HomeMy WebLinkAboutBuilding Input Summary ReportBuilding Input Summary Report
PROJECT
Title:
Powers Residence
Address type:
S
Building Type:
User
Bedrooms: 3
Lot#:
Owner:
Conditioned Area: 2427
Block/SubDivision:
Total Stories: 2
PlatBook:
Builder Name:
Worst Case: No
Street:
6418 Riverland Drive
Permit Office:
Rotate Angle: 0
County:
St. Lucie
Jurisdiction:
Cross Ventilation:
City, State, Zip:
Port St. Lucie,
Family Type:
Single-family
Whole House Fan:
FL, 34982
New/Existing:
New (From Plans)
Terrain: Urban
Year Construct:
2018
Shielding: Urban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp Heating
Design Daily temp
Location
Tmy Site
97.5% 2.5%
Winter Summer Degree Days
Moisture Range
FL, ST—LUCIE_CO_INTL
FL_VERO—BEACH_MUNICIPA 39 90
70 75 299
58 Medium
UTILITY
Fuel
Unit
Utility Name
Monthly Fixed Cost
$/Unit
Electricity
kWh
Florida Average
0.00
0.12
Natural Gas
Therm
Florida Average
0.00
1.72
Fuel Oil
Gallon
Florida Default
0.00
1.10
Propane
Gallon
Florida Default
0.00
1.40
SURROUNDINGS
-----------Shade Trees -------------
----------Adjacent Buildings-------
Ornt Type
Height Width Distance
Exist Height
Width Distance
N None
Oft Oft Oft
Oft
Oft Oft
NE None
Oft Oft Oft
Oft
Oft Oft
E None
Oft Oft Oft
Oft
Oft Oft
SE None
Oft Oft Oft
Oft
Oft Oft
S None
Oft Oft Oft
Oft
Oft Oft
SW None
Oft Oft Oft
Oft
Oft Oft
W None
Oft Oft Oft
Oft
Oft Oft
NW None
Oft Oft Oft
Oft
Oft Oft
BLOCKS
Number
Name
Area
Volume
1
Blockl
1627
17897
2
Block2
800
7200
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms Finished
Cooled Heated
1
AHU1
1627
17897 Yes 2
1 Yes
Yes Yes
2
AHU2
800
7200 No 2
2 Yes
Yes Yes
5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 1
Building Input Summary Report
FLOORS
(Total Exposed Area = 2427 sq.ft.)
#
Floor Type
Space
Exposed Perim Perimeter R-Value
Area Joist R-Value
Tile Wood Carpet
1
Slab -On -Grade Edge Ins AHU1
194 0.1
1627 ft --
0
0 1
2
Slab -On -Grade Edge Ins AHU2
119 0.1
800 ft -
0
0 1
ROOF
Roof Gable
Roof
Solar SA
Emitt Emitt
Deck Pitch
#
Type
Materials
Area Area
Color
Absor. Tested
Tested
Insul. (deg)
1
Gable or shed
Composition shingles 1762 ft2 338 ftz
Medium 0.75 No
0.9 No
22 22.6
ATTIC
#
Type
Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1
Full attic
Unvented
0
1627 ft2 N
N
CEILING
(Total Exposed Area = 1627 sq.ft.)
#
Ceiling Type
Space
R-Value Ins. Type
Area Framing Fraction Truss Type
1
Under Attic(Unvented)
AHU1
30.0 Blown
827.Oft2 0.11
Wood
2
Under Attic(Unvented)
AHU2
30.0 Blown
800.0ft2 0.11
Wood
WALLS
(Total Exposed Area = 3515 sq.ft.)
