Loading...
HomeMy WebLinkAboutDrawing Jan.06.2021 02:27 PM DuBois Electric MD Corp 7727771846 PAGE. 4/ 7 Steve Foor 13328 NW Baywood Place Palm City, Fl. 34990 D]Homeline 150 Amp Meter Main (2) 150 amp Main Breakers ❑D Homellne 150 Amp LP Nr=MA 14-50 1.)Add 50 amp 250 volt circuit for Tesla. 2.) Install NEMA 14-50 outlet. 3.)Run#6 THHN in 3/4"PVC conduit from Panel to outlet. 4.) Install 50 amp 250 volt Homellne Breaker. r Jan. 06.2021 02 :27 PM DuBois Electric MD Corp 7727771846 PAGE. 5/ 7 Questions?Contact the Testa Technical Support Team: Charginglnstallation@IeSl8MOtOrS.COni 1050.681.6133(Monday-Friday)1 677.7913.3752(2417) INSTALLING; YOUR 240 VOLT OUTLET The recommended home charging irlataliation for Tesla vehicles Is a 240 volt NEMA 14- 50 outlet,This outlet is commonly used for electric ranges and large recreational vehicles,Installed with a 50 amp circuit breaker,this Outlet enables a recharge rate of about 25 miles per hour, Consult a licensed electrician to review the electrical load of your home prior to , installation.They will design your charging system and obtain a permit for a general purpose NEMA 14-50 outlet from yotlr local building department.After installation,the electrician will schedule an inspection to approve the now electrical virCuit and design. This guide provides reference for specifications to install this outlet.Since each ~� installation is olistom to the home,all hardware for the NEMA 1 h-50 outlet will be provided by your electrician, GROUND TO TOP NEMA 14-50 DETAILS •Voltage:Single phase,208-250 Volt AC supply,60 Hertz • Circuit Breaker:50 Amp(125%overcurrent protection) G . Operating Current:40 Amp(maximum continuous current) • Conductors:6 AWG,Copper Wire Only,Upsize wiring for installations over 150 feet 250V . Ground Fault Circuit Interrupter:Not required `' ' • Service Disiconnect:Not required • Receptacle Recommendation:High quality,industrial grade recoptarle • Ventilation:Not required • Outdoors:Install with NEMA 3R rainproof enclosure RECOMMENDED OUTLET LOCATIONS FOR YOUR RECORDS ELECTRICAL COMPANY PHONE NUMrIE,RV-- rl • EMAIL ADDPF55 I I ' •"" (11„I L1.I:• PEt7MIT NVMARR Install near vehicle charge port,maximurn 15'away,minimum 1t7"Hbovk�Around INSTALLATION onrE — T;S L r, 3500 Deor Crook,Palo Alto,CA 943041 November,2015 1 Version 1.5 Jan. 06.2021 02:27 PM DuBois Electric MD Corp 7727771846 PAGE. 6/ 7 Project Name: Steve Foor Dryer Project Type: (one-Family Dwelling (220.54, Table 220.54) _ Dryers (Sum Total): 5000 VA Phases Ampacity: 170 A Number of Dryers: 1 Neutral Ampacity (derated): 76 A Totals: Phases (derated): 5000 VA Service Voltage: 240 V Single Phase Neutral (derated): 3500 VA Total Phases Load: 40816 VA Total Neutral Load: 18253 VA Cooking Equipment (220.55; Informational Notes) General Lighting Column A (Sum Total): 3200 VA (Table 220.12) Number of Appliances (Column A): 1 Column B (Sum Total): 8000 VA Area: 3577 sq ft Number of Appliances (Column B): 1 Small Appliances: 3000 VA Column C (Sum Total): 0 VA Laundry: 1500 VA Number of Appliances (Column C): 0 Totals: Totals: Phases: 6231 VA Phases (derated): 8960 VA Neutral: 6231 VA Neutral (derated): 6272 VA Fixed Appliances Heating or A/C (220,53) (220,60) Dishwasher: 1500 VA Heating Unit: 15000 VA Neutral: Yes Disposer: 1500 VA Totals: Neutral: Yes Phases: 15000 VA Water Heater: 4500 VA Neutral: 0 VA Neutral: No Totals: Phases (derated): 5625 VA Neutral (derated): 2250 VA This E-mail was generated on 12/27/2020 using the Electrical Load Calculator by American Technical Publishers, Inc. Jan.06.2021 02:28 PM DuBois Electric MD Corp 7727771846 PAGE. 7/ 7 Project Name: Steve Foor Dryer Project Type: One-Family Dwelling (220.54; Table 220.64) Dryers (Sum Total): 5000 VA Phases Ampacity: 194 A Number of Dryers: 1 Neutral Ampacity (derated): 100 A Totals: Phases (derated): 5000 VA Service Voltage: 240 V Single Phase Neutral (derated): 3500 VA Total Phases Load: 46516 VA Total Neutral Load: 23953 VA Cooking Equipment (220.55; Informational Notes) General Lighting Column A (Sum Total): 3200 VA (Table 220.12) Number of Appliances (Column A): 1 Column B (Sum Total): 8000 VA Area: 3577 sq ft Number of Appliances (Column B): 1 Small Appliances: 3000 VA Column C (Sum Total): 0 VA Laundry: 1500 VA Number of Appliances (Column C): 0 Totals: Totals: Phases: 6231 VA Phases (derated): 8960 VA Neutral: 6231 VA Neutral (derated): 6272 VA Fixed Appliances Heating or A/C (220.53) (220.60) Dishwasher: 1500 VA Heating Unit: 16000 VA Neutral: Yes Disposer: 1500 VA Totals: Neutral: Yes Phases: 15000 VA Water Heater: 4500 VA Neutral: 0 VA Neutral: No Nema 14 50 Outlet: 7600 VA Neutral: Yes This E-mail was generated on Totals: 12/27/2020 using the Electrical Load Phases (derated): 11325 VA Calculator by American Technical Neutral (derated): 7950 VA Publishers, Inc. i