Loading...
HomeMy WebLinkAboutcoolcalc-mj8-report-1Project Name: Adrienne Recco Addition Address: 127 Northeast Estia Lane, Port St. Lucie, FL Summer Outdoor F:90 Summer Indoor F:75 Design Grains:61 Daily Range:Medium Winter Outdoor F:42 Winter Indoor F:70 Cooling RH:50 Elevation (Ft):25 Heated square footage:722 Cooled square footage:722 Heated volume (above grade CF):5,870 Cooled volume (above grade CF):5,870 Exposed wall area (SF):694 Heating BTUH:13,715 Cooling BTUH:11,954 CFM:394 Sensible cooling:9,556 Latent cooling:2,398 SHR:0.799 Approved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. OUTDOOR DESIGN CONDITIONS Weather station: Fort Pierce LOAD CALCULATION TOTALS HVAC System: Mini split system Load Calculation 0 5,000 10,000 15,000 Cooling Heating BTUH HEATING LOADS SECTION AREA HEAT LOSS aboveGradeWalls 598 5,710 ceilings 722 890 floors 722 2,940 infiltration 0 1,837 skylights 0 0 windows 96 2,339 Totals 13,715 COOLING LOADS SECTION AREA SENSIBLE LATENT AEDExcursion 0 0 0 aboveGradeWalls 598 3,548 0 appliances 0 1,200 0 ceilings 722 953 0 floors 722 0 0 infiltration 0 516 1,298 occupants 0 920 800 plants 0 0 300 skylights 0 0 0 windows 96 2,419 0 Totals 9,556 2,398 HEATING AND COOLING LOADS Heating Loads aboveGradeWalls 41.6% ceilings 6.5% floors 21.4% infiltration 13.4% windows 17.1% Cooling Loads aboveGradeWalls 29.7% appliances 10% ceilings 8% infiltration 15.2% occupants 14.4% plants 2.5% windows 20.2% This graph represents hourly aggregrate fenestration loads in mid-summer. This graph represents hourly aggregrate fenestration loads in October. FENESTRATION LOADS Warning (0): The sensible load for this application peaks during late fall or early winter. This behavior is caused by glass that faces SouthEast, South or SouthWest. Some rooms may be noticeably cooler or warmer than the temperature set point if zoning is not provided. Simultaneous heating and cooling may be required. AED Graph (mid-summer) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 2,000 4,000 BTUHAED graph (fall) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 2,000 4,000 6,000 BTUH Construction nr:14F-0 U Value:0.341 Exposure:S Area:71 Heating BTUH:678 Cooling BTUH:421 Construction nr:14F-0 U Value:0.341 Exposure:E Area:84 Heating BTUH:802 Cooling BTUH:498 Construction nr:14F-0 U Value:0.341 Exposure:S Area:252 Heating BTUH:2,406 Cooling BTUH:1,495 Construction nr:14F-0 U Value:0.341 Exposure:S Area:42 Heating BTUH:401 Cooling BTUH:249 Construction nr:14F-0 U Value:0.341 Exposure:W Area:78 Heating BTUH:745 Cooling BTUH:463 Construction nr:14F-0 U Value:0.341 Exposure:S Area:71 Heating BTUH:678 Cooling BTUH:421 Construction nr:4C Area:6 Exposure:S U Value:0.87 SHGC:0.67 Heating BTUH:146 Cooling BTUH:104 Construction nr:4C Area:12 Exposure:E U Value:0.87 SHGC:0.67 Heating BTUH:292 Cooling BTUH:450 Construction nr:4C Area:12 Exposure:E U Value:0.87 SHGC:0.67 Heating BTUH:292 Cooling BTUH:450 Construction nr:4C Area:6 Exposure:S U Value:0.87 SHGC:0.67 Heating BTUH:146 Cooling BTUH:104 Construction nr:4C Area:48 Exposure:S U Value:0.87 SHGC:0.67 Heating BTUH:1,169 Cooling BTUH:953 Construction nr:4C Area:6 Exposure:W U Value:0.87 SHGC:0.67 Heating BTUH:146 Cooling BTUH:255 Construction nr:4C Area:6 Exposure:S U Value:0.87 SHGC:0.67 Heating BTUH:146 Cooling BTUH:104 Construction nr:16DR-21 al U Value:0.044 Area:121 Heating BTUH:149 Cooling BTUH:160 Construction nr:16DR-21 al U Value:0.044 Area:408 Heating BTUH:503 Cooling BTUH:539 COMPONENT LOADS ABOVE GRADE WALLS System generated wall - S Poured Concrete, Stucco. System generated wall - E Poured Concrete, Stucco. System generated wall - S Poured Concrete, Stucco. System generated wall - S Poured Concrete, Stucco. System generated wall - W Poured Concrete, Stucco. System generated wall - S Poured Concrete, Stucco. BELOW GRADE WALLS There are no components for this section. WINDOWS Default small windows for wall id 443582 Window, NFRC rated, Low-e glass. Default small windows for wall id 443541 Window, NFRC rated, Low-e glass. Default medium windows for wall id 443541 Window, NFRC rated, Low-e glass. Default small windows for wall id 443482 Window, NFRC rated, Low-e glass. Default medium windows for wall id 443482 Window, NFRC rated, Low-e glass. Default small windows for wall id 443596 Window, NFRC rated, Low-e glass. Default small windows for wall id 