HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Powers Residence
Builder Name:
Street: 6418 Riverland Drive
Permit Office:
City, State, Zip: Port St. Lucie, FL , 34982
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3514.8 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 3128.00ft2
b. Frame- Steel, Adjacent
R=13.0 386.83 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d.N/A
R= ft2
10. Ceiling Types (1627.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=22.0 1627.00 ft'
6. Conditioned floor area above grade(ftz) 2427
b. N/A
R= ft2
Conditionedfloorarea belowgrade(ftz) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(436.9 sqft.) Description Area
a. Sup: AHU1, Ret:AHU1, AH: Garage
6 125
a. U-Factor: Sgl, U=0.94 120.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 85
SHGC: SHGC=0.36
b. U-Factor: Sgl, U=1.11 112.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
46.0 SEER:16.00
b. Central Unit
24.0 SEER:16.00
c. U-Factor: Sgl, U=1.07 89.78 ft2
SHGC: SHGC=0.30
13. Heating systems
kBtulhr Efficiency
d. U-Factor: other (see details) 115.11 ft2
a. Electric Heat Pump
50.5 HSPF:11.00
SHGC: other (see details)
b. Electric Heat Pump
24.4 HSPF:10.50
Area Weighted Average Overhang Depth: 6.096 ft.
Area Weighted Average SHGC: 0.313
14. Hot water systems
a. Electric
Cap: 80 gallonsEF:3.500
8. FloorTypes (2427.0 sqft.) Insulation Area
a. Slab -On -Grade Edge Insulation R=0.1 2427.00ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.180 Total Proposed Modified Loads: 62.00
PASS
Total Baseline Loads: 81.16
I hereby certify that the pla covered by
Review of the plans and
4� S7Ap
this calculation are in c �hf ner
specifications covered by this
�' � _
Code. ..••'"''•.,RHO
calculation indicates compliance
�P
• � •.
with the Florida Energy Code.
PREPARED BY' �'
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
* �'
• �• ; •
I hereby certify th �• ilding mooed, is. iance
Florida Statutes.
with the Florida En e.
• •;
OWNER/AGENT: Cam' •'�
BUILDING OFFICIAL:
DATE: 0sli'•••"
DATE:
- Compliance requires certific he air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 4.00 ACH50 (R402.4.1.2).
5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017Section R405.4.1 Compliant Software Page 1 of 5
FILE COPY
FORM R405-2017
PROJECT
Title:
Powers Residence
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
ConditionedArea: 2427
Lot#
Owner Name:
Total Stories: 2
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
6418 Riverland Drive
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Port St. Lucie,
Family Type:
Single-family
FL, 34982
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
1/ Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299
58
Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1627 17897
2
Block2
800 7200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
AHU1
1627 17897 Yes 2
1
1 Yes
Yes
Yes
2
AHU2
800 7200 No 2
2
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation AHU1 194 ft 0.1
1627 ft2
____
0 0
1
2 Slab -On -Grade Edge Insulation AHU2 119 ft 0.1
800 ftZ
0 0
1
ROOF
V
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
#
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
. Gable or shed Composition shingles 1762 ft2 338 ft2 Medium
0.75
No 0.9
No 22
22.6
ATTIC
/
V #
Type •
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0
1627 ft2
N N
5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
CEILING
#
Ceiling Type
Space
R-Value.
