HomeMy WebLinkAboutEnergy Code2017 EPL DISPLAY CARD w ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 2835 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.274 14. Heating system: Capacity 34.0 c) Area 7c. 371.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 0.80 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 0.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d.. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which w' I be installed (or exc eded) in this home before final inspection. Otherwise, a new EPL display card will be cof leted based on inalled code compliant features. Builder Signature: i�-(/L'�-' `%�� Date: Address of New Home: 51 SOVEREIGHN WAY City/FL Zip: FORT PIERCE, FL 9/1/20201:22:25 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ROCK RESIDENCE Builder Name: HOMES BY ABURTON Street: 51 SOVEREIGHN WAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: THOMAS AND PRINCESS ROCK Jurisdiction: ST LUCIE COUNTY LLI Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be seated. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shalt include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to'exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind ploina and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilincis. a. In addition, inspection or log wars snarl De in accordance witn the provisions of IGG-400. 9/1120201:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2017 EPL DISPLAY CARD 2 011100lZ-1- ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2835 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.274 14. Heating system: Capacity 34.0 c) Area 7c. 371.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 0.80 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 0.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be com)leted based on in fed code compliant features. n, n Builder Signature: Date: Address of New Home: 51 SOVEREIGHN WAY City/FL Zip: FORT PIERCE, FL 9/1/2020 1:22:25 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ROCK RESIDENCE Builder Name: HOMES BY ABURTON Street: 51 SOVEREIGHN WAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: THOMAS AND PRINCESS ROCK Jurisdiction: ST LUCIE COUNTY W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps In the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind vioing and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Oates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/1/2020 1:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at hftp://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ROCK RESIDENCE Builder Name: HOMES BY ABURTON Street: 51 SOVEREIGHN WAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number. Owner: THOMAS AND PRINCESS ROCK Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2984.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead Aggret=0.0 2684.00 ft2 b. Frame - Wood, Adjacent R=11.0 300.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2835.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2835.00 ft2 6. Conditioned floor area above grade (ft2) 2835 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(371.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 200 a. U-Factor: Sgl, U=0.65 196.33 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 175.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 7.823 ft. Area Weighted Average SHGC: 0.274 14. Hot water systems a. Natural Gas Tankless Cap: 1 gallons 8. Floor Types (2835.0 sqft.) Insulation Area EF: 0.800 a. Slab -On -Grade Edge Insulation R=0.0 2835.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.131 Total Proposed Modified Loads: 95.25 PASS Total Baseline Loads: 96.02 I hereby certify that the plans and specifications covered by Review of the plans and �C'CKE STq?. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance:i„�,'� with the Florida Energy Code. , PREPARE Y: DATE. V - 2020 Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this buildi g, as designed, is in compliance Florida Statutes. Cab with the Florida Energy Co y�iE't�v OWNER/AG T: BUILDING OFFICIAL: DATE: % DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ROCK RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2835 Lot # Owner Name: THOMAS AND PRINCESS R Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMES BYABURTON Rotate Angle: 0 Street: 51 SOVEREIGHN WAY Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2835 30862 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 