443592 Window, NFRC rated, Low-e glass. Window cooling BTUHs shown here are daily average values. See AED graphs for details of fenestration loads during the day. CEILINGS System generated ceiling. Ceiling under attic or attic knee wall, Asphalt shingles, Light, R-21. System generated ceiling. Ceiling under attic or attic knee wall, Asphalt shingles, Light, R-21. Construction nr:16DR-21 al U Value:0.044 Area:72 Heating BTUH:89 Cooling BTUH:95 Construction nr:16DR-21 al U Value:0.044 Area:121 Heating BTUH:149 Cooling BTUH:160 Construction nr:22C-10ph Area:121 Heating U Value:0 Cooling U Value:0 Heating BTUH:376 Cooling BTUH:0 F Value:1.221 Construction nr:22C-10ph Area:408 Heating U Value:0 Cooling U Value:0 Heating BTUH:1,573 Cooling BTUH:0 F Value:1.221 Construction nr:22C-10ph Area:72 Heating U Value:0 Cooling U Value:0 Heating BTUH:615 Cooling BTUH:0 F Value:1.221 Construction nr:22C-10ph Area:121 Heating U Value:0 Cooling U Value:0 Heating BTUH:376 Cooling BTUH:0 F Value:1.221 Leakage Category:Average NCFM Heating:60 NCFM Cooling:31 Heating BTUH:1,837 Sensible BTUH:516 Latent BTUH:1,298 Nr. Occupants:4 Sensible BTUH:920 Latent BTUH:800 CEILINGS System generated ceiling. Ceiling under attic or attic knee wall, Asphalt shingles, Light, R-21. System generated ceiling. Ceiling under attic or attic knee wall, Asphalt shingles, Light, R-21. SKYLIGHTS There are no components for this section. Skylight cooling BTUHs shown here are daily average values. See AED graphs for details of fenestration loads during the day. DOORS There are no components for this section. FLOORS System generated floor. Concrete slab on grade floor, R-10 slab insulation. System generated floor. Concrete slab on grade floor, R-10 slab insulation. System generated floor. Concrete slab on grade floor, R-10 slab insulation. System generated floor. Concrete slab on grade floor, R-10 slab insulation. VENTILATION There are no components for this section. HOT WATER PIPING There are no components for this section. DUCTS There are no components for this section. INFILTRATION BLOWER MOTOR There are no components for this section. WINTER HUMIDIFICATION There are no components for this section. OCCUPANTS Small kitchen: 1,200 BTUH Quantity:Sensible BTUH:1,200 Latent BTUH: Plant Size:small Quantity:5 Latent BTUH:50 Plant Size:medium Quantity:5 Latent BTUH:100 Plant Size:large Quantity:5 Latent BTUH:150 APPLIANCES PLANTS Heated square footage:408 Cooled square footage:408 Heated volume (above grade CF):3,672 Cooled volume (above grade CF):3,672 Exposed wall area (SF):414 Total Cooling BTUH:5,571 Total Heating BTUH:8,279 CFM:242 ROOM DETAIL Room name: Kitchen/Dining Load Calculation 0 2,000 4,000 6,000 8,000 10,000 Cooling Heating BTUH AED Graph (mid-summer) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 1,000 2,000 3,000 BTUHAED graph (fall) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 2,000 4,000 6,000 BTUH Heated square footage:121 Cooled square footage:121 Heated volume (above grade CF):847 Cooled volume (above grade CF):847 Exposed wall area (SF):77 Total Cooling BTUH:903 Total Heating BTUH:1,553 CFM:34 ROOM DETAIL Room name: Office/den Load Calculation 0 500 1,000 1,500 2,000 Cooling Heating BTUH AED Graph (mid-summer) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 100 200 BTUHAED graph (fall) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 200 400 600 BTUH Heated square footage:121 Cooled square footage:121 Heated volume (above grade CF):847 Cooled volume (above grade CF):847 Exposed wall area (SF):77 Total Cooling BTUH:903 Total Heating BTUH:1,553 CFM:34 ROOM DETAIL Room name: Master Bedroom Load Calculation 0 500 1,000 1,500 2,000 Cooling Heating BTUH AED Graph (mid-summer) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 100 200 BTUHAED graph (fall) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 200 400 600 BTUH Heated square footage:72 Cooled square footage:72 Heated volume (above grade CF):504 Cooled volume (above grade CF):504 Exposed wall area (SF):126 Total Cooling BTUH:1,557 Total Heating BTUH:2,329 CFM:60 ROOM DETAIL Room name: Master Bath Load Calculation 0 500 1,000 1,500 2,000 2,500 Cooling Heating BTUH AED Graph (mid-summer) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 200 400 600 BTUHAED graph (fall) BTUH Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 190 200 400 600 BTUH