HomeMy WebLinkAboutEnergy CodeWhole Building Performance Method for Commercial Buildings Form 400A-97
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
FLA/COM-97 Version 2.2
PROJECT NAME -PGA LEARNING CENTER
ADDRESS: PORT ST. LUCIE, FLORIDA.
OWNER: _PGA
AGENT:
BUILDING TYPE: _Business (Office)
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: _Shell Building
CONDITIONED FLOOR AREA: _7844
MAX. TONNAGE OF EQUIPMENT PER SYSTEM:
COMPLIANCE CALCULATION:
PERMITTING OFFICE:
_Port St. Lucie
CLIMATE ZONE: 6
PERMIT NO:
JURISDICTION NO: 661200
5
NUMBER OF ZONES: 4
METHOD A DESIGN CRITERIA RESULT
----------------- -------------- ------
A. WHOLE BUILDING 45.70 100.00 PASSES
PRESCRIPTIVE REQUIREMENTS:
LIGIf f' .ZG
LIGHTING CONTROL REQUIREMENTS
PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER
12.00
10.00
PASSES
2. SEER
12.00
10.00
PASSES
3. SEER
12.00
10.00
PASSES
4. SEER
12.00
10.00
PASSES
HEATING EQUIPMENT
1. Et
12.00
N/A
2. Et
12.00
N/A
3. Et
12.00
N/A
4, Et
12.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION
REQUIREMENTS
1. Conditioned Space
6.00
0.00
N/A
2. Conditioned Space
6.00
0.00
N/A
3. Conditioned Space
6.00
0.00
N/A
4. Conditioned Space
6.00
0.00
N/A
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATING EQUIPMENT
1. EF
20.00
0.90
PASSES
yPIeING INSULATION REQUIREMENTS
1. Circulating
2.00
1.00
PASSES
----------------------------------------------------------------------------
COMPL'iANCE CERTIFICATION:
I hereby certify that the plans and Review of the plans and specifica-
specifications covered by this calcu- tions covered by this calculation
lation are in compliance with the indicates compliance with the
Florida Energy Efficiency Code.
PREPARED BY:
DATE:
T hereby certify that this. building is
,iin rompliance,,withh -th Florida Energy
Eff+iciency Code
(3WNER/AGENT:
DATE:
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in accordance with
Section 553.908, Florida Statutes.
BUILDING OFFICIAL:
DATE:
I hereby "certify() that the system design is in compliance with the Florida
Energy Effici'enay. Code.
SYSTEM DESIGNER REGISTRATION/STATE
ARCHITECT
MECHANICAL:_
PLUMBING _
ELECTRICAL:_
LIGHTING _
(*) Signature
by registered
be used where
is required where Florida law requires design to be performed
design professionals. Typed names and registration numbers may
all relevant information is contained on signed/sealed plans.
A
BUILDING
ENVELOPE SYSTEMS
COMPLIANCE
CHECK
401-.------GLAZING--ZONE
1------------------------------------------------
v-
F,levation
Type
U
----
SC VLT_
---- ----
Shading
--------------
Area(Sgft)
----------
---------
North
---------------
Commercial
1.31
.80 .10
None
100
South
Commercial
1.31
.80 .10
None
120
East
Commercial
1.31
.80 .10
None
100
West
Commercial
1.31
.80 .10
None
100
Total Glass Area in Zone 1
=
420
401.------GLAZING--ZONE
2------------------------------------------------
v-
Elevation
Type
U
----
SC VLT
---- ----
Shading
--------------
Area(Sgft)
----------
---------
North
---------------
Commercial
1.31
.80 .10
None
100
South
Commercial
1.31
.80 .10
None
0
East
Commercial
1.31
.80 .10
None
30
West
Commercial
1.31
.80 .10
None
0
Total Glass Area in Zone 2
=
130
401-------
GLAZING --ZONE 3------------------------------------------------
v-
Elevation
Type
---------------
U
----
SC VLT
---- ----
Shading
--------------
Area(Sgft)
----------
---------
North
Commercial
1.31
.80 .10
None
0
South
Commercial
