Loading...
HomeMy WebLinkAboutBuilding Input Summary ReportBuilding Input Summary Report PROJECT Title: Powers Residence Address type: S Building Type: User Bedrooms: 3 Lot#: Owner: Conditioned Area: 2427 Block/SubDivision: Total Stories: 2 PlatBook: Builder Name: Worst Case: No Street: 6418 Riverland Drive Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip: Port St. Lucie, Family Type: Single-family Whole House Fan: FL, 34982 New/Existing: New (From Plans) Terrain: Urban Year Construct: 2018 Shielding: Urban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, ST—LUCIE_CO_INTL FL_VERO—BEACH_MUNICIPA 39 90 70 75 299 58 Medium UTILITY Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Average 0.00 0.12 Natural Gas Therm Florida Average 0.00 1.72 Fuel Oil Gallon Florida Default 0.00 1.10 Propane Gallon Florida Default 0.00 1.40 SURROUNDINGS -----------Shade Trees ------------- ----------Adjacent Buildings------- Ornt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft BLOCKS Number Name Area Volume 1 Blockl 1627 17897 2 Block2 800 7200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 AHU1 1627 17897 Yes 2 1 Yes Yes Yes 2 AHU2 800 7200 No 2 2 Yes Yes Yes 5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 1 Building Input Summary Report FLOORS (Total Exposed Area = 2427 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins AHU1 194 0.1 1627 ft -- 0 0 1 2 Slab -On -Grade Edge Ins AHU2 119 0.1 800 ft - 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1762 ft2 338 ftz Medium 0.75 No 0.9 No 22 22.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1627 ft2 N N CEILING (Total Exposed Area = 1627 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area Framing Fraction Truss Type 1 Under Attic(Unvented) AHU1 30.0 Blown 827.Oft2 0.11 Wood 2 Under Attic(Unvented) AHU2 30.0 Blown 800.0ft2 0.11 Wood WALLS (Total Exposed Area = 3515 sq.ft.) Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Absor. Grade 1 NE Exterior Cone. Blk - Int Ins AHU1 4.1 22.0 8 11.0 0 249.3ft2 0 0.5 0 % 2 NE Exterior Cone. Blk - Int Ins AHU1 4.1 32.0 8 11.0 0 359.3ft2 0 0.5 0 % 3 SE Exterior Cone. Blk - Int Ins AHU1 4.1 28.0 0 11.0 0 308.0ft2 0 0.5 0 % 4 SE Exterior Cone. Blk - Int Ins AHU1 4.1 16.0 0 11.0 0 176.0ft2 0 0.5 0 % 5 SW Exterior Cone. Blk - Int Ins AHU1 4.1 14.0 0 11.0 0 154.0ft2 0 0.5 0 % 6 SW Exterior Cone. Blk - Int Ins AHU1 4.1 18.0 8 11.0 0 205.3ft2 0 0.5 0 % 7 SW Garage Frame - Steel AHU1 13 22.0 8 11.0 0 249.3ft2 0 0.5 0 % 8 NW Exterior Cone. Blk - Int Ins AHU1 4.1 52.0 0 11.0 0 572.0ft2 0 0.5 0 % 9 NE Exterior Cone. Blk - Int Ins AHU2 4.1 33.0 4 9.0 0 300.0ft2 0 0.5 0 % 10 SE Exterior Cone. Blk - Int Ins AHU2 4.1 28.0 0 9.0 0 252.0ft2 0 0.6 0 % 11 SW Exterior Cone. Blk - Int Ins AHU2 4.1 33.0 4 9.0 0 300.Oft2 0 0.5 0 % 12 NW Exterior Cone. Blk - Int Ins AHU2 4.1 28.0 0 9.0 0 252.0ft2 0 0.5 0 % 13 NW Garage Frame - Steel AHU1 13 12.0 6 11.0 0 137.5ft2 0 0.75 0 % WINDOWS (Total Exposed Area = 437 sq.ft.) Wall -Overhang- # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening 1 NE 1 Metal Single (Clear) Yes 0.94 0.36 Y N 40.0ft2 1.0 ft 6 in 2.0 ft 0 in Drapes/blinds. None 2 NE 2 Metal Single (Clear) Yes 1.11 0.27 Y N 64.0ft2 9.0 ft 4 in 2.0 ft 0 in Drapes/blinds None 3 NE 2 Metal Single (Clear) Yes 0.94 0.36 Y N 40.0ft2 9.0 ft 4 in 2.0 ft 0 in Drapes/blinds None 4 NE 2 Metal Single (Clear) Yes 0.99 0.33 Y N 5.3ft2 9.0 ft 4 in 2.0 ft 0 in Drapes/blinds None 5 SE 3 Metal Single (Clear) Yes 0.99 0.33 Y N 5.3ft2 4.0 ft 6 in 2.0 ft 0 in Drapes/blinds None 6 SE 4 Metal Single (Clear) Yes 1.11 0.27 Y N 48.0ft2 14.0 ft 0 in 1.0 ft 0 in Drapes/blinds None 7 SE 4 Metal Single (Clear) Yes 1.02 0.29 Y N 37.3ft2 14.0 ft 0 in 1.0 ft 0 in Drapes/blinds None 8 SW 5 Metal Single (Clear) Yes 0.99 0.33 Y N 13.3ft2 6.0 ft 8 in 2.0 ft 0 in Drapes/blinds None 9 SW 6 Metal Single (Clear) Yes 1.07 0.30 Y N 20.0ft2 1.0 ft 6 in 2.0 ft 0 in Drapes/blinds None 10 SW 6 Metal Single (Clear) Yes 1.07 0.30 Y N 20.0ft2 1.0 ft 6 in 2.0 ft 0 in Drapes/blinds None 5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 2 Building Input Summary Report WINDOWS(Continued) 11 NW 12 NW 13 NW 14 NE 15 NE 16 SE 17 SE 18 SW 19 SW 8 Metal 8 Metal 8 Metal 9 Metal 9 Metal 10 Metal 10 Metal 11 Metal 11 Metal Single (Clear) Single (Clear) Single (Clear) Single (Clear) Single (Clear) Single (Clear) Single (Clear) Single (Clear) Single (Clear) Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.99 0.33 Y N 13.3ft2 1.0 ft 6 in 1.07 0.30 Y N 15.6ft2 1.0 ft 6 in 1.07 0.30 Y N 15.6ft2 1.0 ft 6 in 1.07 0.33 Y N 18.7ftz 1.0 ft 6 in 0.94 0.36 Y N 40.Oftz 1.0 ft 6 in 0.99 0.33 Y N 5.3ft2 1.0 ft 6 in 0.99 0.33 Y N 5.3ft2 1.0 ft 6 in 0.99 0.33 Y N 11.1ft2 1.0 ft 6 in 1.07 0.30 Y N 18.7ft2 1.0 ft 6 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in 2.0 ft 0 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds None None None None None None None None None INFILTRATION # Scope Method SLA CFM50 -ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 1673 91.85 172.74 0.2427 4.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 44 ft 8 ft 1 MASS # Mass Type Area Thickness Furniture Fraction Space 1 2 No Added Mass No Added Mass 0 ft2 0 ft2 0 ft 0.30 0 ft 0.30 AHU1 AHU2 HEATING SYSTEM # System Type Subtype AHRI # Efficiency Capacity ----Geothermal HeatPump--- Ducts kBtu/hr Entry Power Volt Current Block 1 2 Electric Heat Pump Electric Heat Pump None None HSPF: 11.00 50.5 HSPF: 10.50 24.4 0.00 0.00 0.00 0.00 sys#1 0.00 0.00 sys#2 1 2 COOLING SYSTEM # System Type Subtype AHRI # Efficiency Capacity kBtu/hr Air Flow cfm SHR Duct Block 1 2 Central Unit Central Unit Split Split SEER:16 46.0 SEER:16 24.0 1380 720 0.75 sys#1 0.75 sys#2 1 2 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric Heat Pump AHU1 3.50 80.00 gal 60 gal 120 deg Standard None 112 Recirculation System Recirc Control Type Loop Branch Pump DWHR Facilities length length power Connected Equal Flow DWHR Other Credits Eff 1 No NA NA NA No NA NA NA None 5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 3 