HomeMy WebLinkAboutBuilding plans- 503010-Rev1 - Digital Sealed1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-140" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. ------------------------------------------------------------ L-- - - - - -- -0" ON I US: SUB —GRADE SOILS: —TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION CONCRETE: —MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS: —MINIMUM GRADE 40 STEEL —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: —THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. —COVER: —2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 11" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }" FOR FINE GROUT, AND 4" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 11" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: —METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. "x5�" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES — AND EVERY OTHER END —WALL POST 2" MIN —BASE RAIL GRADE TT�7 I -III -I I ° I I If 1 I I I MINIMUM SOIL BEARING CAPACITY 2,000 PSF(TYP.) N 2,500 PSI 4" CONCRETE SLAB W.W.F. OR FIBER (2) #5 REBAR @ 6" O.C. CONTINUOUS WITH MINIMUM 12" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL 2 5" PLAN VIEW DOOR FRAMING J" RECESS 4" I OOR WIDTri ELEVATION VIEW DOOR FRAMING RECESS •75' "T L6;DOOR WIDTH OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES L-MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER �12"x12" REINFORCED FOOTER I SWINGING 0 DOOR I 0 ROLL —UP 0 DOOR R -------------------------------------i w 0 0 1 ire ;144 0�� 9 .WL L ma7ak,19'k, CODE VERSION FBC 2020 7th Edition, ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE ENCLOSED OPEN INTERNAL PRESSURE COEFF. +/— 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE INO HURRICANE SHELTER USAGE INO SQUARE FOOTAGE 11,500 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 1 12020 FBC, WINDSPEED 1/7/21 MTB MTB 5/17/20 N. Header Canal Rd., Ft. Pierce 50'L X 30'W X 1O'H . 9 ocENSF OLG�i NO.64608 2 i �':• STATE OF ; •4 WFLORIDP •; ��1�`�` to IIIII 0 Digitally signed by Matthew z Baldwin Date: 2021.01.07 11:00:02-05'00' z Q MattheW T. BaldWin P.E. Florida License #64608 Sheet: CA-1 OF 4 0' ROLL -UP DOOR MID END WALL -11j" I 3'-11j" I 3'-11j" I 3'-1 12 3L--- - D.C. FRONT END WALL SWINGING DOOR I . '-11 I 3'-11 " 3'-11f"- -050,_0" LEFT/RIGHT(MIRRORED) SIDE WALL PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES CODE VERSION FBC 2020 7th Edition, ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE ENCLOSED OPEN INTERNAL PRESSURE COEFF. +/- 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,500 SQ. FT. REVISIONS REVI DESCRIPTON I DATE I BY 1 12020 FBC, WINDSPEED 1 1/7/21 1 MTB MTB 5/17/20 N. Header Canal Rd., Ft. Pierce 50'L X 30'W X 10'H REAR END WALL Un _W C� z_ Q L� O.C. MAX. Z W Li Matthew T. BOIdWin P.E. Florida License #64608 -11 1j" 3'-4" 3'-4" 3'-4" 10'-0" 0 Sheet: CA-2 OF 4 FRONT/REAR END WALL FRONT END WALL SWINGING DOOR LEFT/RIGHT(MIRRORED) SIDE WALL �'s q1H �- F.;� mm, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES CODE VERSION FBC 2020 7th Edition, ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY JUTILITY, U WIND SPEED Vult-150mph REAR END WALL ENCLOSURE ENCLOSED OPEN INTERNAL PRESSURE COEFF. +/— 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,500 SQ. FT. REV I DESCRIPTON I DATE I BY 11 1 12020 FBC, WINDSPEED 1 1/7/21 1 MTB 11 MTB 5/17/20 N. Header Canal Rd., Ft. Pierce 50'L X 30'W X 1O'H W Z W Matthew T. BaldWin P.E. W Florida License #64608 Sheet: CA-3 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH S)#12 14xi" SELF —DRILLING CREWS4 T /V \BASE RAIL NIPPLE BASE f MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)REWS 14xi" SELF —DRILLING 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS POST TO BASE RAIL END POST TO BASE RAIL CONNECTION CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL INTERIOR #12-14xi" SELF —DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALL' EXTERIOR DOOR FRAME TO POST CONNECTION 18" IV 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS SINGLE OR DOUBLETS HEADER INTERMEDIATE POST TO HEADER/BASE RAIL/OR HEADER CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS r-VARIES MAX. SPACIN r--3" MIN. 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14xj" SELF —DRILLING SCREWS '2-1-2-1' (6" O.C. (9" O.C. MAX.)) kvA' M STD. MAX. SPRUCING VARIES SIDE WALL ROLL —UP DOOR/FRAME OUT HEADER DETAIL INSTALL PER MANUFACTURERS INSTRUCTIONS ,4"IPPLE TO #14x1" SELF —DRILLING SCREWS ® 6" O.C. MAX. & 6" MAX. FROM CORNERS ROLL —UP DOOR TO POST CONNECTION Design Pressures - 150 mph Basic Wind Speed Zone Roof Wall 1 2n 2r 2e 3r 3e 4 5 15.0 16.7 15.0 15.0 21.1 21.1 21.1 23.9 -18.0 -41.3 -34.4 -18.0 -66.5 -57.1 1 -22.7 -28.3 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-140" SELF —DRILLING SCREWS TO EACH RAFTER. ROOF PANEL CONNECTIO VERTICAL SHEATHING OPTION 1 "x2j" 16 GA. U—CHANNEL BRACE, MIN. 24" UP TO 7' POST, MIIN 48" OVER 7' POST. MIN. 45' TO MAX. 60' FROM HORIZ. (EXCLUDE END —WALLS). SECURED WITH (4)#12-14xi" SELF —DRILLING SCREWS. MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xi" SELF —DRILLING SCREWS BOX EAVE RAFTER TO POST CONNECTION DETAIL NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SCREWS 14x" SELF —DRILLING WMIMANYMBE SINGLE OR DOUBLETS IPPLE ASE I HEADER CONNECTION DETAIL OPTION 2 NI TO T TRUSSED RAFTER CONNECTION DETAIL MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xj" SELF —DRILLING SCREWS POST TO TRUSS CONNECTION APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 —R1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL12765.3—R5 SERIES 3100 CODE VERSION FBC 2020 7th Edition, ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph INTERNAL PRESSURE COEFF. +/— 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,500 SQ. FT. REVISIONS REVI DESCRIPTON I DATE I BY 1 12020 FBC, WINDSPEED 1 1/7/21 1 MTB u ".j - MTB DATE: 5/ 17/20 LOCATI 0 N. Header Canal Rd., Ft. Pierce SIZE: 50'L X 30'W X 10'H J Q Matthew T. Baldwin P.E. Florida License #64608 ww o Sheet: CA-4 OF 4 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES