Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Site Plan Accordions
Castle Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS test a Mwtin Luther IGng Blvd NVIOS lack FL 3-MM 800.643.0371 Property Information Building Information Owner: SHAFER Wind Zone: 160 MPH. Address: WO# 12042020005 Exposure Category: C 6301 OLEANDER AVE Minimum Building Dimension: 55 ft. FORT PIERCE, FL 34982 Mean Roof Height: 15 ft. 41 Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 53.25 86.75 7 30.9 -33.8 2 Int 119.25 89.5 7 29.1 -32.0 3 Int 66.25 36.25 7 32.4 -35.2 4 End 84.5 93 7 29.8 -37.4 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1 Customer: SHAFER WorkOrder Number: 12042020005 N0301 Unit No. Wall Pressure Opening Width Opening Height Shutter Width Shutter Height Slat Length Anchor Spacing 1 33.8 57.75 86.75 68.75 86.5 83.25 9"O.c. 24"o.c. 2 32 119.25 89.5 140.75 92.5 89.25 9"O.c. 9"o.c. 3 35.2 66.25 36.25 82 41.25 38 9"O.c. 9"o.c. 4 37.4 84.5 93 99.75 92.75 89.5 24"o.c. 9"o.c.