HomeMy WebLinkAboutIn-Place Density Test ReportUniversal
Engineering
Sciences
Company
'17FRNAT�aNP
1e P-PM T ,;�00.2 00 50
UES Project No: 3360.1800067.0000
Workorder No: 221226-1
Report Date: 01/11/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924.3580
In -Place Density Test Report
Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Sean Hayes
1430 Culver Drive, NE Date Tested: 12/29/2020
Palm Bay, FL 32907
Project: 18-5043.03 CREEKSIDE
Various Locations,Vero Beach, County, FL 32967
Area Tested: 3205 Trinity Cir, Lot 67
Material: Native
Reference Datum: 0 = Top of Native
The tests below meet the 95% minimum compaction requirement
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Test
Maximum
Optimum
Field Dry
Field
Soil
Pass
No.
Density
Moisture
Density
Moisture
Compaction
or
Location of Test
Range
(pcf)
( % )
(Pcf)
(%)
( % )
Fail
1
NE Corner
0-1 ft
111.4
10.3
108.7
11.1
98
Pass
2
SW Corner
0-1 ft
111.4
10.3
107.5
10.3
96
Pass
3
Center
0-1 ft
111.4
10.3
109.9
10.6
99
Pass
Remarks: Permit 2002-0050
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
Digitally signed
J n by John Kent
Date:
Ken t 2021.01.1 1
09:20:14-05'00'
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1