Loading...
HomeMy WebLinkAboutTruck Country SET-SLDPREPARED FOR: NOTE: CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS. CONTACT WHE FOR ANY MAJOR DISCREPANCIES. 0 0 v Nm :f f WALL TYPE LEGEND EI III Q 0 LI III Q ❑ 11 EXISTING 8" CMU WALL EXISTING FLOOR PLAN 1/4 II = 1 '-011 DOOR SCHEDULE # SIZE DESCRIPTION REMARKS �A 3068 GLAZED EXT. DOOR ® 6068 DOUBLE GLAZED EXT. DOOR © 3068 EXT. STEEL DOOR �D 3068 HOLLOW INT. DOOR E] 4068 STEEL SAFE DOOR 0 0 v GENERAL NOTES 1. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR SHALL REVIEW THESE DRAWINGS IN THEIR ENTIRETY BEFORE COMMENCING CONSTRUCTION AND SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED IMMEDIATELY IN WRITING TO THE WHOLE HOUSE ENGINEERING, LLC. BACK CHARGES WILL NOT BE ACCEPTED. 2. THE GENERAL CONTRACTOR SHALL VERIFY THE BUILDING POSITION WITHIN THE SETBACK LINES PRIOR TO COMMENCING CONSTRUCTION. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BE FAMILIARIZED WITH ALL EXISTING CONDITIONS AS THEY ARE NOT NECESSARILY SHOWN ON THESE DRAWINGS. 4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATIONS OF ALL FLOOR, ROOF, AND WALL OPENINGS AND PENETRATIONS. 5. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO COORDINATE THE WORK OF ALL TRADES, DETERMINE ERECTION PROCEDURE, AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING, ITS COMPONENTS, AND TRADE BASE DURING CONSTRUCTION. 6. ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR CONDITION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL AND OR SECTION IS SHOWN. 7. BUILDER IS RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL OR NON-STRUCTURAL MEMBERS DURING CONSTRUCTION. 8. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PROVIDE ALL NECESSARY SHOP DRAWINGS, WINDOWS, DOORS, ETC. TO WHOLE HOUSE ENGINEERING, LLC FOR REVIEW AND APPROVAL. 9. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED. 10. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF WHOLE HOUSE ENGINEERING, LLC., AND SHALL NOT BE USED OR REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC. 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING AND TRADE PERMITS AND FOR THEIR RESPECTIVE COSTS. 12. THESE DRAWINGS ARE DIAGRAMMATICAL AND ARE INTENDED TO SHOW DESIGN INTENT ONLY. THEY DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION. ALL TRADES ARE RESPONSIBLE FOR FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT WOULD NORMALLY BE CONSIDERED INCIDENTAL TO THEIR INSTALLATION. FLOOR PLAN NOTES 1. FIRE BLOCKING. PROVIDE FIRE BLOCKING AT ALL CONCEALED SPACES. 2. SHUTTERS. STORM SHUTTERS WITH AN ACCEPTED PRODUCT APPROVAL SHALL BE PROVIDED AT ALL OPENINGS EXCEPT THOSE PROTECTED BY APPROVED IMPACT RESISTANT DOORS AND WINDOWS. 3. ROUGH OPENINGS. VERIFY ALL ROUGH OPENING AND MASONRY OPENING SIZES WITH MANUFACTURER'S PRODUCT SPECIFICATIONS. 4. INTERIOR NON -BEARING WALLS. 25 GA., 3.5" STEEL STUDS @ 24" O.C. (20GA. @ 16- O.C. IN AREAS RECEIVING TILE AND WET AREAS) W/ 1 /2" GYPSUM BOARD ON BOTH SIDES (TYPICAL). 2X4 P.T. SILL PLATE FASTENED TO SLAB -ON -GRADE BELOW WALL. 5. BATHTUB AND SHOWER SPACES. BATHTUB & SHOWER FLOORS & WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS & IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH AN IMPERVIOUS, NON -CORROSIVE, NON -ABSORBENT & WATERPROOF MATERIAL. MOISTURE RESISTANT BACKING BOARD REQUIRED UNDER IMPERVIOUS WALL AREAS IN BATH TUB & SHOWER SPACES. SUCH WALL SURFACES SHALL EXTEND NOT LESS THAN 6'-0" ABOVE THE ROOM FLOOR LEVEL. 6. EXTERIOR OPENINGS. NO OPENINGS ARE PERMITTED IN THE EXTERIOR WALL OF BUILDINGS SEPARATED FROM ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6'-011 . 7. BACKING FOR CABINETS. PROVIDE 2X4 MINIMUM HORIZONTAL BACKING IN KITCHEN W/ TOP @ 35" A.F.F. & TOP @ 8'-0" A.F.F. & IN BATHROOM VANITY AREAS W/ TOP @ 30" A.F.F. OR AS REQUIRED FOR CABINET ATTACHMENT. 8. SAFEGUARDS. WHERE THERE IS A DROP OF MORE THAN 4 FEET OR MORE ON THE FAR SIDE OF THE OPERABLE OR FIXED GLAZED PANELS 24" OR GREATER IN WIDTH AND THE SILL IS LESS THAN 36" ABOVE THE NEAR SIDE WALKING SURFACE, SAFEGUARDS SHALL BE PROVIDED AS SET FORTH IN 4403.7.3. WINDOW SCHEDULE # SIZE DESCRIPTION REMARKS lO 55" x 50" FIXED GLASS WINDOW O2 60" X 50" FIXED GLASS WINDOW MICHAEL LASITER 253 PATTERSON AVE FORT OGLETHORPE, GA 30742 a Digitally signed by Rama Pranav Kristam DN: E=rama.kristam@whengineering.net, CN=Rama Pranav Kristam, O=Whole House Engineering LLC, L=Fort Pierce, S=Florida, C=US Reason: I have reviewed this document Date. 2020.11.30 10:57:38-05'00' WHOLE HOUSE ENGINEERING 4451 ST. LUCIE BLVD, SUITE 201 FORT PIERCE, FL 34946 CONTACT: 772.409.1003 ENGINEERING@ W HENGINEERING. NET COPYMGHT©2016 WHOLE HOUSE ENGINEERING, LLC. DRAWING NOTICE: THESE DRAWINGS AND DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF WHOLE HOUSE ENGINEERING, LLC. AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC. WARNING: DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. ARCHITECTURAL SYMBOLS CONTAINED WITHIN THESE DOCUMENTS ARE FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY IN ORDER TO MEET THE MANUFACTURER'S SPECIFICATIONS. ENGINEER'S SIGNATURE & SEAL: RAMA P. KRISTAM, P.E. FL #88906 �`�`. •��CENSF. `S'J.�%% * No. 88906 STATE OF %SS/ON REVISIONS LIST PERMIT SET 11 1 /30/20IRBI - PROJECT INFORMATION: 10151 TRUCK COUNTRY 5130 N US HIGHWAY 1 FORT PIERCE, FL 34946 DRAWN BY: RB CHECKED BY: RAMA P. KRISTAM, P.E. SHEET TITLE: XISTING FLOOR PLAN SHEET NO.: EXIST. INT. NON BEARING WALL A-1.0 NOTE: CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS. CONTACT WHE FOR ANY MAJOR DISCREPANCIES. PREPARED FOR: MICHAEL LASITER NEW FLOOR PLAN 1/4 If /4If= 1 1-0" WALL TYPE LEGEND EI III Q D LI III Q D 11 EXISTING 8" CMU WALL DOOR SCHEDULE # SIZE DESCRIPTION REMARKS �A 3068 GLAZED EXT. DOOR ® 6068 DOUBLE GLAZED EXT. DOOR © 3068 EXT. STEEL DOOR F-D 3068 HOLLOW INT. DOOR �E 4068 STEEL SAFE DOOR WINDOW SCHEDULE # SIZE DESCRIPTION REMARKS lO 55" x 50" FIXED GLASS WINDOW OD 60" X 50" FIXED GLASS WINDOW 253 PATTERSON AVE FORT OGLETHORPE, GA 30742 WHOLE HOUSE ENGINEERING 4451 ST. LUCIE BLVD, SUITE 201 FORT PIERCE, FL 34946 CONTACT: 772.409.1003 ENGINEERING@ WHENGINEERING. NET COPYRIGHT© 2016 WHOLE HOUSE ENGINEERING, LLC. DRAWING NOTICE: THESE DRAWINGS AND DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF WHOLE HOUSE ENGINEERING, LLC. AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC. WARNING: DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. ARCHITECTURAL SYMBOLS CONTAINED WITHIN THESE DOCUMENTS ARE FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY IN ORDER TO MEET THE MANUFACTURER'S SPECIFICATIONS. ENGINEER'S SIGNATURE & SEAL: RAMA P. KRISTAM, P.E. FL #88906 NNA V *� No.88906 STATE OF .40R1D.•'Gn�. SSI4NiAO\ REVISIONS LIST PERMIT SET 1 1 /30/20 RB - PROJECT INFORMATION: 10151 TRUCK COUNTRY 5130 N US HIGHWAY 1 FORT PIERCE, FL 34946 DRAWN BY: RB CHECKED BY: RAMA P. KRISTAM, P.E. SHEET TITLE: NEW FLOOR PLAN SHEET NO.: EXIST. INT. NON BEARING WALL A-2.0 PREPARED FOR: LIFE SAFETY LEGEND: MICHAEL LASITER EXIT SIGNAGE FIRE ALARM SPEAKER / STROBE BUILDING & LIFE SAFETY INFORMATION COMBO 253 PATTERSON AVE OCCUPANCY CALCULATIONS -OCCUPANCY CALSSIFICATION FBC 2017 CHAPTER 3, SECTION 303. SHALL COMPLY WITH FFPC 6TH ED. TABLE EXIT SIGNAGE AND EGRESS LIGHT EMERGENCY EXIT LIGHTS 101 AND NFPA 1/101 15. FORT OGLETHORPE, GA 30742 -B = BUSINESS (NOT MERCANTILE) FIRE EXTINGUISHER - SURFACE - NUMBER OF OCCUPANTS EXITING AREA SQ. FT./ OCCUPANCY -FIRE PROTECTION SYSTEM (SPRINKLERS) = NOT REQUIRED TYPE A COMPIANCE WITH NFPA 10 FROM ONE UNIT ROOM # ROOM GROUP (SQ. FT.) PERSON LOAD FIRE ALARM SYSTEM = NOT REQUIRED NUMBER OF OCCUPANTS EXITING -ALL EMERGENCY LIGHT FIXTURES ON BATTERY BACKUP RATED FOR 90 MINUTES. FROM SEVERAL UNITS 101 OFFICE 527 B 100 6 -EXIT DOORS WILL NOT HAVE ANY LOCK OR SPECIAL KNOWLEDGE TO OPERATE FROM EGRESS SIDE AS PER FFPC. D•F• DEFIBRILLATOR EXISTING PARTITION 102 BATH 24 B 100 1 O SMOKE DETECTOR - NEW PARTITION 103 OFFICE 1741 B 100 18 CONSTRUCTION TYPE: VB YEAR BUILDING BUILT: 1987 MULTI STATION HARDWIRED 1-HR FIRE RATED SEPARATION 104 UTILITY 145 B 100 2 FLOORS: 1 123 L.F. 105 OFFICE 65 B 100 1 TENANTS IN BUILDING: 1 DEADEND CORRIDOR: 50'-0" MAX. PATH OF TRAVEL 106 STORAGE 396 S-1 200 2 MAX. TRAVEL DISTANCE: 200'-0" MAX. XX/XX REQUIRED/PROVIDED EGRESS WIDTH 107 BATH 30 B 100 1 EGRESS WIDTH: 36" MIN. HORIZ. FIRE SEPARATION: 2 HOUR 108 BATH 30 B 100 1 CEILING/ ROOF ASSEMBLY: 0 HOUR PREPARED BY: TOTAL BUILDING OCCUPANTS = 32 MINIMUM DOOR WIDTH: 32" MIN. CLEAR EXIT ACCESS CORRIDOR RATING: 1 HOUR MECHANICAL ROOM SEPARATION: 1 HOUR MAXIMUM CHANGE IN ELEVATION: 1 /2" MINIMUM NUMBER OF EXITS: 2 1 LIFE SAFETY PLAN -IO 1/4 If = 1 '-011 GENERAL NOTES: 1. DURING CONSTRUCTION AND WHILE OCCUPIED THE BUILDING SHOULD COMPLY WITH NFPA 1 16.4 SAFEGUARDS. 2. PROJECT IS CLASSIFIED WITH FFPC 101 5TH EDITION CHAPTER 43 BUILDING RECONSTRUCTION. 3. DOOR OPENING GOING INTO THE CORRIDOR SHALL COMPLY WITH FFPC 101 5TH EDITION 29.3.6.2.2. 4. ALL EXIT LIGHTS AND EMERGENCY LIGHTS SHALL HAVE A BATTERY BACKUP RATED FOR 90 MINUTES MINIMUM. SEE ELECTRICAL DRAWINGS. 5. FIRE EXTINGUISHEERS RATED "2-1" ABC TYPE SHALL BE FOR EACH 3,000 S.F. (ORDINARY HAZARD OCCUPANCY) W/ A MAXIMUM 75 FOOT OF TRAVEL DISTANCE. TOP OF EXTINGUISHER NOT TO EXCEED 5 FOOT ABOVE FINISHED FLOOR. 6. DOORS MUST BE OPENABLED WITH NO MORE THAN ONE RELEASING OPERATION. SUCH MECHANISM FOR ANY LATCH SHALL BE LOCATED 34" MIN AND 48" MAX ABOVE FINISHED FLOOR. 7. ILLUMINATE AND MARK MEANS OF EGRESS. 8. EMERGENCY LIGHTING TO BE PROVIDED. WHOLE HOUSE ENGINEERING 4451 ST. LUCIE BLVD, SUITE 201 FORT PIERCE, FL 34946 CONTACT: 772.409.1003 ENGINEERING@ W HENGINEERING. NET COPYMGHT©2016 WHOLE HOUSE ENGINEERING, LLC. DRAWING NOTICE: THESE DRAWINGS AND DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF WHOLE HOUSE ENGINEERING, LLC. AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC. WARNING: DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. ARCHITECTURAL SYMBOLS CONTAINED WITHIN THESE DOCUMENTS ARE FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY IN ORDER TO MEET THE MANUFACTURER'S SPECIFICATIONS. ENGINEER'S SIGNATURE & SEAL: RAMA P. KRISTAM, P.E. FL # 88906 oNA.� •��CENSF. Q : •. 9 * No. 88906 STATE OF %SS/ON W����`�� REVISIONS LIST PERMIT SET 11 1 /30/20IRBI - PROJECT INFORMATION: 10151 TRUCK COUNTRY 5130 N US HIGHWAY 1 FORT PIERCE, FL 34946 DRAWN BY: RB CHECKED BY: RAMA P. KRISTAM, P.E. SHEET TITLE: -IFE SAFETY PLAN SHEET NO.: A-3.0