Loading...
HomeMy WebLinkAboutRevisions; Insulation Changes & Truss Connector Schedule ChangesOFFICE USE ONLY: DATE FILED: . �5-- REVISION FEE: S - D 0 LOCATION/SITE ADDRESS: PERMIT # I v " y 03aq RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34992.5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REmm, PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT n�.�rrcrn�vc. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): 7 . -- FAX: OWNER/BUILDER INFORMATION: NAME: _ ADDRESS: CITY: PHONE (DA ARCHITECT/ENGINEER INFORMATION: NAME: ttY G�t� ADDRESS: .3. Uli S CITY: STATE: _ PHONE (DAYTIME):NT�?�s SLCCC: 9123109 Revised 06130117 F�!!eE , dig p Pe ps ePartment St. Lucie County, FL FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Powers Residence Builder Name: Street: 6418 Riverland Drive Permit Office: City, State, Zip: Port St. Lucie , FL , 34982 Permit Number: Owner: Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3514.8 sqft.) Insulation Area j' 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R= 5.0 3128.00 ft2 b. Frame - Steel, Adjacent R= 20.0 386.83 ft2 :3. Numberof units, if multiplefamily 1 c. N/A R= ft2 4. Numberof Bedrooms 3 d.N/A R= ft2 10. Ceiling Types (1627.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R= 20.0 1627.00 ft2 6. Conditioned floor area abovegrade (ft2) 2427 b. N/A R= ft2 Conditionedfloor area belowgrade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(436.9 sqft.) Description Area a. Sup: AHU1, Ret: AHU1, AH: Garage 6 125 a. U-Factor: Sgl, U=0.94 120.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 85 SHGC: SHGC=0.36 b. U-Factor: Sgl, U=1.11 112.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 46.0 SEER:19.0 b. Central Unit 24.0 SEER:19.0 c. U-Factor: Sgl, U=1.07 89.78 ft2 SHGC: SHGC=0.30 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 115.11 ft2 a. Electric Heat Pump 50.5 HSPF:11.00 SHGC: other (see details) b. Electric Heat Pump 24.4 HSPF:10.50 Area Weighted Average Overhang Depth: 6.096 ft. Area Weighted Average SHGC: 0.313 14. Hot watersystems a. Electric Cap: 80 gallonsEF:3.500 8. Floor Types (2427.0 sqft.) Insulation Area a. Slab -On -Grade Edge Insulation R=0.1 2427.00 ft2 b. Conservationfeatures 4 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat ••••••••• '' P'••• CM •••R al Proposed Modified Loads: 60.17 Glass/Floo ,' C ' •'�� P PASS �'l Total Baseline Loads: 81.16 �•4 I hereby c t the plans and specifiati covere ' Review of the plans and'i�s•q?, this calcula e in c with da El r specifications covered by this Code. •1j C�tr� calculation indicates compliance r�,, '' �,.�` t •�+ �O ••"� with the Florida Energy Code. !%Irr"'u=:r" ::•��'`�ti, PREPARED " DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. �. with the Florida Energy Code. OWNER/AGENT: BUILDING O FI I L: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that t a ndlte n u Vf,certified factory -sealed in accordance with R403.3.2.1.- Compliance requires an Air Barrier and Insulation Inspection Checklist in acc d th 4 1 project requires an envelope leakage test report with envelope leakage no greater than 4.00 ACH50 (R402.4.1.2). Flle Copy 9/21 /18 9.44 AM EnergyGaugeOUSA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R40&2017 PROJECT Title: Powers Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2427 Lot# Owner Name: Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6418 Riverland Drive Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, 34982 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1627 17897 2 Block2 800 7200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AHU1 1627 17897 Yes 2 1 1 Yes Yes Yes 2 AHU2 800 7200 No 2 2 1 Yes Yes Yes FLOORS # FloorType Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation AHU1 194 ft 0.1 1627 ft2 0 0 1 2 Slab -On -Grade Edge Insulation AHU2 119 ft 0.1 800 ft2 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal Roof 1762 ft2 338 ft2 Medium 0.75 No 0.9 No 20 22.6 ATTIC t/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1627 ft2 N N 9/21/18 9.44 AM EnergyGauge®USA - FlaRes2017Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) AHU1 20 Open Cell Foam 827 ftZ 0.11 Wood 2 Under Attic (Unvented) AHU2 20 Open Cell Foam 800 ftZ 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below n�nt To Wall Type Space R value Ft In Ft In Area R Value E-fi�n Ah 1 NE Exterior Concrete Block - Int Insul AHU1 5.0 22 8 11 249.3 ftZ 0 0.5 0 2 NE Exterior Concrete Block - Int Insul AHU1 5.0 32 8 11 359.3 ft2 0 0.5 0 3 SE Exterior Concrete Block - Int Insul AHU1 5.0 28 0 11 308.0 ftZ 0 0.5 0 4 SE Exterior Concrete Block - Int Insul AHU1 5.0 16 0 11 176.0 ftZ 0 0.5 0 5 SW Exterior Concrete Block - Intlnsul AHU1 5.0 14 0 11 154.0ft2 0 0.5 0 6 SW Exterior Concrete Block - Int Insul AHU1 5.0 18 8 11 205.3 ftZ 0 0.5 0 7 SW Garage Frame - Steel AHU1 19 22 8 11 249.3ft2 0 0.5 0 8 NW Exterior Concrete Block - Int Insul AHU1 5.0 52 11 572.0 ftZ 0 0.5 0 9 NE Exterior Concrete Block - Int Insul AHU2 5.0 33 4 9 300.0 ftZ 0 0.5 0 10 SE Exterior Concrete Block - Int Insul AHU2 5.0 28 0 9 252.0 ftZ 0 0.5 0 11 SW Exterior Concrete Block - Int Insul AHU2 5.0 33 4 9 300.0 ftZ 0 0.5 0 12 NW Exterior Concrete Block - Int Insul AHU2 5.0 28 0 19 252.0 ftZ 0 0.5 0 13 NW Garage Frame - Steel AHU1 19 12 6 11 137.5 ftZ 0 0.75 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Single (Clear) Yes 0.94 0.36 Y 40.0 ft' 1 ft 6 in 2 ft 0 in Drapes/blinds None 2 NE 2 Metal Single (Clear) Yes 1.11 0.27 Y 64.0 ftZ 9 ft 4 in 2 ft 0 in Drapes/blinds None 3 NE 2 Metal Single (Clear) Yes 0.94 0.36 Y 40.0 