Loading...
HomeMy WebLinkAboutBuilding Plans06W EveD a .lino Department County m 5 - 851R0 = F RESN DROPS � MM M MIS 6FlF/ OiAgi IETJaI RStR51 RSIND2 g m ��yrtN m f7tf7inf& w0a EMINU NOTES L ST iNJC A N.� AGGE55GR. v Tla FEE FAtRYATED As FM NFPA-�fl,: FL--ROOO AN 65t1 X a 2 TYf_ TPNI 15 RAC*'.UHr FRf.M. A-35 GAR$GN STEED. ELATE Pip I5: U , u IsrR r 3 (LAB 1IIYFFS t 1LtII{�1�ALAP WiTTh A rL M �� M(WAVITY Or 110 A TO f75 SEE SEG 17 Of' NFPA-30: FGR PEFINITM A 25 AC��� 0" MljTTTF P„FF Ro qnr �.'t1.ATKiN AN? Will 5 pA-31J MGwA32.3 .Awl rY �IFG.ARY oNT-A1New A5 PER b T t rANE * ff �WPFP WITN VFNTM6 AS. PER NFPA V SF-6 425. I. 2 Wh VFW IS A i WIl PMF OFF ET' VENT x 2 6 MG1 ElvIEROMY VENT 15 A 6 IWH PRD5W AND VAa W RELIEF q IM-A. r1115 TANG 6 AN ATM.?'-,PfflG TAhK A5 PER IMA-V �541;2 TYE Wa>RKW PRE5%W GF THE TANG IS 10 Pq6 MEASLRED AT THE TOP 6F TtE TAW. 1 RE TANG 15 TE.5TED A5 PER NPR-V `•n-6TIGTI 4421. S A5 PER.WTA-V k335A Pf FLL ANC RETLRN LME5 WLL TEWINATc 6 wlaN GF Tt1E C r6m 6F Ttt ow t RETURN LINE 9 ALL RE51N FIPMED WU X 6RAPI! A 6AR" srE$ A5TM A53 / I2a Am N6TAIT.E.3 A5 PER FFPA V �EaM 51L 5Y6nm wLL.. CF... TSTP.D AS PER MiW-3a:!5E6 561, to AS PER. WF'A-3O 43121 eft- TO ilU 5"A(Wv MTWEEN TANGS NOT OV!R W FMF IN M&TER TNAT Is A HA2V MrAL r*K K 1/6 X au " of TtE AD,Ea Nr TANGS PWYETER XT NOT LCSs THAN 3 T ErT. 11. ALT ELEGT`Rl6A- xv WIN Raw RE RE5M STD TANG W5IRE ATVP PER W-6-la MR UX N A 6LA613 1, ✓PIVISON H, C*aP P W6ATIRJ: P, i%lva lax Ra ZZ I; i 0' 25' 4 100, 150, 200, — = Graphic Scale EXISTING OFFRUE BUILDING F.F. ELEV 21.DO' IRRIGATION WELL ELEV. 2255' pRAINFIELD ELEV 231 1430 SF N 89°30'00" E SWAL329.50North F//// m , 3 lS 12 U * v o m n, a EV I O I .. ASPHALT CD Z CONCRETE T = S.D3' 3'X3 CONC ... .. SLAB (ABC) T DESIGNED SBM DRAWN CRW CHECKED SBM SCALE ANOTED KMA MARK REVISION DATE BY DATE 06/16/2020 KMA Engineering & Surveying, LLC Consulting Engineers & Surveyors 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 DRAMFIELD LIFT STATION—, ELEV. EO 2. 0 I BE e 264.4 S 89' W 264.53 BFP 89°56'15" HE+-- OHE OHE OHE OHE OHE R 25.00 EDGE PVM T.. EDGE PVM'T T = 24.97" �:: T % L = 39.24'''.. S 89°30'00" W PVMT 23t WDe.... Maverick Boat Company 3054 Industrial 31st St. Fort Pierce, Florida RESIN TANK RECEIVED NOV 18 2020 Permitting Department -'St. Lucie Countv.. DA 7: DATE: PROJECT NO, 20 1081 SHEET Scott B. McGuire, P.E. David S. Knight, P.E. 1 of 1 Fl. Reg No. 39573 Fl. Reg No. 41060 SCOPE OF WORK I. THE 50OPE OF WORK IN THIS DOCUMENT 15 LIMITED TO THE PB16N AND CONSTRICTION OF A FOUNDATION 5LA13 AND CONTAINMENT WALL STRUCTURE TO SUPPORT A PRE-ENGINEERED PRE -MANUFACTURED STEEL RE-51N TANK PE516NED AND ROWN TOP FOR PRAINA6i MANUFACTURED BY NJR INDUSTRIES. 8' BOND BLOCK PRE-EN6R'D RE51N TANK 2. REFER TO ADMIN15TRATIVE 51TE PLAN FOR LOCATION OF EQUIPMENT TANK AND STRUCTURE_. W/ 1#5 CONT GROUTED STRUCTURAL NOTES SOLID S1 1. CONTRACTOR SHALL VERIFY ALL DIMEN510N5 IN THE FIELD AND NOTIFY THE ENSIREER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. PROVIDE 8"W GONT GONG CURB 2. ALL CONSTRUCTION SHALL BE BRAGED AND SHORED BY THE CONTRACTOR A5 REQUIRED TO SAFELY PERFORM THE WORK. 8" GMII WAIL W/ I #5 GONT ALONG SUMP b" STD PIPE BOLLARDS AT 6 FT Or, AS PER PLAN TANK SUPPORT AND ADJUSTABLE 01 0 0 0 10" WIDE x &' DP SUMP TRENCH STRUCTURAL SUBMITTALS LOAD CELL I. THE POLLOWIN6 MINIMUM STRUCTURAL SUBMITTALS SHALL BE SUBMITTED FOR REVIEW: ® A. CONCRETE MIX DE516N5 Tn o - - - - - - - - - - - - PROVIDE 1-1/2"O 6ALV PIPE B. REINFORGINI5 6' WG WATER STOP _ __...... _._ i F-2 DRAIN5 W/ GATE VALVES EA END G. MA50NRY AND MASONRY AGGE55ORIE5 6' PAT PERIMETER D. PRE -MANUFACTURED RE51N TANK SHOP PRANIN65 _ * I PRE-MAN1F RE51N TANK C -`1 ANGHORA6E BY TANK MAN1F. FOUNDATION 121 THICK GONG. SLAB 4 FT6 0 I j SI I. FOUNDATION5 ARE DE516NM BASED ON PRESUMPTIVE SAFE ALLOWABLE BEARING PRESSURE OF 2,500 P5F. AS - - - - 1 F-1- - - - J 2. CONTRACTOR SHALL VERIFY THAT THE MINIMUM COMPACTION OF 95% OF ITS MODIFIED PROCTOR ACCORDANCE WITH ❑ ❑ ❑ ❑ I ADJUSTABLE LOAD GELLS A5TM 0155115 OBTAINED PRIOR TO FOOTIN6 PLACEMENT. A - - - - - - CENTERED ON FOOTING 3. FOOTIN65 SHALL BE PLACED ON COMPACTED 501L FREE OF OROMIG DEBRIS. 31 4 PER TANK TYPICAL GRADE `r Q Q o � CONCRETE ,r, , �+ A 40" HIGH 8' GMU IN RINNIN6 BOND I. CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.G.I. 301 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS' /4 L i - - _ - F-I- - - - - ! J W/ #5 VERT BAR IN 6ROUfED CELLS LATEST EDITION AND A.G.1. 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL GONGREIE. Tit z %%: ❑ ❑ ❑ ❑ 0 32" O.G. MAX. 4 AS SHOWN WITH q 2. CONCRETE 5TREN5TH SHALL HAVE A MINIMUM 26 DAY GOMPRE551VE 5TREN&TH AS FOLLOWS: - - - - - - 6A HORIZ LADDER REINF AT I6' OG. FOUNDATIONS 3,000 P51 J' A66R. SLUMP 5" 3 I" W/G = 03 0 PROVIDE (1) COURSE 8" BOND MASONRY 6ROUT 3A00 P51 in A66R SLUMP 10"i I" WC, = WA FT6 AS PER PLAN BLOCK W/ I#5 o T/YIALL 3. REINFORGIN6 STEEL SHALL BE IN ACCORDANCE WITH A5TM A615 6RADE 60. 4. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH A5TM AI&5 AND SHALL BE ADEQUATELY SUPPORTED AT Y-0 O.G. EACH WAY. S 5. THE MINIMUM CONCRETE COVERA6E5 SHALL BE AS FOLLOWS: 3 GLR TYP F-I (TYP ® 3 51DE5) CAST A6AIN5T EARTH 3 INS L - - - - - - - - J 2" THICK GONG SLAB W/ #6 2-0" � e - - - - - ® AT 12" OG EA WAY TOP 4 BOT EXPOSED TO WEATHER I I/2 INS T/5LAB LEVEL 6. PROVIDE q0 DEGREE LAP SPLICES .4T ALL INTERSECTIONS. 1. REINFORCIN6 SHALL BE LAPPED 5PLICED AND TIED WITH THE FOLLOWIN6 MINIMUM: A RESIN TANK WALL SECTION 8" 25'-8' 8' #4 INS 30 SCALE: 3/4' = 1'-0' #5 30 INS #b 361N5 21'-0' 5'-0" BUILDING STRUCTURE 8. CONCRETE SHALL BE TESTED IN ACCORDANCE WITH A5TM 0q. A MINIMUM OF (5) TEST CYLINDERS 5HALL BE TAKEN FOR MIN EACH 100 CU YD5 OF POUR, WITH ADDITIONAL SETS FOR EVERY 50 CU Y05 OF POUR. CYLINDERS SHALL BE TESTED AS FOLLOWS: I o 3 DAYS ® l DAYS 2 0 28 DAYS I ® 56 DAYS (IF THE MINIMUM 5TREN6TH 15 NOT MET IN 2& DAYS) q. CONTRACTOR SHALL PROVIDE SAW GUTS IN SLABS AT A MAXIMUM SPACING AS INDICATED IN PLAN AND AT ALL RE-ENTRANT CORNERS. SAW CUT5 SHALL BE 1/4 THE SLAB DEPTH AND SHALL BE PERFORMED AS 50ON AS THE CONCRETE HAS HARDENED 5UFFIGIENTLY TO PREVENT THE A66RE6ATE FROM BEIN6 015LOPOW BY THE SAW BLADE. THI5 15 AN EFFORT TO CONTROL THE A 5HRINKA6E STRESSES AN INHERENT PROPERTY OF CONCRETE WHICH SOMETIMES RESULTS IN CRACKS, WHICH 15 NOT UNCOMMON. 8' GMU WALL RESIN TANK CONTAINMENT WALL & SLAB PLAN MASONRY AS PER PLAN I. CONCRETE MASONRY WORK SHALL BE IN ACCORDANCE WITH AGI 530.1/A5GE 6/TM5 602, SPEGIFIGATfON FOR CONCRETE SCALE: I/8" = I'-0' MASONRY STRUCTURES AND AGI 530/A56E 5/TM5 402, BUILDING CODE REQUIREMENTS FOR MA50NRY STRICTURES. NOTES: 2. CONCRETE MA50NRY UNITS SHALL BE IN CONFORMANCE WITH A5TM GqO, GRADE N, TYPE 11. MASONRY UNITS 5HALL BE TESTED 8' " I. PRE -MANUFACTURED 5,&&0 6AL RE51N TANK BY N.J.R. 51ZE 8'-b"H x Il'-q'L x 8'-3"W IN ACCORDANCE WITH ASTM G140 AND SHALL HAVE A MINIMUM FM = MOO P51. 6" PVC WATER STOP IO 10' W x b" DP SUMP TRENCH 2. RE51N TANK PE16HT = 13, 000 L135 (63 TONS) 3. GROUT SHALL BE IN CONFORMANCE WITH ASTM C416, COARSE TYPE SLUMP q' TO 11'. NU 1-1/2" 6ALV PIPE DRAINS AT EN05 RE51N WEIGHT = b5, 000 L135 4. MORTAR SHALL BE IN ACCORDANCE WITH A5TM G770, TYPE 5. TOTAL = 18, 000 LB5 5. ALL MA50NRY JOINTS 5HALL BE WATERTI6HT AND CONCAVE TOOLED WITH A NON 5TAININ6 TOOL. 12' THICK CONIC. 