Loading...
HomeMy WebLinkAboutAPPROVED, Architect letterArchitectonic Inc St. Lucie County Planning & Development Services Building and Code Regulation Division January 4, 2021 RE: 179 Ocean Bay Drive To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2020 Florida Building Code, 170 mph wind zone, exposure "C", risk category ll. From Table 1609.3.1: Vu,t= 165mph V,,d = 128mph From Table 1609.6(1): 16' 2" h x 8' door,165mph = +21.8/-24.3 From Table 1609.6(2): 30' mean roof height, Exposure C =1.40 Required Design Pressures: 21.8 x 1.40 = 30.5 24.3 x 1.40 = 34.1 Product: Steel Pan 04 W6-W16 Pan-2F153 Double Car 4" Clopay Building Products FL# 16546.4 Product Pressures: +36 & -42 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1