ft' 9 ft 4 in 2 ft 0 in Drapes/blinds None 4 NE 2 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ft' 9 ft 4 in 2 ft 0 in Drapes/blinds None 5 SE 3 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ftZ 4 ft 6 in 2 ft 0 in Drapes/blinds None 6 SE 4 Metal Single (Clear) Yes 1.11 0.27 Y 48.0 ftZ 14 ft 0 in 1 ft 0 in Drapes/blinds None 7 SE 4 Metal Single (Clear) Yes 1.02 0.29 Y 37.3 ftZ 14 ft 0 in 1 ft 0 in Drapes/blinds None 8 SW 5 Metal Single (Clear) Yes 0.99 0.33 Y 13.3 ftZ 6 ft 8 in 2 ft 0 in Drapes/blinds None 9 SW 6 Metal Single (Clear) Yes 1.07 0.3 Y 20.0 ft' 1 ft 6 in 2 ft 0 in Drapes/blinds None 10 SW 6 Metal Single (Clear) Yes 1.07 0.3 Y 20.0 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 11 NW 8 Metal Single (Clear) Yes 0.99 0.33 Y 13.3 ft' 1 ft 6 in 2 ft 0 in Drapes/blinds None 12 NW 8 Metal Single (Clear) Yes 1.07 0.3 Y 15.6 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 13 NW 8 Metal Single (Clear) Yes 1.07 0.3 Y 15.6 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 14 NE 9 Metal Single (Clear) Yes 1.07 0.33 Y 18.7 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 15 NE 9 Metal Single (Clear) Yes 0.94 0.36 Y 40.0 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 16 SE 10 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 17 SE 10 Metal Single (Clear) Yes 0.99 0.33 Y 5.3 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 18 SW 11 Metal Single (Clear) Yes 0.99 0.33 Y 11.1 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 19 SW 11 Metal Single (Clear) Yes 1.07 0.3 Y 18.7 ftZ 1 ft 6 in 2 ft 0 in Drapes/blinds None 9/21/18 9.44 AM EnergyGauge®USA - FlaRes2017Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 44 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000263 1673.1 91.85 172.74 .2427 4 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump/ Electric Heat Pump/ None None HSPF:11 50.5 kBtu/hr 1 HSPF:10.5 24.4 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER:19.0 46 kBtu/hr 1380 cfm 0.75 1 SEER:19.0 24 kBtu/hr 720 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump AHU1 3.5 80 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area LeakageType Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 AHU1 6 125 ft2 Attic 6 85 ft2 AHU1 Attic 40 ft2 Default Leakage Garage (Default) c(Default) c 30 ft2 Default Leakage Attic (Default) c(Default) c 1 1 2 2 9/21/18 9.44 AM EnergyGauge®USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM, R405-2017 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Coolin Jan Heating H Jan Feb H Feb [ Mar N Mar Apr f Apr f Ma I May Jun Jun ri X Jul Jul X Aug f Aug 4 Se SeP Oct Oct Nov XNov Dec XDec Ventin Jan Feb X Mar [Xj A r [ Ma Jun [ Jul [ Au [ Se [ Oct [X Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/21/18 9.44 AM EnergyGauge®USA - FlaRes2017Section R405.4.1 Compliant Software Page 5 of 5 0 N 33,-4„ 5,_4„ 4,_0" 5'-4 10'-0" EGRESS 2:6> <2.5 2. 