HomeMy WebLinkAboutPV permit package for project ES-212 GOPIEDIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXELECTRICAL CALCULATIONS MODULE DATASHEET DISCONNECT DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER MULCHAND GOPIE PROPERTY ADDRESS 1407 E EASY ST, FORT PIERCE, FL 34982 US APN 3402-609-0721-000-2 ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ COUNTY OF ST. LUCIE UTILITY COMPANY FLORIDA POWER & LIGHT CO METER SERIAL NUMBER 706104 ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 OTHER BUILDING CODES 2017 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY USA ENERGY SAVERS, LLC LICENSE NUMBER EC-13009451 (REG. ELECTRICIAN) ADDRESS 6833 PHILLIPS INDUSTRIAL BLVD SUITE 3, JACKSOVILLE, FL 32256 PHONE NUMBER (904) 903-7100 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PRE-ENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PV SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 8.32KW AC RATING OF SYSTEM 6.24KW AC OUTPUT CURRENT 26.0A INVERTER(S)26 X ENPHASE IQ7-60-2-US MODULE JINKO JKM320M-60 ARRAY WIRING (2) BRANCH OF 13 IQ7-60-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW LOAD-SIDE AC CONNECTION PER NEC 705.12(D)(2)(3)(B) AT MSP UTILITY SERVICE 120/240V 1Φ LOCATION MAIN SERVICE PANEL W/200A BUSBAR 200A MCB SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) RISK CATEGORY II WIND EXPOSURE CATEGORY C GROUND SNOW LOAD 0 PSF ES-212 GRID-TIED SOLAR POWER SYSTEMGOPIE RESIDENCE1407 E EASY STFORT PIERCE, FL 34982PROJECT SUMMARY DOC ID:150953-186108-1 DATE:12/16/20 CREATOR:H.C. REVIEWER: REVISIONS PV-1 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (E) UTILITY METER, OUTDOOR (E) MAIN SERVICE PANEL (MSP), OUTDOOR (N) VISIBLE, LOCKABLE, READILY-ACCESSIBLE AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER, OUTDOOR (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 8:12 (34°) SLOPED ROOF, 26 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 179° AZIMUTH (N) AC COMBINER, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. ES-212 GRID-TIED SOLAR POWER SYSTEMGOPIE RESIDENCE1407 E EASY STFORT PIERCE, FL 34982SITE PLAN DOC ID:150953-186108-1 DATE:12/16/20 CREATOR:H.C. REVIEWER: REVISIONS PV-2 PV MODULE MICROINVERTER PM1-26 320W 13 IN BRANCH 13 IN BRANCH 1 2 3 4 5 6 7 AC COMBINER 1 CB1 20A CB2 20A C1 PV DISCONNECTF1-2 35A 2 SW1 60A LOADS MAIN SERVICE PANEL AC GEC KWHR LOAD LINE KWHR LOAD LINE UTILITY METER (E) 456645 240/120V 1ɸ, 3W 200A BUSBAR 200A MAIN BREAKER (E) 200A CB3 35A (S/N: 706104) 8 9 10 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-26 26 JINKO JKM320M-60 320W 296W 10.15A 9.59A 40.9V 33.4V -0.115V/°C (-0.28%/°C)20A INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-26 26 ENPHASE IQ7-60-2-US 240V UNGROUNDED 240W 1.0A 15.0A 48V 97.0% DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222NRB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 20A 240VAC F1-2 2 35A 240VAC CB3 1 35A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 INVERTERS PER BRANCH 13 13 MAX AC CURRENT 13A 13A MAX AC OUTPUT 3,120W 3,120W ARRAY STC POWER 8,320W ARRAY PTC POWER 7,688W MAX AC CURRENT 26A MAX AC POWER OUTPUT 6,240W DERATED AC POWER OUTPUT 6,240W NOTES THE DC AND AC CONNECTORS OF THE ENPHASE IQ7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A). MATING CONNECTORS SHALL COMPLY WITH NEC 690.17(E). 1 THE ENPHASE IQ7-60-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. 2 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12.3 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. 4 UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) 5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A). THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47 AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS 43.8V AT 0°C (0°C - 25°C) X -0.115V/C + 40.9V = 43.8V).7 POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(D)(2)(3)(B). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL.8 THE BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. THE BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD".9 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. 