HomeMy WebLinkAboutEnergy Code2017 EPL DISPLAY CARD
w
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
46.5
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
2835
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.274
14. Heating system: Capacity
34.0
c) Area
7c.
371.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
0.80
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
0.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d..
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which w' I be installed (or exc eded) in this home before final inspection. Otherwise, a new EPL
display card will be cof leted based on inalled code compliant features.
Builder Signature: i�-(/L'�-' `%�� Date:
Address of New Home: 51 SOVEREIGHN WAY City/FL Zip: FORT PIERCE, FL
9/1/20201:22:25 PM
EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ROCK RESIDENCE Builder Name: HOMES BY ABURTON
Street: 51 SOVEREIGHN WAY Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: THOMAS AND PRINCESS ROCK Jurisdiction: ST LUCIE COUNTY
LLI
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA,
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be seated.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shalt include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous Insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to'exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind ploina and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilincis.
a. In addition, inspection or log wars snarl De in accordance witn the provisions of IGG-400.
9/1120201:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
2017 EPL DISPLAY CARD
2 011100lZ-1-
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
46.5
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2835
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.274
14. Heating system: Capacity
34.0
c) Area
7c.
371.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
0.80
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
0.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be com)leted based on in fed code compliant features.
n, n
Builder Signature: Date:
Address of New Home: 51 SOVEREIGHN WAY City/FL Zip: FORT PIERCE, FL
9/1/2020 1:22:25 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ROCK RESIDENCE Builder Name: HOMES BY ABURTON
Street: 51 SOVEREIGHN WAY Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: THOMAS AND PRINCESS ROCK Jurisdiction: ST LUCIE COUNTY
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA,
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps In the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind vioing and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Oates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/1/2020 1:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
This document was created with Win2PDF available at hftp://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ROCK RESIDENCE
Builder Name: HOMES BY ABURTON
Street: 51 SOVEREIGHN WAY
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number.
Owner: THOMAS AND PRINCESS ROCK
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2984.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead Aggret=0.0 2684.00 ft2
b. Frame - Wood, Adjacent
R=11.0 300.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (2835.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2835.00 ft2
6. Conditioned floor area above grade (ft2) 2835
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(371.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 200
a. U-Factor: Sgl, U=0.65 196.33 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 175.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
46.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 7.823 ft.
Area Weighted Average SHGC: 0.274
14. Hot water systems
a. Natural Gas Tankless
Cap: 1 gallons
8. Floor Types (2835.0 sqft.) Insulation Area
EF: 0.800
a. Slab -On -Grade Edge Insulation R=0.0 2835.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 95.25
PASS
Total Baseline Loads: 96.02
I hereby certify that the plans and specifications covered by
Review of the plans and
�C'CKE STq?.
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance:i„�,'�
with the Florida Energy Code.
,
PREPARE Y:
DATE. V - 2020
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this buildi g, as designed, is in compliance
Florida Statutes.
Cab
with the Florida Energy Co
y�iE't�v
OWNER/AG T:
BUILDING OFFICIAL:
DATE: %
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
ROCK RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2835
Lot #
Owner Name:
THOMAS AND PRINCESS
R
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
HOMES BYABURTON
Rotate Angle: 0
Street:
51 SOVEREIGHN
WAY
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County.