Adjacent
Cavity Width
Height Sheathing Framing
Solar Below
#
Ornt To
Wall Type
Space
R-Value Ft
In
Ft In Area R-Value Fraction
Absor. Grade
1
NE Exterior
Cone. Blk - Int Ins
AHU1
4.1 22.0
8
11.0 0 249.3ft2
0
0.5 0 %
2
NE Exterior
Cone. Blk - Int Ins
AHU1
4.1 32.0
8
11.0 0 359.3ft2
0
0.5 0 %
3
SE Exterior
Cone. Blk - Int Ins
AHU1
4.1 28.0
0
11.0 0 308.0ft2
0
0.5 0 %
4
SE Exterior
Cone. Blk - Int Ins
AHU1
4.1 16.0
0
11.0 0 176.0ft2
0
0.5 0 %
5
SW Exterior
Cone. Blk - Int Ins
AHU1
4.1 14.0
0
11.0 0 154.0ft2
0
0.5 0 %
6
SW Exterior
Cone. Blk - Int Ins
AHU1
4.1 18.0
8
11.0 0 205.3ft2
0
0.5 0 %
7
SW Garage
Frame - Steel
AHU1
13 22.0
8
11.0 0 249.3ft2
0
0.5 0 %
8
NW Exterior
Cone. Blk - Int Ins
AHU1
4.1 52.0
0
11.0 0 572.0ft2
0
0.5 0 %
9
NE Exterior
Cone. Blk - Int Ins
AHU2
4.1 33.0
4
9.0 0 300.0ft2
0
0.5 0 %
10 SE Exterior
Cone. Blk - Int Ins
AHU2
4.1 28.0
0
9.0 0 252.0ft2
0
0.6 0 %
11 SW Exterior
Cone. Blk - Int Ins
AHU2
4.1 33.0
4
9.0 0 300.Oft2
0
0.5 0 %
12 NW Exterior
Cone. Blk - Int Ins
AHU2
4.1 28.0
0
9.0 0 252.0ft2
0
0.5 0 %
13 NW Garage
Frame - Steel
AHU1
13 12.0
6
11.0 0 137.5ft2
0
0.75 0 %
WINDOWS
(Total Exposed Area = 437 sq.ft.)
Wall
-Overhang-
#
Ornt ID Frame
Panes NFRC
U-Factor SHGC Imp Storm
Area
Depth Separation
Interior Shade
Screening
1
NE 1 Metal
Single (Clear) Yes
0.94
0.36 Y N
40.0ft2
1.0 ft 6 in 2.0 ft 0 in
Drapes/blinds.
None
2
NE 2 Metal
Single (Clear) Yes
1.11
0.27 Y N
64.0ft2
9.0 ft 4 in 2.0 ft 0 in
Drapes/blinds
None
3
NE 2 Metal
Single (Clear) Yes
0.94
0.36 Y N
40.0ft2
9.0 ft 4 in 2.0 ft 0 in
Drapes/blinds
None
4
NE 2 Metal
Single (Clear) Yes
0.99
0.33 Y N
5.3ft2
9.0 ft 4 in 2.0 ft 0 in
Drapes/blinds
None
5
SE 3 Metal
Single (Clear) Yes
0.99
0.33 Y N
5.3ft2
4.0 ft 6 in 2.0 ft 0 in
Drapes/blinds
None
6
SE 4 Metal
Single (Clear) Yes
1.11
0.27 Y N
48.0ft2
14.0 ft 0 in 1.0 ft 0 in
Drapes/blinds
None
7
SE 4 Metal
Single (Clear) Yes
1.02
0.29 Y N
37.3ft2
14.0 ft 0 in 1.0 ft 0 in
Drapes/blinds
None
8
SW 5 Metal
Single (Clear) Yes
0.99
0.33 Y N
13.3ft2
6.0 ft 8 in 2.0 ft 0 in
Drapes/blinds
None
9
SW 6 Metal
Single (Clear) Yes
1.07
0.30 Y N
20.0ft2
1.0 ft 6 in 2.0 ft 0 in
Drapes/blinds
None
10 SW 6 Metal
Single (Clear) Yes
1.07
0.30 Y N
20.0ft2
1.0 ft 6 in 2.0 ft 0 in
Drapes/blinds
None
5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 2
Building Input Summary Report
WINDOWS(Continued)
11 NW
12 NW
13 NW
14 NE
15 NE
16 SE
17 SE
18 SW
19 SW
8 Metal
8 Metal
8 Metal
9 Metal
9 Metal
10 Metal
10 Metal
11 Metal
11 Metal
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Single (Clear)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.99 0.33 Y N 13.3ft2 1.0 ft 6 in
1.07 0.30 Y N 15.6ft2 1.0 ft 6 in
1.07 0.30 Y N 15.6ft2 1.0 ft 6 in