10 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYI NG CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 1 8 AWG THWN-2, COPPER 0.5" DIA. LFMC 2 35A 10 AWG THWN-2, COPPER 0.76 (53°C)1.0 26A 32.5A 55A 41.8A 75°C 50A 24FT 0.41% 2 1 8 AWG THWN-2, COPPER 0.75" DIA. PVC-40 2 35A 10 AWG THWN-2, COPPER 0.96 (33°C)1.0 26A 32.5A 55A 52.8A 75°C 50A 48IN 0.07% REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE:GRID-TIED SOLAR POWER SYSTEMFORT PIERCE, FL 349821407 E EASY STPV-3 ES-212 12/16/20 H.C. 150953 SINGLE-LINE DIAGRAMGOPIE RESIDENCE1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE 5 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 6 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). SW1 - DISCONNECT (EATON DG222NRB ) MSP - MAIN SERVICE PANEL (NULL456645) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.17(E) AC DISCONNECT (SW1, CB3 IN MSP) MAXIMUM AC OPERATING CURRENT: 26.0A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 AC SOLAR DISCONNECT (SW1, CB3 IN MSP) PHOTOVOLTAIC AC DISCONNECT NEC 690.13(B) POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) ! CAUTION ! POWER TO THIS BUILDING IS ALSO FROM ROOF ARRAY WITH DISCONNECTS AS SHOWN INSTALLED BY USA ENERGY SAVERS, LLC • 9049037100 NEC 690.56(B) AND NEC 705.10 SEE NOTE NO. 4 (MSP) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.12 AND NEC 690.56(C) ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. NEC 705.12(D)(3) SOLAR BREAKER (MSP) ! WARNING ! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. NEC 705.12(D)(2)(3)(B) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN," SHALL BE LOCATED AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8” TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND ES-212 GRID-TIED SOLAR POWER SYSTEMGOPIE RESIDENCE1407 E EASY STFORT PIERCE, FL 34982SAFETY LABELS DOC ID:150953-186108-1 DATE:12/16/20 CREATOR:H.C. REVIEWER: REVISIONS PV-4 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 8/12 (33.7°) MEAN ROOF HEIGHT 26FT DECK SHEATHING 15/32" (1/2" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X6 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL JINKO JKM320M-60 DIMENSIONS (AREA)65.0IN X 39.1IN X 1.4IN (17.6 SQ FT) WEIGHT 40.8LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL ROOF TECH RT-MINI W/ (5) 2-3/8 IN SCREW FASTENERS, (1) 1-1/4 IN HEX BOLT AND NUT, 0.75IN AIR GAP FASTENING METHOD ATTACH TO ROOF SURFACE MAX. ALLOW. RAIL SPAN 144.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 47.5IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING TIN-PLATED, SOLID COPPER LAY-IN LUGS LISTED UNDER UL 2703 DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 26 40.8 1060.4 MICROINVERTERS 26 1.1 28.1 LINEAR FEET OF RAIL 174 FT 0.5 87.1 ANCHORS 54 0.5 29.6 MISC. HARDWARE 34.2 34.2 TOTAL ARRAY WEIGHT 1239.5 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 26 17.6 457.6 POINT LOAD (1239.5 LBS / 54 ATTACHMENTS)23.0 LBS DIST. LOAD (1239.5 LBS / 457.6 SQFT)2.71 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 6.5 FT = MAX(MIN(0.4 * 26.0 FT, 0.1 * 65.0 FT), 0.04 * 65.0 FT, 3 FT) ES-212 GRID-TIED SOLAR POWER SYSTEMGOPIE RESIDENCE1407 E EASY STFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:150953-186108-1 DATE:12/16/20 CREATOR:H.C. REVIEWER: REVISIONS PV-5 ES-212 GRID-TIED SOLAR POWER SYSTEMGOPIE RESIDENCE1407 E EASY STFORT PIERCE, FL 34982ATTACHMENT DETAILS DOC ID:150953-186108-1 DATE:12/16/20 CREATOR:H.C. REVIEWER: REVISIONS PV-6 GENERAL NOTES 1 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS (WINDOWS OR DOORS), ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION, AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS (TREE LIMBS, WIRES, OR SIGNS). (NFPA 1 11.12.2.2.1.3) 2 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF MODULES ARE TO BE PLACED ON BOTH SIDES OF THE HIP OR VALLEY. WHERE MODULES ARE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. (NFPA 1 11.12.2.2.2.1.3) 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS THAN 3 FT BELOW THE RIDGE. (NFPA 1 11.12.2.2.2.2) 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.12.2.2.2.2 3.0 