0 N 12'-11" 5' 14,_7, BONUS N N BED 3 203 ROOM 202 co 42" LOW WALL EL. 1 l'-4" T.O. PLYWOOD = u> ^Tr T.O. TREAD ELEV @ 9'-6 a' o 0 N do 2.3CGS o N 0 9 N N "LO 8 2 41_411 3,_4„ Fmlffimmm ftj 4 _ u r' TOFF 7 --ATTIC ACCESS 204 < (REFER TO DETAIL) HALLWAY BED 2 M o/4„ BATH 3 1 67/ 77/ 205 9,_9„ 51. 3,_0„ 5„ 201 14,_11co � 2.1 2.2 OEGRESS ° - NOTES 3,_4„ 9,-4„ 33,_4„ 1. ALL FURNISHING & CABINETRY TO BE SUPPLIED BY OWNER 2. ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO START OF CONSTRUCTION, ANY DISCREPANCIES ARE TO BE DISCUSSED WITH ARCHITECT 3. WALLS ARE TO RECEIVE A LEVEL 4 FINISH & READY FOR PAINT (COLOR BY OWNER) 4. INSULATION TO BE INSTALLED AS F-0.LLOW&.- 2 - EXTERIOR WALLS MIN. R5.1 MIN. R30 ROOF TRUSS RAFTERS ATTIC CEILING $ MIN.> 5. F.F. ELEVATION REPRESENTS T.O. CONC. SLAB, COORD. w/OWNER ON ALL FINISHES `6. REFER TO KITCHEN DWGS FOR LAYOUT SPECIFICS 7. REQUIRED EGRESS OPENINGS ARE LOCATED AS SHOWN PER FBC R310 8. ALL EXTERIOR WINDOW AND DOORS OPENINGS ARE TO BE HURRICANE IMPACT RATED, REFER TO NOA OR PRODUCT APPROVAL FOR MORE SPECIFICS 9. REFER TO ELECTRICAL PLAN FOR REQUIRED SMOKE AND CO2 DETECTOR LOCATIONS 10. ALL INTERIOR DOORS ARE TO BE INSTALLED A MIN. OF 4" OFF OF ADJACENT WALL TO ALLOW FOR WOOD MOLDING. 11. BUILDING INSULATION TO BE INSTALLED AS FOLLOWS: �Q EXTERIOR MASONRY WALLS: a' RIGID FOAM BOARD R-4.1 S TERIOR WALLS wAn A/C SPACES: UNFACED R-11 BATT ROOF TRUSSES (TOP CHORD): 5.5" OPEN CELL FOAM R-20 CLASSIC MAX TT WALL BETWEEN GARAGE & MASTER BATH: 5.5" OPEN CELL FOAM R-20 CLASSIC MAX TT 12. WALL & CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX OF NOT GREATER THAN 200 & A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450 CONTRACTOR TO VERIFY ALL FINISH MATERIALS INSTALLED ARE CATEGORIZED WITHIN THIS REQ'D INDEX 13. INSULATION MATERIALS, INCLUDING FACINGS; SUCH AS VAPOR RETARDERS AND VAPOR -PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL ,HAVE AFLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450. CONTRACTOR TO VERIFY ALL FINISH MATERIALS INSTALLED ARE CATEGORIZED WITHIN THIS REQ'D INDEX 14. ELECTRICAL SYSTEMS, EQUIPMENT AND COMPONENTS; HEATING, VENTILATING, AIR CONDITIONING; PLUMBING APPLIANCES & FIXTURES; DUCT SYSTEMS; AND OTHER SERVICE EQUIPMENT SHALL BE LOCATED AT 12" ABOVE THE BASE FLOOD ELEVATION ALL EQUIPMENT TO BE MOUNTED ON ALUM. STAND IF EQUIPMENT PAD NOT LOCATED 12'. ABOVE BASE FLOOD ELEVATION; REFER TO NOA FOR SPECIFICS. GENERAL NOTES FOR ALL PARTITIONS 1. TILE BACKER BOARD OR DUROCK IS TO BE USED AT ALL WET WALL TILE APPLICATIONS, METAL STUDS SHALL BE 20 GAUGE & 16" O.C. 2. STUD GAUGE SHALL BE AS SPECIFIED, EXCEPT AT BATHROOMS & KITCHENS A MIN. 20 GAUGE @ 16" O.C. SHALL BE USED WHERE CABINETS OR PLUMBING FIXTURES ARE HUNG. 3. PROPER BRACING OF STUDS SHALL BE THE RESPONSIBILITY OF THE SUB -CONTRACTOR INSTALLING THEM. 4. FASTEN METAL TRACK TO CONCRETE SLAB W/ POWDER ACTUATED FASTENERS @ 24" O.C. TOP AND BOTTOM 5. CONTRACTOR TO VERIFY STUD GAUGE BASED ON FLOOR TO FLOOR HEIGHT. 