Loading...
HomeMy WebLinkAbout280425791 Pursuit Boats FA-02REMOTE POWER SUPPLY HONEYWELL HPFF12 TO DEDICATED 120V 20AMPS CIRCUIT BY OTHERS GROUND #12 AWG THHN CU. CONDUCTOR RISER DIAGRAM 2 #14 THHN 16/2 FPLR WIRE SCHEDULE 185cd 1-1-1 1-1-2 1-1-3 1-1-4 1-1-5 1-1-6 1-1-7 1-1-8 1-1-9 1-2-1 1-2-2 1-2-3 1-2-4 1-2-5 1-2-6 1-2-8 1-2-9 1-3-1 1-3-2 1-3-3 1-3-4 1-3-5 1-3-6 1-3-7 1-3-8 1-3-9 1-3-10 1-4-1 1-4-2 1-4-3 1-4-4 1-4-5 1-4-6 1-4-7 1-4-8 1-4-9 1-4-10 185cd 135cd 135cd 135cd 135cd 115cd 185cd 185cd 185cd 185cd75cd 135cd 135cd 135cd 135cd185cd185cd185cd185cd185cd185cd 135cd 135cd 135cd 135cd185cd185cd 185cd 185cd 185cd 185cd FIRE ALARM CONTROL PANEL NOTIFIER NFW-100X TO DEDICATED 120V 20AMPS CIRCUIT BY OTHERS GROUND #12 AWG THHN CU. CONDUCTOR 0-1-1 75cd75cd75cd75cd75cd75cd110cd110cd185cd185cd185cd 0-1-20-1-30-1-40-1-50-1-60-1-70-1-80-1-90-1-100-1-11 0-2-10-2-20-2-30-2-40-2-50-2-60-2-70-2-80-2-90-2-100-2-110-2-12 75cd75cd75cd75cd75cd75cd75cd 110cd110cd185cd185cd185cd REMOTE ANNUNCIATOR NOTIFIER N-ANN-80 D01 M01M04M08M11 D05 M13 M14 M12 M15 M20 M25 M30M35M36M37M38 M40 M39 D02D03D04 M02M05M09M10 M29 M03M06M07 M16 M17 M18 M19 M21 M22 M23 M24 M26 M27 M28M31M32M33M34 M41 M42 M43 M44 M45 M46 M47 M48 M49 CELLULAR RADIO TELGUARD - TG-7 CEILING FAN SHUTDOWN 2 #12 THHN 1-1-10 1-1-11 1-1-12 115cd 115cd 115cd 115cd 115cd 1-1-13 75cd 115cd 115cd 115cd 1-2-7 185cd WP M53 M54 M55 SHUTDOWN M56 M57 M58 SHUTDOWN RED GLUE BOOTH VARNISH BOOTH M50M51M52 SHUTDOWN YELLOW GLUE BOOTH 3150 SW 42nd AvePalm City, Florida 34990Ph: 772.232.2001Fax: 772.232.200424 HOUR EMERGENCY SERVICEFire Sprinklers - Fire Alarms Inspections - ServiceFlorida State License #FPC14-000102Florida State Alarm License #EC13004155THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF ADT COMMERCIAL. IT IS NOT TO BE USED OR DUPLICATED BY ANYONE WITHOUT THE WRITTEN CONSENT OF ADT COMMERCIAL. JURISDICTION: PROJECT NO: DATE: DESIGNED BY: SHEET: FA-02 TITLE:3891 ST LUCIE BLVDFORT PIERCE, FL 34946FIRE ALARM PLANPURSUIT BOATS--- AD 12.17.2020 280425791 SCALE:1/8"= 1'-0" IF ANY DOCUMENT PREPARED BY ADT COMMERCIAL IS ALTERED IN ANY MANNER BY OWNER, ITS AGENTS OR BY ANY THIRD PARTY IF CONSTRUCTION IS NOT IN ACCORDANCE WITH UNALTERED DOCUMENTS PREPARED BY ADT COMMERCIAL THEN IT IS UNDERSTOOD THAT ADT COMMERCIAL HAS NO LIABILITY IN WHOLE OR IN PART, RELATED TO THE PROJECT AND THAT THE OWNER AND ITS AGENTS INDEMNIFY AND HOLDS HARMLESS ADT COMMERCIAL FOR ANY AND ALL ACTS RELATED TO THE PROJECT. THIS CONCEPT DRAWING IS FOR INFORMATION ONLY TO POTENTIAL SYSTEM ARRANGEMENT. CONTRACTOR SHALL FIELD VERIFY ALL INFORMATION CONTAINED ON THESE DRAWINGS AND IS RESPONSIBLE FOR DESIGN AND INSTALLATION OF THE SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS. TO THE BEST OF ADT COMMERCIAL'S KNOWLEDGE THE DRAWINGS AND SPECIFICATIONS SUBMITTED HEREWITH, COMPLY WITH EXISTING INTERPRETATIONS AND PREVISIONS OF THE APPLICABLE N.F.P.A. CODES IN EFFECT AT DATE SHOWN. RFA-02 FIRE ALARM PLAN