HomeMy WebLinkAboutProduct Approval 7 1/11/2021 Florida Building Code Online
BCIS Home Log In i User Registration i Hot Topics Submit Surcharge Stats&Facts ! Publications Contact Us aCIS Site Map I Links Search
Florida
a,�,,
�aProduct Approval
USER:Public User
6^,m
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL15279-R6 �
Application Type Revision Is�'
Code Version2020
Application Status Approved ���
*Approved by DBPR.Approvai's byPITEh�'IUh e;e l-atified by
the POC and/or the Corti sr f1EecgsgaMPL'ANCE
Comments ST. LUCIE COUNTY
Archived BOCc
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason,OH 45040
(513)770-6062
mwesterrield@clopay.com
Authorized Signature Scott Hamilton
shamilton@clopay.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative File Coj)v
Address/Phone/Email --- ��.:..�•_-�
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency Intertek Testing Services NA,Inc.
Validated By Gary Pfuehler
3 Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2005
ANSI/DASMA 115 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15279 R6 Equiv 20200812-FBC-ASTM 1886-1996 equiv.pdf
FL15279 R6 Equiv 20200812-FBC-DASMA 108 ASTM E330 equlv.pdf
Product Approval Method Method 1 Option A
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgy3yVVKJZ1QRAbbA5BZkl91cB666W7gbTBzl4gLt8JfFw%3d%3d 1/6
1/11/2021 Florida Building Code Online
' Date Submitted 12/11/2020
Date Validated 12/29/2020
Date Pending FBC Approval
Date Approved 12/29/2020
Summary of Products
Go to Page Page 5/8 0 0
FL# Model,Number or Name Description
15279.81 081 W6-09 DSIU-1F171: 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.; interior
9201,9203,HDP20, HDPF20, skin 27 ga. min.)Single-Car(up to TO"wide)WINDCODE@
HDPL20,7200,7201,7203,8200, W6 Garage Door
8201,8203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FLIS279 R6 II 104184-B-RevOS.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.82 082 W6-09 DSIUO-1K479: Canyon Double Skin Insulated PUR(exterior skin 27 ga.min.; interior
Ridge/Brookstone skin 27ga. min.)with Overlay Single-Car(up to 9'0"wide)
WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R6 II 104265-A-RevO3.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.83 083 W6-09 DSIUO-IK479: Canyon Double Skin Insulated PUR(exterior skin 27 ga. min.; interior
Ridge/Brookstone skin 27ga. min.)with Overlay Single-Car(up to 9'0"wide)
WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R6 II 104265-B-Rev03.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.84 084 W6-09 PAN-2F153: 73,75,84A, Steel Pan (min. 25 ga.)Single-Car(up to 9'0"wide)
- 94,42,48,42B,48B,4RST,6RST, WINDCODE@ W6 Garage Door with Optional Impact-Resistant
GD5S,GRSS,ARSS,EDSS Lites
Limits of Use Certification Agency Certificate'
Approved for use in HVHZ: No FLIS279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FLIS279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other: Solid doors(no standard glazing)or doors with 05/21/2028
optional impact-resistant standard glazing are impact-resistant Installation Instructions
(large missile impact). FLIS279 R6 II 101348-A-Revl9.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.85 085 W6-09 PAN-2F153: 73,75,84A, Steel Pan (min. 25 ga.)Single-Car(up to 9'0"wide)
hfps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZki9lcB666W7gbTBz[4gLtBJfFw%3d%3d 2/6
1/11/2021 Florida Building Code Online
94,42,48,42B,48B,4RST,611ST, WINDCODEO W6 Garage Door
GD5S,GRSS,ARMS,ED5S
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FLIS279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R6 1I 101348-B-Rev19.pdf
regions. Verified By: Intertek•Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports i
Created by Independent Third Party:
15279.86 086 W6-09 PAN-217443: G4S,GS4, Gallery/Artistry/Expressions: Steel Pan (min.24 ga.)Single-
GD4S,GR4S,G4SV,GS4V,GD4SV, Car(up to 9'0"wide)WINDCODE@ W6 Garage Door
GR4SV,E4S;ED4S,E4SV,ED4SV,
SS4,AR4S,SS4V,AR4SV
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FLIS279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf-
Impact Resistant:Yes FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R6 11 103488-A-Rev09.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.87 087 W6-09 PAN-2F443: G4S,GS4, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)Single-
GD4S,GR4S,:G4SV,GS4V,GD4SV, Car(up to 9W wide).WINDCODE@ W6 Garage Door
GR4SV,E4S,ED4S,E4SV, ED4SV,
SS4,AR4S,SS4V,AR4SV
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FLIS279 R6 II 103488-B-Rev09.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.88 088 W6-09 PAN-217446: G4L,GL4, Gallery/Artistry/Expressions:Steel Pan (min. 24 ga.)Single-
GD4L,GR4L,G4LV,GL4V,GD4LV, Car(up to 9'0"wide)WINDCODE@ W6 Garage Door
GR4LV, E4L,'ED4L,E41_V,ED4LV,SL4,
AR4L,SL4V,AR4LV
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions I
meet the impact resistant requirement for windborne debris FL15279 R6 I1 103488-B-Rev09.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.89 089 W6-09 PAN-217446: G4L,GL4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.).Single-
GD4L,GR4L,G41_V,GL4V,GD4LV, Car(up to 9'0"wide)WINDCODE@ W6 Garage Door
GR4LV,E4L, ED4L,E4LV,ED4LV,SL4,
AR4L,SL4V,AR4LV
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R6 II 103488-A-Rev09.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
hfps://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv3yWKJZl QRAbbA5BZkl9l cB666W7gbTBzl4gLt8JfFw%3d%3d 3/6
1/11/2021 Florida Building Code Online
Evaluation Reports
Created by Independent Third Party:
15279.90 090 W6-09 SPO-217449: Grand Steel Pan(min.24 ga.)with Overlay Single-Car(up to 9'0"
Harbor,Stone Manor wide)WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R6 II 103554-B-RevO9.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.91 091 W6-09 S130-217499: Grand Steel Pan(min. 24 ga.)with Overlay Single-Car(up to 9'0"
Harbor,Stone Manor wide)WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FLi5279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FLi5279 R6 II 103554-A-RevO9.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.92 092 W6-09 W-1G899: Custom Custom Wood Single-Car(up to 9'0"wide)WINDCODE@ W6
Reserve Collection CRD,CR800 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FLi5279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: N/A FLi5279 R6 C CAC W6 Listing Intertek.pdf i
Design Pressure: +39 PSF/-45 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FLi5279 R6 II 102833-RevOS.pdf
regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.2 FBC). Evaluation Reports
Created by Independent Third Party:
15279.93 093 W6-16 DSIE-1F171:4300, 2"Double-skin Insulated EPS(exterior skin 27 ga. min.;
4301,4310,4400,4401,HDG, interior skin 27 ga.min.) Double-Car(9'2"to 16'2"wide)
HDGL,HDGF,66,66G,67,67G,68, WINDCODE@ W6 Garage Door
SP200,SF200,SE200,6200,6201,
6203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listina Intertek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FLi5279 R6 II 101486-B-Revl7.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.94 094 W6-16 DSIE-1F171: 4300, 2"Double-skin Insulated EPS(exterior skin 27 ga. min.;
4301,4310,4400,4401,HDG, interior skin 27 ga. min.) Double-Car(97'to 16'2"wide)
HDGL, HDGF,66,66G,67,67G,68, WINDCODE&W6 Garage Door with Optional Impact-Resistant !�
SP200,SF200,SE200,6200,6201, Lites
6203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 R6 C CAC W6 Listing Intgrtek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)or doors with 05/21/2028
