Loading...
HomeMy WebLinkAboutProduct Approval (2)12/15/2020 Florida Building Code Online BCIS Home I Log In I User Registration � Hot Topics j Submit Surcharge i Stats & Facts Publications Contact Us BCIS Site Map i Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By FL601-1113 Affirmation 2017 Approved QA expired for sub products 1, 3,4,5,6,8,9,10, 12, and 14. Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (801)380-6091 RobinAnderson@boral.com Thomas Jemmett thomas.jemmett@boral.com Adrian Cooper 135 NW 20th Street Boca Raton, FL 33431 (954)520-5461 acoopeer@minierlifetile.com Thomas B. Jemmett 7575 Irvine Center Drive Irvine, CA 92618 (602)515-6933 BoralRoofingUSAQuality@boral.com Roofing Roofing Tiles Certification Mark or Listing Miami -Dade BCCO - CER Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) Standard TAS 101 TAS 102 TAS 102 (A) TAS 112 Equivalence of Product Standards Certified By hftps://www.floridabui Id i ng.org/pr/pr_app_dti.aspx? param=wG EVXQwtDgsW 8sQOzUoOU7%2fVx8e2uOu kC47u EvVpCkM %3d Year 1995 1995 1995 1995 1/5 12/15/2020 Florida Building Code Online I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A Product Approval Method Method 1 Option A Date Submitted 10/03/2017 Date Validated 10/03/2017 Date Pending FBC Approval Date Approved 10/08/2017 Summary of Products FL # Model, Number or Name I Description 1601.1 Atlantis - Shake & Slate Flat Profile - Pompano Beach Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090409.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/16/2017 Design Pressure: N/A i Installation Instructions Other: FL601 R13 II 12090409.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.2 Barcelona 900 High Profile - Lake Wales Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 16-0711.01.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/26/2022 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 16-0711.01.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.3 Capri Low Profile - Lake Wales Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090407 Capri.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/16/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090407 Capri.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.4 Cedarlite 600 Flat Profile - Stockton Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 15060106 Cedarlite 600.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/16/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 15060106 Cedarlite 600.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.5 Espana High Profile - Lake Wales Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090405 Espana.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date hftps://www.floridabui lding.org/pr/pr_app_dtl.aspx?param=wG EVXQwtDgsW8sQOzUoOU7%2fVx8e2uOu kC47u EvVpCkM%3d 2/5 12/15/2020 Florida Building Code Online Impact Resistant: N/A 12/16/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090405 Espana.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.6 Madera 700 Flat Profile - Stockton Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 15060105 Madera 700.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/06/2017 Design Pressure: N/A I Installation Instructions Other: i FL601 R13 II 15060105 Madera 700.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.7 Madera 900 Flat Profile - Stockton Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 15060107.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/15/2019 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 15060107.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.8 Saxony -Shake, Slate, Split Shake Flat Profile - Lake Wales Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090412 Saxony_pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/16/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090412 Saxony_pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.9 Saxony 600 - Shake, Slate & Split Flat Profile - Stockton Shake Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090404 Saxony600.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/06/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090404 Saxony600.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.10 Saxony 700 - Shake, Slate & Split Flat Profile - Stockton Shake Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090403 Saxony 700.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/06/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090403 Saxony700.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.11/ 0 ,\ Saxony 900 - Shake, Slate, Split Flat Profile - Lake Wales Shake Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes i FL601 R13 C CAC NOA 16-0711.05.pdf hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsW8sQOzUoOU7%2fVx8e2uOukC47uEvVpCkM%3d 3/5 12/15/2020 Florida Building Code Online Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/26/2022 Design Pressure: N/A Installation Instructions Other: FL601 R13 II NOA 16-0711.05.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.12 Spanish "S.' High Profile - Pompano Beach Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090408 Spanish S.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 01/02/2018 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090408 Spanish S.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.13 Spanish "S" Nuevo High Profile - Lake Wales Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC NOA 14-0408.06.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 05/20/2019 Design Pressure: N/A Installation Instructions Other: FL601 R13 II NOA 14-0408.06.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.14 Vanguard Roll Low Profile - Pompano Beach Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC 12090406 Vanguard Roll.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 12/16/2017 Design Pressure: N/A Installation Instructions Other: FL601 R13 II 12090406 Vanguard Roll.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 601.15 Villa 900 Low Profile - Lake Wales -------------- Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL601 R13 C CAC NOA 16-0711.04.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/21/2021 Design Pressure: N/A Installation Instructions Other: FL601 R13 II NOA 16-0711.04.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back k Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® eC neck https://www.floddabui Id ing.org/prlpr_app_dti.aspx? param=wG EVXQwtDgsW8sQOzUoO U7%2fVx8e2uOu kC47u EvV pCkM %3d 4/5 ka ., C44hTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.2ov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.13-0723.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Categorv: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Saxony 900-Slate Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-5/32" batten, mortar set or adhesive set applications. Saxony 900 Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Split Shake Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush Saxony 900-Shake Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete roof Width: varies pieces for use at hips, ridges and rakes. varying thickness NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 2 of 8 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL 2.2 EVIDENCE SUBMITTED: Test A2ency Test Identifier Test Name/Report Date The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94-060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 25-7183-6 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik-Drive Screws, Direct Deck) The Center for Applied 25-7183-5 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik-Drive Screws, Battens) The Center for Applied 25-7214-1 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik-Drive Screw, Direct Deck) The Center for Applied 25-7214-5 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik-Drive Screw, Battens) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-77 TAS 100 Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II & III TAS 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Atlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 Engineering, Inc. TAS 112 Celotex Corporation 520109-1 Static Uplift Testing Dec. 1998 Testing Service 520111-4 TAS 101 Celotex Corporation 520191-1 Static Uplift Testing March 1999 Testing Service TAS 101 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 25-7848-6 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 American Test Lab of RT0617.04-16 TAS 112 06/29/16 South Florida NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 3 of 8 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall. be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Saxony 900 Slate, Shake & Split Shake 10.9 1.417 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile )L (ft3) X (ft3) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Saxony 900 Slate, Shake & Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Split Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 APPROVED NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 4 of 8 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19132" plywood) Battens Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake Adhesive' 31.32 & 3 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBondTM one -component foam minimum weight per paddy 13.9 grams. 3 ICP Adhesives Polyset0 RTA-1, one -component foam, minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake ICP Adhesives PolysetO AH-160 Two -component foam 118.94 40.45 4 Large paddy placement of 45 grams of Polysete AH-160. 5 Medium paddy placement of 24 grams of Polyset0 AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake Mortar Seth 43.96 6 Tile -rite Roof Tile Mortar NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 5 of 8 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NAIL HOLES r PROFILE DRAWINGS UNDERLOCK I SAXONY 900 - SLATE 5/32" (Slate) COVERLOCK NOA No.: 16-0711.05 CMIAMIMADE=COUNTY Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 6 of 8 NAIL HOLES PROFILE DRAWINGS cm \� `� "'►..= ,� 1-9/32" (Shake) Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 7 of 8 NAIL, HOLES u PROFILE DRAWINGS SAXONY 900- SHAKE END OF THIS ACCEPTANCE 1-9/32" (Shake) 7 NOA No.: 16-0711.05 MIAMI•DADE COUNTY Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 8 of 8