Loading...
HomeMy WebLinkAboutScan_2021-01-07-164033590M IAM i•QADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamiaade.goy/economy Maxim Industries, Inc. 1630 Terre Colony Court Dallas, TX 75212 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Model MAX DGCM 2017 Curb Mount Aluminum Skylight APPROVAL DOCUMENT: Drawing No. MAX DGCM 2017, titled "Maxim Impact Glass Curb Mount Skylight", prepared by Maxim Industries, Inc, sheets I and 2 of 2, dated 05/01/2017, signed and sealed by Robert James Amoruso, P.E., on 11/08/17, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number & approval date by the Miami -Dade County Product Control Section. MISSILE LYYPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA nurnber preceded by the words Miarni-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 15-0728.06 and consists of this page 1 and evidence pages E-I & E-2 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. K0`M+ " W hk� NOA No.17-1212.04 ° � � U Expiration Date: 02/15/2023 am; s C 2 �; % Approval Date: 02/1.5/2018 / Page 1 Maxim Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. MAX DGCM 07, titled "Maxim Impact Glass Curb Mount Skylight", prepared by Maxim Industries, Inc, sheets 1 and 2 of 2, dated 12/12/2012, signed and sealed by Richard Boyette, P.E. B. TESTS "Submitted under NOA # 07-1105.05" 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC; TAS 203-94 along with marked -up drawings and installation of the Maxim Impact Glass Curb Mount Skylight, prepared by Hurricane Test Laboratory LLC, Test Report No. T482- 0604-07, dated 10/09/2007, signed and sealed by Vinu J. Abraham, P.E. C. CALCULATIONS "Submitted under NOA # 07-I105.05" I. Anchor calculations dated 10/28/2007, prepared, signed and sealed by Richard Boyette, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of acceptance No. 11-0624.02 issued to E.I. DuPont De Nemours & Co., Inc, for their SentryGlas Interlayer, approved on 05/10/2012 and expiring on 12/11/2016. F. STATEMENTS 1. Statement letter of code conformance to the 5th edition (2015) FBC issued by Richard Boyette Consulting Inc., dated 07/12/2015, signed and sealed by Richard Boyette, P.E. 2. Statement letter of no financial interest issued by Richard Boyette Consulting Inc., dated 07/12/2015, signed and sealed by Richard Boyette, P.E. "Submitted under NOA # I2-I022.02" 3. ' Statement letter of code conformance to 2010 FBC issued by Richard Boyette, dated 12/2.3/2012, signed and sealed by Richard Boyette, P.E. 4. No financial interest letter issued by Richard Boyette, dated 09/11/2012, signed and sealed by Richard Boyette, P.E. OelmyA. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-1212.04 Expiration Date: 02/15/2023 Approval Date: 02/15/2018 E -1 Maxim Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. MAX DGCM 2017, titled "Maxim Impact Glass Curb Mount Skylight", prepared by Maxim Industries, Inc, sheets I and 2 of 2, dated 0510112017, signed and sealed by Robert James Amoruso, P.E., on 11108117. B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform- Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Testper FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation of the Maxim Impact Glass Curb Mount Skylight, prepared by Intertek/Architectural Testing, Test Report No. H0993.01-801-18, dated 0510412017, signed and sealed by Tyler Westerling, P.E. C. CALCULATIONS "Submitted underNOA # 071105.05" 1. Anchor calculations dated 1110812017, prepared, signed and sealed by Robert James Amoruso, P.E., on 11108117. D. QUALITY ASSURANCE 1. By Aflami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 6`' edition (2017) FBC issued by Robert James Amoruso, P.E., on 11108117, signed and sealed by R Robert James Amoruso, P.E. C41ilmy A. Mahar, P.E., M.S. Product Control Section Supervisor NOA No. 17-1212.04 Expiration Date: 02/15/2023 Approval Date: 02/15/2018 E 4.. 0 = o0 0 CL J r_ O O cn N O 0 _ N T� to N o pcl O N � O r N ^ '6 4C U4 O j W N N df O •�^ �O (n � O N c ` '° ,o V- c3 i " U O —off @� o �? U FD _ LL _ +9.' O L >Y a d O 0 E N o v O o o z II u ¢ z Z m w V 3 a ¢ w All, E C7 r o 0 of of N N � LL- r uj Z X N o v f~A= Wo A. z99 of 0 La u � aD Q B o 5 E O N 9 N u c� fir° a vm .o E� £ ~ ym m•cR_ �" � c E 2 a � a s — T3 -?