HomeMy WebLinkAboutDelneky Load CalcsResidential Standard Calculation 9/25/1997 DELNEKY, AKOS
e,khnSaD< Version2011 L
STEP 1 Article 220.42 & 220.52
sq. tt 3322 General Lighting load
2 Small Appliance
1 Laundry circuit
Gen.Lgt, Sm App.& Laun. Load
STEP 2 Article 220.50 & 220.51 �
A/C Condenser & Fixed Electric Space Heating
3.5 ton
V
5,000 VA
AHU
1
10kW
.
SkW
Select V
Select V
Select
9,966
9,966
VA
3,000
VA
1,500
VA
14,466
VA
3,000
VA
@ 100%=
11,466VA
@ 35%=
VA
@ 25% =
QTY
111600 VA 1
5,800 VA 1
VA QtY
VA QtY
VA Qty
FPL HOME SERVICES
6001 VILLAGE BLVD
WEST PALM BCH 33407
561-747-5740
12/30/2020 10:15
3,000 VA
4,013 VA
VA
General Lighting Demand Load
Total 2
Heating Load
CU Load
17,400 VA
11,675 VA
Greater of Heat @ 100°/ vs.A/C @ 100%
7,013 VA
17,400 VA
STEP_ 3 Article 220.53 Appliance Demand Load 6,540 VA
4,500 VA V 1 Water Heater 41500 VA
1,400VA V 1 Refrigerator 11400 VA Dryer Demand Load 53000 VA
600VA V Freezer VA
030VA V 1 Dishwasher 1,030 VA Range Demand Load 83000 VA
690 VA 1 Disposal 690 VA
400 VA R / Hood VA Service Demand 435953 VA
1,10oVA 1 Microwave 1,100 VA
❑ 4,000VA Microwave VA Demand Load 183 A
170VA Mini Refrig VA
❑ 400 VA Wine Clr VA Neutral Demand 80 A
❑ 5,000vA Insta Hot VA
1,500 VA Ironing Center VA Min.Service Req. 200 A
IS select V Jacuzzi Tub VA
❑ select • Sprinkler Pump VA Min. Feeder size 210
❑ select V Well Pump VA Min. Neutral size 4
select Fountain Pump VA Eq. Grding Cond. 6
select Elevator VA ❑ Copper
Pool Equip. Panel VA 100% Demand
❑ 0 GATES VA No Demand
❑ 0 Other load VA No Demand Total Appliance Load 89720 VA
4 or more demand @ 75% plus 100% demand loads 6,540 VA
STEP 4 Article 220.54
Electric Clothes Dryers 53000 VA
STEP 5 Article 220.55
Electric Ranges 8,000 W Col C demand 8000
or Number of appliances
Cooktop
Col
B
demand
❑Check Box for Gas Range Cooktop
Col
B
demand
Oven(s)
Col
B
demand
Oven(s)
Col
B
demand
Number of appliances
0 Dem. Factor
0%
Cooktop
& Oven Demand Load
W
Pool Panel Feeder Calculation
Continuous Motors
Non -continuous
0
0
(See Note)
......
......
A
B
N
0
0
0
0
0
0
select
Max.Unbal
Non -continuous
Motors
(select � ❑ 24ov
select El 24ov
select �
El 24ov
El 24ov
❑ 24ov
select �
select
0.0 Motor Neutral Load
Public State of Florida
` � � ` ,per My Commission GG 914855