356 3916 No 0 1 1 Yes Yes Yes 2 M W IC 1 84 840 No 0 1 Yes Yes Yes 3 M WIC 2 36 360 No 0 1 No Yes Yes 4 M TOILET 28 280 No 0 1 Yes Yes Yes 5 M BATH 172 1720 No 0 1 Yes Yes Yes 6 FOYER 80 960 No 0 1 Yes Yes Yes 7 DINING RM 275 3300 No 0 1 Yes Yes Yes 8 FAMILY RM 304 3648 No 0 1 Yes Yes Yes 9 KITCHEN 268 3216 Yes 0 1 No Yes Yes 10 DINING CLST 18 180 No 0 1 Yes Yes Yes 11 PANTRY 48 480 No 0 1 No Yes Yes 12 BEDROOM 2 154 1540 No 0 1 1 Yes Yes Yes 13 UTILITY RM 123 1230 No 0 1 Yes Yes Yes 14 BATH 2 60 600 No 0 1 No Yes Yes 15 HALLWAY 106 1060 No 0 1 No Yes Yes 16 CLST 3 26 260 No 0 1 No Yes Yes 17 BEDROOM 3 260 2600 No 0 1 1 Yes Yes Yes 18 BATH 3 50 500 No 0 1 Yes Yes Yes 19 LINEN 8 80 No 0 1 No Yes Yes 20 CLST 4 10 100 No 0 1 Yes Yes Yes 21 NOOK 151 1812 No 0 1 Yes Yes Yes 22 BEDROOM 4 218 2180 No 0 1 1 Yes Yes Yes 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 44 ft 0 356 ft2 __-- 1 0 0 2 Slab -On -Grade Edge Insulation M W IC 1 12 ft 0 84 ft2 __-_ 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 2 1 ft 0 36 ft2 __-_ 1 0 0 4 Slab -On -Grade Edge Insulation M TOILET 4 ft 0 28 ft2 _--_ 1 0 0 5 Slab -On -Grade Edge Insulation M BATH 39 ft 0 172 ft2 -___ 1 0 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 0 80 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation DINING RM 24 ft 0 275 ft2 _-__ 1 0 0 8 Slab -On -Grade Edge Insulation FAMILY RM 16 ft 0 304 ft2 .... 1 0 0 9 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 268 ft2 _--. 1 0 0 10SIab-On-Grade Edge Insulation DINING CLST 2 ft 0 18 ft2 -.-_ 1 0 0 11SIab-On-Grade Edge Insulation PANTRY 1 ft 0 48 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 2 16 ft 0 154 ft2 _-__ 1 0 0 13SIab-On-Grade Edge Insulation UTILITY RM 13 ft 0 123 ft2 -.-_ 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 1 ft 0 60 ft2 --__ 1 0 0 15SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 106 ft2 -__- 1 0 0 16SIab-On-Grade Edge Insulation CLST 3 1 ft 0 26 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 3 7 ft 0 260 ft2 _-_- 1 0 0 18SIab-On-Grade Edge Insulation BATH 3 5 ft 0 50 ft2 --._ 1 0 0 19SIab-On-Grade Edge Insulation LINEN 1 ft 0 8 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation CLST 4 5 ft 0 10 ft2 -__- 1 0 0 21SIab-On-Grade Edge Insulation NOOK 22 ft 0 151 ft2 _--_ 1 0 0 22SIab-On-Grade Edge Insulation BEDROOM 4 33 ft 0 218 ft2 _-__ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area . Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 3171 ft2 0 ft2 Medium N 0.2 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2835 ft2 N N 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 356 ft2 0.1 Wood 2 Under Attic (Unvented) M WIC 1 0 Blown 84ft2 0.1 Wood 3 Under Attic (Unvented) M W IC 2 0 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) M TOILET 0 Blown 28 ft2 0.1 Wood 5 Under Attic (Unvented) M BATH 0 Blown 172 ft2 0.1 Wood 6 Under Attic (Unvented) FOYER 0 Blown 80 ft2 0.1 Wood 7 Under Attic (Unvented) DINING RM 0 Blown 275 ft2 0.1 Wood 8 Under Attic (Unvented) FAMILY RM 0 Blown 304 ft2 0.1 Wood 9 Under Attic (Unvented) KITCHEN 0 Blown 268 ft2 0.1 Wood 10 Under Attic (Unvented) DINING CLST 0 Blown 18 ft2 0.1 Wood 11 Under Attic (Unvented) PANTRY 0 Blown 48 ft2 0.1 Wood 12 Under Attic (Unvented) BEDROOM 2 0 Blown 154 ft2 0.1 Wood 13 Under Attic (Unvented) UTILITY RM 0 Blown 123 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood 15 Under Attic (Unvented) HALLWAY 0 Blown 106 ft2 0.1 Wood 16 Under Attic (Unvented) CLST 3 0 Blown 26 ft2 0.1 Wood 17 Under Attic (Unvented) BEDROOM 3 0 Blown 260 ft2 0.1 Wood 18 Under Attic (Unvented) BATH 3 0 Blown 50 ft2 0.1 Wood 19 Under Attic (Unvented) LINEN 0 Blown 8 ft2 0.1 Wood 20 Under Attic (Unvented) CLST 4 0 Blown 10 ft2 0A Wood 21 Under Attic (Unvented) NOOK 0 Blown 151 ft2 0.1 Wood 22 Under Attic (Unvented) BEDROOM 4 0 Blown 218 ft2 0.1 Wood WALLS Adjacent Space Cavity Width n Height Et Sheathing Framing Solar on Ahqnr1 Below SE Exterior Concrete Block - Polysty;TER BE 0 20 0 11 0 220.0 ft2 0 0 0.2 0 2 SW Exterior Concrete Block - PolystyTER BE 0 14 0 11 0 154.0 ft2 0 0 0.2 0 3 NW Exterior Concrete Block - PolystyTER BE 0 10 0 11 0 110.0 ft2 0 0 0.2 0 4 SE Exterior Concrete Block - PolystyrerM W IC 1 0 12 0 10 0 120.0 ft2 0 0 0.2 0 5 SE Exterior Concrete Block - PolystyrdWTOILET 0 4 0 10 0 40.0 ft2 0 0 0.2 0 6 NE Exterior Concrete Block - Polystyrerld BATH 0 14 0 10 0 140.0 f12 0 0 0.2 0 _ 7 SE Exterior Concrete Block - Polystyrerfd BATH 0 14 0 10 0 140.0 ft2 0 0 0.2 0 8 NW Exterior Concrete Block - Polystyrertd BATH 0 11 0 10 0 110.0 ft2 0 0 0.2 0 _ 9 NE Exterior Concrete Block - PolystyrenCOYER 0 8 0 12 0 96.0 ft2 0 0 0.2 0 10 NE Exterior Concrete Block - Polystyr€ WING RM 0 19 0 12 0 228.0 ft2 0 0 0.2 0 11 SE Exterior Concrete Block - PolystyrOlNING RM 0 5 0 12 0 60.0 ft2 0 0 0.2 0 _ 12 SW Exterior Concrete Block - Polystyr€AMILY RM 0 16 0 12 0 192.0 ft2 0 0 0.2 0 13 NE Exterior Concrete Block - PolystyVOWNG CLST 0 2 0 10 0 20.0 ft2 0 0 0.2 0 _ 14 NE Exterior Concrete Block - PolystyBEEDROOM 2 0 14 0 10 0 140.0 ft2 0 0 0.2 0 15 SE Exterior Concrete Block - PolystylE®ROOM 2 0 2 0 10. 