� d di � o @ o � •� f2 7 c gp 'dj •0 12 m c c g •o '_' rr ga F•� Ew 1° * �mU . RX f Q Q QW(.a6 ,F tea � 6 N fop o1k� Yn'mX�X$m� 'cyst E='�.c..t �cocy��� � N �e��QQJ'••�••'��/°��i VI II OEM p.X �.ci CN "�Y jOm ��'a ��iz � Q•�yeV� �LL L rn= �X—yam¢^o22 g' lac :E -c %Evcry W Wt LtJ CLa w tC 0.7 V c n C �'�c� N yJ =1 ? .y • s�� /-1 0m '%(S� gai �ap�m �n c c—@cam o E E • 'ui �®Bow I° f/ .pf PR rya °°°Pr8®4aacauaee LL.. v E _ E$ •' v1 C z 2 IyI q _ E 'O c3 p�� lh I+j 00 �14 m# * N Ln °)''x 'x t v N F- iri 3k Vl N a y f0 f0 I VI �. = p 0 �Oak � o y m a fu m g a m Q iJ it N Y N Z w Z 1 ru o o co m fri fri u�L.. o� cn IV m E E j E E G S U O o0 U � o N fo fa a) x rn a`i fll fL 0 0 C U a a c c c fco Fes- �° g afOi g O o 0O o��� E z N -0 Z m Z N C E E O O 7 M W Q Q Q W � = E (� m i F- U = E i= o o N cn c a) v fiCA C7`a� m v aci v E Em a' O C N N N. 20 a) 45 H O EE8`6Wx- o I- \ tom.) '~ E rn v v m v a 3 c.0 M w n -i2- 'O'O.6 xeW w 3 � a) fca •.a • m E W A N L2 E � o m F7 fn o� fn >> ri E W o rn �awOa ea w� 45£ ° I I- v m c" `TO X E Z J a4. N '� a�Gn 3 �cO v — v �5 50 n�4=YXt E �Y• Uoo i ■v.� I ° p �_ �... V /Li Q m o N O an O cn c c c o N m O Ln V / _ f6 ~ 4 v ��.....� .o X N�-f O O O y N rocO R EQ .� c u 3 m aih,ary ;fz \ B C$ @ I I \ n pp- N �n \ n N i Ul U •O 'G u1 c w 0 VU./j a, o p 3 °a •o E E n O L.L E u rn fO Et'o� 5c EE u m O T fs Q,. N LL O W \ u- c p jf \ O dS C ofO. aZ c"m�cmi�b�,��,rn�QF�v���`•��©E ZEodrn— y ,,SL'6S=6uivadOld oc o f uE mePO�`,� � al - L y L @ O Z 7= vi O ,^C1 0 �A i E 0 V/ o LU fn + fn � « N '0 to Q I L .0 ri -- C T •- 0 I .,S'i9 = y;6ua� � F- � P w ¢ ¢ � rL 3 v awea.1 0 ti N r; 4 fri LIGHT TRANSMISSION & GLAZING PERFORMANCE Sheffield Makrolon® Polycarbonate Dome Clear/Bronze (CB) 25% 60% .90 .97 0.7 (ASHRAE) Clear/Clear (CC) 74% 89% .90 .97 1.02 (ASHRAE) Clear/Gray (CG) 43% 60% 90 .97 0.7 (ASHRAE) Bronze/Bronze (BB) 07% 36% 90 .97 0.49 (ASHRAE) Clear/White (CV/) 23% 40% .90 .97 0.71 (ASHRAE) insulated Glass Performance ILoE366 (Low E Cubed)/Argon Gas: 0.27 0.24 0.43 66% Bronze Tint/ Argon Gas: 0.63 0.31 0.52 61 % Gray Tint/ Argon Gas: 0.63 0.31 0.52 61 % FRAME FINISHES Mill Finish White Powdercoat Bronze Anodized Custom Color Powdercoat All insulated ;lass provided by Alaxim JlCil!!�t'• ,?Igon gas. -i%I laminated impact resistant glass is manufactured wit) DuPont—SentrK;las 111us. Custom Color Powdercoat FEATURES • Approvals include multiple Miami -Dade County Product Control NOAs; Florida Building Commission, FBC 2418-R3 (2010); Texas Department of Insurance, TDI Report(s) SK-13 & SK-18 • All Maxim Skylights are tested and conform to AAMA/WDMA/CSA 101/I.S.2/A440-05 and all, or part, of the following standards: ASTM E283, ASTM E330, ASTM E331, ASTM E547, ASTM El886, Missile Level C as specified in ASTM E1996-99, TAS 201-94, TAS 202-94, TAS 203-94, and ASTM E1300-02/03. • All Maxim Skylights are third party certified to performance compliance and quality assurance by the National Accreditation Management Institute (NAM1). • Available in any size or shape up to 25 square feet, the largest impact resistant insulated glass skylight available. e Insulated Glass for maximum energy efficiency available as Tempered, Laminated and DuPont" SentryGlas° Plus Impact resistant. Unlimited configurations to meet any conditions. Optional curb assembly w/ prefinished white interior, solid wood curb and aluminum counterflashing. • Insulated glass is tested to-200psf negative pressure for a +/-100psf Design Pressure. • All Maxim insulated glass comes with XL Edge' technology providing the lowest failure rate in the industry. Developed in part from our suppliers 45 years of experience in manufacturing dual -seal silicone insulated glass. • Mill Finish, Bronze Anodized, Clear Anodized or an unlimited number of powdercoat colors are also available. • All insulated glass is covered by the manufacturer for 20 years • Curb Mount available up to 36 square feet & Self Flashing up to 32 square feet in any size or shape. • Polycarbonate domes are tested to-120psf & +180psf for a +/-60psf Design Pressure. Sheffield Plastics Makrolon SL UV enhanced polycarbonate outer domes for the ultimate in ultraviolet light protection. Virtually unbreakable polycarbonate domes meet large & small missile impact rating. • Sealed double domes prevent moisture from occurring between the domes. • Polycarbonate glazing meets UL 972 forced entry protection. • Stainless steel fasteners eliminate rust and corrosion. "Any type of cleaning performed on the roof, including removal of mold, mildew, fungus, or dirt, by pressure of any kind with water or chemical means will damage polycarbonate domes and void any warranty. A detailed insulated glass warranty is available upon request. WARNING: SKYLIGHTS MAY NOT SUPPORT LIVE LOADS! While these skylights have passed testing for large and small missile impact resistance, 1000 fc/lbs fall protection resistance and up to 200psf. positive pressure testing, they are not intended for any live load! Do not stand, sit, lean, or rest on any pan of the skylight. Corporate Florida 1630 Terre Colony Court • Dallas, Texas 75212.6221 1818 7'h Avenue North, Suite 2 • Lake Worth, Florida 33461 Toll Free 888-222-4898 • Fax 214-905-2024 Toll Free 800-367-8168 • Fax 561-588-9283