sqft.) Insulation Area 6. Conditioned floor area above grade (W) 1831 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1831.00 ft2 R=19.0 130.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(169.1 sqft-) Description Area 11. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 366.2 a. U-Factor: Dbl, U=0.33 122.34 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 25.95 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 d. U-Factor: other (see details) 3.00 ft2 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 3.248 ft. Area Weighted Average SHGC: 0.278 14. Hot water systems 8. Floor Types (1831.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1831.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.092 Total Proposed Modified Loads: 58.00 PASS Total Baseline Loads: 62.33 I hereby certify that the plans s cations covered ev of the plans and S�,� this calculation are in compl' the Florid rgy Code. specifications covered by this ©�THfi � �y calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 1_90_2020 Winn Kaomany this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Ener Florida Statutes. ,4 y CoWE t;ODt1� OWNER/AGEWT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY, 11 /20/2020 12:06 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 IAIPI IT cI IIIAIIAAOV f%upf+vl rLn-r nrrmr%r%- awn •aa—M� ■ yr rI F% rVR I PROJECT Title: Lot 23 Block 5 Waterstone 18 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1831 Lot # 23 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: 'ADAMS HOMES Rotate Angle: 0 Street: 5368 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Single-family , New/Existing: New (From Plans) FL , 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 %' 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 " 1831 17394.5 SPACES Number Name Area Volume Kitchen Occupants 1 Main 1831 17394.5 Yes 5 ;;,Id FLOORS # Floor Type Space Perimeter R-Value 1 Slab -On -Grade Edge Insulatio Main 184.9 ft 0 1831 ft' ---- ' ROOF V # Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2048 ftz 458 ftZ Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1831 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Knee Wall (Vented) Main 19 Batt 65 ftz 0.11 ' Wood 2 Knee Wall (Vented) Main 19 Batt 65 ft2 0.11 Wood 3 Under Attic (Vented) Main 30 Blown 1831 ft' 0.11 Wood 11/20/2020 12:06 PM EnergyGauge® USA 6.0.02 (Rev: 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 .A FORM R405-2017 INPUT SUMMARY CI-IFCKI IRT RFpnRT WALLS Adjacent Ornt To 1AW1 TypeEt Space Cavity Width In Height R In Area- Sheathing Framing Solar Below 0 1 NE Exterior Concrete Block - Int Insul Main 4.1 51 9 9 0 465.8 ft 0 0 0.6 0 2 SE Exterior Concrete Block - Int Insul Main 4.1 27 9 8 0 222.0 ft2 0 0 0.6 0 3 SW Exterior Concrete Block - Int Insul Main 4.1 52 5 9 0 471.8 ft2 0 0 0.6 0 4 NW Exterior Concrete Block - Int Insul Main 4.1 43 10 9 0 394.5 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 17 4 10 0 173.3 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 9.0 ft2 1 ft 20 in 0 ft 10 in Drapes/blinds None 2 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 9.8 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 5 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 4 ft 8 in 1 ft 0 in None None 6 SW 3 Vinyl Low''-E Double Yes 0.33 ' 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 7 NW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 8 ft 2 in 0 ft 6 in Drapes/blinds None 8 NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 9 NW 4 Vinyl Low-E Double Yes 0.33 '0.23 N 32.4 ft2 8 ft 0 in 0 ft 3 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000423 2029.4 111.41 209.52 .1568 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 34.6 kBtu/hr 1 sys#1 11/20/2020 12:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition'(2017) Compliant Software Page 3 of 4 FORM R405-2017 IIUPIIT ¢11M11neoV f%UCr►vl Ic'r e�r,r%ryw -� v■ ■■..vr��w � I�Gr VR 1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM � FSEC Cert # Company Name System Model # Collector Model Collector # Area Storage Volume FEF None None ft2 DUCTS / ---- Supply.---- �/ # Location R-Value Area ---- Return ---- Air Location Area Leakage Type Handler CFM 25 CFM25 TOT HVAC # OUT QN RLF Heat Cool 1 Attic 6 366.2 ft Main 91.55 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling j Jan Feb Heating X1 Jan X Feb Venting [ ]Jan [ Feb j Mar Mar X Mar [ A r APr A r [ Au May JunJul AuSep Ma rl Junrl Jul rl Ma Jun JulAug Se ri Se [X] Oct Oct Oct Nov Nov HX Nov [ ] Dec [IXl] Dec Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 11/20/2020 12:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 t 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level 2. Single-family or multiple family 2. Sin le family a) Supply ducts R Return ducts R 6.0b) 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Main 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 5. Is this a worst case? (yes/no) 5. No a) Split system SEER b) Single package SEER 16.0 6. Conditioned floor area (sq. ft.) 6. 1831 c) Ground/water source SEER/COP d) Room unit/PTAC EER 7. Windows, type and area e) Other a) U-factor:(weighted average) 7a. 0.353 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.278 14. Heating system: Capacity 34.6 c) Area 7c. 169.1 a) Split system heat pump HSPF 8.5 8. Skylights b) Single package heat pump HSPF a) U-factor: (weighted average) 8a. NA c) Electric resistance COP d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 9. Floor type, insulation level: f) Other a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 10. Wall type and insulation: b) Gas fired, natural gas EF c) Gas fired, LPG EF A. Exterior: 1. Wood frame (Insulation R-value) 10A1. d) Solar system with tank EF e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other I. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic b) Single assembly 11 a. 30.0 11 b. b) Cross ventilation No c) Knee walls/skylight walls 11 c. 19.0 c) Whole house fan d) Multizone cooling credit No d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signat� Date: Address of New Home: 5368 Vespera Street City/FL Zip: Fort Pierce, FL 34951 11/20/2020 12:06:45 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1