optional impact-resistant standard glazing are impact-resistant Installation Instructions
(large missile impact). FL15279 R6 II 101486-A-Rev17.pdf
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yWKJZIQRAbbA5BZkl9lcB666W7gbTBzl4gLt8JfFw°/"3d%3d 4/6
1/11/2021 Florida Building Code Online
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.95 095 W6-16 DSIE-iF471: GD2SP, Gallery/Artistry/Expressions: 2"Double-skin Insulated EPS
GR2SP,GD2LP,GR2LP,AR2SP,AR21-P, (exterior skin 27 ga. min.; interior skin 27 ga.min.)Double-
ED2SP,ED21-P Car(9'2"up to 16'2"wide)WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:-No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FLIS279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R6 II 104009-A-Rev03.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.96 096 W6-16 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2"Double-skin Insulated EPS
GR2SP,GD2LP,GR2LP,AR2SP,AR2LP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-
ED2SP,ED21LP Car(9'2"up to 16'2"wide)WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 rC CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FLIS279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R6 II 104009-B-Rev03.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.97 097 W6-16 DSIEO-1M479: Double Skin Insulated EPS(exterior skin 27 ga. min.; interior
Coachman/Settlers/Affinity skin 27ga. min.)with Overlay Double-Car(9'2"to 16'2"wide)
WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R6 II 103243-Rev12.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.98 098 W6-16 DSIU-IF171: 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.; interior
9201,9203, HDP20, HDPF20, skin 27 ga. min.)Double-Car(97'to 167'wide) WINDCODEQ
HDPL20,7200,7201,7203,8200, W6 Garage Door with Optional Impact-Resistant Lites
8201,8203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspgction.pdf
Impact Resistant:Yes FLIS279 R6 C CAC W6 Listino Intertek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)or doors with 05/21/2028
optional impact-resistant standard glazing are impact-resistant Installation Instructions
(large missile impact). FL15279 R6 II 104234-A-Rev02.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Parry:
Evaluation Reports
Created by Independent Third Party:
15279.99 099 W6-16 DSIU-1F171: 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.; interior
9201,9203, HDP20,HDPF20, skin 27 ga. min.)Double-Car(9'2"to 167'wide)WINDCODEQ
HDPL20,7200,7201,7203,8200, W6 Garage Door
8201,8203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date
hfps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI QRAbbA5BZkl9l cB666W7gbTBzl4gLt8JfFw°/"3d%3d .5/6
1/11/2021 Florida Building Code.Online
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris F1_15279 R6 II 104234-B-Rev02.pdf
regions. Verified By:Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.100 100 W6-16 DSIUO-1K479: Canyon Double Skin Insulated PUR(exterior skin 27 ga.min.; interior
Ridge/Brookstone skin 27ga. min.)with Overlay Double-Car(9'2"to 16'2"wide)
WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R6 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes F1_15279 R6 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R6 II 104266-Rev03.pdf
Verified By:Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:.
Go to Page Vir Page 5/8
Back Nsxt
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Cogyriyht 2007-2013 State of Florida.::Privaw Statement::Accessibillty Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an'emall address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® M M
Credit Card
Safe _
hftps://floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgv3yWKJZIQRAbbA5BZkl9lcB666W7gbTBzf4gLt8JfFw%3d%3d 6/6
s Intertek Testing Services NA,Inc. Tel+1-608-836-4400
uitertek Mid Murphy Drive Fax+1-608-ek.com 9
Middleton,WI 52562 www.intettek.com
Total Quality.Assured.
Issue Date: December 10,2020 Letter Report No: 104527767M I D-001a
Mr.Scott Hamilton, P.E.
Clopay Building Products Company Email:shamilton@clopay.com
8585 Duke boulevard
Mason, OH 45040
Subiect: Intertek Listings that support FL15279 for compliance with the Seventh Edition of the Florida Building
Code (2020)
Dear Mr. Hamilton,
This letter represents the results of Intertek's review of the Intertek Listings that currently support Clopay
Florida Product Approval FL15279.
Intertek affirms that the Intertek Listed products included in Florida Product Approval FL 15279 maintain
compliance with ASTM E330-14,ASTM E1886-13a, and ASTM E1996-17 as referenced in the Seventh Edition of
the Florida Building Code(2020).
Intertek has verified that the referenced certification documents are currently under surveillance services with
Intertek for the Florida Building Code. Attached is the current Certification Agreement between Intertek and
Clopay Building Products. This agreement also may be referenced as a CIA contract that bears no expiration
date and as such does not expire except upon its termination and is valid indefinitely.
Sincerely,
INTERTEK TESTING SERVICES NA, INC.
Reported by: Reviewed by:
John Schachtner Andrew Holstein, Ph.D.
Project Engineer-Evaluation Services Sr. Project Engineer—Evaluation Services
E� 0%-
Intertek Intertek Intertek
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are
limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,
expense or damage occasioned by the use of this report.Only the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any
use of the Intertek name or one of its marks.for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The Oi
observations and test results in this report are relevant only the sample tested. This report by itself does not imply thatthe material,product or service is or has ever
been under an Intertek certification program.
Version:02 August 2017 Page 1 of 1 SFT-BC-OP-19b
Intertek
Total Quality.Assured.
Certification Agreement for Applicants and Manufacturers
24th November 20
THIS AGREEMENT made the day of ,.20 , by and between:
INTERTEK TESTING SERVICES NA, INC. having offices at
545 E.Algonquin Rd,Arlington-Heights, IL 60005 USA("Intertek")
and "Company", having principle place of business at
Company Legal Entity Name Clopay Corporation
Street 8585 Duke Blvd
City, State/Province, Postal Code Mason,OH 45373
Country USA
Company is entering the Certification Agreementas a(n): ❑■ Applicant* ❑■ Manufacturer*.
*See definitions below.If the entity is both the Applicant and Manufacturer, please check both boxes.
If the Applicant and Manufacturer are different,please check the box that is applicable.
RECITALS
Intertek provides a service for evaluating whether products provided by the Applicant comply with
designated standards or specified requirements. Subject to the terms of this Certification Agreement,
products found to be in compliance by Intertek may be eligible for inclusion on a list maintained by Intertek
for Products to display a Certification Mark owned by Intertek.
The Applicant desires to submit or has submitted certain devices, equipment, materials, or systems
manufactured by the Applicant or the Manufacturer if different, to Intertek for evaluation in order that the
product may be considered for Listing and Labeling by Intertek.
If the submitted product is found to be eligible for Certification, this Certification Agreement shall be
executed by Intertek and the Applicant (and the Manufacturer, if applicable) setting forth the terms and
conditions to which the parties hereto must adhere.