1.31
.80 .10
None
0
East
Commercial
1.31
.80 .10
None
0
West
Commercial
1.31
.80 .10
None
0
Total Glass Area in Zone 3
=
0
401-------
GLAZING --ZONE 4------------------------------------------------
v-
Elevation
---------
Type
---------------
U
----
SC VLT
---- ----
Shading
--------------
Area(Sgft)
----------
North
Commercial
1.31
.80 .10
None
60
South
Commercial
1.31
.80 .10
None
460
East
Commercial
1.31
.80 .10
None
40
West
Commercial
1.31
.80 .10
None
40
Total Glass Area in Zone 4
=
600
Total Glass Area
=
1150
402-------
WALLS --ZONE
1------------------------------------------------
---
Elevation
Type
U Insul
R
Gross(Sgft)
---------
North
--------------------------------
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc
----- -------
0.149
4
-----------
720
South
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc
0.149
4
500
East
5/8"Stco/8"CMU/3/4"ISO
BTWN2411oc
0.149
4
220
West
5/8"Stco/8"CMU/3/4"ISO
BTWN2411oc
0.149
4
660
Total Wall Area in Zone 1
=
2100
402.------WALLS--ZONE
2------------------------------------------------
---
Elevation
Type
U Insul
R
Gross(Sgft)
---------
North
--------------------------------
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc
----- -------
0.149
4
-----------
0
South
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc
0.149
4
770
East
5/8"Stco/8"CMU/3/4"ISO
BTWN2411oc
0.149
4
200
West-
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc
0.149
4
130
Total Wall Area in Zone 2
=
1100
402.------WALLS--ZONE
3------------------------------------------------
---
Elevation
Type
U Insul
R
Gross(Sgft)
---------
North
--------------------------------
5/8"Stco/8"CMU/3/4"ISO
BTWN2411oc
----- -------
0.149
4
-----------
550
South
5/8"Stco/8"CMU/3/4"ISO
13TWN24"oc
0.149
4
0
East
5/8"Stco/8"CMU/3/4"ISO
BTWN2411oc
0.149
4
190
West
5/8"Stco/8"CMU/3/4"ISO BTWN2411oc 0.149
4
0
Total Wall Area in Zone
3 =
740
402.------WALLS--ZONE
4 ------------------------------------------------
Elevation
Type
U Insul
R
Gross(Sgft)
71--------
-----
------
--------------- - - - - -- - - - --- - -
- - --
----- - - - - - -
North
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc 0.149
4
440
South
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc 0.149
4
660
Fast
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc 0.149
4
150
West
5/8"Stco/8"CMU/3/4"ISO
BTWN24"oc 0.149
4
150
Total Wall Area in Zone
4 =
1400
Total Gross Wall Area
=
5340
403.------DOORS--ZONE
1 -------------------------------------------------
Elevation
Type
U
Area(Sgft)
----------
---------
North
------------------------------------------
1-3/8
Wood
-Door -Solid core flush
-----
0.39
0
South
1-3/8
Wood
Door -Solid core flush
0.39
0
East
1-3/8
Wood
Door -Solid core flush
0.39
24
West
1-3/8
Wood
Door -Solid core flush
0.39
48
Total Door Area in Zone
1 =
72
403.------DOORS--ZONE
2 ------------------------------------------------
Elevation
Type
U
Area(Sgft)
---------
North
------------------------------------------
1-3/8
Wood
Door -Solid core flush
-----
0.39
----------
0
South
1-3/8
Wood
Door -Solid core flush
0.39
0
East
1-3/8
Wood
Door -Solid core flush
0.39
48
West
1-3/8
Wood
Door -Solid core flush
0.39
24
Total Door Area in Zone
2 =
72
403.------DOORS--ZONE
3 ------------------------------------------------
Elevation
Type
U
Area(Sgft)
---------
North
------------------------------------------
1-3/8
Wood
Door -Panel with 7/16" panels
-----
0.57
----------
