Loading...
HomeMy WebLinkAboutSite Plan AccordionsCastle Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS test a Mwtin Luther IGng Blvd NVIOS lack FL 3-MM 800.643.0371 Property Information Building Information Owner: SHAFER Wind Zone: 160 MPH. Address: WO# 12042020005 Exposure Category: C 6301 OLEANDER AVE Minimum Building Dimension: 55 ft. FORT PIERCE, FL 34982 Mean Roof Height: 15 ft. 41 Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 53.25 86.75 7 30.9 -33.8 2 Int 119.25 89.5 7 29.1 -32.0 3 Int 66.25 36.25 7 32.4 -35.2 4 End 84.5 93 7 29.8 -37.4 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1 Customer: SHAFER WorkOrder Number: 12042020005 N0301 Unit No. Wall Pressure Opening Width Opening Height Shutter Width Shutter Height Slat Length Anchor Spacing 1 33.8 57.75 86.75 68.75 86.5 83.25 9"O.c. 24"o.c. 2 32 119.25 89.5 140.75 92.5 89.25 9"O.c. 9"o.c. 3 35.2 66.25 36.25 82 41.25 38 9"O.c. 9"o.c. 4 37.4 84.5 93 99.75 92.75 89.5 24"o.c. 9"o.c.