HomeMy WebLinkAboutHealth Dept Final �yFrt APPLICATION #:AP1453371 STATE OF FLORIDA PERMIT #:56-SF-2016731 DEPARTMENT OF HEALTH DOCUMENT #:FI 1560282 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:11/15/2019 FEE PAID:545.00 RECEIPT #:56-PID-4232591 APPLICANT: Port St. Lucie Properties, Inc AGENT: Alexander J. Piazza PSM, Inc PROPERTY ADDRESS: 6004 Hickory Dr Fort Pierce, FL 34982 LOT: 8 BLOCK: 70 SUBDIVISION: Indian River Estates ID#: 3402-609-0650-000-3 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED, TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] (02] TANK MATERIAL Polypropylene [ ] [281 DITCHES 15 FT [ ] [031 OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI-CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER PolylokPL-68 [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 07-053-10 2. [ ] [321 POTABLE WATER 36 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 5 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 509.4 [21 SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 6.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 01/05/2021 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 3.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [23] FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 09/04/2020 DISAPPROVED Environ ental Specialis n J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ] : St. Lucie CHD DATE: 01/05/2021 EnvifonmenLal Specialist rian J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP i 153371 EID2016731 APPLICATION #:AP1453371 STATE OF FLORIDA PERMIT #:56-SF-2016731 �' > DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11560282 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID.11/15/2019 con wb Y¢' FEE PAID:545.00 RECEIPT #:56-P I D-4232591 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of G persons(2 per bedroom),for a total estimated flow of 300 gpd. New ST,filter, and 3x7+3x8 long BED DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1453371 EID2016731