0
South
1-3/8
Wood
Door -Panel with 7/16" panels
0.57
0
East
1-3/8
Wood
Door -Panel with 7/16" panels
0.57
21
West
1-3/8
Wood
Door -Panel with 7/16" panels
0.57
0
Total Door Area in Zone
3 =
21
403.------DOORS--ZONE
4 ------------------------------------------------
Elevation
Type
U
Area (Sgft)
---------
North
------------------------------------------
1-3/8
Wood
Door -Panel with 7/16" panels
-----
0.57
----------
21
South
1-3/8
Wood
Door -Panel with 7/16" panels
0.57
0
East
1-3/8
Wood
Door -Panel with 7/16" panels
0.57
0
West
1-3/8
Wood
Door -Panel with 7/16" panels
0.57
0
Total Door Area in Zone
4 =
21
Total Door Area
=
186
404.------ROOFS--ZONE
1 ------------------------------------------------
Type
Color U Insul
R
Area(Sgft)
------------------------------------
Sngl Ply/3"Iso/l/2"WD
------ ------------
Deck/WD T Medium 0.040
30
----------
7840
Total Roof Area in Zone
1 =
7840
404.------ROOFS--ZONE
2 ------------------------------------------------
Type*
Color U Insul
R
Area(Sgft)
------------------------------------
Shngl/1/2"WD Deck/WD
------ ------------
Truss/9" B Medium 0.027
30
----------
0
Total Roof Area in Zone
2 =
0
404------- ROOFS --ZONE
3 ------------------------------------------------
Type
Color U Insul
R
Area(Sgft)
Conc Tile/1/2"WD Deck/WD Truss/ Medium 0.028 30 0
ti
Total
Roof Area
in Zone 3 =
0
404.------ROOFS--ZONE
4 ------------------------------------------------
Type
- - - - - - - -
- - - - - - -
Color
- - - - - - -
U Insul R
- - - - - - - - - - -
Area(Sgft)
- - - - - - - - - -
- - -r - - - -
Conc Tile/l/2"WD
- - - - - - - - - - - - -
Deck/WD Truss/
Medium 0.028
30
0
Total
Roof Area
in Zone 4 =
0
Total
Roof Area =
7840
4-05.------FLOORS-ZONE
I ------------------------------------------------
Type
Insul R
Area(Sgft)
Slab on
Grade/Uninsulated
.10
1280
Total
Floor Area
in Zone 1 =
1280
405.------FLOORS-ZONE
2 ------------------------------------------------
Type
Insul R
-------
Area(Sgft)
----------
------------------------------------------------
Slab on
Grade/Uninsulated
.10
2500
Total
Floor Area
in Zone 2 =
2500
405.------FLOORS-ZONE
3------------------------------------------------,
Type
Insul R
Area(Sgft)
Slab on
Grade/Uninsulated
.10
1600
Total
Floor Area
in Zone 3 =
.1600'
405.------FLOORS-ZONE
4 ------------------------------------------------
Type
Insul R
-------
Area (Sgft)
----------
------------------------------------------------
Slab on
Grade/Uninsulated
.10
2044
Total
Floor Area
in Zone 4 =
2044
Total
Floor Area =
7424
406.------INFILTRATION
--------------------------------------------------
ICHECK
Infiltration Criteria in 406.1.ABCD have been met.
MECHANICAL SYSTEMS
CHECK
---------------------------------------------------------
HVAC load sizing has been performed. (407.1.ABCD)
----
407.------COOLING
SYSTEMS -----------------------------------------------
Type No
Efficiency IPLV
Tons
1.
Split System 1
12 12
3.42
2.
Split System 1
12 12
3.79
3.
Split System 1
12 12
2.00
4.
Split System 1
12 12
5.00
408.------HEATING
SYSTEMS -----------------------------------------------
Type
No Efficiency
---------------------------
BTU/hr
1.
--------------------------------
Electric Resistance
1 12
7500
2.
Electric Resistance
1 12
7500
3.
Electric Resistance
1 12
7500
4.
Electric Resistance
1 12
7500
409,.-
----- VENTILATION ---------------------------------------------------
CHECK
Ventilation Criteria in 409.1.ABCD
have been met.