0 20.0 ft2 0 0 0.2 0 16 NE Exterior Concrete Block - PolystyrUTdLITY RM 0 9 0 10 0 90.0 ft2 0 0 0.2 0 17 NW Exterior Concrete Block - Polystyrt#TdLITY RM 0 4 0 10 0 40.0 ft2 0 0 0.2 0 18 NW Garage Frame - Wood UTILITY RM 11 13 0 10 0 130.0 ft2 0 0.1 0.2 0 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 19 NW Garage Frame - Wood HALLWAY 11 4 0 10 0 40.0 ft' 0 0.1 0.2 0 _ 20 SW Exterior Concrete Block - PolystyBEmROOM 3 0 7 0 10 0 70.0 ftz 0 0 0.2 0 21 NW Garage Frame - Wood BEDROOM 3 11 13 0 10 0 130.0 ftz 0 0.1 0.2 0 22 NW Exterior Concrete Block - PolystyrenBATH 3 0 5 0 10 0 50.0 ftz 0 0 0.2 0 23 NW Exterior Concrete Block - PolystyrenBLST 4 0 5 0 10 0 50.0 ftz 0 0 0.2 0 24 SE Exterior Concrete Block - Polystyren(NOOK 0 10 0 12 0 120.0 ftz 0 0 0.2 0 25 SW Exterior Concrete Block - PolystyrenMOOK 0 12 0 12 0 144.0 ft' 0 0 0.2 0 26 SE Exterior Concrete Block - PolystylEIDROOM 4 0 7 0 10 0 70.0 ftz 0 0 0.2 0 27 SW Exterior Concrete Block - PolystyflffimROOM 4 0 17 0 10 0 170.0 ftz 0 0 0.2 0 _ 28 NW Exterior Concrete Block - PolystyMIDROOM 4 0 9 0 10 0 90.0 ftz 0 0 0.2 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated FOYER None .39 3 8 24 ftz 2 NW Insulated HALLWAY None .39 2 8 8 21.3 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Metal Low-E Single Yes 0.65 0.25 Y 10.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 2 SW 2 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ftz 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 3 SE 5 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ftz 1 ft 4 in 1 ft 4 in None None 4 NE 6 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 5 NE 9 Metal Low-E Single Yes 0.65 0.25 Y 5.3 ftz 13 ft 4 in 1 ft 4 in None None 6 NE 9 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ftz 13 ft 4 in 1 ft 4 in None None 7 NE 10 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 8 NE 10 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ftz 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 9 NE 10 Metal Low-E Single Yes 0.65 0.25 Y 18.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 10 NE 10 Metal Low-E Single Yes 0.65 0.25 Y 18.0 ftz 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 11 SE 11 Metal Low-E Single Yes 0.65 0.3 Y 10.0 ft' 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 12 SW 12 Metal Low-E Single Yes 0.65 0.3 Y 96.0 ft' 17 ft 4 in 1 ft 4 in Drapes/blinds None 13 NE 14 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 14 NE 16 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 15 SW 20 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 1 ft 4 in 1 ft 4 in None None 16 SE 24 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds None 17 SW 25 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft' 7 ft 4 in 1 ft 4 in Drapes/blinds None 18 SW 25 Metal Low-E Single Yes 0.65 0.3 Y 21.3 ftz 7 ft 4 in 1 ft 4 In Drapes/blinds None 19 SW 27 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ftz 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 630 ft2 630 ftz 21 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000484 3600.6 197.67 371.74 .1898 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 46.5 kBtulhr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # --- Supply --- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 , Attic 6 200 ft2 Attic 20 ft2 Default Leakage Attic (Default) c(Default) c 1 1 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Heatin Jan HFeb Feb Mar Mar A r A r Ma May Jun Jun Jul Jul Au Auge Se Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 'Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING CLST ' Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 LINEN Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 NOOK Default(8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 4 9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7