Loading...
HomeMy WebLinkAboutSoil Exploration - Proposed Tarpon Flat Site WallFlorida's Leading Engineering Source - Geotechnical • Construction Materials Testing - Threshold and Special Inspections • Plan Review & Code Compliance "FRNATO"' Tarpon Flats, LLC 277 Royal Poinciana Way, Suite 156 Palm Beach, Florida 33480 RE: Soil Exploration - Proposed Tarpon Flats Site Wall Vicinity SW of Bonita Isle Dr. & A1A, St. Lucie County, FL GFA Project # 13-2092.03 GFA International performed soil testing with three auger borings with hand cone penetrometers at the above referenced project. Based on the test results, the soil on which the referenced structure is to rest is capable of sustaining a safe bearing capacity of 2,500 psf. The subsurface exploration activities were performed in accordance with Chapter 18 ,of the Florida Building Code (latest addition) and applicable ASTM standards. For detailed information on subsurface conditions encountered, please refer to the logs attached to this letter. We recommend that the bottom of the footings be founded at a depth of at least 12 inches below finish grade. The depth shall be measured from the lowest adjacent grade. We also recommend a minimum footing width of 18 inches for spread footings and 16 inches for monolithic footings, but not less than 8 inches more than the width of the imposed wall. This report does not state or imply that the foundation soils at the bearing level will remain in the original condition in which they were found during the subsurface exploration activities. Exposure to the environment may weaken the,foundation soils at the bearing level if the foundation excavations remain open for a long period of time, or if the foundation soils are exposed to rainfall. Consequently, it is recommended that the excavations for the wall and column footings be performed to final grade and footings constructed -as soon as possible to minimize potential damage of the bearing soils. GFA estimates that 0 — 1 foot of fill will be required to bring the foundation pad to design grade. It is also recommended that the 2 feet below existing grade, the bottom of all new footing excavations and slabs, and all fill material, be compacted to a minimum density of 95% of the Modified Proctor (ASTM D-1557), prior to the placement of the concrete for the footings. Foundations and any below grade remains of any structures that are within the footprint of the new construction should be removed so as to not affect structures. Analysis of the foundation performance under hurricane conditions or other storm events, including the effects of loss of soil support due to scour or other forces, is not within the scope of this report, and the recommendations are valid only for normal conditions. Sincerely, GFA FB,F�'�6J�,� a •. yp '�, yS90, aid W. Mo'r,' P -`' Craig A. Hampy, E.I. ��ilt3r Geotec,�ca�r Staff Engineer 3SN�•'pN��`� •....... Zp&ft elation Plan, Auger Boring (AB) Logs (3), Notes Related to Test Borings Copies: " 11111oq 521 NW Enterprise Drive • Port St. Lucie, Florida 34986 • (772) 924.3575 • (772) 924.3580 (fax) • www.teamgfa.com OFFICES THROUGHOUT FLORIDA c C� F9 V 4 ,Q� `S rtSnrvG ••u Test Location Plan Proposed Tarpon Flats Site Wall Vicinity SW of Bonita Isle Dr. & Al St. Lucie County, Florida GFA Project No. 13-2092.03 �Y • *„��� �..',���tuu,,? '' Hsu ,�' 'v ; � � 'tit ti i . 47 t,i+• i�'q, yes �9 J'YC ['� i. i r)S tiljf �h J 4��4� X5.•'t � �� . �. � it �' 1 3 �• `r :�r�iau�'���y��/ A� r' J :��.�✓. pit 4 i �. '. J- � v� �.�:'+r �� ,�.�Ut Googly;,�'�'``• �+ Tm�agei"^- 9U.3U528u �p � �ePl"109 t i F1orkla s Leacging Encru'neerir?Q Source I AUGER BORING LOGS WITH HAND CONE PENETROMETER (HCP) TESTS I Client: Tarpon Flats, LLC Project: Proposed Tarpon Flats Site Wall Vicinity SW of Bonita Isle Dr. & A1A St. Lucie County, Florida Elevation: Existing Grade Project No: Lab No: Test Date: Technician: 13-2092.03 10/13/2014 PM/W N TEST LOCATION: AB —1 N27.50534° W80.30530° HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0-2 Brown fine sand SP 1 60 2-5 Light brown fine sand SP 2 80+ 5-10 Brown fine sand, little shell SP 3 80+ 4 60 5 30 6 30 7 80+ 8 80+ 9 80+ 10 80+ Water table at 4% feet below ground surface TEST LOCATION: AB - 2 N27.50549° W80.30532° HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0 —1% Brown fine sand SP 1 50 1%Z — 3 Light brown fine sand SP 2 80+ 3-7 Brown fine sand, little shell SP 3 80+ 7-8 Gray fine sand, trace shell SP 4 1 80+ 8-10 Gray fine sand, some shell SP 5 80+ 6 80+ 7 60 8 80+ 9 80+ 10 80+ Water table at 4'/ feet below ground surface _Singe 1988r ' RNAT1o`_ rlo�i-idaa's Learlin fl Engineering Sc' w-ce AUGER BORING LOGS WITH HAND CONE PENETROMETER (HCP) TESTS Client: Tarpon Flats, LLC Project No: 13-2092.03 Project: Proposed Tarpon Flats Site Wall Lab No: Vicinity SW of Bonita Isle Dr. & A1A Test Date: 10/13/2014 St. Lucie County, Florida Elevation: Existing Grade Technician: PM/WN TEST LOCATION: AB — 3 N27.50526° W80.30527° HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0-2 Brown fine sand SP 1 80+ 2-7 Brown fine sand, little shell SP 2 80+ 7 —10 Gray fine sand, little shell SP 3 80+ 4 70 5 80+ 6 30 7 50 8 50 9 80+ 10 80+ Water table at 4% feet below ground surface