Loading...
HomeMy WebLinkAboutLOC 1.11.21 HERITAGE BUILDING SYSTEMS AstabUshed 1979 A Cornerstone Building Brands Company November 13, 2020 THOMPSONS REMODELING 3871 39TH SQUARE VERO BEACH, FL 17-B-86402 TODD THOMPSON 3200 N KINGS HWY FORT PIERCE, FL,34946 80'-0" x 125'-0" x 20'-0" To Whom It May Concern: This is to certify that materials for the subject structure have been designed in accordance with the order documents, specifically as shown per the attached Engineering Design Criteria Sheet. Aspects of code compliance as related to use or occupancy, such as sprinkler requirements, are not addressed by these documents. These materials, when properly erected on an adequate foundation in accordance with the erection drawings as supplied and using the components as furnished, will meet the attached loading requirements. This certification does not cover field modifications or the design of materials not furnished by Heritage Building Systems. The attached design criteria information is to remain with and form part of this Letter of Certification. The calculations and the metal building they represent are the product of Heritage Building Systems or a division of its affiliate Cornerstone Building Brands. The engineer whose seal appears hereon is employed by either Heritage Building Systems or a division of its affiliate Cornerstone Building Brands and is not the engineer of record for this project. Cordially, Heritage Building Systems Materials for Metal Buildings A Cornerstone Building Brands Company This document has been Anan Almughrabi, P.E. ,`� �aALMU{�y ��i digitally signed. Engineer IV +*� C�`;•`ZG E NS"•. 4 * � No 54510 xt - � 2020-11-20 STATE of :�,�' 15:15:24 .V 00'. �j S •••:...• "••� 1 17-B-86402 Expires 02-25-2021 Page l of 2 HERITAGE BUILDING SYSTEMS 1[stobUshed 1979 A Cornerstone Building Brands Company Building Code . . . . . . . . . . . . . . . . . . . . . . . FBC 17 Risk Category. . . . . . . . . . . . . . . . . . . . . . . . II - Normal Roof Dead Load Superimposed. . . . . . . . . . . . . . . . . . . . . . .2 .340 psf Collateral. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.000 psf (Total) (0.00 psf Ceiling, 6 psf Other) Roof Live Load. . . . . . . . . . . . . . . . . . . . . . . 20.00 psf Yes reduction Snow Ground Snow Load (Pg) . . . . . . . . . . . 0.00 psf Snow Load Importance Factor (Is) 1.00 Snow Exposure Factor (Ce) . . . . . . . 1.00 Thermal Factor (Ct) . . . . . . . . . . . . . 1.00 Flat Roof Snow Load (Pf) . . . . . . . . 0 psf Minimum Roof Snow Load (Pm) . . . . . 0.00 psf Wind Ultimate Wind Speed (Vult) . . . . . 160 mph Nominal Wind Speed (Vasd) . . . . . . 124 mph (IBC Section 1609.3. 1) Serviceability Wind Speed . . . . . 87 mph Wind Exposure Category . . . . . . . . . C Internal Pressure Coef (GCpi) 0.18/-0.18 Loads for components not provided by building manufacturer Wall Edge Zones 54 .15 psf pressure -72.06 psf suction Other Wall Zones 54. 15 psf pressure -58. 66 psf suction These values are the maximum values required based on a 10 sq ft area. Components with larger areas may have lower wind loads. 17-B-86402 Page 2 of 2