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2835
30862
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MASTER BEDROO
356
3916 No
0
1
1
Yes
Yes
Yes
2
M W IC 1
84
840 No
0
1
Yes
Yes
Yes
3
M WIC 2
36
360 No
0
1
No
Yes
Yes
4
M TOILET
28
280 No
0
1
Yes
Yes
Yes
5
M BATH
172
1720 No
0
1
Yes
Yes
Yes
6
FOYER
80
960 No
0
1
Yes
Yes
Yes
7
DINING RM
275
3300 No
0
1
Yes
Yes
Yes
8
FAMILY RM
304
3648 No
0
1
Yes
Yes
Yes
9
KITCHEN
268
3216 Yes
0
1
No
Yes
Yes
10
DINING CLST
18
180 No
0
1
Yes
Yes
Yes
11
PANTRY
48
480 No
0
1
No
Yes
Yes
12
BEDROOM 2
154
1540 No
0
1
1
Yes
Yes
Yes
13
UTILITY RM
123
1230 No
0
1
Yes
Yes
Yes
14
BATH 2
60
600 No
0
1
No
Yes
Yes
15
HALLWAY
106
1060 No
0
1
No
Yes
Yes
16
CLST 3
26
260 No
0
1
No
Yes
Yes
17
BEDROOM 3
260
2600 No
0
1
1
Yes
Yes
Yes
18
BATH 3
50
500 No
0
1
Yes
Yes
Yes
19
LINEN
8
80 No
0
1
No
Yes
Yes
20
CLST 4
10
100 No
0
1
Yes
Yes
Yes
21
NOOK
151
1812 No
0
1
Yes
Yes
Yes
22
BEDROOM 4
218
2180 No
0
1
1
Yes
Yes
Yes
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO 44 ft
0
356 ft2
__--
1
0
0
2 Slab -On -Grade Edge Insulation
M W IC 1
12 ft
0
84 ft2
__-_
1
0
0
3 Slab -On -Grade Edge Insulation
M W IC 2
1 ft
0
36 ft2
__-_
1
0
0
4 Slab -On -Grade Edge Insulation
M TOILET
4 ft
0
28 ft2
_--_
1
0
0
5 Slab -On -Grade Edge Insulation
M BATH
39 ft
0
172 ft2
-___
1
0
0
6 Slab -On -Grade Edge Insulation
FOYER
8 ft
0
80 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation
DINING RM
24 ft
0
275 ft2
_-__
1
0
0
8 Slab -On -Grade Edge Insulation
FAMILY RM
16 ft
0
304 ft2
....
1
0
0
9 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
268 ft2
_--.
1
0
0
10SIab-On-Grade Edge Insulation
DINING CLST
2 ft
0
18 ft2
-.-_
1
0
0
11SIab-On-Grade Edge Insulation
PANTRY
1 ft
0
48 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 2
16 ft
0
154 ft2
_-__
1
0
0
13SIab-On-Grade Edge Insulation
UTILITY RM
13 ft
0
123 ft2
-.-_
1
0
0
14SIab-On-Grade Edge Insulation
BATH 2
1 ft
0
60 ft2
--__
1
0
0
15SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
106 ft2
-__-
1
0
0
16SIab-On-Grade Edge Insulation
CLST 3
1 ft
0
26 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
BEDROOM 3
7 ft
0
260 ft2
_-_-
1
0
0
18SIab-On-Grade Edge Insulation
BATH 3
5 ft
0
50 ft2
--._
1
0
0
19SIab-On-Grade Edge Insulation
LINEN
1 ft
0
8 ft2
____
1
0
0
20SIab-On-Grade Edge Insulation
CLST 4
5 ft
0
10 ft2
-__-
1
0
0
21SIab-On-Grade Edge Insulation
NOOK
22 ft
0
151 ft2
_--_
1
0
0
22SIab-On-Grade Edge Insulation
BEDROOM 4
33 ft
0
218 ft2
_-__
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
v # Type Materials
Area .