1.07 0.33 Y N 18.7ftz 1.0 ft 6 in
0.94 0.36 Y N 40.Oftz 1.0 ft 6 in
0.99 0.33 Y N 5.3ft2 1.0 ft 6 in
0.99 0.33 Y N 5.3ft2 1.0 ft 6 in
0.99 0.33 Y N 11.1ft2 1.0 ft 6 in
1.07 0.30 Y N 18.7ft2 1.0 ft 6 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
2.0 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope Method
SLA
CFM50 -ELA EgLA ACH ACH50
Space(s)
1
Wholehouse Proposed ACH(50)
0.00026 1673 91.85 172.74 0.2427
4.0
All
GARAGE
#
Floor Area
Roof Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
440 ft2
440 ft2
44 ft 8 ft
1
MASS
#
Mass Type
Area
Thickness Furniture Fraction Space
1
2
No Added Mass
No Added Mass
0 ft2
0 ft2
0 ft 0.30
0 ft 0.30
AHU1
AHU2
HEATING SYSTEM
#
System Type
Subtype
AHRI # Efficiency Capacity ----Geothermal HeatPump--- Ducts
kBtu/hr Entry Power Volt Current
Block
1
2
Electric Heat Pump
Electric Heat Pump
None
None
HSPF: 11.00 50.5
HSPF: 10.50 24.4
0.00
0.00
0.00 0.00 sys#1
0.00 0.00 sys#2
1
2
COOLING SYSTEM
#
System Type
Subtype
AHRI # Efficiency Capacity
kBtu/hr
Air Flow
cfm
SHR Duct
Block
1
2
Central Unit
Central Unit
Split
Split
SEER:16 46.0
SEER:16 24.0
1380
720
0.75 sys#1
0.75 sys#2
1
2
HOT WATER SYSTEM
#
System Type Subtype
Location EF Cap Use SetPnt
Fixture Flow
Pipe Ins. Pipe length
1
Electric Heat Pump
AHU1
3.50 80.00 gal 60 gal 120 deg
Standard
None
112
Recirculation
System
Recirc Control
Type
Loop Branch Pump DWHR Facilities
length length power Connected
Equal
Flow
DWHR Other Credits
Eff
1
No
NA NA NA No NA
NA
NA None
5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 3
Building Input Summary Report
DUCTS
Duct-------Supply-------
--------Return- ---
Air
CFM 25
CFM 25
HVAC #
# Location
R-Value
Area Location R-Value Area Leakage
Type
Handler
TOT
OUT
QN
RLF Heat Cool
1 AHU1
6.0 125 ft'
AHU1
6.0 40 ft2 Default Leakage
Garage
(Default) (Default)
1 1
2 Attic
6.0 85 ft'
Attic
6.0 30 ft' Default Leakage
Attic
(Default) (Default)
2 2
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans: N
Cooling [ ] Jan
[] Feb
[ ] Mar
[ ] Apr
[ ] May [X] Jun
[X] Jul
[)CI Aug
[X] Sep
[ ] Oct
[ ] Nov
[ ] Dec
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May [ ] Jun
[ ] Jul
[ ] Aug
[ ] Sep
[ ] Oct
[X] Nov
[X] Dec
Venting [ ] Jan
[] Feb
[X] Mar
[X] Apr
[ ] May [ ] Jun
[ ] Jul
[ ] Aug
[ ] Sep
[X] Oct
[X] Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78 78 78
78
78
78
80
80
80
80
PM
80
80
78 78 78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78 78 78
78
78
78
78
78
78
78
PM
78
78
78 78 78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66 66 66
68
68
68
68
68
68
68
PM
68
68
68 68 68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66 66 66
68
68
68
68
68
68
68
PM
68
68
68 68 68
68
68
68
68
68