5LA13 4 FTC 6. EXTERIOR SURFACES SHALL SEALED AND PAINTED. I #5 GONT IN GONG CURB AS PLAN _ 3. F-1: 24" DEEP x 24' WIDE x CONT. W/ 3 ## LW BOT. 1. PROVIDE GLEANOUT5 AT INTERIOR 51RFACE5 FOR ALL 6ROUTED GONSTRUCTION AND LIMIT MORTAR PROTR1510N5 TO 1/2' MAXIMUM F-2: 24' DEEP x 30" WIDE x GOMT. W/ 3 #6 LW BOT 4. REFER TO 51TE PLAN FOR ACTUAL LOCATION IN 6ROUTED CELLS. &. ALL MASONRY WALLS SHALL BE CONSTRUCTED IN RUNNIN6 BOND WITH q 6A. LADDER TYPE JOINT REINFORGIN6 SPADED • 16' O.G. VERTICALLY. LAP AT ALL CORNERS AND &" MINIMUM. q. PROVIDE 8" PRECAST CONCRETE LINTELS WITH 1 #5 HORIZONTAL BAR 6ROUTED SOLID AT ALL MASONRY OPENIN65 WITH A MINIMUM OF \' ` 8" BEARING EACH END, TYPICAL UNLESS NOTED OTHERWISE. STORAGE TANK /CONTAINMENT STRUCTURE CLASSIFICATION i� , • FT6 AS PER PLAN CLASS 1A FLAMMABLE LIQUID STORED A7 ATMOSPHERIC PRESS. FIRE SEPARATION REQUIREMENTS 3 GLR TYP BUILDING CLASSIFICATION F-1 SPRINKLERED 21-b' STORAGE TANK H-3 FBC TABLE 508.4 NO SEPARATION REQUIRED NFPA30 TABLE22.4. 1.1 (b) 30 FT FROM PROPERTY LINE & 5FT FROM BUILDING B RESIN TANK WALL AT SUMP SEPARATION PROVIDED > 30 FT TO PROPERTY LINE SCALE: 3/4' = I'-0' > T-6 TO STORAGE TANK & 5 FT TO CONTAINMENT STRUCTURE PRE-EN6R'D RE5114 TANK TANK SUPPORT AND ADJUSTABLE LOAD CELL CENTERED ON FT6 Q Tv 6 AS PER PLAN ' 2'-0' C RESIN TANK FTG SECTION 5GAL,Et 3/4' = 1'-0" RECEIVED NOY ) 8 2020 ..Permitting Departmen` St. Lucie Count, I ' I I Z t 0) 10 OW'. C 64 "44, § j Wh W 7 '~ LL � I N M UO ' ju Z OM a)Pp"I ° LL C = p N On O Le NLj r I > O ca E U 5 . This drawing and design as shown is the property of ML Engineering, Inc. Reproduction and/or use of this drawing or any content therein, without express consent or permission of this company Is prohibited, may constitute an Infringe- ment, and may be subject to legal action Ii ML Engln®®ring, Ino. 0 O LL U) W Z O U W_ //Q,, V H L W � O W U) Z 66 O O O W QW U ~ W Z C QO -C Z N Z� LUUQ m LLI W Ivoo 0< z a. Z Q 02 Z W Q Q I- M Joe m �z Lij ISSUE: DATE: 1. CLIENT REVIEW 08/18/20 2. PERMIT 09/01/20 REVISIONS: DATE: DATE: 08/1 $/2 DRAWN BY: TR CHECKED BY: ML JOB No. 20-1 98 SEAL: ILI Ut MICHAEL A. LUE, P.E. FLORIDA REG. #47520 SHEET NO: siiiiiiiii OF 1 SHEET