HomeMy WebLinkAboutproduct approvalIWW2020 Florida Building Code Online
a 1 1 1 i r
aCIS Home i Log 1n User Registration iI Hot Topics i 5.bmlt 5ur0arge I Stats a Facts i Publications i C.rna Us , BCis Site Map Links Searrd
db'prr Product Approval
(li USER:Prod Pwblic User
J
Pmpuct gIQMyA Menus DOW= or AR&=on 5earch> 8 I Applioa lon 11
FL a Ft8248-R79
"" Application Type Revision
Code version 20 77
Application Status \ Approved
Comments 04/10/2020 v. date reapply04/13/20
Archived
Product Manufacturer Wayne -Dalton, a division of Overhead Door Corporation
Address/Phone/Email 3395 Addison Drive
Pensacola, FL 32514
(330)763-8121
d kornish @wayne-dalton.com
Authorized Signature Dwayne Komish
dkom ish@wayne-da Iton.com
Technical Representative Junfeng Q)an
Address/Phone/Email 2501 STX-121 BUS
Lewisville, TX 75067
(469) 549-7100
j unfeng_gian @ overheaddoor. com
Quality Assurance Representative Tony Rebitch
Address/Phone/Email 3395 Addison or
Pensacola, FL 32514
(850)475-6155
a nthony_rebitch @overheaddooccom
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the John E. Scates
Evaluation Report
Florida License
PE-51737
Quality Assurance Entity
Imertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date
12/3112020
Validated By
Jeffrey P. Arneson, P.E.
validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard) Standard
YAK
ANSI/DASMA-100
2012
ANSI/DASMA-108
2005
ANSI/DASMA-108
2017
ANSI/DASMA-115
2005
ANSI/DASMA-115
2017
ANSI/DASMA-115
2012
TAS-201
1994
https://www.0oridabuilding.org/prfpr_app_dU.aspx?pamm=wGEVXQwU)qujmeb8GbxRyWG4a6mWcHye8mlSgveRWrLSMiG2slkJKA%3d°!3d 116
1212912020
Florida Building Code Online
8248.5 18000/810018200 #1107
Limits of Use
Approved for use In HVHZ; No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +26.9/-30.8
Other: Impact Glazing is available. These Doors are not
intended for use in the High Velocity Hurricane Zone HVHZ.
8248.6 18000/8100/8200 #1108
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design. Pressure: +37.00/-41.I10
Other: Impact Glazing is available. These Doors are not
intended for use in the High Velocity Hurricane Zone HVHZ.
8248.7 18000/8100/8200 #1120
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +12.40/-13.80
Other: Glazing Is not impact resistant and does not meet the
requirements for wind-borne debris regions.
8248.8 1800018100/8200 #1121
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +15.30/-17.00
Other: Glazing is not impact resistant and does not meet the
requirements for wind-borne debris regions.
8248.9 1 8000/8100/8200 #1122
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design pressure: +23.00/-25.00
Other: Impact Glazing is available. These Doors are not
intended for use in the High Velocity Hurricane Zone HVHZ.
8248.10
Yes
9' Max width. 14' Max height. Glazing available in top or
intermediate section.
Installation Instructions 1
FL8248 R19 II 1i07-364232-P1 s pdf
FI 8248 R19 II 363342-P01 WD Jamb Connection
5gpplemenL sFL IL
FL8248 RIO II TraCkSuilWiMaotChartPll sFl -df
Verified By: John E. Scates 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL8248 R19 AE Eval Rept_$000 r18. s.pdf
Created by Independent Third Party: Yes
9' Max width. 14' Max height. Glazing available in top or
intermediate section.
Installation Instructions
FL8248 R12 JI 110$-364233-P1 s.pdf
FL8248 R19 li 363342 POI WD Jamb Connection
ipolement s& pdf
FL8248 R19 II TackSuonlemen[ChaRPli sFLpdf
Verified By: John E. Scates 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL8248 R19 AE Evai Rept 8000 r18 s. pdt
Created by Independent Third Party: Yes
16' Max width. 14' Max height. Glazing available in top or
intermediate section.
Installation Instructions
FL8248 R19 TI Y120.37aZ0, 47 PS s.odf
FL8248 _R19 It 363342-POl WD Jamb Connection
Sllppigment sFL.PAC
FL8248 R19 II TraCkSupniementQ0rtP11 sFL.pdf
Verified By: John E. Scates FL PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL8248 R19 AE Eva[ R<_nt 8008. r18 s p
Created by Independent Third Party: Yes
16' Max width. 14' Max height. Glazing available in tap or
intermediate section.
Installation Instructions
FL8248 R19 11 1121-327015-157 s.pdf
FL8248 R19 II 363342-POI WD Jamb Connection
£upplement sFL. pdf
FL8248 Rig 1L 1"rack9uppiementChartP11 _L.odf
Verified By: John E. Scates FLORIDA PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
Party: Yes
16' Max width. 14' Max height. Glazing available in top or i
Intermediate section.
Installation Instructions
FL8248 R19 II 1122-327016-P8 s p„df
FL8248 R19 II 363342-P01 WD Jamb Connection
5upalement sFL. pdf
FL8248 R19 11 TackBuppl mentChartP1Y sFL pdf
Verified By: John E. Scates FL PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL8248 R15 AE Fval Rept 8000 r18 s.0� I
Created by Independent Third Party: Yes
16' Max width. 14' Max height. Glazing available in top or
Intermediate section.
�App
Installation Instructions
use m HVMZ:Fl8248 R19 lI 1123-327017-P7 s ndf
use o e HVHZ: Fy824B R19 II 363342 POl WD lamb Connection
Impact Resistan as i SLJPPlement sFLRdf
Design Pressur : +30.00/-33.50, 1 FL8248 R19 II Tracks L lementChartP71 5.FL Pdf
Other: Verified By: John E. Scates FL PF $1737
Created by Independent Third Party: Yes
Evaluation Reports
httpsa/www.fbridabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXovrtDqujmebBGbxRyW G4a8m WCNy58ml8gvaRW rL8MiG251kJKA°l 3d%3d
#1123
3/6