Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Powers Residence Builder Name: Street: 6418 Riverland Drive Permit Office: City, State, Zip: Port St. Lucie, FL , 34982 Permit Number: Owner: Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3514.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 3128.00ft2 b. Frame- Steel, Adjacent R=13.0 386.83 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10. Ceiling Types (1627.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 1627.00 ft' 6. Conditioned floor area above grade(ftz) 2427 b. N/A R= ft2 Conditionedfloorarea belowgrade(ftz) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(436.9 sqft.) Description Area a. Sup: AHU1, Ret:AHU1, AH: Garage 6 125 a. U-Factor: Sgl, U=0.94 120.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 85 SHGC: SHGC=0.36 b. U-Factor: Sgl, U=1.11 112.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 46.0 SEER:16.00 b. Central Unit 24.0 SEER:16.00 c. U-Factor: Sgl, U=1.07 89.78 ft2 SHGC: SHGC=0.30 13. Heating systems kBtulhr Efficiency d. U-Factor: other (see details) 115.11 ft2 a. Electric Heat Pump 50.5 HSPF:11.00 SHGC: other (see details) b. Electric Heat Pump 24.4 HSPF:10.50 Area Weighted Average Overhang Depth: 6.096 ft. Area Weighted Average SHGC: 0.313 14. Hot water systems a. Electric Cap: 80 gallonsEF:3.500 8. FloorTypes (2427.0 sqft.) Insulation Area a. Slab -On -Grade Edge Insulation R=0.1 2427.00ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.180 Total Proposed Modified Loads: 62.00 PASS Total Baseline Loads: 81.16 I hereby certify that the pla covered by Review of the plans and 4� S7Ap this calculation are in c �hf ner specifications covered by this �' � _ Code. ..••'"''•.,RHO calculation indicates compliance �P • � •. with the Florida Energy Code. PREPARED BY' �' Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * �' • �• ; • I hereby certify th �• ilding mooed, is. iance Florida Statutes. with the Florida En e. • •; OWNER/AGENT: Cam' •'� BUILDING OFFICIAL: DATE: 0sli'•••" DATE: - Compliance requires certific he air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 4.00 ACH50 (R402.4.1.2). 5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017Section R405.4.1 Compliant Software Page 1 of 5 FILE COPY FORM R405-2017 PROJECT Title: Powers Residence Bedrooms: 3 Address Type: Street Address Building Type: User ConditionedArea: 2427 Lot# Owner Name: Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6418 Riverland Drive Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie, Family Type: Single-family FL, 34982 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1627 17897 2 Block2 800 7200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AHU1 1627 17897 Yes 2 1 1 Yes Yes Yes 2 AHU2 800 7200 No 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation AHU1 194 ft 0.1 1627 ft2 ____ 0 0 1 2 Slab -On -Grade Edge Insulation AHU2 119 ft 0.1 800 ftZ 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 . Gable or shed Composition shingles 1762 ft2 338 ft2 Medium 0.75 No 0.9 No 22 22.6 ATTIC / V # Type • Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1627 ft2 N N 5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value. Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) AHU1 30 Blown 827 ft2 0.11 Wood 2 Under Attic (Unvented) AHU2 30 Blown 800 ft2 0.11 Wood WALLS V # r)rnt Adjacent To Wall Type Space Cavity R--A/:;Il a Width Ft In Height Ft In Area Sheathing Framing Solar R-41aille Fraction Ahsor Below Cmrie% 1 NE Exterior Concrete Block- Int Insul AHU1 4.1 22 8 11 249.3 ft2 0 0.5 0 2 NE Exterior Concrete Block - Int Insul AHU1 4.1 32 8 11 359.3 ft2 0 0.5 0 3 SE Exterior Concrete Block- Int Insul AHU1 4.1 28 0 11 308.0 ft2 0 0.5 0 4 SE Exterior Concrete Block- Int Insul AHU1 4.1 16 0 11 176.0 ft2 0 0.5 0 5 SW Exterior Concrete Block- Int Insul AHU1 4.1 14 0 11 154.0 ft2 0 0.5 0 6 SW Exterior Concrete Block- Int Insul AHU1 4.1 18 8 11 205.3 ft2 0 0.5 0 7 SW Garage Frame - Steel AHU1 13 22 8 11 249.3ft2 0 0.5 0 8 NW Exterior Concrete Block - Intlnsul AHU1 4.1 52 11 572.0ft2 0 0.5 0 9 NE Exterior Concrete Block- Int Insul AHU2 4.1 33 4 9 300.0 ft2 0 0.5 0 10 SE Exterior Concrete Block- Int Insul AHU2 4.1 28 0 9 252.0 ft2 0 0.5 0 11 SW Exterior Concrete Block- Int Insul AHU2 4.1 33 4 9 300.0 ft2 0 0.5 0 12 NW Exterior Concrete Block- Int Insul AHU2 4.1 28 0 9 252.0 ft2 0 0.5 0 13 NW Garage Frame- Steel AHU1 13 12 6 11 137.5 ft2 0 0.75 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Single (Clear) Yes 0.94 0.36 Y 40.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 2 NE 2 Metal Single (Clear) Yes 1.11 0.27 Y 64.0 ft2 9 ft 4 in 2 ft 0 in Drapes/blinds None 3 NE 2 Metal Single (Clear) Yes 0.94 0.36 Y 40.0 ft2 9 ft 4 in 2 ft 0 in Drapes/blinds None 4 NE 2 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ft2 9 ft 4 in 2 ft 0 in Drapes/blinds None 5 SE 3 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ft2 4 ft 6 in 2 ft 0 in Drapes/blinds None 6 SE 4 Metal Single (Clear) Yes 1.11 0.27 Y 48.0 ft2 14 ft 0 in 1 ft 0 in Drapes/blinds None 7 SE 4 Metal Single (Clear) Yes 1.02 0.29 Y 37.3 ft2 14 ft 0 in 1 ft 0 in Drapes/blinds None 8 SW 5 Metal Single (Clear) Yes 0.99 0.33 Y 13.3 ft2 6 ft 8 in 2 ft 0 in Drapes/blinds None 9 SW 6 Metal Single (Clear) Yes 1.07 0.3 Y 20.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 10 SW 6 Metal Single (Clear) Yes 1.07 0.3 Y 20.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 11 NW 8 Metal Single (Clear) Yes 0.99 0.33 Y 13.3 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 12 NW 8 Metal Single (Clear) Yes 1.07 0.3 Y 15.6 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 13 NW 8 Metal Single (Clear) Yes 1.07 0.3 Y 15.6 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 14 NE 9 Metal Single (Clear) Yes 1.07 0.33 Y 18.7 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 15 NE 9 Metal Single (Clear) Yes 0.94 0.36 Y 40.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 16 SE 10 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 17 SE 10 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 18 SW 11 Metal Single (Clear) Yes 0.99 0.33 Y 11.1 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 19 SW 11 Metal Single (Clear) Yes 1.07 0.3 Y 18.7 f12 1 ft 6 in 2 ft 0 in Drapes/blinds None 5/17/2018 6:57 AM EnergyGauge@USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 44 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000263 1673.1 91.85 172.74 .2427 4 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump/ Electric Heat Pump/ None None HSPF:11 50.5 kBtu/hr 1 HSPF:10.5 24.4 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 16 46 kBtu/hr 1380 cfm 0.75 1 SEER: 16 24 kBtu/hr 720 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump AHU1 3.5 80 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # CompanyName Collector Storage System Model# CollectorModel# Area Volume FEF None None ftZ DUCTS V # --- Supply -- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area LeakageType Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 AHU1 6 125 ft2 Attic 6 85 ft2 AHU1 Attic 40 ft2 Default Leakage Garage (Default) c(Default) c 30 ft2 Default Leakage Attic (Default) c(Default) c 1 1 2 2 5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Cooling Jan Heat in Jan Feb Feb Mar Mar A r A r Ma Ma Jun Jun Jul Jul Au Au Se Se Oct Oct Nov Nov Dec Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5