Loading...
HomeMy WebLinkAboutInspection Docs/ COMPACTION TEST UES Project No: 3310.2100006.0000 A Universal Workorder No: 221921-1 Engineering Report Date: 01/08/2021 Sciences 144 Company fRNA710NP 607 Northwest Commodity Cove,Port St.Lucie,FL 34986 -P:772-924-3575 -F: 772-924-3580 In-Place Density Test Report Client: Kjartan H.Valdimarsson UES Technician: Mark Rogers 2390 S. Brocksmith Road Date Tested: 01/06/2021 Fort Pierce, FL 34945 Project: Valdimarsson Residence Deck Addition 2390 South Brocksmith Road, Fort Pierce, County, FL 34945 lype of Test: Area Tested: Foundation footings for 2nd floor balcony Field: ASTM D-6938 Nuclear Gauge Method Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0=Top of Footing The tests below meet the 95%minimum compaction requirement. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 Northern footings 0-1 ft 109.0 12.0 105.7 12.5 97 Pass 2 Southern footings 0-1 ft 109.0 12.0 106.3 12.7 98 Pass 3 Eastside footings 0-1 ft 109.0 12.0 105.0 12.6 96 Pass Reviewed By GFA International,Inc Certificate of Authorization No.4930 s Digitally signed John ct by John Kent A, ;` °Date: Ken ft rl-'-202:1 .08 67 15:19:54-05'00' John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No.63218 To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1