6. PROVIDE 1" DEFLECTION HEAD AS REQUIRED 7. ALL PERIMETER DRYWALL SEAMS, CONSTRUCTION JOINTS AND WALL PENETRATIONS ARE TO BE SEALED WITH TAPE, FOAM AND/OR CAULK TO FORM AN AIRTIGHT SEAL. 8. GYP WALLBOARD TO BE ATTACHED w/ MIN. 1-5/8" DRYWALL SCREWS AT MIN. 16" SPACING. CEILINGS ATTACHED AT 12"SPACING (PER NATIONAL GYP ASSOC. STANDARDS) 9. ALL INTERIOR, NON -PLUMBING, WALLS ARE 3-5/8" METAL STUD w/ 5/8"`DRYWALL U.O.N. F 00 N 1.7 Y O MASTER 3 59'-10" A301', Sim. 6,_4„ 12,_8„ 1.2,_8„ 11'-101, N BACK PORCH 12" MASONRY COLUMN (TYP.) 1.4 w w I EGRESS�7 O I I o o J 1 m N T.O. CONC. SLAB v ° 3.4 8-0 2-8 10-0 5-4 2-0 1-4 SUITE 107 1.9 1.3 1.6 "■ 4,_0„ y_6„ 8,_6„ 4'-1 DINING REFER TO A502 mgmmm_- TL ' FOR STAIR P 3,_6„ CU-1 C BATH 1 o 108 N m 1.10 ih 4,_0„ ° M6 PLUM G WALL 2 N D FLOOR 5,_3„ 8,_5„ 3,_011 1 " 1/4" = 1' A3o1 M 1.5 j _4 4„ II / O C L -\ J ATTIC ACCESS (REFER TO DETAIL) FPLMETER &' DISCONNECT - GARAGE .. � , 109 1 W 0 WATER TREATMENT N EQUIPMENT io 0 EL. - 0'-8" AFF T.O. GARAGE SLAB HRH 6" CONC SLAB (GARAGE ONLY) LEGEND 8" CMU WALL W/ 8" HAT CHANNEL OR 1x P.T. WOOD FURRING STRIPS @ 16" O.C. & 5" GYP BOARD, U.O.N. 0 3 e" METAL STUD WALL @ 16" O.C. w/ g' DRYWALL WALL INSULATION (REFER TO NOTES) PLUMBING WALLS TO HAVE 6" EQUIVALENT @ 16" O.C. h E) ERIOR DOOR SCHE LIVING 105 S EQIFIcs 106 EL. 0'-0" (8.0' NAVD 88) T.O. CONC. SLAB i o0 PAN RY 6'-3" " T-10" „ 6'-11" 6'-9" T-01/2" rRANSE_e ; BLIdVE mmmmmmm ---- - 01# H06D o a - D O 4.10 LAUNDRY KITCHEN 6„ 104 103 811 HALLWA 110[7 L STDA Lr D DWDGE L. J p - - - - co 1 "RECESS x 8" WIDE 6 L3,_4„ 16-0„ 3-411 22,_8„ Db R NUMBER SIZE s REMARKS MARK F wCL w NOA! Q" w FL:PRODUCT ¢ U_ APPROVAL GROUND FLOOR 1.1 - ENTRY 4'-8" 8'-0" FIBERGLAS SWING WOOD TBD THERMA-TRU / GLASS T DOOR w/ SIDELITE 1.2 - NOT`USED 1.3-LIVING 8'-0" 8'-0" ALUM/Gl SLIDING ALUM 17-0420.12 PGT 2 PANEL SGD 1.4-BED';f 6'-0" V-0" ALUM/GL SWING ALUM 17-0504.01 PGT DOUBLE FRENCH DOOR 1.5 - GARAGE (MAN) 3'-4" T-4" HM FLUSH HM TBD 4" CONC CURB & DOOR SWEEP 1.6 -GARAGE 16'-0" 8'-0" STEEL GARAGE TRACK TBD CIOPAY WINGUARD * ALL MISSING NOAs TO BE SUBMITTED FOR APPROVAL PRIG TO INSPECTION ROOM SCHEDULE N 1.4 to SLOPE_ II 1 o ;o N If ( SLOPE_ I4 3 A301 SIM. BATH 2 4, 1:3 6'-B" FOYER .1 EL -0'-4" 3'-4' 00 4". T.O. CONC. SLAB 102 OL SO A< , 1.2 v 12" MASONRY COLUMN O O (TYP.)', Iddh 3-4 3-4 6-0 3-4 Z-81. 