NOW THEREFORE, for and in consideration of the mutual covenants herein expressed and other lawful
and valuable consideration, the parties hereto agree'as follows:
1. DEFINITIONS
1.1 Applicant. The term Applicant shall mean the company who submitted the product for evaluation
and certification and owns rights to Listing Reports.
1.2 Manufacturer. The term Manufacturer shall mean the company who carries out or controls certain
stages in the manufacture, assessment, handling, and storage of a product that enables it to accept
responsibility for continued compliance of the product with the relevant requirements and undertakes
all obligations to apply the certification labels.
1.3 Company.The term Company shall mean both Applicant and/or Manufacturer.
1.4 Authorization to Mark.The term Authorization to Mark("ATM")shall mean a written document from
Intertek that authorizes the Manufacturer to apply an Intertek certification mark to a specific product.
1.5 Certification,Mark.The term Certification Mark("Mark")shall refer to any common law or registered
trademark owned by Intertek, or its affiliates, used in the certification of Product.
1.6 Follow-up Service. The term Follow-up Service shall refer to the process of monitoring the
Company's compliance with the Intertek Requirements.
Page 1 of 7 SFT-ETL-OP-19e Revised 8-May 2018
intertek
Total Quality.Assured.
Certification Agreement for Applicants and Manufacturers
1.7 Intertek Requirements.The term Intertek Requirements shall mean(a)the requirements contained
in the Listing Report; (b) the standard(s), if any, applicable to the Product; (c) the terms of this
Certification Agreement; and (d) any third party requirements separately applied as a condition of
the Listing.
1.8 Labeling.The term Labeling shall refer to the process of applying the Mark to the Product,whether
the Mark is applied to the Product by a separable label, directly on the product, or by other media
as authorized by Intertek.
1.9 Listing. The term Listing shall mean the process of preparing and including the Product in the
published directory of Intertek certified products.
1.10 Listing Report.The term Listing Report shall mean the document prepared by Intertek, also known
as Constructional Data Report(CDR),which identifies the Company,the Product,the requirements
specific for the Product, including but not limited to, identification of standard(s), test protocols and
the type and form of Mark which must be used on or in connection with the Product and related
information.
1.11 Product. The term Product ("Product") shall mean an Applicant's device, equipment, material, or
system that has been submitted for testing or evaluation, and found to be in compliance with Intertek
Requirements and approved for Listing.
2. CERTIFICATION
2.1 Testing and Evaluation. Intertek is an independent laboratory providing testing and evaluation
services to determine whether representative samples of a product comply with designated national
and international standards, specifications, and/or codes. Intertek does not publish standards,
specifications, and/or codes, or warrant to the Company that the standard used for the evaluation is
adequate. Company understands and agrees that Intertek has only tested or evaluated the
submitted Product samples and does not guarantee or warrant the quality or compliance of all units
of the Product manufactured or produced by the Applicant and/or the Manufacturer. Company
further acknowledges that as an independent laboratory, Intertek assumes no responsibility for the
design of the Product.
2.2 Company Obligations. Company understands its obligations pursuant to this Certification
Agreement in order to maintain eligibility for Listing, and warrants that it shall comply with the
following provisions:
(a) Company agrees to notify Intertek, without delay, of changes that may affect its ability to
comply with this Certification Agreement or maintain eligibility for Listing. Changes may
include, but are not limited to:
• Modifications or changes to the Product such that the Product no longer meets the
requirements of the Listing Report for the Product
• Modifications to the Production Method
• Changes to the legal, commercial, organizational status or ownership
• Changes to Company or Manufacturer address
• Major Changes to the Quality Management System of the Company
If the Company wishes to make such modifications or changes,the Company must first either
obtain the approval of Intertek or discontinue use of the Mark.The Product may no longer be
eligible for Listing if the above modifications or changes to the Product,or the Company, have
occurred after Intertek's testing or evaluation.
(b) Upon request, the Company agrees that it shall retain or make available a sample of the
certified Product from the most current production.
(c) Company agrees to notify Intertek in writing of any product recall or reports that it receives of
serious personal injury or property damage involving the Product.
(d) Company shall notify Intertek of any labeled Product which has left the control of the Company
that does not comply with Intertek Requirements.
(e) Company warrants that a quality control program is, or will be, established and maintained to
ensure Product compliance with the Intertek Requirements.
(f) If re-evaluation and/or investigation of the product is required as a result of modification to the
Product without prior notification by the Company and approval by Intertek,the Applicant shall
Page 2 of 7 SFT-ETL-OP-19e Revised 8 May 2018
Intertek
Total Quality.Assured.
Certification Agreement for.Applicants and Manufacturers
be subject to applicable fees for these services.
(g) If the company provides copies of the certification documents to others, the documents shall
be reproduced in their entirety.
(h) Company agrees to fully cooperate with Intertek in any investigation of complaint including,
but not limited to, promptly providing sample(s), photograph(s), schematic(s), and
documentation related to product production, inventory, and shipment.
(i) Company shall maintain written records of all complaints made known to it relating to
compliance with certification requirements and the actions taken with respect to such
complaints and any deficiencies found in products that, affect compliance with the
requirements for certification. Company will promptly provide these records to Intertek upon
request.
2.3 Reservation of Rights. Intertek reserves the right, upon reasonable written notice to the Applicant,
to reevaluate the Product at the Applicant's expense.This re-evaluation may be the result of Follow-
up Service (Variation Notice), a revision of the applicable standard (Standard Update Notice
("SUN")), new information regarding the characteristics of the material used in the Product, or other
information (including administrative changes) that raises a question concerning the conformance
of the Product to Intertek Report Requirements. Such reevaluation may require Intertek to review
the Listing Report, reevaluate the product and update our records and be subject to applicable fees.
2.4 Revision or Withdrawal of the Intertek Requirements. Intertek reserves the right, upon
reasonable notice to the Applicant, to revise or withdraw the Intertek Requirements to the extent
required by applicable statutory guidelines or standards. If the Intertek Requirements are revised,
the Company shall be entitled to continue Listing and Labeling of the Product upon a demonstration
to the satisfaction of Intertek that the Product complies with the revised Intertek Requirements. If the
Intertek Requirements are withdrawn,the Company's right to the Listing and Labeling of the Product
shall terminate pursuant to the terms of Article 6 of this Certification Agreement. In the case of a
revision or withdrawal of Intertek Requirements, Intertek shall provide a notice specifying a
reasonable date by which the Product must meet the revised Intertek Requirements or for such
termination.
2.5 Third Parties. Applicant agrees that Intertek has entered into a contractual relationship with the
Applicant to perform testing or evaluation services on the Product. Intertek agrees to perform such
services with due care. Intertek does not guarantee or warrant that third parties will accept or
recognize the results obtained by Intertek or the Intertek certification of the Product.
3. LISTING AND LABELING
3.1 Ownership of the Mark. Ownership of the Mark and all trademark rights in the Mark remain in
Intertek, even if it is used on the Product.The Mark shall only be applied to a Product that complies
with the Intertek Requirements and such Mark shall be applied as specified in the Listing Report.