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
AHU1
30
Blown
827 ft2
0.11
Wood
2
Under Attic (Unvented)
AHU2
30
Blown
800 ft2
0.11
Wood
WALLS
V #
r)rnt
Adjacent
To Wall Type
Space
Cavity
R--A/:;Il a
Width
Ft In
Height
Ft In
Area
Sheathing Framing Solar
R-41aille Fraction Ahsor
Below
Cmrie%
1
NE
Exterior
Concrete Block- Int Insul
AHU1
4.1
22
8
11
249.3 ft2
0 0.5
0
2
NE
Exterior
Concrete Block - Int Insul
AHU1
4.1
32
8
11
359.3 ft2
0 0.5
0
3
SE
Exterior
Concrete Block- Int Insul
AHU1
4.1
28
0
11
308.0 ft2
0 0.5
0
4
SE
Exterior
Concrete Block- Int Insul
AHU1
4.1
16
0
11
176.0 ft2
0 0.5
0
5
SW
Exterior
Concrete Block- Int Insul
AHU1
4.1
14
0
11
154.0 ft2
0 0.5
0
6
SW
Exterior
Concrete Block- Int Insul
AHU1
4.1
18
8
11
205.3 ft2
0 0.5
0
7
SW
Garage
Frame - Steel
AHU1
13
22
8
11
249.3ft2
0 0.5
0
8
NW
Exterior
Concrete Block - Intlnsul
AHU1
4.1
52
11
572.0ft2
0 0.5
0
9
NE
Exterior
Concrete Block- Int Insul
AHU2
4.1
33
4
9
300.0 ft2
0 0.5
0
10
SE
Exterior
Concrete Block- Int Insul
AHU2
4.1
28
0
9
252.0 ft2
0 0.5
0
11
SW
Exterior
Concrete Block- Int Insul
AHU2
4.1
33
4
9
300.0 ft2
0 0.5
0
12
NW
Exterior
Concrete Block- Int Insul
AHU2
4.1
28
0
9
252.0 ft2
0 0.5
0
13
NW
Garage
Frame- Steel
AHU1
13
12
6
11
137.5 ft2
0 0.75
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
Ornt ID
Frame Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade Screening
1
NE 1
Metal Single (Clear)
Yes
0.94
0.36
Y
40.0 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
2
NE 2
Metal Single (Clear)
Yes
1.11
0.27
Y
64.0 ft2
9 ft 4 in
2 ft 0 in
Drapes/blinds
None
3
NE 2
Metal Single (Clear)
Yes
0.94
0.36
Y
40.0 ft2
9 ft 4 in
2 ft 0 in
Drapes/blinds
None
4
NE 2
Metal Single (Clear)
Yes
0.99
0.33
Y
5.3 ft2
9 ft 4 in
2 ft 0 in
Drapes/blinds
None
5
SE 3
Metal Single (Clear)
Yes
0.99
0.33
Y
5.3 ft2
4 ft 6 in
2 ft 0 in
Drapes/blinds
None
6
SE 4
Metal Single (Clear)
Yes
1.11
0.27
Y
48.0 ft2
14 ft 0 in
1 ft 0 in
Drapes/blinds
None
7
SE 4
Metal Single (Clear)
Yes
1.02
0.29
Y
37.3 ft2
14 ft 0 in
1 ft 0 in
Drapes/blinds
None
8
SW 5
Metal Single (Clear)
Yes
0.99
0.33
Y
13.3 ft2
6 ft 8 in
2 ft 0 in
Drapes/blinds
None
9
SW 6
Metal Single (Clear)
Yes
1.07
0.3
Y
20.0 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
10
SW 6
Metal Single (Clear)
Yes
1.07
0.3
Y
20.0 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
11
NW 8
Metal Single (Clear)
Yes
0.99
0.33
Y
13.3 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
12
NW 8
Metal Single (Clear)
Yes
1.07
0.3
Y
15.6 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
13
NW 8
Metal Single (Clear)
Yes
1.07
0.3
Y
15.6 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
14
NE 9
Metal Single (Clear)
Yes
1.07
0.33
Y
18.7 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
15
NE 9
Metal Single (Clear)
Yes
0.94
0.36
Y
40.0 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
16
SE 10
Metal Single (Clear)
Yes
0.99
0.33
Y
5.3 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
17
SE 10
Metal Single (Clear)
Yes
0.99
0.33
Y
5.3 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
18
SW 11
Metal Single (Clear)
Yes
0.99
0.33
Y
11.1 ft2
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
19
SW 11
Metal Single (Clear)
Yes
1.07
0.3
Y
18.7 f12
1 ft 6 in
2 ft 0 in
Drapes/blinds
None
5/17/2018 6:57 AM EnergyGauge@USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
GARAGE
#
FloorArea Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
440 ft2
440 ft2
44 ft 8 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
ProposedACH(50)
.000263
1673.1 91.85 172.74 .2427 4
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump/
Electric Heat Pump/
None
None
HSPF:11 50.5 kBtu/hr 1
HSPF:10.5 24.4 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
SEER: 16 46 kBtu/hr 1380 cfm 0.75 1
SEER: 16 24 kBtu/hr 720 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Heat Pump
AHU1
3.5 80 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # CompanyName
Collector Storage
System Model# CollectorModel# Area Volume
FEF
None
None
ftZ
DUCTS
V #
--- Supply --
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area LeakageType Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
AHU1 6 125 ft2
Attic 6 85 ft2
AHU1
Attic
40 ft2 Default Leakage Garage (Default) c(Default) c
30 ft2 Default Leakage Attic (Default) c(Default) c
1 1
2 2
5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Cooling Jan
Heat in Jan
Feb
Feb
Mar
Mar
A r
A r
Ma
Ma
Jun
Jun
Jul
Jul
Au
Au
Se
Se
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
X Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
5/17/2018 6:57 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5