2 ALL MANUFA6fiURE HGC C S SHOWING 14'-0 4'-6" A301 U FACTORS AND SHGC COMPLIANCE WITH FBC ENERGY CODE MUST WS PLANS AND ALL WOpK REMAIN ON ALLDOORSOAND WINDOWS OVED ARE SUBJECT TO ANY C iffp{gf 3 GROUND FLOOR I -INSPECT( REQUIRED BY FIELD INSP 3 THAT UNTIL MAY BE NECESSARY IN ORDER TO 1 /4n q .� � J COMPLY WITH ALL APPLICA®LG 000E3. CONCEALEOFASTENERS ORAI7 SCHEDULE + ARE THE RESpMSlBlUlpOF Ti ENTS WINDOW S C H E D U L E CONTRAMROFRECORD ROOM NUMBER FLOOR BASE WALL CEILING 101 - FOYER BY OWNER WOOD %° GYP. y2" GYP. 102 - BATH 2 TILE TILE %s'' GYP. Y2" GYP. 103 - KITCHEN BY OWNER WOOD %" GYP:- Y2" GYP. 104 - LAUNDRY TILE WOOD e' GYP. )2" GYP. 105 - DINING BY OWNER WOOD %" GYP. )2" GYP. 106 - LIVING BY OWNER WOOD s/e" GYP. Y2" GYP. 107 - MASTER SUITE BY OWNER WOOD 5/e" GYP. )2" GYP. 108 - BATH 1 TILE WOOD s/a" GYP, : Y2" GYP. 109 - GARAGE SEALED CONC. VINYL GYP. %" GYP. 110 - HALLWAY BY OWNER WOOD s/a" GYP. )2" GYP. 201 -BED 2 BY OWNER WOOD s/a" GYP. Y2" GYP. 202 - BONUS ROOM BY OWNER WOOD 5/e" GYP. Y2" GYP. 203 - BED 3 BY OWNER WOOD 6/8" GYP. Y2" GYP. 204 - STORAGE BY OWNER WOOD 6/s" GYP. 1/2" GYP 205 - BATH 3 TILE TILE his' GYP. Y2" GYP. SIZE TYPE REMARKS MARK 11 ROUGH OPENING WIDTH HEIGHT NOA / FLPRODUCT APPROVAL 1.1 3'-4" 6-0" SINGLE HUNG 17-0630.08 1.2 3'-4" 6-0" SINGLE HUNG 17-0630.08 ST. UCIE COLNTY BL7LD _�G DrVr[SIO 1.3 T-4" 4'-0" FIXED 17-0614.11 REVIEWED FOR IE 1.4 2'-0" 2'-8" FIXED 17-0614.11 DATE / 'G'ACo INSFYCTION WILL BE MADE. 1.5 2'-0" 2 -8" FIXED 17-0614.11 1.6 10'-0" 4'-0" STOREFRONT 17-1114.02 1.7 10'-0" 4'-0" STOREFRONT 17-1114.02 1.8 3'-4" 4'-8" SINGLE HUNG 17-0630.08 1.9 3'-4" 4'-8" SINGLE HUNG 17-0630.08 1.10 T-4' 4'-0" FIXED 17-0614.11 2.1 3'-4" 3'-4" FIXED 17-0614.11 2.2 4'-0" 4'-8" SINGLE HUNG 17-0630.08 2.3 2'-0" 2'-8" FIXED 17-0614.11 2.4 2'-0" 2'-8" FIXED 17-0614.11 2.5 10'-01, 4'-0" STOREFRONT 17-1114.02 2.6 4'-0" 4'-8" SINGLE HUNG 17-0630.08 NOTE: ALL EXTERIOR WINDOWS & DOORS ARE TO BE INSTALLED AS SHOWN IN THE APPROVED NOA or FL. PRODUCT APPROVAL. ISSUE: DATE: SUBMITTAL 03/28/18 REV(,#1 REV(#2COORDINATION CITY COMMENTS I 05/21/18 08/27/18 ott archer studio (stainable Architecture Interiors Planning Consulting 412 SW 14th Street Lauderdale, Florida 33315 Phone 954 215.4361 J U_ W U J F to w O d W U 'z W ( w Il � 0 W 3 O I.i. LU r 4 � p - 0 w <n, LU (n U yy 0 O File (TYP) T . BB2 F 2 1 2 1 Q- N N m RIDGE I N C7 0 F-ILL a 0 0 0 O / W LLI \ z =Cq Ly Q_ w Co T 0. B62 20'-8" O Co UPPER ROOF FRAMING PLAN 1 /A" — q' GENERAL NOTES 1. 2. ALL LUMBER USED FOR ROOF & WALL FRAMING SHALL BE SOUTHERN PINE No 2 OR BETTER. LUMBER BOARDS USED, FOR ROOF SHEATHING SHALL BE IN ACCORDANCE W/TABLE R4409.2.';. ::: ,. ROOF SHEATHING NOTES 1. 2. 