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1.3 AND NFPA 1 11.12.2.2.2.1.2 PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT PV QRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 8/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE JINKO JKM320M-60 IS TYPE 1. ROOF ACCESS POINT ROOF ACCESS POINT 1.5 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1.3 AND NFPA 1 11.12.2.2.2.1.2 THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. ES-212 GRID-TIED SOLAR POWER SYSTEMGOPIE RESIDENCE1407 E EASY STFORT PIERCE, FL 34982FIRE SAFETY PLAN DOC ID:150953-186108-1 DATE:12/16/20 CREATOR:H.C. REVIEWER: REVISIONS PV-7 Conductor, Conduit, and OCPD Sizing Validation1. Maximum System Voltage Test1.1. Enphase inverter w/26 Jinko JKM320M-60 (320W)sArray PropertiesArray TypeMicroinverter ArraySystem DescriptionEnphase inverter w/26 JinkoJKM320M-60 (320W)sModuleJKM320M-60 (320W)Highest number of modules in seriesin a PV Source Circuit1Design Low Temp.0°CModule Voc40.9VTemp. Coefficient Voc-0.115V/CNEC Code CalculationsA. Maximum Voltage of PV Source Circuit43.77Vsee 690.7(C)NEC 690.7(C) requires that if the PV module manufacturer provides atemperature coefficient of open-circuit voltage, it must be used tocalculate the PV array's maximum system voltage. It includes aninformation note recommending the use of the ASHRAE 'Extreme AnnualMean Minimum Design Dry Bulb Temperature' as the design lowtemperature. Using these values, the module Voc (40.9V) will increase to43.77V at the design low temperature ( 0°C).(0°C - 25°C) X -0.115V/C + 40.9V = 43.77VThe module Voc at the design low temperature is 43.77V.43.77V X 1 = 43.77VNEC Code Validation Tests1.PV Source Circuit maximum Voc must not exceed600V43.77V < 600V = truePASS2. Wire, Conduit, and OCPD Code Compliance Validation2.1. #1: AC Combiner Output: AC Combiner to Utility DisconnectCircuit Section PropertiesConductor8 AWG THWN-2, CopperEquipment Ground Conductor (EGC)10 AWG THWN-2, CopperOCPD(s)35ARaceway/Cable0.5" dia. LFMCLowest Terminal TemperatureRating75°CMaximum Wire Temperature53°CPower Source DescriptionEnphase inverter w/26 JinkoJKM320M-60 (320W)sPower Source Current26AVoltage240VNEC Code CalculationsA. Continuous Current26Asee Article 100Equipment maximum rated output current is 26AB. Ampacity of Conductor55Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 55A.C. Derated Ampacity of Conductor41.8Asee Table 310.15(B)(2)(a), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 53°C is 0.76.The fill factor for a conduit/cable that has 2 wires is 1.The ampacity derated for Conditions of Use is the product of theconductor ampacity (55A) multiplied by the temperature factor (0.76) andby the fill factor (1).55A X 0.76 X 1 = 41.8AD. Max Current for Terminal Temp. Rating50Asee 110.14(C)The lowest temperature rating for this conductor at any termination is75°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 75°Crating would be the amount referenced in the 75°C column in Table310.15(B)(16), which is 50A.E. Minimum Allowed OCPD Rating32Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.26A X 1.25 = 32.5A rounded down to 32AF. Minimum Required EGC Size10 AWGsee Table 250.122The smallest EGC size allowed is 10 AWG for OCPD rating 35Aaccording to Table 250.122.G. Minimum Recommended Conduit Size0.5" dia.see 300.17The total area of all conductors is 0.0943in². With a maximum fill rate of0.4, the recommended conduit diameter is 0.5.QtyDescriptionSizeTypeAreaTotal Area2Conductor8 AWGTHWN-20.0366in²0.0732in²1Equipment Ground10 AWGTHWN-20.0211in²0.0211in²30.0943in²0.0943in² / 0.4 = 0.2358in² (Corresponding to a diameter of 0.5")NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)35A >= 26A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)41.8A >= 35A (OCPD Rating) = truePASS3.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)41.8A >= 26A = truePASS4.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))55A > 26A x 1.25 = truePASS5.