Building Input Summary Report DUCTS Duct-------Supply------- --------Return- --- Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 AHU1 6.0 125 ft' AHU1 6.0 40 ft2 Default Leakage Garage (Default) (Default) 1 1 2 Attic 6.0 85 ft' Attic 6.0 30 ft' Default Leakage Attic (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Cooling [ ] Jan [] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [)CI Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MISC ELECTRICAL LOADS ID Type Screen Location Item Quantity Category Operating Schedule Off Standby 1 Misc Elec Load Simple Default Main 1 1 HERS2011 1 APPLIANCES & LIGHTING SCHEDULES Appliance Schedule: HERS2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Occupancy peak: 400 Btu AM 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.980 0.460 0.270 0.270 0.270 % Released: 100 % PM 0.270 0.270 0.270 0.270 0.330 0.610 1.000 1.000 0.930 0.930 0.930 0.930 refrig peak: 0 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854 % Released: 100 % PM 0.854 0.864 0.884 0.904 0.925 0.945 0.925 0.915 0.904 0.894 0.874 0.854 cWash peak: 0 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 % Released: 30 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 E-cDry peak: 0 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 % Released: 15 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 dWash peak: 0 W AM 0.139 0.050 0.028 0.024 0.029 0.090 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 % PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1.000 0.800 0.597 0.383 0.281 E-rOven peak: 0 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.400 % Released: 80 % PM 0.457 0.343 0.286 0.400 0.571 1.000 0.857 0.429 0.286 0.229 0.171 0.114 TVs peak: 226 W AM 0.100 0.050 0.050 0.050 0.100 0.200 0.400 0.450 0.400 0.200 0.100 0.100 % Released: 100 % PM 0.050 0.050 0.150 0.450 0.850 1.000 0.950 0.800 0.500 0.250 0.150 0.100 cFan peak: 0 W AM 0.600 0.600 0.600 0.600 0.600 0.600 0.600 0.250 0.250 0.250 0.250 0.250 % Released: 100 % PM 0.250 0.250 0.250 0.250 0.250 0.250 0.550 0.600 0.600 0.600 0.600 0.600 5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 4 a I I a Building Input Summary Report APPLIANCES & LIGHTING SCHEDULES(Continued) Igts-in peak: 0 W AM 0.160 0.150 0.160 0.180 0.230 0.450 0.420 0.260 0.190 0.160 0,120 0,110 % Released: 100 % PM 0.160 0.170 0.250 0.270 0.340 0.550 0.600 0.880 1.000 0.880 0.510 0.280 Igts-out peak: 0 W AM 1.000 1.000 1.000 1.000 1.000 0.750 0.750 0.000 0.000 0.000 0.000 0.000 % Released: 0 % PM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.750 0.750 0.750 1.000 Igts-gar peak: 0 W AM 0.000 0.000 0.000 0.000 0.000 0.500 0.750 1.000 0.750 0.500 0.000 0.000 % Released: 0 % PM 0.000 0.000 0.500 0.500 0.750 1.000 0.750 0.500 0.000 0.000 0.000 0.000 MEL peak: 0 W AM 0.500 0.500 0.500 0.750 0.750 0.850 1.000 1.000 1.000 1.000 0.900 0.900 % Released: 90 % PM 0.900 0.900 1.000 1.000 1.000 1.000 1.000 1.000 1.000 0.850 0.750 0.750 5/17/2018 6:58:37 AM EnergyGauge® / USRCSB v6.0 Page 5 of 5