HomeMy WebLinkAboutNOA METALWOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING 15211 97D Road N West Palm Beach, FL 33412 Ph/Fr, (561) 225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1700 26 GA. GALVALUME SNAPLOCK 1 112" STANDING SEAM ROOF PANEL (FLPA4 30751.4) MANUFACTURER: DYNAMIC METALS, LLC 340 PIECE ROAD WEST PALM BEACH, FL 33411 To all concemed, The DM Class 1700 Series 26 Ga. Ga€valume Snap Lock 1 112' Standing Seam Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated or Flumpon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 71 Edition (2020) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shovm in test reports K1304.04-450-18 and K1304.01450-18, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing °1700SLHZ" dated 10117119, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRi Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 4. Supplemental Calculations to support °1700SLHZ° drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Ruie Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 71h Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 19" (nominal) Minimum Rib Height: 1 1/2' Clip Anchors: 20 Ga. Steel, 3112° long Min: Slope: 2112 (HVHZ) '/J12 (Non-HVHZ, with Lap Sealant) 3112 (Non-HVHZ, No Lap Sealant) 91TCIALEW IN IMPAt t t 5t5TAfJ ClEfAWA15, %Okf 1`170 ri 5. & WIl 0145 Max Design Pressure: -128.5 psf Clip Anchor Spacing: 4' Fmm Ends, i? Max. O.C. Min Panel Fasteners: #10x1' Pancake Head Fasteners, @ Per Di Fire Bamer. Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ, 1' round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type 11, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami -Dade NOA Nole: Outside of the HVHZ, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: '/z (15132' min) 4-ply CDX Plywood or'/4' solid wood planks (S.G. = 0.42 min), nailed to 2x rafters spaced 24' max. on center with 8d ring -shank nails spaced 6' on center. Note: The'/,' wood pEanking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Arch ltect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. Rational analysis, provided by a Florida licensed Arch i tecIJEngi neer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 5. Where required by code, all panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, 'Dynamic Metals FL# 30751.4, DM Class 1700'. 9' CVC IZW N IMPACf M95TMT Gk~Wi . 5TOFfFV01105. & WWON5 Panel Forming These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 31d party QA provider, to the dimensions shown on Drawing 1700SLHZ: SSQ-6800617 SSQ-5150216 SSG-6810617 SSQ-6690517 SSQ-4560615 SS02-2310920 5VC-049071 B 5VC-0360516 SS02-2320920 Re -Roofing. The DM Class 1700 Series 26 Ga. Galvalume SnapLock 1 !/2 Standing Seam Roof Panel may be installed over a single layer of existing asphalt shingles, provided the existing roof meets the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the Fbrida Building Code If you have any questions or need more information concerning this approval, please contact me. `� �O Thank you .�`� O ......... r,EMSE No 62354 *Scolt¢ FL PE# 62354 : - STATE OF AUG 2 3 2020 =0 � 1 1 /2- (NOA1lNAL) D z m r 0 T r m z z 0 z ro r a � r OxOz s N N O C M Z m U < Z r LA C r 1 A > 0 0 D N cn n z v z G) cn m D O O n z n z m r 0 r n cn En 0 0 N G� D CD m m r- cn z D a r- O 0 X 'n "I 40 co �G) r D _ < Q a� Lnm� c<'Z 9 ^^> �v x m gym= Am r1 0 ,.r,tuni , r DYNAMIC METALS „mof" 6 - - �. L = •: - y �340?IKE ROAD www dynamxmetal nef$�7F F ;•4 , WEST PALM BEACH, FL 33782 FAX. j5611619-7191 GUT rur r n ssm ;ate•, jj' 1O r+ �t� yn� o o PH: (5611629-7288 EMAJL m/aPdynamicmetufnet lwi) m''� % F , -� . i C . '...... .. S mmm F�w KV-21 DATE