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Flat tile/slate 3171 ft2
0 ft2 Medium
N
0.2 No 0.9
No
20
26.6
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2835 ft2
N N
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) MASTER BEDRO
0
Blown
356 ft2
0.1
Wood
2
Under Attic (Unvented) M WIC 1
0
Blown
84ft2
0.1
Wood
3
Under Attic (Unvented) M W IC 2
0
Blown
36 ft2
0.1
Wood
4
Under Attic (Unvented) M TOILET
0
Blown
28 ft2
0.1
Wood
5
Under Attic (Unvented) M BATH
0
Blown
172 ft2
0.1
Wood
6
Under Attic (Unvented) FOYER
0
Blown
80 ft2
0.1
Wood
7
Under Attic (Unvented) DINING RM
0
Blown
275 ft2
0.1
Wood
8
Under Attic (Unvented) FAMILY RM
0
Blown
304 ft2
0.1
Wood
9
Under Attic (Unvented) KITCHEN
0
Blown
268 ft2
0.1
Wood
10
Under Attic (Unvented) DINING CLST
0
Blown
18 ft2
0.1
Wood
11
Under Attic (Unvented) PANTRY
0
Blown
48 ft2
0.1
Wood
12
Under Attic (Unvented) BEDROOM 2
0
Blown
154 ft2
0.1
Wood
13
Under Attic (Unvented) UTILITY RM
0
Blown
123 ft2
0.1
Wood
14
Under Attic (Unvented) BATH 2
0
Blown
60 ft2
0.1
Wood
15
Under Attic (Unvented) HALLWAY
0
Blown
106 ft2
0.1
Wood
16
Under Attic (Unvented) CLST 3
0
Blown
26 ft2
0.1
Wood
17
Under Attic (Unvented) BEDROOM 3
0
Blown
260 ft2
0.1
Wood
18
Under Attic (Unvented) BATH 3
0
Blown
50 ft2
0.1
Wood
19
Under Attic (Unvented) LINEN
0
Blown
8 ft2
0.1
Wood
20
Under Attic (Unvented) CLST 4
0
Blown
10 ft2
0A
Wood
21
Under Attic (Unvented) NOOK
0
Blown
151 ft2
0.1
Wood
22
Under Attic (Unvented) BEDROOM 4
0
Blown
218 ft2
0.1
Wood
WALLS
Adjacent
Space
Cavity
Width
n
Height
Et
Sheathing Framing Solar
on Ahqnr1
Below
SE
Exterior Concrete Block - Polysty;TER BE
0
20
0 11
0
220.0 ft2
0
0
0.2
0
2
SW
Exterior Concrete Block - PolystyTER BE
0
14
0 11
0
154.0 ft2
0
0
0.2
0
3
NW
Exterior Concrete Block - PolystyTER BE
0
10
0 11
0
110.0 ft2
0
0
0.2
0
4
SE
Exterior Concrete Block - PolystyrerM W IC 1
0
12
0 10
0
120.0 ft2
0
0
0.2
0
5
SE
Exterior Concrete Block - PolystyrdWTOILET
0
4
0 10
0
40.0 ft2
0
0
0.2
0
6
NE
Exterior Concrete Block - Polystyrerld BATH
0
14
0 10
0
140.0 f12
0
0
0.2
0
_ 7
SE
Exterior Concrete Block - Polystyrerfd BATH
0
14
0 10
0
140.0 ft2
0
0
0.2
0
8
NW
Exterior Concrete Block - Polystyrertd BATH
0
11
0 10
0
110.0 ft2
0
0
0.2
0
_ 9
NE
Exterior Concrete Block - PolystyrenCOYER
0
8
0 12
0
96.0 ft2
0
0
0.2
0
10
NE
Exterior Concrete Block - Polystyr€ WING RM
0
19
0 12
0
228.0 ft2
0
0
0.2
0
11
SE
Exterior Concrete Block - PolystyrOlNING RM
0
5
0 12
0
60.0 ft2
0
0
0.2
0
_ 12
SW
Exterior Concrete Block - Polystyr€AMILY RM
0
16
0 12
0
192.0 ft2
0
0
0.2
0
13
NE
Exterior Concrete Block - PolystyVOWNG CLST
0
2
0 10
0
20.0 ft2
0
0
0.2
0
_ 14
NE
Exterior Concrete Block - PolystyBEEDROOM 2
0
14
0 10
0
140.0 ft2
0
0
0.2
0
15
SE
Exterior Concrete Block - PolystylE®ROOM 2
0
2
0 10.