The Mark may be applied only to those models and brands that are specifically named in the Listing
Report at the factory receiving active Follow-up Service and as noted on the Authorization to Mark.
Except as provided herein and as indicated in Article 3.2, any other use of the Mark, or the Intertek
name, on the Product is expressly prohibited.
3.2 Advertising. Intertek shall allow the Company to refer to Intertek and the Mark in advertising and
promotional material for the Product, contingent upon the Company obtaining the prior, express,
written approval of Intertek.
3.3 Follow-up Service. As a part of the Listing and Labeling of the Product, the Company shall
cooperate with the Intertek representatives who conduct Follow-up Service and make all necessary
arrangements for the participation of observers. Follow-up Service may include factory audits at any
time during business hours and such Intertek representatives, shall have free, unannounced, and
immediate access to the Company's premises wherein the Product, or components thereof, may be
fabricated, processed,finished,stored,or located. Intertek representatives shall comply with factory
policies as required while on premises. Follow-up Service is intended to allow Intertek to monitor the
Company's compliance with maintaining continuing conformity of the Product to the Intertek
Requirements, and to control the use of Intertek's Marks. The factory audits are not intended to
Page 3 of 7 SFT-ETL-OP-19e Revised 8 May 2018
intertchk
Total Quality.Assured,
Certification Agreement for Applicants and Manufacturers
satisfy or otherwise replace Company's responsibility to maintain its quality control program and to
ensure that the Product remains in compliance with the Intertek Requirements. Follow-up Service
may also include Company questionnaires, and/or the Company's warranty of conformity.
4. INDEMNIFICATION AND LIABILITY
4.1 Indemnification. Company agrees to hold Intertek harmless and to defend and indemnify Intertek
against any liability, loss, or damage from claims, demands, costs (including legal fees), or judgments
arising out of any negligent or intentional acts of the Company, or claims from third parties relating to
the Product or arising from the use of the Mark.
4.2 Liability. Intertek will not, under any circumstances, be liable to the Company for any indirect,
special, punitive, or consequential damages, or any third party claims which may arise as a result of
the services provided in this Certification Agreement. The maximum aggregate liability of Intertek
for damages in connection with this Certification Agreement shall not exceed the latest annual fee
paid to Intertek by the Company.
5. FAILURE TO COMPLY WITH INTERTEK REQUIREMENTS
5.1 Remedial Action. In the event that Intertek detects any deviation or variance in the Product from
Intertek Requirements, or improper or unauthorized use of the Mark or Intertek name, Intertek will
notify the Applicant and require the Company, at its own expense,to undertake corrective action to
ensure that the Product complies with Intertek Requirements. Intertek reserves the right, in its sole
discretion,to take additional actions as it deems necessary, including but not limitedto:
(a) Suspension or revocation of the Listing and the right to label the Product;
(b) Withdrawal of the supply of labels and removal of the Mark from non-conforming or
unauthorized products;
(c) Payment of penalty fees(as defined in general information package)and any costs associated
with the product investigation by the Applicant;
(d) Removal of the Product from the published directory of Intertek certified products;
(e) Termination of this Certification Agreement pursuant to Article 6;
(f) Notification of regulatory authorities and the public;
(g) Compliance with any applicable statutes, rules, or regulations.
5.2 Injunctive Relief. Company acknowledges that the manufacture, sale, delivery, shipment,
distribution,or promotion of the Product utilizing a Mark would mislead or endanger the public if such
Product is not eligible to use the Mark or does not comply with the Intertek Requirements. Company
further acknowledges that a breach of this Certification Agreement cannot be adequately,
compensated by money damages.Company agrees that in the event of a breach of the Certification
Agreement, Intertek shall have the right to seek a temporary restraining order to the Company,
together with an action for a preliminary and permanent injunction, and such other and furtherrelief
as may be provided by law.
5.3 Suspension. Upon Company's failure to comply with any of the requirements of this Certification
Agreement or Listing Report, Intertek may issue a letter of suspension which shall notify the
Applicant of the nature of the failure and the period of suspension of the Company's right of Labeling.
The Applicant is obligated to notify its Manufacturer of the suspension and insure both the Applicant
and Manufacturer adhere to all requirements in the letter of suspension including remedial actions.
A reinstatement fee may be applied. In the event that the Company fails to take corrective action to
resolve the cause of suspension,this Certification Agreement shall be terminated pursuant to Article
6.
5.4 Public Notice. In the event that Intertek has confirmed evidence that the Product in the marketplace
has a significant non-conformity, Intertek will contact the Applicant and act in support of remedial
steps taken by the Company to address the non-conformity, including, if necessary, public
notification and/or a product recall undertaken by the Company. In the event that the Company does
not take action to address a significant non-conformity related to the Product, Intertek reserves the
right to contact appropriate government agencies, other parties in the supply chain and/or issue
Page 4 of 7 SFT-ETL-OP-19e Revised 8 May 2018
Intertek
Total Quality.Assured.
Certification Agreement for Applicants and Manufacturers
public notifications advising of the non-conformity pursuant to Article 5.1(f)above.
6. TERMINATION OF THE AGREEMENT'
6.1 Termination By Either Party. Either party may, for any reason, terminate this Certification
Agreement, as to any Product, upon not less than sixty (60) days written notice to the other party.
Such notice.shall designate a termination date and the notice period shall be deemed to commence
upon the date of mailing of the notice to the other party by registered or certified mail, return receipt
requested or by courier with confirmed delivery.
6.2 Intertek Right To Terminate. Intertek may terminate this Certification Agreement, as to any
Product,without prejudice to any other rights or remedies that Intertek may have, upon either of the
following:
(a) Immediately upon written notice, if Intertek determines that the Product fails to comply with.
the Intertek Requirements and such defect was not cured within a reasonable period of time;
(b) Company is in default pursuant to Article 7.3;
(c) Thirty (30) days after the Company receives written notice in the event of: (i) the filing of a
voluntary or involuntary petition in bankruptcy by the Company; (ii) the making of any
arrangement or composition with creditors by the Company; (iii)the appointment of a receiver
for the Company; or (iv) the voluntary or involuntary liquidation of the business of the
Company. The Company will notify Intertek within seven (7) days of notice of one of these
events.
6.3 Company Obligations Upon Termination. Upon termination.of this Certification Agreement,
Company shall:
(a) Discontinue the use of the Mark on the Product or 'Company's promotional material or
advertising.
(b) 'Allow Intertek to perform a final factory inspection to record final production status and to
recover all unused Intertek Certification Marks upon notification of,termination of the
Authorization to Mark. Fees for a final inspection will be billed.in accordance with Article 7.3
of this Certification Agreement.
(c) Promptly return to Intertek all Marks, Labeling material, and the Listing Report,and warrant in
writing'the date of last use of the Mark.
(d) Continue to honor the terms-of Article 4 of this Certification Agreement concerning
indemnification and liability, which terms shall survive the termination of this Certification
Agreement.
(e) Pay any remaining outstanding charges owing to Intertek immediately.
(f) Applicant is obligated to notify its Manufacturer of the termination and insure both the Applicant
and Manufacturer comply with all requirements in this section.