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))50A >= 26A X 1.25 = truePASS6.EGC must meet code requirements for minimumsize (Table 250.122)10 AWG >= 10 AWG = truePASS7.Conduit must meet code recommendation forminimum size (300.17)0.5in. >= 0.5in. = truePASS 2.2. #2: Utility Disconnect Output: Utility Disconnect to Main Service PanelCircuit Section PropertiesConductor8 AWG THWN-2, CopperEquipment Ground Conductor (EGC)10 AWG THWN-2, CopperOCPD(s)35ARaceway/Cable0.75" dia. PVC-40Lowest Terminal TemperatureRating75°CMaximum Wire Temperature33°CPower Source DescriptionEnphase inverter w/26 JinkoJKM320M-60 (320W)sPower Source Current26AVoltage240VNEC Code CalculationsA. Continuous Current26Asee Article 100Equipment maximum rated output current is 26AB. Ampacity of Conductor55Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 55A.C. Derated Ampacity of Conductor52.8Asee Table 310.15(B)(2)(a), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 33°C is 0.96.The fill factor for a conduit/cable that has 2 wires is 1.The ampacity derated for Conditions of Use is the product of theconductor ampacity (55A) multiplied by the temperature factor (0.96) andby the fill factor (1).55A X 0.96 X 1 = 52.8AD. Max Current for Terminal Temp. Rating50Asee 110.14(C)The lowest temperature rating for this conductor at any termination is75°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 75°Crating would be the amount referenced in the 75°C column in Table310.15(B)(16), which is 50A.E. Minimum Allowed OCPD Rating32Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.26A X 1.25 = 32.5A rounded down to 32AF. Minimum Required EGC Size10 AWGsee Table 250.122The smallest EGC size allowed is 10 AWG for OCPD rating 35Aaccording to Table 250.122.G. Minimum Recommended Conduit Size0.75" dia.see 300.17The total area of all conductors is 0.1154in². With a maximum fill rate of0.4, the recommended conduit diameter is 0.75.QtyDescriptionSizeTypeAreaTotal Area2Conductor8 AWGTHWN-20.0366in²0.0732in²1Neutral10 AWGTHWN-20.0211in²0.0211in²1Equipment Ground10 AWGTHWN-20.0211in²0.0211in²40.1154in²0.1154in² / 0.4 = 0.2885in² (Corresponding to a diameter of 0.75")NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)35A >= 26A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)52.8A >= 35A (OCPD Rating) = truePASS3.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)52.8A >= 26A = truePASS4.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))55A > 26A x 1.25 = truePASS5.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))50A >= 26A X 1.25 = truePASS6.EGC must meet code requirements for minimumsize (Table 250.122)10 AWG >= 10 AWG = truePASS7.Conduit must meet code recommendation forminimum size (300.17)0.75in. >= 0.75in. = truePASS www.jinkosolar.comLINEAR PERFORMANCE WARRANTY10 Year Product Warranty 25 Year Linear Power Warranty80.2%90%97%100%151225yearsGuaranteed Power PerformanceLinear performance warrantyStandard performance warrantyAdditional value from Jinko Solar’s linear warranty300-320 WattMONO PERC MODULEPositive power tolerance of 0~+3%Eagle 60MISO9001:2008 Quality StandardsISO14001:2004 Environmental StandardsOHSAS18001 Occupational Health & Safety StandardsNomenclature:JKM320M - 60BCode Backsheetnull WhiteB BlackKEY FEATURES Certified for salt mist and ammonia resistanceWeather Resistance Certified for high snow (5400Pa) and wind (2400Pa) loadsStrength and DurabilityHigher module conversion efficiency (up to 19.55%) due toPassivated Emmiter Rear Contact (PERC) technologyHigh EfficiencyAdvanced glass technology improves light absorption and retentionLow-Light PerformancePID FreeWorld’s 1st PID-Free moduleISO9001:2008QualitStInnovative Solar CellsFive busbar monocrystalline PERC cell technology improvesmodule efficiencyCurrent-Voltage & Power-Voltage Curves (310W)Temperature Dependence of Isc,Voc,PmaxPackaging ConfigurationsEngineering DrawingsMechanical CharacteristicsCAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.© Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice.JKM300-320M-60-A1-USCellTypeNo.ofCellsDimensionsWeightFrontGlassFrameJunctionBoxOutputCablesMonocrystallinePERC156×156mm(6inch)60(6×10)1650×992×35mm(65.00×39.05×1.37inch)19.0kg(41.9lbs.)AnodizedAluminiumAlloy(Black)IP67RatedSPECIFICATIONSElectrical Performance & Temperature Dependence-50-2502550 75 10020406080100120140160180IscVocPmaxPowermeasurementtolerance:±3%*ModuleTypeMaximumPower(Pmax)MaximumPowerVoltage(Vmp)MaximumPowerCurrent(Imp)Open-circuitVoltage(Voc)Short-circuitCurrent(Isc)ModuleEfficiencySTC(%)OperatingTemperature(℃)30pcs/pallet,60pcs/stack,840pcs/40'HQContainerIrradiance1000W/m2CellTemperature25°CAM=1.5AM=1.5STC:Irradiance800W/m2AmbientTemperature20°CNOCT:WindSpeed1m/s12AWG,Length:900mm(35.43inch)FireTypeType1999999999999999999994.51495.5555538*35±1mm (1.37”)942±2mm (37.09”)860±1mm (33.86”)1360±1mm (53.54”)992±2mm (39.06”)1650±2mm (64.97”)MaximumSystemVoltageMaximumSeriesFuseRatingPowerToleranceTemperatureCoefficientsofPmaxTemperatureCoefficientsofVocTemperatureCoefficientsofIscNominalOperatingCellTemperature(NOCT)3.2mm,Anti-reflectionCoating,HighTransmission,LowIron,TemperedGlassAAJunction box9999 999 999 999 99999 99100 LCathode -+ AnodeConnectorLabelúInstalling HolesGrounding Holes2-Ø41000VDC (UL and IEC)5101520 25 3035400024681012050100150200250300350357.735(Twopallets=Onestack)-40℃~+85℃20A0~+3%-0.37%/℃-0.28%/℃0.048%/℃45±2℃JKM315M-60315Wp33.2V9.49A40.7V10.04A19.24%235Wp7.56A31.2V37.6V8.33ASTC NOCTJKM320M-60320Wp33.4V9.59A40.9V10.15A19.55%239Wp7.62A31.4V37.8V8.44ASTC NOCTJKM300M-60300Wp32.6V9.21A40.1V9.72A18.33%224Wp7.32A30.6V37.0V8.01ASTC NOCTJKM305M-60305Wp32.8V9.30A40.3V9.83A18.63%227Wp7.40A30.8V37.2V8.12ASTC NOCTJKM310M-60310Wp33.0V9.40A40.5V9.92A18.94%231Wp7.49A31.0V37.4V8.20ASTC NOCT pe.eaton.com Eaton general duty cartridgefuse safety switchDG222NRBUPC:782113144221Dimensions:Height: 14.38 INlLength: 14.8 INlWidth: 9.7 INlWeight:10 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.lSpecifications:Type: General duty, cartridge fusedlAmperage Rating: 60AlEnclosure: NEMA 3RlEnclosure Material: Painted galvanized steellFuse Class Provision: Class H fuseslFuse Configuration: Fusible with neutrallNumber Of Poles: Two-polelNumber Of Wires: Three-wirelProduct Category: General duty safety switchlVoltage Rating: 240VlSupporting documents:Eatons Volume 2-Commercial DistributionlEaton Specification Sheet - DG222NRBlCertifications: UL ListedlProduct compliance: No Data______________________________________________________________________© 2016 Eaton. All rights reserved. The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+MicroinvertersTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Productive and Reliable• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-USIQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹235 W - 350 W +235 W - 440 W +Module compatibility60-cell PV modules only60-cell and 72-cell PV modulesMaximum input DC voltage48 V60 VPeak power tracking voltage27 V - 37 V27 V - 45 VOperating range16 V - 48 V16 V - 60 VMin/Max start voltage22 V / 48 V22 V / 60 VMax DC short circuit current (module Isc)15 A15 AOvervoltage class DC portIIIIDC port backfeed current0 A0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 MicroinverterIQ 7+ MicroinverterPeak output power250 VA295 VAMaximum continuous output power240 VA290 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 V240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V)Nominal frequency60 Hz60 HzExtended frequency range47 - 68 Hz47 - 68 HzAC short circuit fault current over 3 cycles5.8 Arms5.8 ArmsMaximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC)Overvoltage class AC portIIIIIIAC port backfeed current0 A0 APower factor setting1.01.0Power factor (adjustable)0.85 leading ... 0.85 lagging0.85 leading ... 