HomeMy WebLinkAboutDrawing Jan.06.2021 02:27 PM DuBois Electric MD Corp 7727771846 PAGE. 4/ 7
Steve Foor
13328 NW Baywood Place
Palm City, Fl. 34990
D]Homeline
150 Amp
Meter Main
(2) 150 amp
Main Breakers
❑D Homellne
150 Amp LP
Nr=MA 14-50
1.)Add 50 amp 250 volt circuit for Tesla.
2.) Install NEMA 14-50 outlet.
3.)Run#6 THHN in 3/4"PVC conduit
from Panel to outlet.
4.) Install 50 amp 250 volt Homellne
Breaker.
r
Jan. 06.2021 02 :27 PM DuBois Electric MD Corp 7727771846 PAGE. 5/ 7
Questions?Contact the Testa Technical Support Team:
Charginglnstallation@IeSl8MOtOrS.COni 1050.681.6133(Monday-Friday)1 677.7913.3752(2417)
INSTALLING; YOUR 240 VOLT OUTLET
The recommended home charging irlataliation for Tesla vehicles Is a 240 volt NEMA 14-
50 outlet,This outlet is commonly used for electric ranges and large recreational
vehicles,Installed with a 50 amp circuit breaker,this Outlet enables a recharge rate of
about 25 miles per hour,
Consult a licensed electrician to review the electrical load of your home prior to ,
installation.They will design your charging system and obtain a permit for a general
purpose NEMA 14-50 outlet from yotlr local building department.After installation,the
electrician will schedule an inspection to approve the now electrical virCuit and design.
This guide provides reference for specifications to install this outlet.Since each ~�
installation is olistom to the home,all hardware for the NEMA 1 h-50 outlet will be
provided by your electrician,
GROUND TO TOP
NEMA 14-50 DETAILS
•Voltage:Single phase,208-250 Volt AC supply,60 Hertz
• Circuit Breaker:50 Amp(125%overcurrent protection)
G . Operating Current:40 Amp(maximum continuous current)
• Conductors:6 AWG,Copper Wire Only,Upsize wiring for installations over 150 feet
250V . Ground Fault Circuit Interrupter:Not required
`' ' • Service Disiconnect:Not required
• Receptacle Recommendation:High quality,industrial grade recoptarle
• Ventilation:Not required
• Outdoors:Install with NEMA 3R rainproof enclosure
RECOMMENDED OUTLET LOCATIONS FOR YOUR RECORDS
ELECTRICAL COMPANY
PHONE NUMrIE,RV--
rl •
EMAIL ADDPF55
I I
' •"" (11„I L1.I:• PEt7MIT NVMARR
Install near vehicle charge port,maximurn 15'away,minimum 1t7"Hbovk�Around INSTALLATION onrE —
T;S L r, 3500 Deor Crook,Palo Alto,CA 943041 November,2015 1 Version 1.5
Jan. 06.2021 02:27 PM DuBois Electric MD Corp 7727771846 PAGE. 6/ 7
Project Name: Steve Foor Dryer
Project Type: (one-Family Dwelling (220.54, Table 220.54)
_ Dryers (Sum Total): 5000 VA
Phases Ampacity: 170 A Number of Dryers: 1
Neutral Ampacity (derated): 76 A Totals:
Phases (derated): 5000 VA
Service Voltage: 240 V Single Phase Neutral (derated): 3500 VA
Total Phases Load: 40816 VA
Total Neutral Load: 18253 VA Cooking Equipment
(220.55; Informational Notes)
General Lighting Column A (Sum Total): 3200 VA
(Table 220.12) Number of Appliances (Column A): 1
Column B (Sum Total): 8000 VA
Area: 3577 sq ft Number of Appliances (Column B): 1
Small Appliances: 3000 VA Column C (Sum Total): 0 VA
Laundry: 1500 VA Number of Appliances (Column C): 0
Totals: Totals:
Phases: 6231 VA Phases (derated): 8960 VA
Neutral: 6231 VA Neutral (derated): 6272 VA
Fixed Appliances Heating or A/C
(220,53) (220,60)
Dishwasher: 1500 VA Heating Unit: 15000 VA
Neutral: Yes
Disposer: 1500 VA Totals:
Neutral: Yes Phases: 15000 VA
Water Heater: 4500 VA Neutral: 0 VA
Neutral: No
Totals:
Phases (derated): 5625 VA
Neutral (derated): 2250 VA
This E-mail was generated on
12/27/2020 using the Electrical Load
Calculator by American Technical
Publishers, Inc.
Jan.06.2021 02:28 PM DuBois Electric MD Corp 7727771846 PAGE. 7/ 7
Project Name: Steve Foor Dryer
Project Type: One-Family Dwelling (220.54; Table 220.64)
Dryers (Sum Total): 5000 VA
Phases Ampacity: 194 A Number of Dryers: 1
Neutral Ampacity (derated): 100 A Totals:
Phases (derated): 5000 VA
Service Voltage: 240 V Single Phase Neutral (derated): 3500 VA
Total Phases Load: 46516 VA
Total Neutral Load: 23953 VA Cooking Equipment
(220.55; Informational Notes)
General Lighting Column A (Sum Total): 3200 VA
(Table 220.12) Number of Appliances (Column A): 1
Column B (Sum Total): 8000 VA
Area: 3577 sq ft Number of Appliances (Column B): 1
Small Appliances: 3000 VA Column C (Sum Total): 0 VA
Laundry: 1500 VA Number of Appliances (Column C): 0
Totals: Totals:
Phases: 6231 VA Phases (derated): 8960 VA
Neutral: 6231 VA Neutral (derated): 6272 VA
Fixed Appliances Heating or A/C
(220.53) (220.60)
Dishwasher: 1500 VA Heating Unit: 16000 VA
Neutral: Yes
Disposer: 1500 VA Totals:
Neutral: Yes Phases: 15000 VA
Water Heater: 4500 VA Neutral: 0 VA
Neutral: No
Nema 14 50 Outlet: 7600 VA
Neutral: Yes This E-mail was generated on
Totals: 12/27/2020 using the Electrical Load
Phases (derated): 11325 VA Calculator by American Technical
Neutral (derated): 7950 VA Publishers, Inc.
i