7. ADMINISTRATIVE PROVISIONS
7.1 Confidentiality.Without written authorization from the Applicant, Intertek will not voluntarily disclose
to third parties confidential and proprietary information which Applicant provides to Intertek. This
obligation shall not apply to information which is already available to the public, or acquired from
other sources without confidentiality restrictions, or is required to be disclosed by Intertek to
Regulatory Authorities responsible for the acceptance of the Product. Intertek agrees that this
obligation to maintain confidentiality shall survive the termination of this Certification Agreement.
7.2 Subpoena. If Intertek is served with a Subpoena, Court.Order, or similar document requesting the
disclosure of confidential or proprietary information supplied to Intertek by the Company, Intertek
shall promptly notify.the Applicant. In the event that the Applicant chooses to contest the.request,
Intertek shall cooperate with the Applicant. The responsibility for contesting the request shall rest
solely: with the Applicant. If the Applicant declines to contest the request or is not successful in
contesting the request, Intertek will provide the requested information.Any costs incurred by Intertek:
in responding to the request, including reasonable attorney's fees, shall be reimbursed by the
Applicant immediately upon invoicing by Intertek.
Page 5 of 7 SFT-ETL-OP-19e Revised 8 May 2018
intertek
Total Quality.Assured.
Certification Agreement for Applicants and Manufacturers
7.3 Fees. Certification fees will be prepaid or billed to the Applicant or a designated payor. Payment
shall be due upon presentation of invoices. The Applicant shall be considered in default if the
charges are not paid within thirty (30) days, unless other payment terms have been agreed upon.
Intertek reserves the right to adjust the billing rate for Certification, and to issue reasonable charges
in the event additional costs are incurred by Intertek as a result of Company's failure to adhere to
the Intertek Requirements. Additional costs include, but are not limited to, penalty fees for misuse
of Mark and costs associated with the product investigation. Certification fees are non-refundable.
7.4 No Assignment.The rights running to the Company under this Certification Agreement may not be
assigned to or acquired by any other person or corporation without Intertek's written authorization.
7.5 Term.This Certification Agreement shall continue in effect for a period of one(1)year from the date
first above written and shall automatically be renewed thereafter for periods of one (1)year, unless
the termination rights provided for in this Certification Agreement are exercised.
7.6 Jurisdiction.This Certification Agreement shall be interpreted in accordance with and governed by
the laws of the jurisdiction within which the Intertek office stated in the opening paragraph is located.
If the Client is located in China, any dispute or claim arising from or in connection with this
Certification Agreement, its breach, its performance or non- performance shall be submitted to the
China International Economic and Trade Arbitration Commission ("CIETAC") Beijing. Office for
arbitration which shall be conducted in accordance with the Commission's arbitration rules in effect
at the time of applying for arbitration.The arbitral tribunal shall consist of three(3)arbitrators. Intertek
on the one part and the Client on the other part shall each appoint one arbitrator. The parties shall
appoint the third arbitrator. If the parties fail to agree on the third arbitrator within fifteen (15) days
from the date on which the respondent receives the notice of arbitration,the parties hereby designate
the Chairman of CIETAC as the appointing authority hereunder provided that the Chairman shall
select an arbitrator who satisfies the qualifications in the preceding sentence. The language to be
used in the arbitral proceedings shall be Chinese and English. Each version shall have the equal
validity and legal effect.The arbitral award is final and binding upon both parties.
This Agreement is accepted and duly executed by:
Intertek Testing Services NA, Inc. Company Clopay Corporation
By By-
Authonzed lnferte(c Signatory Propnetor,Parfner orAuthorized.Officer-Signature
.Pr-int Nan'le For Jean-Philippe Kayl Print Name ' ;.;
Tltle ; Vice President-Global Certification T.Itle
-Date Date
Page 6 of 7 SFT-ETL-OP-1ge Revised 8 May 2018
Intertek
Total Quality.Assured.
Certification Agreement for Applicants and Manufacturers
7.3 Fees. Certification fees will be prepaid or billed to the Applicant or a designated payor. Payment
shall be due upon presentation of invoices. The Applicant shall be considered in default if the
charges are not paid within thirty (30) days, unless other payment terms have been agreed upon.
Intertek reserves the right to adjust the billing rate for Certification, and to issue reasonable charges
in the event additional costs are incurred by Intertek as a result of Company's failure to adhere to
the Intertek Requirements. Additional costs include, but are not limited to, penalty fees for misuse
of Mark and costs associated with the product investigation. Certification fees are non-refundable.
7.4 No Assignment.The rights running to the Company under this Certification Agreement may not be
assigned to or acquired by any other person or corporation without Intertek's written authorization.
7.5 Term.This Certification Agreement shall continue in effect for a period of one(1)year from the date
first above written and shall automatically be renewed thereafter for periods of one (1)year, unless
the termination rights provided for in this Certification Agreement are exercised.
7.6 Jurisdiction.This Certification Agreement shall be interpreted in accordance with and governed by
the laws of the jurisdiction within which the Intertek office stated in the opening paragraph is located.
If the Client is located in China, any dispute or claim arising from or in connection with this
Certification Agreement, its breach, its performance or non-performance shall be submitted to the
China International Economic and Trade Arbitration Commission ("CIETAC°) Beijing Office for
arbitration which shall be:conducted in accordance with the Commission's arbitration rules in effect
atthe time of applying for arbitration.The arbitral tribunal shall consist of three(3)arbitrators.Intertek
on the one part and the Client on the other part shall each appoint one arbitrator. The parties shall
appoint the third arbitrator. If the parties fail to agree on the third arbitrator within fifteen (1.5) days
from the date onwhich the respondent receives the notice of arbitration,the parties hereby designate
the Chairman of CIETAC as the appointing authority hereunder provided that the Chairman shall
select an arbitrator who satisfies the qualifications in the preceding sentence. The language to be
used in the arbitral proceedings shall be Chinese and English. Each version shall have the equal
validity and legal effect.The arbitral award is final and binding upon both parties.
This Agreement is accepted and duly executed by:
Intertek Testing Services NA, Inc. Company ciopay Corporation
By �+2 by
Aufhorized Intertek Signatory Propriefor-,-Partner orAut:orized OfficO Sigriature
Print Name JFor Jean-Philippe Kayl Print Name L, /,1 L tr r 5.
Title' lVice President-Global Certification Title S✓ r' c rvG„ � rt/C'
Date_ 12/9/20 Date Z -Z,_;2
Page 6 of 7 SFT-ETL-OP-19e Revised 8 May 2018
tntertek
Total Quality.Assured.
Certification Agreement for Applicants and Manufacturers
Addendum A
Certification and follow-Up Service Program Fees
Acceptance,by signature,of the Certification Agreement further signifies acknowledgement of the ongoing fees for the program. Invoicing
will commence upon Certification being granted,and will thereafter occur at the beginning of each Quarter.If a Purchase Order is required
in order to secure payment,please enter you PO number below.