0.85 laggingEFFICIENCY@240 V@208 V@240 V@208 VPeak efficiency97.6 %97.6 %97.5 %97.3 %CEC weighted efficiency97.0 %97.0 %97.0 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +65ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy.Disconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7 and IQ 7+ Microinverters QRail — Fully Integrated Mounting and Racking SystemThe QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar designers and installers. Combined with Quick Mount PV’s industry-leading waterproof mounts, QRail offers a complete racking solution for mounting solar modules on any roof. QRail, together with Quick Mount PV’s waterproof mounting products, provides the benefit of a single-sourced, seamlessly integrated rooftop installation that works with all roof types — composition/asphalt shingles, flat or curved tile, metal shingle, shake, slate and low slope roofs. The QRail system also works with any roof attachment system for maximum flexibility.Comprehensive, One-Source SolutionFast, Simple Installation: It Just ClicksThe QRail system provides an integrated electrical bonding path, ensuring that all exposed metal parts and the solar module frames are electrically connected. All electrical bonds are created when the components are installed and tightened down.Fully Integrated Electrical BondingQClick TechnologyThe universal mid and end clamps use patented QClick technology to simply “click” into the rail channel and remain upright, ready to accept the module. The pre-assembled clamps fit virtually all module frames and require no extra hardware, eliminating pre-loading and reducing installation time.Superior Strength and VersatilityQRail is engineered for optimal structural performance. The system is certified to UL 2703, fully code compliant and backed by a 25-year warranty. QRail is available in Light, Standard and Heavy versions to match all geographic locations. QRail is compatible with virtually all modules and works on a wide range of pitched roof surfaces. Modules can be mounted in portrait or landscape orientation in standard or shared-rail configurations.STANDARDLIGHT123click!click!2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL END CLAMP2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL BONDED MID CLAMPQRail’s innovative internal QSplice installs in seconds, requiring no tools or screws. Simply insert QSplice into the rail and slide the other rail on to create a fully structural, bonded splice. An external splice is also available.QSplice TechnologyQSPLICEHEAVYQRails come in two lengths —168 inches (14 ft) and 208 inches (17.3 ft)™™231Mill and Black FinishInstalls in seconds — no tools or hardware requiredInstalling is as easy as 1-2-3Easily design array configurations with the QDesign software application. Generate complete engineering reports and calculate a precise bill of materials for all the mounting, racking and accessories needed for a complete solar array.™  1815 W. Diehl Rd, Suite 100, Naperville, IL 60563 630-219-1997 (P) www.structuralenginuityinc.com   August 2, 2018 Attn: Mr. Marshall Green Quick Mount PV 2700 Mitchell Dr. Walnut Creek, CA, 94598 RE: Quick Mount PV – QRail Light PV Panel Racking System SEI Project No.: 17549.02 State of Florida Certification Letter Dear Mr. Green: Structural Enginuity Inc. (SEI) has completed its review of the Quick Mount PV – QRail Light PV Panel Racking System (QMR-RL) for typical installations in the state of Florida. The QRail Light is compliant with the sections of the following design references and codes when installed per the conditions and design criteria delineated herein. Design References and Codes: - ASCE/7-10 – Minimum Design Loads for Buildings and Other Structures - 2015 Aluminum Design Manual, by the Aluminum Association - Materials information and section and details provided by Quick Mount PV as appendages to this letter - 2015 International Building Code and 2015 International Residential Code - 2017 Florida Building Code, 6th Edition and 2017 Florida Residential Code, 6th Edition - AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Modules, November 2012 by ICC-ES General Mounting System and Analysis Overview: The QRail Light consists of 6005-T5 (acceptable alternative materials include 6005A-T61 and 6061-T6) extruded aluminum per ASTM B221-08. The rails are used in pairs to support photovoltaic solar panels in order to span between points of attachment to the existing roof structure. The following tables and information summarize the structural analysis performed by SEI in order to certify the QRail Light for the state noted above. The analysis for