66
66
MISC ELECTRICAL LOADS
ID Type
Screen
Location
Item Quantity Category
Operating Schedule
Off Standby
1 Misc Elec Load Simple Default
Main
1
1
HERS2011
1
APPLIANCES & LIGHTING SCHEDULES
Appliance Schedule:
HERS2014
Hours
Schedule Type
1
2
3 4 5
6
7
8
9
10
11
12
Occupancy peak:
400 Btu
AM
0.930
0.930
0.930 0.930 0.930
0.930
0.930
0.980
0.460
0.270
0.270
0.270
% Released:
100 %
PM
0.270
0.270
0.270 0.270 0.330
0.610
1.000
1.000
0.930
0.930
0.930
0.930
refrig peak:
0 W
AM
0.824
0.804
0.784 0.764 0.744
0.734
0.744
0.754
0.764
0.794
0.814
0.854
% Released:
100 %
PM
0.854
0.864
0.884 0.904 0.925
0.945
0.925
0.915
0.904
0.894
0.874
0.854
cWash peak:
0 W
AM
0.200
0.100
0.050 0.050 0.050
0.075
0.200
0.375
0.500
0.800
0.950
1.000
% Released:
30 %
PM
0.875
0.850
0.800 0.625 0.625
0.600
0.575
0.550
0.625
0.700
0.650
0.375
E-cDry peak:
0 W
AM
0.200
0.100
0.050 0.050 0.050
0.075
0.200
0.375
0.500
0.800
0.950
1.000
% Released:
15 %
PM
0.875
0.850
0.800 0.625 0.625
0.600
0.575
0.550
0.625
0.700
0.650
0.375
dWash peak:
0 W
AM
0.139
0.050
0.028 0.024 0.029
0.090
0.169
0.303
0.541
0.594
0.502
0.443
% Released:
60 %
PM
0.376
0.396
0.334 0.323 0.344
0.448
0.791
1.000
0.800
0.597
0.383
0.281
E-rOven peak:
0 W
AM
0.057
0.057
0.057 0.057 0.057
0.114
0.171
0.286
0.343
0.343
0.343
0.400
% Released:
80 %
PM
0.457
0.343
0.286 0.400 0.571
1.000
0.857
0.429
0.286
0.229
0.171
0.114
TVs peak:
226 W
AM
0.100
0.050
0.050 0.050 0.100
0.200
0.400
0.450
0.400
0.200
0.100
0.100
% Released:
100 %
PM
0.050
0.050
0.150 0.450 0.850
1.000
0.950
0.800
0.500
0.250
0.150
0.100
cFan peak:
0 W
AM
0.600
0.600
0.600 0.600 0.600
0.600
0.600
0.250
0.250
0.250
0.250
0.250
% Released:
100 %
PM
0.250
0.250
0.250 0.250 0.250
0.250
0.550
0.600
0.600
0.600
0.600
0.600
5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 4
a I I a
Building Input Summary Report
APPLIANCES & LIGHTING SCHEDULES(Continued)
Igts-in peak:
0 W
AM
0.160
0.150
0.160
0.180
0.230
0.450
0.420
0.260
0.190
0.160
0,120
0,110
% Released:
100 %
PM
0.160
0.170
0.250
0.270
0.340
0.550
0.600
0.880
1.000
0.880
0.510
0.280
Igts-out peak:
0 W
AM
1.000
1.000
1.000
1.000
1.000
0.750
0.750
0.000
0.000
0.000
0.000
0.000
% Released:
0 %
PM
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.500
0.750
0.750
0.750
1.000
Igts-gar peak:
0 W
AM
0.000
0.000
0.000
0.000
0.000
0.500
0.750
1.000
0.750
0.500
0.000
0.000
% Released:
0 %
PM
0.000
0.000
0.500
0.500
0.750
1.000
0.750
0.500
0.000
0.000
0.000
0.000
MEL peak:
0 W
AM
0.500
0.500
0.500
0.750
0.750
0.850
1.000
1.000
1.000
1.000
0.900
0.900
% Released:
90 %
PM
0.900
0.900
1.000
1.000
1.000
1.000
1.000
1.000
1.000
0.850
0.750
0.750
5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 5 of 5