0
20.0 ft2
0
0
0.2
0
16
NE
Exterior Concrete Block - PolystyrUTdLITY RM
0
9
0 10
0
90.0 ft2
0
0
0.2
0
17
NW
Exterior Concrete Block - Polystyrt#TdLITY RM
0
4
0 10
0
40.0 ft2
0
0
0.2
0
18
NW
Garage Frame - Wood UTILITY RM
11
13
0 10
0
130.0 ft2
0
0.1
0.2
0
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing Solar Below
_ 19
NW
Garage
Frame - Wood HALLWAY
11
4
0
10
0
40.0 ft'
0
0.1 0.2
0
_ 20
SW
Exterior
Concrete Block - PolystyBEmROOM 3
0
7
0
10
0
70.0 ftz
0
0 0.2
0
21
NW
Garage
Frame - Wood BEDROOM 3
11
13
0
10
0
130.0 ftz
0
0.1 0.2
0
22
NW
Exterior
Concrete Block - PolystyrenBATH 3
0
5
0
10
0
50.0 ftz
0
0 0.2
0
23
NW
Exterior
Concrete Block - PolystyrenBLST 4
0
5
0
10
0
50.0 ftz
0
0 0.2
0
24
SE
Exterior
Concrete Block - Polystyren(NOOK
0
10
0
12
0
120.0 ftz
0
0 0.2
0
25
SW
Exterior
Concrete Block - PolystyrenMOOK
0
12
0
12
0
144.0 ft'
0
0 0.2
0
26
SE
Exterior
Concrete Block - PolystylEIDROOM 4
0
7
0
10
0
70.0 ftz
0
0 0.2
0
27
SW
Exterior
Concrete Block - PolystyflffimROOM 4
0
17
0
10
0
170.0 ftz
0
0 0.2
0
_ 28
NW
Exterior
Concrete Block - PolystyMIDROOM 4
0
9
0
10
0
90.0 ftz
0
0 0.2
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NE
Insulated FOYER
None
.39
3
8
24 ftz
2
NW
Insulated HALLWAY
None
.39
2
8
8
21.3 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SE 1
Metal Low-E Single Yes
0.65
0.25
Y
10.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
SW 2
Metal Low-E Single Yes
0.65
0.3
Y
48.0 ftz
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
3
SE 5
Metal Low-E Single Yes
0.65
0.25
Y
6.0 ftz
1 ft 4 in
1 ft 4 in
None
None
4
NE 6
Metal Low-E Single Yes
0.65
0.25
Y
12.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
5
NE 9
Metal Low-E Single Yes
0.65
0.25
Y
5.3 ftz
13 ft 4 in
1 ft 4 in
None
None
6
NE 9
Metal Low-E Single Yes
0.65
0.25
Y
8.0 ftz
13 ft 4 in
1 ft 4 in
None
None
7
NE 10
Metal Low-E Single Yes
0.65
0.25
Y
6.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
NE 10
Metal Low-E Single Yes
0.65
0.25
Y
6.0 ftz
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
9
NE 10
Metal Low-E Single Yes
0.65
0.25
Y
18.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
10
NE 10
Metal Low-E Single Yes
0.65
0.25
Y
18.0 ftz
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
11
SE 11
Metal Low-E Single Yes
0.65
0.3
Y
10.0 ft'
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
12
SW 12
Metal Low-E Single Yes
0.65
0.3
Y
96.0 ft'
17 ft 4 in
1 ft 4 in
Drapes/blinds
None
13
NE 14
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
14
NE 16
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
15
SW 20
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft'
1 ft 4 in
1 ft 4 in
None
None
16
SE 24
Metal Low-E Single Yes
0.65
0.25
Y
16.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
None
17
SW 25
Metal Low-E Single Yes
0.65
0.25
Y
16.0 ft'
7 ft 4 in
1 ft 4 in
Drapes/blinds
None
18
SW 25
Metal Low-E Single Yes
0.65
0.3
Y
21.3 ftz
7 ft 4 in
1 ft 4 In
Drapes/blinds
None
19
SW 27
Metal Low-E Single Yes
0.65
0.25
Y
30.0 ftz
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
630 ft2
630 ftz
21 ft loft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000484
3600.6 197.67 371.74 .1898 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16 46.5 kBtulhr 1395 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Natural Gas Tankless
Exterior
0.8 1 gal 55.1 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
#
--- Supply ---
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 ,
Attic 6 200 ft2
Attic
20 ft2 Default Leakage Attic (Default) c(Default) c
1 1
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Coolin Jan
Heatin Jan HFeb
Feb
Mar
Mar
A r
A r
Ma
May
Jun
Jun
Jul
Jul
Au
Auge
Se
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
'Oft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING CLST
'
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
UTILITY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LINEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
NOOK
Default(8 Ibs/s .ft.
ft2
ft
0.3
BEDROOM 4
9/1/2020 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7