certification included the following parameters for each rail system. QRail Light: - Risk Category II - Roof Slopes up to 45 degrees - Portrait & Landscape orientation of photovoltaic panels - Max Module Dimensions = Varies, see tables  1815 W. Diehl Rd, Suite 100, Naperville, IL 60563 630-219-1997 (P) www.structuralenginuityinc.com   x Actual span lengths used must be within capacity of roof attachment and structural capacity of roof member supporting solar array. Conclusion and Certification Summary: Based on the structural analysis performed by SEI in regards to the loading parameters specified above for QRail Light, the following C1 through C39 QRail Span tables for the Quick Mount PV QRail Light System were determined. The various span information is controlled by the applicable wind and snow loads to the structure to which the array is being mounted on the roof and based on the roof zone to which the array is installed on the roof. The tables allow for multiple panel sizes and orientations as follows: Tables 1-6: 15 ft max mean roof height, panels in portrait orientation with a maximum length of 67.5” Tables 7-12: 15 ft max mean roof height, panels in landscape orientation with a maximum width of 42” Tables 13-21: 30 ft max mean roof height, panels in portrait orientation with a maximum length of 67.5” Tables 22-30: 30 ft max mean roof height, panels in landscape orientation with a maximum width of 42” Tables 31-39: 30 ft max mean roof height, panels in portrait orientation with a maximum length of 77” This letter is to certify that the loading criteria and design basis used for the structural analysis of the QRail Light PV Panel Racking System for the span tables attached is validated and performed in compliance with the 2015 International Building Code and 2015 International Residential Code and the 2017 Florida Building Code, 6th Edition and 2017 Florida Residential Code, 6th Edition. Please contact our office if you have any further questions relating to this matter. Sincerely, Peter Martin Allan T. Myket, S.E. Engineer III President/Founder pmartin@structuralenginuityinc.com amyket@structuralenginuityinc.com Structural Enginuity Inc. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ALLAN T. MYKET, PE ON 8/2/2018 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FL COA No. 30952 Licensee Name: Allan T. Myket Registration No. 778578/2/2018 BI 7.2.3-46May-2018, Rev 2BI 7.2.3-46May-2018, Rev 2308. List of UL2703 Approved ModulesManufacturerModelAxitecAC-xxxA/60B(S), AC-xxxA/72BNote: A = P, M; B = X, V, XV, MXBovietBVM6610P-xxx, BVM6610M-xxx , BVM6612P-xxx, BVM6612M-xxxCanadian SolarCS6P-xxx, CS3U-P, Cs3U-MS, CS3K-P CS3K-MS, CS3K-MS, CS6K-xxxMS, All-BLACK CS6K-xxxMS, CS6U-xxxM, 1500V CS6U-xxxM, CS6U-xxxP, 1500V CS6U-xxxP, CS6X-xxxP, ALL-BLACK CS6K-xxxM, CS6K-xxxM, 1500V CS6K-xxxM, CS6K-xxxP, 1500V CS6K-xxxP, CS6P-xxxP, CS3U-P, CS3U-MS, CS3K-P, CS3K-MS, CS6K-xxxMS, All-BLACK CS6K-xxxMS, CS6U-xxxM, 1500V CS6U-xxxM, CS6U-xxxP, 1500V CS6U-xxxP, CS6X-xxxP, ALL-BLACK CS6K-xxxM, CS6K-xxxM, 1500V CS6K-xxxM, CS6K-xxxP, 1500V CS6K-xxxP, CS6P-xxxPCertainteedCTxxxMXX-02, CTxxxMXX-03ConergyPowerPlus xxxET SolarET-M660xxxBB, ET-M660xxxWW/WB, ET-P660xxxBB, ET-P660xxxWW/WBGigawatt Inc.GW-xxxPB, GW-xxxMBHanwha Q Cell60 Cell: Q.PEAK DUO-G5 xxx, Q.PEAK DUO BLK-G5 xxx, Q.PEAK G4.1 xxx, Q.PEAK BLK-G4.1 xxx, Q.PEAK-G4.1/MAX xxx, Q.PEAK-G4.1/TAA xxx, Q.PEAK BLK G4.1/TAA xxx, Q.PLUS G4 xxx, Q.PLUS BFR G4.1 xxx, Q.PLUS BFR G4.1/MAX xxx, Q.PLUS BFR G4.1/TAA xxx, Q.PRO G4 xxx, Q.PRO BFR G4 xxx, Q.PRO BFR 4.1 xxx, Q.PRO BFR 4.3 xxx, Q.PRO EC-G4.4 xxx, B.LINE PLUS BFR G4.1 xxx, B.LINE PRO BFR G4.1 xxx72 Cell: Q.PEAK DUO L-G5.2, Q.PEAK L G4.2 xxx, Q.PLUS L G4.2 xxx, Q.PLUS L G4.1 xxx, Q.PLUS L G4 xxx, Q.PRO L G4 xxx, Q.PRO L G4.1 xxx, Q.PRO L G4.2 Xxx, B.LINE PLUS L G4.2 xxx, B.LINE PRO L G4.1 xxx, B.LINE PRO L G4.2 xxx, Q.PLUS L G4.2 xxxHeliene60P, 60M(-BLK), 72P, 72MHyundaiHiS-AxxxB, HiS-AxxxB (BK), HiS-AxxxC Note: A = S, M; B = RG, TG, KG; C = RI, TI, KIItekIT-xxx-SE, IT-xxx-SE-72JA