The fees for our Certification Program are as follows, and are ner Manufacturing Location:
ONE TIME SET-UP FEE: $190.00
ANNUAL LISTING FEE"(1-5 Listings): $1,165.00
ADDITIONAL LISTING FEE (more than 5 Listings): $555.00
QUARTERLY CERTIFICATION FEE (includes Certrfication,Inspection*,and expenses):
Urnted States&RCanada ` $815 0.0'
Asia Pacific and South Artierica(including Mexico) $1,255.00
Middle East $1,425.00
Europe $2,350.00
Africa $2,070.00
Add UK Notified Body Certificate for CPR Europe: $1,085.00 (Annual)
*NOTE.For locations that have more than Quarterly Inspections,the following fees will apply for additional Inspections and will be
invoiced separately(includes expenses)
United States&Canada $465.00
Asia-Pacific and South America(including Mexico) $905.00
Middle East $1,075.00
'Africa $2,000.00
Europe $1,720.00
Annual Direct Imprint Fee (if applicable): $665.00
Annual Quality Assurance Fee (per QA program): $555:00
Multiple Listee arrangements,if applicable,are charged$830.00 annually per Multiple Listee.
Should our Engineering Services determine there are non-certified components deemed critical in the products meeting test requirements,
ongoing Verification Testing may be required.This is determined during the Testing and Listing Development process,and will be
specifically noted in the Listing Report.These fees will be quoted separately.
Any Technical changes to reports to address Variance/Variation items or Standard Updates may incur additional charges.These fees will
be quoted separately,upon instance.
*Certification fees are subject to slight annual increases
For further clarification on Fees,or to determine total costs,please contact the Building Products Certification Help Desk at
bpcertheipdesk@intertek.com or via phone at:(855)944-2378.
PO#:
This information is for the exclusive.use of Intertek's Client and is provided pursuant to the Certification Agreement between Intertek and its
Client.Intertek's responsibility and liability are limited to the terms and conditions of the Agreement.Intertek assumes no liability to any
party,other than to the Client in accordance with the Agreement,for any loss,expense,or damage occasioned by the use of this
information.
Page 7 of 7 SFT-ETL-OP-19e Revised 8 May 2018
4 3411, 2
'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SHEET: REVISIONS
MODELS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 1 OF 4 REV. N0. ZONE: DATE: ECN NO. APPVD: DESCRIPTION
CLOPAY 84A,94 73,75 76 CLOPAY
IDEAL 4RST, 4F� 6RST 2RST 'GALLERY' GD5S, GRSS -- 18 - 5/19/16 - SH REVISED ROLLER CALL-OUT.
HOLMES 48, 48B I42, 42H -- HOLMES AR5S -- 19 111/16/201 SH UPDATED TITLE BLOCK AND REMOVED WIND CHART.
SHORT PANEL I LONG PANEL 'ARTISTRY'
IDEAL
■ -MODEL 4F IS FLUSH 'CARRIAGE HOUSE' ED5S --
D SHORT PANEL I LONG PANEL SHORT PANEL/FLUSH MODELS, (1) INTERMEDIATE STILE BETWEEN EACH D
EMBOSS [(3) STILES PER SECTION AT 9'0" WIDE]. EACH INTERM. STILE
OPTIONAL GLAZING MAY BE ATTACHED WITH TOG-L-LOC (TOP & BOTTOM) AND URETHANE ADHESIVE
STANDARD OR IMPACT RESISTANT (ALONG CENTER).
GLAZING. SEE SECTION B-B ON LONG PANEL MOD • (3) TOTAL STILES PER SECTION. (1) STANDARD
SHEET 2 FOR DETAILS. INTERMEDIATE STILE BETWEEN EACH EMBOSS. EACH STANDARD INTERM.
MAX. STANDARD SIZE IS STILE ATTACHED WITH TOG-L-LOC (TOP & BOTTOM) AND URETHANE
19-1/2"xt6". IMPACT.RESISTANT ADHESIVE (ALONG CENTER). EXTRA INTERM. STILES (1) PER LONG PANEL
DOOR HEIGHT # OF # OF U-BARS GLAZING IS 21-5/8"x14-1/8". PER SECTION, FIELD-INSTALLED WITH (4) #8 SMS (PER STILE).
SECTIONS MAX DLO SIZE IS 18-1/2"x11",
UP TO 7'0' 4 6 A END STILES ATTACHED TO DOOR
7'3' TO B'9' 5 8 SKIN WITH PATENTED TOG-L-LOC
9'0' TO 10'6' 6 9 SYSTEM (TOP, BOTTOM, & CENTER).
10'9' TO 12'3' 7 11 0 J/ sV SEE END HINGE
12'6' TO 14'0' 8 12 VIEW B.
C 14'3' TO 15'9' 9 14 rn
1610' 10 IS o C
MAX SECTION HEIGHT, 21'
0
SEE INTERMED. HINGE
.O VIEW C. SLIDE BOLT LOCK
cFi ENGAGES INTO
0 y END
DSTILE VERTICAL TRACK.
ONE LOCK ON
� EACH SIDE OF
CIO DOOR.
x�
4-
02 TWO POINT LOCKING INSIDE SLIDE BOLT
ox INTO TRACK SNAP LATCH ENGAGES LOCK OPTION.
END
GONE SNAP CLATCH ON STILE.
--- -- ;INSIDE
OF DOOR.
B OUTSIDE B
HANDLE. LOCK BAR
OPTIONAL OUTSIDE KEYED LOCATION OF A OUTSIDEEND ENGAGES IN
LOCK POSITION OPTIONAL VENT I KEYED TRACK ON
MAX. DOOR WIDTH = 9'-0'—�{I HANDLE ' EACH SIDE
INSIDE ELEVATION HANDLE OF DOOR.
'CLASSIC' SHORT RAISED-PANEL SHOWN. LONG 'CLASSIC' OUTSIDE KEYED LOCK WITH OUTSIDE KEYED LOCK WITH
AND SHORT 'CARRIAGE HOUSE' ARE ALSO APPROVED. SNAP LATCH LOCK OPTION, LOCK BAR LOCKING.
#14x5/8" SHEET
METAL SCREWS MANUFACTURING PRODUCT CODE
SHORT PANEL, PAN-21`153
vwc ..,,,,,•,,,,..,-,,,., ::.s;on LONG PANEL, PAN-2F156
A
DESIGN LOADS: 7.0 P P.S.F. & P.S.F. PART NO.: N/A
1/4"z3/4" SELF TEST LOADS: +57.0 P.S.F. & -66.0 6.0 P.S.
P.S.F. ^
TAPPING SCREWS Univa seated Othen iae C Clopay Mason DOH 4550040 USA VINDLOA➢ RATING /1
00 0 TOLERANCES ara Tel.No.513-770-48M C .0 - d:.031 CORPORATION Fax No.513-770-4W W 6 D P 3 8
.00 - t.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
I--- - -- -- - 14 GA. END HINGES 18 GA. INTERMEDIATE •HIN .600 :E 005
DESIGN ENGINEER, VEW "B• VIEW "C" 0000= 1.001 DRAWN BY: MW DATE: 3/15/95 SCALE: NTS DWG.
Degrees = t1/2' CHECKED BY: -- DATE: -- SHEET 1 OF 4 ISIZE L
SCOTT HAMILTON, P.E. Unless Stated Otheralee
FLORIDA LICENSE No. 63286 DIMENSIONS ARE IN INCHES.I DWG. NO.: 101348 —A/B VER: IBC
4 3 2 1
'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE' RAISED PANEL EMBOSS DOORS SHEET, REVISIONS
MODELS 1 24 GA 1 25 GA 25 GA MODELS 25 GA 25 GA 2 OF 4 REV. NO. ZONE: DATE: ECN NO. APPVD: DESCRIPTION
CLOPA84A,4F� 6RST GALLERY'
73,75 78 CLOPAY
IDEAL 4RST,4F GDSS,GR5S -- 19 - - - - SEE REVISION HISTORY ON SHEET ONE.
IDEAL 2RST '
HOLMES 46,48H 142,4211 -- HOLMES AR5S --
SHORT PANEL -LONG PANEL 'ARTISTRY'
IDEAL ED5S
D ■ - MODEL 4F IS FLUSH 'CARRIAGE HOUSE' D
SHORT PANEL LONG PANEL
IMPACT—RESISTANT CONSTRUCTION: STANDARD ASSEMBLY CONSTRUCTION:
SOLID DOORS (NO GLAZING) OR DOORS WITH OPTIONAL IMPACT-RESISTANT GLAZING ARE OPTIONAL DSB OR 1/8'ACYRLIC LTTES AVAILABLE. OPTIONAL ACRYLIC GLAZING IS
IMPACT-RESISTANT. OPTIONAL INJECTION-MOLDED.POLYCARBONATE FRONT FRAME AND PLASKOLITE OPTIX OR LUCITE CP APPROVED CC2 PLASTIC IN ACCORDANCE WITH IBC/FBC
GLAZING IS GE LEXAN SLX2432T, AN APPROVED CC2 PLASTIC IN ACCORDANCE WITH 2605.
IBC/FBC 2606 AND AN APPROVED C1 PLASTIC IN ACCORDANCE WITH FBC 2612. THE ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE
THE ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE OR INTERNATIONAL BUILDING
WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE AND INTERNATIONAL BUILDING CODE BUT DOES NOT MEET THE IMPACT RESISTANT REQUIREMENT FOR WINDBORNE DEBRIS
CODE AND IS LARGE- AND SMALL-MISSILE IMPACT RESISTANT. REGIONS (REF. CHAPTER 16 FBC/IBC).
SECTION B-B (IMPACT-RESISTANT GLAZING OPTION) SECTION B-B (NON-IMPACT RESISTANT GLAZING OPTION)
C DETAIL'D' G
FRONT FRAME WITH U.V. COATING ON OUTSIDE SURFACE.
NOTE THAT FRONT FRAME IS NARROWER THAN
�// IMPACT-RESISTANT FRAME. t25
OPTIONAL DECORATIVE / 225 MULTIPURPOSE HIGH BOND TAPE
SNAP-IN INSERT. --_ (BEIWEEN FRAME ANO FACADE).
DECORATIVE FRONT FACADE ii n
J_�'_"' t GLAZING
MOLDED INSIDE
\ / UCTURAL SIUCONE SEALANT LITE RETAINER.
(BETWEEN STEEL SKIN AND FRAME). �j8z3/4' PAN HEAD SCREW
(10 SCREWS PER LITE).
IMPACT RESISTANT -
ONE-PIECE INJECTION POLY5ttRENE RETAINER FASTENED TO FRAME WITH
B MOLDED GE LEXAN (10) #B x 3/4'PAN HEAD MACHINE SCREWS.
SLX2432T FRONT B
FRAME&GLAZING.
IMPACT-RESISTANT ASSEMBLY DETAILS STANDARD ASSEMBLY DETAILS
DRAWING 101348-A DRAWING 101348-B
MANUFACTURING PRODUCT CODE
SHORT PANEL:- PAN-2F153
DESIGN LOADS: +38.0 P.S.F. & -44.0 P.S.F. LONG PANEL:* PAN-21`156
A TEST LOADS: +57.0 P.S.F. & -66.0 P.S.F. PART NO.: N/A ^
Urleee Stated Othereiee -nla ay 8585 Duke Boulevard VINDLOAD RATING A
TOLERANCES a e u P Maaon,OH 45M USA \./
.0 = f.031 PORATION In W.
513-7770 48�53 VV D P 3 8
.60 = d:.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
.000 f.005— DRAWN BY: MW DATE: 3/15 95 SCALE: NTS
.DODO = d:.00t / DWG.
DESIGN ENGINEER, Degrees = d:1/2' CHECKED BY: -- DATE: -- SHEET 2 OF 4 SIZE
SCOT
T HAMILTON. P.E. Unleee Stated OtAenlee
FLORIDA LICENSE No. 63286 DIMFIISIONS ME IN INCHES. DWG. NO.: 101348 — A/B VER: IBC
4 3 2 1
4 3 2 1
'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SHEETS REVISIONS
MODELS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 3 OF 4 REV. NO. ZONE: DATE: ECN NO. APPVD: DESCRIPTION
CLOPAY I 84A, 94 173, 75 76 CLOPAY
IDEAL em
2RST 'GALLERY' GD5S, GR5S -- 19 - - - - SEE REVISION HISTORY ON SHEET ONE.
HOLMES -- HOLMES ARSS --
'ARTISTRY'
LONG PANEL IDEAL 3" TALL U-BAR
■- MODEL 4F IS FLUSH 'CARRIAGE HOUSE' EDSS -- [—2" THICK 20 GA. GALV. STEEL
D SHORT PANEL I LONG PANEL MIN. YEILD STRENGTH: 50 KSI D
1 3-
VERTICAL JAMB ATTACHMENT (WOOD FRAME BUILDINGS):
3/8"x3" LAG SCREWS ON 24" CENTERS. 1-1/8" O.D. WASHER REQUIRED. LAG SCREWS MAY r
BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE.
HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 12 GA. GALV. STEEL TOP
VERTICAL JAMB ATTACHMENT (C-90 BLOCK OR 2.000 PSI MIN CONCRETE COLUMN): ROLLER BRACKET. EACH
3/8"x3" SLEEVE ANCHOR BOLTS ON 22" CENTERS (2,000 PSI MIN. CONCRETE). WASHERS BRACKET ATTACHED W/(4)
INCLUDED WITH SLEEVE ANCHORS. #14x5/8" SHEET METAL
OR
SCREWS.
1/4"x3" TAPCON SCREWS ON 19" CENTERS (2,000 PSI MIN. CONCRETE) OR 10" CENTERS 25 GA. MIN. G-40 GALV. SHIP LAP JOINTS.
(C-90 BLOCK). 1" O.D. WASHERS REQUIRED WITH TAPCONS. STEEL SKIN WITH A
ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING BAKED-ON PRIMER AND
SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. A BAKED-ON POLYESTER
C TOP COAT APPLIED TO 14 GA. GALV. STEEL END HINGE C
OTHER JAMB CONFIGURATIONS: REFER TO DASMA TDS-161. A LICENSED DESIGN BOTH SIDES OF STEEL FASTENED TO END STILES W/(4) EACH
PROFESSIONAL MAY ALSO BE EMPLOYED TO APPROVE ALTERNATE FASTENERS AND/OR JAMB SKIN. #14x5/8" SHEET METAL SCREWS & (4)
CONFIGURATIONS. 1/4" SELF TAPPING SCREWS.