3. %" EXTERIOR GRADE PLYWOOD. PERIMETER NAILED w/ 10d NAILS @ 4" O.C. FIELD NAILED w/ 10d NAILS @ 6" O.C. BEAM SCHEDULE x w MARK SIZE REINFORCING REMARKS BB1 8" x 8" MIN. (1) #5 MASONRY BOND BEAM BB2 8" x 16" MIN. (1) #5 BOTTOM MASONRY BOND BEAM, CONT. @ PERIMETER OF HOUSE (1) #5 TOP MASONRY BOND BEAM, CONT. @ PERIMETER WHERE BB3 B" x 24" MIN. (1) #5 MID & FLOOR TRUSSES ATTACH TO MASONRY WALL (1) #5 BOTTOM TB1 8" x 24" MIN. (2) #5 TOP (2) #5 MID CONCRETE TIE BEAM (2) #5 BOTTOM #3 STIRRUPS @ 10"O.C. MAX. AND OVER OPENINGS ADDITIONAL (2) # 5'S REQUIRED AT TOP WHEN GOES TB2 8" x 16" MIN. (1) #5 TOP & OVER COL (32"MIN OVER LAP) (1) #5 BOTTOM FB1 (2) 2x WE) BEAM w/ (2) 1/2" PLY .SEE NOTES BELOW TBD, PER ARCHITECT'S REVIEW OF FLR TRUSS SMOPS & ENGIN. 8" x LENGTH LOTT'S PRECAST CONC. LINTEL w/ MIN. 6" BEARING SHOWN (1) #5 REFER TO NOA FOR SPECIFICS FLITCH BEAM NOTES: 2x FLITCH BEAMS AT STAIR TO HAVE 1/2" PLYWOOD SHEATHING BETWEEN EACH BOARD, TYP OF 2 LAYERS @ EACH BEAM. (1) 5/8" THRU BOLT @ 16" O.C., STAGGERED. COORD. w/ TRUSS LOCATIONS NOTES 1. PROVIDE MOISTURE BARRIER BELOW ALL TRUSS SEATS. 2. ALL TRUSS ARE TO BE DOUBLE STRAPPED AT EACH CONNECTION. 3. FLITCH BEAM: 2x FLITCH BEAMS @ STAIR TO HAVE 1/2" PLYWOOD SHEATHING BETWEEN EACH BOARD, TYP OF 2 LAYERS @ EACH BEAM. (1) 5/8" THRU BOLT @ 16" STAGGERED., COORD. w/ TRUSS LOCATIONS. 4. (2) 2x WOOD LEDGER ATTACHED w/ 5/8" ANCHOR OR THRU BOLT @ 16" O.C. WOOD AGAINST CONIC. TO BE P.T. WIND DESIGN ASCE 7 -10 Risk Category II Directionality (Kd) 0.85 Mean Roof Ht (h) 35 Design Wind Speed (mph) 170 Parapet ht above grd 0 Exposure Category ' C Enclosure Classif. Enclosed Building Internal pressure 0.18 a = 4.4 ft Roof Angle 18.43 deg Type of roof Hip HIP ROOF (ENCLOSED) HIP ROOF (PART -ENCLOSED) ZONE 1 +28.5 +44.0 - 45.2 - 60.7 ZONE2 +28.5 +44.0 - 78.7 - 94.2 ZONE 3 + 28.5 +44.0 - 78.7 94.2 v M (TYP) P ADDIT BB1 Ca 8'-8" \e � 1 GIRDER H w W V' bD PRE-ENGINEERED ROOF U J bo TRUSSES 24" O.C. MAX. (TYP. x. H: z II Q V — Y U / GIRDER \ k� N m 1- h M M N. 03 m o H H J q i > ISSUE: DATE SUBMITTAL 03/28/18 REV#1 CITY COMMENTS 05/21/18 REV#2 COORDINATION 08/27/18 i RECEIVED SEP 052018 87. Lucie C®ury, i ti"i Pemlitring �I' I i i Scott archer studio Sustainable Architecture Interiors Planning Consulting 412 SW 14th Street 11L Lauderdale, Florida 33315 Phone 954.235.4361 J LL I L U J H I I O W LOWER ROOF FRAMING PLAN FLOOR & LOWER ROOF FRAMING PLAN 1/4' = 1' 1/4" = 1' w 0 CONNECTOR SCHEDULE I w2z 3 2 3' 1 ROOF TRUSS 3 2 3 ROOF GIRDER 1 2 FLR JOIST 2 1 2 1 2 2 PATIO 2 1 2 2 1 TRUSS 2 2 1 GARAGE TRUSS @ SIDE WALL 3 2 3 STAIR 1 BEAM CMU 2 2 NO. SIMPSON ALLOWABLE FASTENERS REMARKS CONNECTOR LOADS CONCRETE TRUSS META24 1450 LB. 6 -16d WOOD TO CONCRETE EMBEDED CONCRETE TRUSS META24- 1450 LB. 6 -16d WOOD TO CONCRETE EMBEDED MTS16 1000 LB. 14 - 10d WOOD TO WOOD 44 MTS24 1000 LB. 14 - 10d WOOD TO WOOD HUS28 2000 LB. 8-16d WOOD TO WOOD THA426 1150 LB. ii30 - 16d WOOD TO WOOD I O ' I I Z Q w U w Q U) i Q tx J 03 2 2 3 o N ZL L 3 1 3 m-,