I
410 ------ AIR DISTRIBUTION SYSTEM----------------------------------------
CHECK------
---------------------------------------------------
Duct sizing and design have been performed. (410.1.ABCD)
----
AHU Type
Duct Location
R-value
1. Air Conditioners Conditioned Space 6
2. Air Conditioners Conditioned Space 6
3.•Air Conditioners Conditioned Space 6
.4. Air Conditioners Conditioned Space 6
CHECK
Testing and balancing will be performed. (410.1.ABCD)
411. ----- PUMPS AND PIPING -ZONE -----------------------------------------
Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411------ PUMPS AND PIPING -ZONE 1
Type
R-value/in
----------
Diameter
--------
Thickness
---------
1.
------------------------
Circulating
4
.75
2
411.-----PUMPS
AND PIPING -ZONE 2 ---------------------------------------
Type
R-value/in
----------
Diameter
--------
Thickness
---------
1.
------------------------
Circulating
4
.75
2
411.-----PUMPS
AND PIPING -ZONE 3 ---------------------------------------
Type
R-value/in
----------
Diameter
--------
Thickness
---------
1.
------------------------
Circulating
4
.75
2
411.-----PUMPS
AND PIPING -ZONE 4 ---------------------------------------
Type
R-value/in
----------
Diameter
--------
Thickness
---------
1.
------------------------
Circulating
4
.75
2
412------
WATER HEATING
SYSTEMS -ZONE 1 ----------------------------------
Type
------------------------
Efficiency
----------
StandbyLoss
--------------------
InputRate
Gallons
----------
412------
WATER -HEATING
SYSTEMS -ZONE 2 ----------------------------------
Type
Efficiency
----------
StandbyLoss
--------------------
InputRate
Gallons
----------
1.
------------------------
Electric(<=12 KW)
20
0
400
20
412------
WATER HEATING
SYSTEMS -ZONE 3 ----------------------------------
Type
------------------------
Efficiency
----------
StandbyLoss
--------------------
InputRate
Gallons
----------
412------
WATER HEATING
SYSTEMS -ZONE 4 ----------------------------------
Type
------------------------
Efficiency
----------
StandbyLoss
--------------------
InputRate
Gallons
----------
ELECTRICAL SYSTEMS
CHECK
413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- -----
Metering criteria in 413.1.ABCD have been met.
414.-----MOTORS --------------------------------------------------- -----
Motor efficiencies in 414.1.ABCD have been met.
415.-----LIGHTING SYSTEMS -ZONE 1 ---------------------------------------
Sp4ce Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
---------- ----------------- ----------------- --- ------ ----------
General Ex 1 On/Off 2 None 0 500 1280
Total Watts for Zone 1 = 500
Total Area for Zone 1 = 1280
415.-----LIGHTING SYSTEMS -ZONE 2 ---------------------------------------
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
---------- ----------------- ----------------- --- ----------------
Type D(Gen 1 On/Off
2 None
0
500
1800
Total Watts
for
Zone
2 =
500
Total Area
for
Zone
2 =
1800
415 ------ LIGHTING SYSTEMS -ZONE
3---------------------------------------
---
Space Type No Control Type 1
No Control Type 2
No
--- ------
Watts
Area(Sgft)
----------
---- ------ ----------------- ---
Recreation 1 On/Off
--------------
2 None
0
500
700
Total Watts
for
Zone
3 =
500
•
Total Area
for
Zone
3 =
700
415.-----LIGHTING SYSTEMS -ZONE
4---------------------------------------
---
Space Type No Control Type 1
No Control Type 2
No
Watts
Area(Sgft)
---------- ----------------- ---
Fast Food/ 1 On/Off
--------------
2 None
--- ------
0
500
----------
2044
Total Watts
for
Zone
4 =
500
Total Area
for
Zone
4 =
2044
Total
Watts
=
2000
Total
Area
=
5824
CHECK
Lighting criteria in 415.1.ABCD have been
met.
16. Operation/maintenance manual
----------------------------------------------------------------------------
will be provided
to owner.(102.1)