SolarJAP6(K)-60-xxx/4BB(1500), JAP60S01-xxx/SC, JAMP6(K)-60/PR(1500), JAMP60201-xxx/PR, JAP(K)-72-xxx/4BB(1500), JAP72S01-xxx/SC, JAM6(K)-72/PR(1500), JAM72S01-xxx/PRJinkoJKMxxxP-60, 60 JKMxxx-P-60, 60 JKMxxx-P-60B, 60 JKMxxxPP-60, 60 JKMxxxPP-60B, PERC 60 JKMxxxM-60, Plus JKMxxxPP-60(Plus), JKMxxxP-60-J4, JKMxxxP60B-J4, Black JKMxxxPP-60-J4, JKMxxxPP60B-J4, 1500V 60 JKMxxxPP-60-V, 1500V 60 JKMxxxM-60-V, Jinko MX60 JKMSxxxP, MX JKMSxxxPP-60, JKMxxxM-60B, JKMxxxM-60-J4, JKMxxxM60B-J4, JKMSxxxP-60, JKMSxxxP-60-J4, JKMSxxxM-60, JKMSxxxM-60-J4, JKMSxxxPP-60-J4, JKMSxxxPP-60, JKMSxxxM-60B-EP, 72 cell modules model: JKMXxxP-72, JKMxxxP-72B, JKMxxxP-72-J4, JKMxxxP-72B-J4, JKMxxPP-72, JKMxxxPP-72B, JKMxxxPP-72-J4, JKMxxxPP-72B-J4, JKMxxxPP-72(Plus), JKMxxxPP-72-V, JK-MxxxM-72, JKMxxxM-72B, JKMxxxM-72B-J4, JKMxxxM-72-J4, JKMxxxM-72-V, MX JKMSxxxPP-72Note: xxx refers to the power class in watts (W) of the module. The QRail system is to be used only with modules on this list or with those which include the QRail system in their respective installation manuals.QRail™ System Approved Moduleswww.quickmountpv.com | 925-478-8269 RESPECT THE ROOFMay2018QRail™ System Approved Moduleswww.quickmountpv.com | 925-478-8269 RESPECT THE ROOFMay2018BI 7.2.3-46May-2018, Rev 231ManufacturerModelLGLGxxxF1G-A5, LGxxxQ1G-A5Note: F = E, N, S; G = any letter in the alphabetMission SolarMSExxxSO5K, MSExxxSO5T, MSExxxSO6J, MSEXxxSO4J, MSEXxxMM6J, MSEXxxSQ5K, MSEXxx-SQ5T, MSEXxxSQ6S, MSEXxxSQ4SPanasonicVBHNxxxSA17, VBHNxxxSA16(B), VBHNxxxSA15, VBHNxxxSA15B, VBHNxxxKA01, VBHNxxx-KA03/04RECREC TwinPeak 2 Series (BLK), RC TwinPeak 2 BLK2 Series, REC N-Peak, REC TwinPeak 2S 72 Series, REC TwinPeak 2S 72XV Series, REC TwinPeak 2S 72 BXV SeriesSeraphim Solar SRP-6MA, SRP-6PA, SRP-6MB, SRP-6MB-BB, SRP-6PBSilfabSLA X, SLA-M-xxx, SLA-P-xxx, SLG-P-xxx, SLG-M-xxx/SLG-X-xxx, SSA-Mxxx/SSA-P-xxx, SSG-M-xxx/SSG-P-xxx, SLA-M-xxx, SLG-M-xxx, SLA-X-xxx, SLG-X-xxx, SLA-P-xxx, SLG-P-xxx, SSA-M-xxx, SSG-M-xxx, SSA-P-xxx, SSG-P-xxxSolariaPowerXT-xxxR-ANote: A = AC, PD, BD, PX, BXSolar Tech Universal STU-xxx-PERC, STU-xxx-HJTSolarWorldSunmodule Plus SWxxx, Sunmodule Plus SWA xxx poly (black/clear), Sunmodule Plus SWA xxx mono (black/clear), Sunmodule SWA xxx XL mono (black/clear), Sunmodule SWA xxx XL poly (black/clear), Sunmodule Bisun SWA xxx XL duo (black/clear)Sonali SolarSS 230W to 265W-280W to 320WSunivaOPTxxx-60-4-1B0SunPowerSPR-X21-xxx, SPR-E20-xxx, SPR-E19-xxx, SPR-X21-xxx(BLK), SPR-E20-xxx, SPR-P17-xxx-COMSunSpark Technology SMX-xxxw, SST-xxxwTrinaTSM-PD05.08-xxx, TSM-PD14-xxx, ALLMAX-PD05.05, ALLMAX M Plus-DD05A.05 (II)-, ALL-MAX-PD05A.08, TSM-DD14A(II)-, TSM-DE14A(II)-YingliYL-xxx-35B, YL-xxx-29B, YLxxxP29b, YLxxxP-35bNote: xxx refers to the power class in watts (W) of the module. The QRail system is to be used only with modules on this list or with those which include the QRail system in their respective installation manuals.NOTE!When using Mid Clamps 0870, 0871, 0875, 0876, contact Quick Mount PV for copy of approved modules list for use with these clamps. ®www.roof-tech.us info@roof-tech.us RT-MINISelf-flashing base for asphalt & metal roof-top PV mounting systemsDual bolt design: M8 or 5/16” for L-Foot & 1/4” for EMC 1/4” Hex Boltupper channelEasy tappingscrew guideM8 or 5/16” Hex Boltbottom channelFlat lip for PV Cable clipsRT-MINI is suitable for mounting any rail system with a conventional L-Foot.Call Now for more details858-935-6064ICC ESR 3575RT-MINIFlexible Flashing certified by the International Code Council (ICC)ComponentsRT2-00-MINIBKMINI base : 20 ea.Screw : 40 ea.Extra RT-Butyl : 10 ea.RT-Butyl is Roof Tech s flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV mounting system with Flexible Flashing certified by the ICC.ICC ESR-3575 ASTM2140 testingUV testing (7500 hrs.)www.roof-tech.us info@roof-tech.us 10620 Treena Street, Suite 230, San Diego, CA 92131858.935.6064Roof Tech Inc.Flexible Flashing100% WaterproofMetal Flashing RetrofitShedding water?Ra"er installa#onDeck installa#on’P.E. Stamped Letters available at www.roof-tech.us/supportPAT : PENDINGDimensions in (mm)(DYH(DYHEngineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood)