Loading...
HomeMy WebLinkAboutPizzano letter-signed M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 To: St. Lucie County - Building & Code Regulation Division Date: December 11, 2020 Re: Maureen Pizzano 7380 S. Ocean Drive, Unit 918 (Middle unit) Jensen Beach, Fl. , 34957 It is acceptable to replace existing double hung window, picture window, sliding glass door openings and mullion bars for the address listed above with the units as follows: 1) D.H.- The PGT Window Systems "SH 5560" Impact PVC double hung window L.M.I. has a Miami Dade NOA #20-0401.06 The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +70 /-110 design pressure and has a small & large missile "D" approval and HVHZ. 2) P.W.- The PGT Window Systems "PW 5520A" Impact PVC picture window has a Miami Dade NOA #20-0401.16. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +80 /-100.0 design pressure and has a large missile "D" approval and HVHZ. This unit is located in a Zone 4. 3) S.G.D. - The PGT "5570/2770" series PVC S.G.D. has a Miami Dade NOA #20-0429.05. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +100 / -100 design pressure. It has a small and large missile "D" approval HVHZ. This unit is located in a Zone 4. 3) MULLION BARS - The Series "PGT" Clipped Extruded Aluminum Tube Mullion - has a Miami Dade NOA # 20-0406.03. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +170.0 /-170.0 design pressure and has a large & small missile "D" approval and HVHZ . This unit is located in a Zone 4. SCOPE OF WORK: New double hung & picture window, sliding glass door and mullion bar replacement. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1. DESIGN CODE: Florida Building Code Sixth Edition (2017) with 2020 Supplements using ASCE 7‐10 2. Structure Designed: Enclosed 3. Risk Category: II Exposure Category: D 4. Design Wind Velocity 170 mph End Zone Width: 4 ft 5. Mean Roof Height 153 ft Roof Pitch: 0:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: +58.7 / -63.7 P.S.F. & Zone 5: +58.7 / -78.5 P.S.F. Worst case scenario has been calculated. 7. Design Loads: Floor: N/A Roof/Dead: N/A Roof/Live: N/A Balcony: N/A Dock: N/A Deck: N/A Stairs: N/A Fence: N/A Railings: N/A 8. Were Shear Walls Considered For Structure? N/A Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? N/A 10. Design Soil Bearing Pressure: N/A Soil Test Reports Submitted? N/A Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A Corson Mark A. Corson A.I.A., NCARB President