PREPARATION OF JAMBS BY OTHERS
NOTE: THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE
RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING OR STRUCTURE AND 3" TALL x 20 GA. GALV. STEEL U-BARS
IN ACCORDANCE WITH CURRENT BUILDING CODES FOR THE LOADS LISTED ON THIS DRAWING. IN A 2-1-2-1 PATTERN(I.E. TWO
U-BARS ON BOTTOM SECTION, ONE
U-BAR ON NEXT SECTION, ETC.). EACH
U-BAR ATTACHED WITH (2) 1/4"0/4"
SELF TAPPING SCREWS PER STILE
LOCATION.
B B
13 GA. GALV. STEEL BOTTOM BRACKET.
ATTACHED WITH (2) #144/8" SHEET METAL SCREWS
ALUMINUM EXTRUSION
& VINYL WEATHERSTRIP.
SECTION A-A (SIDE VIEW)
MANUFACTURING PRODUCT CODE
SHORT PANEL: PAN-217153
LONG PANEL• PAN-2F156
DESIGN LOADS: +38.0 P.S.F. & -44.0 P.S.F.
A EST LOADS: +57.0 P.S.F. & -66.0 P.S.F. PART NO.: N/A
^
Unless stated Othen,iee Clopay Wass Duke Boulevard MINDLOAD RATING /-1
TOLERANCES are Mason,OH 4504D USA \ / D P 3 8
Tei.No. H 4504 USA W
.0 = f.031 CORPORATION Fax No.513-770-4853
.00 d:.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
_ .000 f.005
DESIGN ENGINEER .0000 = t.001 DRAWN BY: Mw DATE: 3/15/as SCALE: Nis DWG
Degrees = ±1/2 CHECKED BY: -- DATE: -- SHEET 3 OF 4 SIZE L
SCOTT HAMILTON, P.E. Unless Stated OtheWae
FLORIDA LICENSE No. 63286 DIMENSIONS ARE IN tNcHEs. DWG. NO.: 101348 - A/B VER: IBC
4 3 2 1
4 3 2 1
'CLASSIC' RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE' RAISED PANEL EMBOSS DDORS SHEET, REVISIONS
MODELS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 4 OF 4 REV. NO. ZONE: DATE: ECN NO. APPVD: DESCRIPTION
CLOPAY 84A, 94 73, 75 76 CLOPAY
I➢EAL 4RST, 4F1- 6RST 2RST GALLERY'
GDSS, GRSS -- 19 — — — — SEE REVISION HISTORY ON SHEET ONE.
'
HOLMES 48,4BB 42,42D -- HOLMES AR5S --
SHORT PANEL LONG PANEL 'ARTISTRY'
IDEAL EDSS
■—MODEL 4F IS FLUSH 'CARRIAGE HOUSE' D
D SHORT PANEL LDNG PANEL
2'TRACK CONFIGURATION. DOOR COUNTERBALANCE SYSTEM JAMB CONFIGURATION.
HORIZONTAL TRACK
13 GA GALV. STEEL FLAG BRACKET ATTACHED TO DOOR- SUPPORT BY DOOR
JAMB WITH (3)5/16"X 1-5/8'LAG SCREWS HEIGHT 'L' INSTALLER(TO SUIT).
/ AND TO TRACK WITH (2) 1/4'RIVETS. _
WM TRACK CONFIGURATION � — 2x6 SYP WOOD JAMB. SEE OPTIONAL STOP MOULDING BY INSTALLER (TO SUIT).
'JAMB PREPARATION NOTE". �.�
ABOVE THE DOOR OPENING DOES AS ROD:SPACING NTE 30"O.C. _ "'",'9,y";iy 20 CA GALV. STEEL END STILE.
NOT AFFECT THE WIND LOAD 20 GA. MIN. GALV. STEEL INTERM. STILE.
RATING OF THIS DOOR. —
62'd:4' 2"GALV.STEEL TRACK,
c TRACK THICKNESS: O.B83'. —6 2-1/2"X 12 GA GALV.STEEL
u TRACK BRACKETS FASTENED TO
-6 WOOD JAMBS WITH 5/6'X 1-5/8' 7/16-I.D.ROUND 18 GA.GALV.STEEL CENTER HINGE
—0 LAC SCREWS. PUSH NUT FASTENED TO INTER.STILES W/(4) EACH
—6 FASTENER. {114z5/8"SHEET METAL SCREWS.
36"t2" TYP, 2-1/2'X 12 GA GALV.
C z STEEL TRACK BRACKETS, — 14 GA. GALV.STEEL ROLLER HINGES FASTENED TO END STILES W/(4) EACH#14x5/8' C
ATTACHED TO JAMB WITH (1) 11AA. SHEET METAL SCREWS AND (4) 1/4"SELF TAPPING SCREWS PER END HINGE
0 5/16'X 1-5/8' LAG SCREW PER — 2"GALV. STEEL TRACK FASTENED TO
TRACK BRACKET. —0 12 GA GALV STEEL TRACK BRACKETS
4'— WITH ETHER (2) 1/4"DIA RNETS OR 2'DIA. SHORT STEM, 10 BALL STEEL ROLLER WITH STEEL OR NYLON TIRE.
10' 15 1— (1) 1/4'X 5/8'BOLT-& NUT PER SECTION C—C
3-1/2• — TRACK BRACKET.
• PREPARATION OF JAMBS BY OTHERS,
LHR BRACKET(2-1/2'x 5-3/4'x 12GA)
ATTACHED WITH (2) 1/4'x 3/4"SELF TAPPING
SCREVlS.
3" TRACK IS ALSO AVAILABLE,
DOUBLETRACK
LOW HEADROOM OPTION
DOUBLE HORIZONTAL
TRACK.
B B
MANUFACTURING PRODUCT CODE
SHORT PANEL PAN-2F153
LONG PANEL:* PAN-2F156
A
as DESIGN LOADS: P.S.F. & P.S.F. PART NO.: N A, V• ..�.ra,." ..._,. " TE T LOADS: +57.0 7.0 P P.S.F. h —66.0 6.0 P.S.
:S.F. / li
Unleee Stated OlherwI _ 8585 Duke Boulevard VINDLOAD RATING A
TOLERANCES a,e =CIOP Mason,ON 45040 USA \•/ n p Q
.0 f.031 CORPORATI D Fox W.
513—n0 48�5.T VV L I �-J'
.00 t.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
.0000 = t 001 DRAWN BY: MW DATE: 3/15/95 SCALE: NTS DWG,
DESIGN ENGINEER, Degrees = ±1/2' CHECKED BY: -- DATE: -- SHEET 4 OF 4 ISIZE
SCOTT HAMILTON, P.E. Unless Stated Othe Tee
FLORIDA LICENSE No. 63296 DIMENSIONS ARE INr INCHES. DWG. NO.: 101348 — A/B VER: IBC
4 3 2 1